• Title/Summary/Keyword: response sensitivity

Search Result 1,801, Processing Time 0.032 seconds

A New Malting Barley Variety, "Daho" with High Yielding and BaYMV Resistance (맥주보리 호위축병저항성 및 다수성 "다호")

  • Hyun, Jong-Nae;Kim, Mi-Jung;Kim, Yang-Kil;Lee, Mi-Ja;Choi, Jae-Sung;Kim, Hyun-Tae;Han, Sang-Ik;Ko, Jong-Min;Lim, Sea-Gyu;Park, Jong-Chul;Kim, Jung-Gon;Suh, Sae-Jung;Kim, Dae-Ho;Kang, Sung-Ju;Kim, Sung-Taeg
    • Korean Journal of Breeding Science
    • /
    • v.41 no.3
    • /
    • pp.333-337
    • /
    • 2009
  • A new malting barley variety, "Daho", was developed from the cross between "Milyang85 and Suwon335" at the Department of Rice and Winter Cereal Crop (DRWCC) NICS, in 2007. An elite line, YMB2064-B-8-2-4-1-1, was selected in 2004 and designated as "Milyang134". It showed good agronomic performance in the regional adaptation yield trials (RYT) from 2005 to 2007 and was released with the name of "Daho", having high yielding and BaYMV resistance. The average heading and maturing dates of "Daho" were April 19 and May 27, which were 2 days later and 1 day earlier than those of "Jinyang", leading variety, at the regional adaptation yield trials (RYT), respectively. "Daho" had longer culm length (84 cm), more spikes per $m^2$ (915) and higher 1,000 grain weight (39.2 g) than those of "Jinyang" in paddy field condition. "Daho" was showed resistance to BaYMV at the regions of Naju, Jinju, and Milyang but moderately resistance at Iksan. However, the response of "Daho" to other environmental stresses was similar to "Jinyang". The yields of "Daho" at upland and paddy fields were about 5.20 MT/ha, 4.81 MT/ha, respectively, which is about 38%, 25% higher than those of "Jinyang" in the regional adaptation yield trials (RYT), respectively. It has higher grain assortment, germination capacity, water sensitivity and Kolback index but lower malt extract, diastatic power and filtration speed than those of "Jinyang".

A New High-Yielding Malting Barley Cultivar "Oreum" with High Yielding and BaYMV Resistance (호위축병저항성 다수성 맥주보리 "오름")

  • Hyun, Jong-Nae;Kim, Mi-Jung;Kim, Yang-Kil;Lee, Mi-Ja;Choi, Jae-Sung;Kim, Hyun-Tae;Han, Sang-Ik;Ko, Jong-Min;Lim, Sea-Gyu;Park, Jong-Chul;Kim, Jung-Gon;Suh, Sae-Jung;Kim, Dae-Ho;Kang, Sung-Ju;Kim, Sung-Taeg
    • Korean Journal of Breeding Science
    • /
    • v.41 no.3
    • /
    • pp.328-332
    • /
    • 2009
  • A new malting barley variety, "Oreum", was developed from the a cross between 'Kinuyutaka' and 'Samdobori' at the Honam Agricultural Research Institute (HARI) in 2006. An elite line, YMB2077-2B-24-1-2, was selected in 2003 and designated as 'Milyang132'. It showed good agronomic performance in the regional adaptation yield trials (RYT) from 2004 to 2006, and was released with the name of "Oreum" having high yielding and BaYMV resistance. The average heading and maturing dates of "Oreum" were April 18 and May 24, which were 2 days later than 'Jinyang', a leading variety, at RYT. "Oreum" had longer culm length (75 cm), more spikes per $m^2$ (990), and lighter 1,000 grain weight (35.2 g) than those of 'Jinyang' in paddy field conditions. It was showed resistance to BaYMV at the regions of Naju, Jinju and Milyang but moderate resistance at Iksan. However, the response to other environmental stresses of was similar to 'Jinyang' The yield potential of "Oreum" was about 5.43 MT/ha, 4.93 MT/ha in upland and paddy fields which was about 80%, 35% higher than Jinyang in the regional adaptation yield trials (RYT), respectively. It has good malting quality including high grain assortment, germination capacity ratio, water sensitivity and high the malt production and the extract and short filtration speed than those of 'Jinyang'.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

Dynamic Equilibrium Position Prediction Model for the Confluence Area of Nakdong River (낙동강 합류부 삼각주의 동적 평형 위치 예측 모델: 감천-낙동강 합류점 중심 분석 연구)

  • Minsik Kim;Haein Shin;Wook-Hyun Nahm;Wonsuck Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.4
    • /
    • pp.435-445
    • /
    • 2023
  • A delta is a depositional landform that is formed when sediment transported by a river is deposited in a relatively low-energy environment, such as a lake, sea, or a main channel. Among these, a delta formed at the confluence of rivers has a great importance in river management and research because it has a significant impact on the hydraulic and sedimentological characteristics of the river. Recently, the equilibrium state of the confluence area has been disrupted by large-scale dredging and construction of levees in the Nakdong River. However, due to the natural recovery of the river, the confluence area is returning to its pre-dredging natural state through ongoing sedimentation. The time-series data show that the confluence delta has been steadily growing since the dredging, but once it reaches a certain size, it repeats growth and retreat, and the overall size does not change significantly. In this study, we developed a model to explain the sedimentation-erosion processes in the confluence area based on the assumption that the confluence delta reaches a dynamic equilibrium. The model is based on two fundamental principles: sedimentation due to supply from the tributary and erosion due to the main channel. The erosion coefficient that represents the Nakdong River confluence areas, was obtained using data from the tributaries of the Nakdong River. Sensitivity analyses were conducted using the developed model to understand how the confluence delta responds to changes in the sediment and water discharges of the tributary and the main channel, respectively. We then used annual average discharge of the Nakdong River's tributaries to predict the dynamic equilibrium positions of the confluence deltas. Finally, we conducted a simulation experiment on the development of the Gamcheon-Nakdong River delta using recorded daily discharge. The results showed that even though it is a simple model, it accurately predicted the dynamic equilibrium positions of the confluence deltas in the Nakdong River, including the areas where the delta had not formed, and those where the delta had already formed and predicted the trend of the response of the Gamcheon-Nakdong River delta. However, the actual retreat in the Gamcheon-Nakdong River delta was not captured fully due to errors and limitations in the simplification process. The insights through this study provide basic information on the sediment supply of the Nakdong River through the confluence areas, which can be implemented as a basic model for river maintenance and management.

The Diversification of Environmental Aesthetics and the Rise of Everyday Aesthetics - Theoretical Agendas and Issues of Yuriko Saito's Everyday Aesthetics - (환경미학의 다변화와 일상미학의 부상 - 유리코 사이토의 일상미학 이론의 의제와 쟁점을 중심으로 -)

  • Pae, Jeong-Hann
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.42-53
    • /
    • 2023
  • This paper explores the recent development of environmental aesthetics and critically examines the main agendas, claims, issues, and implications of everyday aesthetics, which is emerging as an important branch of environmental aesthetics. Environmental aesthetics began in the context of cultural change and environmentalism in the 1960s and expanded in the second half of the 20th century with a solid theoretical foundation. At the beginning of the 21st century, it entered a process of diversification of objects and subjects. Having reached academic maturity, environmental aesthetics has expanded into theoretical territory considering the urban environment and the human environment, providing practical coordinates as a discourse for planning and designing urban environments and landscapes. The most notable achievement of environmental aesthetics since the mid-2000s is the establishment of 'everyday aesthetics'. Yuriko Saito, who is leading the research on everyday aesthetics, expanded the objects and scope of aesthetic theory to everyday objects, events, activities, and environments. She excavates the microscopic and sensory aspects of everyday life, which have been overlooked by conventional art-centered aesthetics, through the lens of aesthetics. She reinterprets various layers of phenomena in contemporary urban landscapes and analyzes how the 'power of the aesthetic' hidden in everyday life profoundly affects the quality of life and the state of the world. Saito examines the appreciation of the distinctive characteristics and ambiance inherent in everyday objects and environments and proposes a 'moral-aesthetic judgment' to alert citizens to the environmental, social, and political consequences of everyday aesthetic appreciation and response. This paper identifies the issues and implications of everyday aesthetics as first, the expansion of aesthetics and the ambiguous everyday, second, the moral-aesthetic judgment and the aesthetics of care, and third, urban regeneration landscapes and aesthetic literacy. In particular, the moral virtues of everyday aesthetics that Saito proposes, such as care, thoughtfulness, sensitivity, and respect, provide a critical reference for the practice of contemporary urban regeneration landscapes. The 'aesthetic literacy' is a key concept demonstrating why an environmental aesthetics perspective is necessary to interpret everyday urban environments and landscapes.

A Study on the Perception of Policy Targets to Improve the Effectiveness of Child Safety Measure - Focusing on Children, Guardians, and Workers in Children's Facilities - (어린이 안전대책 실효성 향상을 위한 정책대상자 인식조사 연구 - 어린이, 보호자, 어린이이용시설 종사자 중심으로 -)

  • ChangYoung Song;WonHoi Koo
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.869-881
    • /
    • 2023
  • Purpose: This study aims to come up with improvement measures to improve the effectiveness of child safety measures. Method: The current status of child safety accidents was investigated and implications were deduced by analyzing major child safety measures by government department in the past. In addition, a perception survey was conducted on 1,000 people including children, guardians, and children's facility workers who are subject to child safety policies. Result: Regarding the safety of children's living space(environment), 35.3% of guardians answered that more than 1/3 of them were not safe. Both guardians(95.3%) and children's facility workers(89%) answered that there was the highest risk of 'traffic accidents', and the second risk factor was parents(carelessness of workers at children's facilities) and children's facility workers(careless of guardians at home). Looking at the risks by place, "road and sidewalk" was the most dangerous place and for child safety, guardians(64.3%) and workers (78.3%) both said that the role of "parent" is the most important. For improvements to prevent child safety accidents, the response rate of "strengthening safety management of road traffic facilities" is the most necessary with 75.8% for guardians and 65% for child use facilities. Conclusion: The reinforcement measures to strengthen the effectiveness of child safety measures are as follows. First, in order to ensure the continuity of child safety measures, it should be operated effectively so that those subject to the establishment of the Comprehensive Plan for Child Safety, which took effect in August 2022, can feel it. Second, in order to improve the sensitivity of children's policy targets, promotion measures that take into account the characteristics of each child safety field should be continuously strengthened. Third, it is necessary to expand safety infrastructure for each field to secure child safety. Fourth, it is necessary to strengthen safety education that can ensure safety for children themselves and to come up with detailed measures to make safety education for parents(guardians) mandatory.

The detection of collapsible airways contributing to airflow limitation (기류 제한에 영향을 미치는 허탈성 기도의 분석)

  • Kim, Yun Seong;Park, Byung Gyu;Lee, Kyong In;Son, Seok Man;Lee, Hyo Jin;Lee, Min Ki;Son, Choon Hee;Park, Soon Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.558-570
    • /
    • 1996
  • Background : The detection of Collapsible airways has important therapeutic implications in chronic airway disease and bronchial asthma. The distinction of a purely collapsible airways disease from that of asthma is important because the treatment of the dormer may include the use of pursed lip breathing or nasal positive pressure ventilation whereas in the latter, pharmacologic approaches are used. One form of irreversible airflow limitation is collapsible airways, which has been shown to be a Component of asthma or to emphysema, it can be assessed by the volume difference between what exits the lung as determined by a spirometer and the volume compressed as measured by the plethysmography. Method : To investigate whether volume difference between slow and forced vital Capacity(SVC-FVC) by spirometry may be used as a surrogate index of airway collapse, we examined pulmonary function parameters before and after bronchodilator agent inhalation by spirometry and body plethysmography in 20 cases of patients with evidence of airflow limitation(chronic obstructive pulmonary disease 12 cases, stable bronchial asthma 7 cases, combined chronic obstructive pulmonary disease with asthma 1 case) and 20 cases of normal subjects without evidence of airflow limitation referred to the Pusan National University Hospital pulmonary function laboratory from January 1995 to July 1995 prospectively. Results : 1) Average and standard deviation of age, height, weight of patients with airflow limitation was $58.3{\pm}7.24$(yr), $166{\pm}8.0$(cm), $59.0{\pm}9.9$(kg) and those of normal subjects was $56.3{\pm}12.47$(yr), $165.9{\pm}6.9$(cm), $64.4{\pm}10.4$(kg), respectively. The differences of physical characteristics of both group were not significant statistically and male to female ratio was 14:6 in both groups. 2) The difference between slow vital capacity and forced vital capacity was $395{\pm}317ml$ in patients group and $154{\pm}176ml$ in normal group and there was statistically significance between two groups(p<0.05). Sensitivity and specificity were most higher when the cut-off value was 208ml. 3) After bronchodilator inhalation, reversible airway obstructions were shown in 16 cases of patients group, 7 cases of control group(p<0.05) by spirometry or body plethysmography d the differences of slow vital capacity and forced vital capacity in bronchodilator response group and nonresponse group were $300.4{\pm}306ml$, $144.7{\pm}180ml$ and this difference was statistically significant. 4) The difference between slow vital capacity and forced vital capacity before bronchodilator inhalation was correlated with airway resistance before bronchodilator(r=0.307 p=0.05), and the difference between slow vital capacity and forced vital capacity after bronchodilator was correlated with difference between slow vital capacity and forced vital capacity(r=0.559 p=0.0002), thoracic gas volume(r=0.488 p=0.002) before bronchodilator and airway resistance(r=0.583 p=0.0001), thoracic gas volume(r=0.375 p=0.0170) after bronchodilator, respectively. 5) The difference between slow vital capacity and forced vital capacity in smokers and nonsmokers was $257.5{\pm}303ml$, $277.5{\pm}276ml$, respectively and this difference did not reach statistical significance(p>0.05). Conclusion : The difference between slow vital capacity and forced vital capacity by spirometry may be useful for the detection of collapsible airway and may help decision making of therapeutic plans.

  • PDF

Effects of FK224, a $NK_1$ and $NK_2$ Receptor Antagonist, on Plasma Extravasation of Neurogenic Inflammation in Rat Airways (미주 신경의 전기적 자극으로 유발된 백서의 기도내 혈장 유출에 대한 FK224의 효과)

  • Shim, Jae-Jeong;Lee, Sang-Yeub;Lee, Sang-Hwa;Park, Sang-Myun;Seo, Jeong-Kyung;Cho, Jae-Yun;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.5
    • /
    • pp.744-751
    • /
    • 1995
  • Background: Asthma is an inflammatory disease because there are many inflammatory changes in the asthmatic airways. Axon reflex mechanisms may be involved in the pathogenesis of asthma. Sensory neuropeptides are involved in this inflammation, which is defined as neurogenic inflammation. Substance p, neurokinin A, and neurokinin B may be main neuropeptides of neurogenic inflammation in airways. These tachykinins act on neurokinin receptors. Three types of neurokinin receptors, such as $NK_1$, $NK_2$, and $NK_3$, are currently recognized, at which substance p, neurokinin A, and neurokinin B may be the most relevant natural agonist of neurogenic inflammation in airways. The receptor subtypes present in several tissues have been characterized on the basis of differential sensitivity to substance p, neurokinin A, and neurokinin B. Plasma extravasation and vasodilation are induced by substance p more potently than by neurokinin A, indicating NK1 receptors on endothelial cells mediate the response. But airway contraction is induced by neurokinin A more potently than by substance P, indicating the $NK_2$ receptors in airway smooth muscles. These receptors are used to evaluate the pathogenesis of brochial asthma. FK224 was identified from the fermentation products of Streptomyces violaceoniger. FK224 is a dual antagonist of both $NK_1$ and $NK_2$ receptors. Purpose: For a study of pathogenesis of bronchial asthma, the effect of FK224 on plasma extravasation induced by vagal NANC electrical stimulation was evaluated in rat airway. Method: Male Sprague-Dawley rats weighing 180~450gm were anesthetized by i.p. injection of urethane. Plasma extravasation was induced by electrical stimulation of cervical vagus NANC nerves with 5Hz, 1mA, and 5V for 2 minutes(NANC2 group) and for sham operation without nerve stimulation(control group). To evaluate the effect of FK224 on plasma extravasation in neurogenic inflammation, FK224(1mg/kg, Fujisawa Pharmaceutical Co., dissolved in dimethylsulphoxide; DMSO, Sigma Co.) was injected 1 min before nerve stimulation(FK224 group). To assess plasma exudation, Evans blue dye(20mg/kg, dissolved in saline) was used as a plasma marker and was injected before nerve stimulation. After removal of intravascular dye, the evans blue dye in the tissue was extracted in formamide($37^{\circ}C$, 24h) and quantified spectrophotometrically by measuring dye absorbance at 629nm wavelength. Tissue dye content was expressed as ng of dye per mg of wet weight tissue. The amount of plasma extravasation was measured on the part of airways in each groups. Results: 1) Vagus nerve(NANC) stimulation significantly increased plasma leakage in trachea, main bronchus, and peripheral bronchus compared with control group, $14.1{\pm}1.6$ to $49.7{\pm}2.5$, $17.5{\pm}2.0$ to $38.7{\pm}2.8$, and $12.7{\pm}2.2$ to $19.1{\pm}1.6ng$ of dye per mg of tissue(mean ${\pm}$ SE), respectively(p<0.05). But there was not significantly changed in lung parenchyma(p>0.05) 2) FK224 had significant inhibitory effect upon vagal nerve stimulation-induced airway plasma leakage in any airway tissues of rat,such as trachea, main bronchus, and peripheral bronchus compared with vagus nerve stimulation group, 49%, 58%, and 70%, respectively(p<0.05). Inhibitory effect of FK224 on airway plasma leakage in neurogenic inflammation was revealed the more significant in peripheral bronchus, but no significant in lung parenchyma. Conclusion: These results suggest that FK224 is a selective NK receptor antagonist which effectively inhibits airway plasma leakage induced by the endogenous neurotransmitters relased by neurogenic inflammation in rat airway. Tachykinin receptor antagonists may be useful in the treatment of brochial asthma.

  • PDF

Home Economics teachers' concern on creativity and personality education in Home Economics classes: Based on the concerns based adoption model(CBAM) (가정과 교사의 창의.인성 교육에 대한 관심과 실행에 대한 인식 - CBAM 모형에 기초하여-)

  • Lee, In-Sook;Park, Mi-Jeong;Chae, Jung-Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.24 no.2
    • /
    • pp.117-134
    • /
    • 2012
  • The purpose of this study was to identify the stage of concern, the level of use, and the innovation configuration of Home Economics teachers regarding creativity and personality education in Home Economics(HE) classes. The survey questionnaires were sent through mails and e-mails to middle-school HE teachers in the whole country selected by systematic sampling and convenience sampling. Questionnaires of the stages of concern and the levels of use developed by Hall(1987) were used in this study. 187 data were used for the final analysis by using SPSS/window(12.0) program. The results of the study were as following: First, for the stage of concerns of HE teachers on creativity and personality education, the information stage of concerns(85.51) was the one with the highest response rate and the next high in the following order: the management stage of concerns(81.88), the awareness stage of concerns(82.15), the refocusing stage of concerns(68.80), the collaboration stage of concerns(61.97), and the consequence stage of concerns(59.76). Second, the levels of use of HE teachers on creativity and personality education was highest with the mechanical levels(level 3; 21.4%) and the next high in the following order: the orientation levels of use(level 1; 20.9%), the refinement levels(level 5; 17.1%), the non-use levels(level 0; 15.0%), the preparation levels(level 2; 10.2%), the integration levels(level 6; 5.9%), the renewal levels(level 7; 4.8%), the routine levels(level 4; 4.8%). Third, for the innovation configuration of HE teachers on creativity and personality education, more than half of the HE teachers(56.1%) mainly focused on personality education in their HE classes; 31.0% of the HE teachers performed both creativity and personality education; a small number of teachers(6.4%) focused on creativity education; the same number of teachers(6.4%) responded that they do not focus on neither of the two. Examining the level and type of performance HE teachers applied, the average score on the performance of creativity and personality education was 3.76 out of 5.00 and the mean of creativity component was 3.59 and of personality component was 3.94, higher than standard. For the creativity education, openness/sensitivity(3.97) education was performed most and the next most in the following order: problem-solving skill(3.79), curiosity/interest(3.73), critical thinking(3.63), problem-finding skill(3.61), originality(3.57), analogy(3.47), fluency/adaptability(3.46), precision(3.46), imagination(3.37), and focus/sympathy(3.37). For the personality education, the following components were performed in order from most to least: power of execution(4.07), cooperation/consideration/just(4.06), self-management skill(4.04), civic consciousness(4.04), career development ability(4.03), environment adaptability(3.95), responsibility/ownership(3.94), decision making(3.89), trust/honesty/promise(3.88), autonomy(3.86), and global competency(3.55). Regarding what makes performing creativity and personality education difficult, most HE teachers(64.71%) chose the lack of instructional materials and 40.11% of participants chose the lack of seminar and workshop opportunity. 38.5% chose the difficulty of developing an evaluation criteria or an evaluation tool while 25.67% responded that they do not know any means of performing creativity and personality education. Regarding the better way to support for creativity and personality education, the HE teachers chose in order from most to least: 'expansion of hands-on activities for students related to education on creativity and personality'(4.34), 'development of HE classroom culture putting emphasis on creativity and personality'(4.29), 'a proper curriculum on creativity and personality education that goes along with students' developmental stages'(4.27), 'securing enough human resource and number of professors who will conduct creativity and personality education'(4.21), 'establishment of the concept and value of the education on creativity and personality'(4.09), and 'educational promotion on creativity and personality education supported by local communities and companies'(3.94).

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF