• Title/Summary/Keyword: response control

Search Result 9,144, Processing Time 0.041 seconds

The Response Improvement of PD Type FLC System by Self Tuning (자기동조에 의한 PD 형 퍼지제어시스템의 응답 개선)

  • Choi, Hansoo;Lee, Kyoung-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.12
    • /
    • pp.1101-1105
    • /
    • 2012
  • This study proposes a method for improvement of PD type fuzzy controller. The method includes self tuner using gradient algorithm that is one of the optimization algorithms. The proposed controller improves simple Takagi-Sugeno type FLC (Fuzzy Logic Control) system. The simple Takagi-Sugeno type FLC system changes nonlinear characteristic to linear parameters of consequent membership function. The simple FLC system could control the system by calibrating parameter of consequent membership function that changes the system response. While the determination on parameter of the simple FLC system works well only partially, the proposed method is needed to determine parameters that work for overall response. The simple FLC system doesn't predict the response characteristics. While the simple FLC system works just like proportional part of PID, our system includes derivative part to predict the next response. The proposed controller is constructed with P part and D part FLC system that characteristic parameter on system response is changed by self tuner for effective response. Since the proposed controller doesn't include integral part, it can't eliminate steady state error. So we include a gain to eliminate the steady state error.

Performance Evaluation of Wind Response Control of High-Rise Buildings by Damping and Stiffness of Outrigger Damper System (아웃리거 댐퍼시스템의 감쇠와 강성에 따른 고층 건물 풍응답 제어 성능 평가)

  • Park, Kwang-Seob;Kim, Yun-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.41-48
    • /
    • 2018
  • Recently, the concept of an outrigger damper system with a damper added to the existing outrigger system has been developed and applied for dynamic response control of high-rise buildings. However, the study on the structural characteristics and design method of Outrigger damper system is in the early stages. In this study, a 50 story high - rise building was designed and an outrigger damper system with viscoelastic damper was applied for wind response control. The time history analysis was performed by using the kaimal spectrum to create an artificial wind load for a total of 1,000 seconds at 0.1 second intervals. Analysis of the top horizontal maximum displacement response and acceleration response shows that outrigger damper systems are up to 28.33% and 49.26% more effective than conventional outrigger systems, respectively. Also, it is confirmed that the increase of damping ratio of dampers is effective for dynamic response control. However, since increasing the damping capacity increases the economic burden, it is necessary to select the appropriate stiffness and damping value of the outrigger damper system.

Improvement of control law for response charaoteristics of a variable structure control system (가변구조제어계의 응답특성향상을 위한 제어법칙의 개선)

  • 김중완;이만형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.508-512
    • /
    • 1989
  • A new control law of a VSCS is illustrated and put into an analytical form. Using the presented control law, a VSCS shows smooth response, low control input and high accuracy in comparison with those by typical control law.

  • PDF

Effect of Apartment Residents' Safety Awareness on Fire Response Performance: Focusing on the Moderating Effect of Control Offices' Control Competence (아파트 거주자의 안전의식이 화재대응성과에 미치는 영향 : 관리사무소의 관리역량 조절효과를 중심으로)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.43-53
    • /
    • 2020
  • The purpose of this study is to reduce the anxiety factors of fires by following evacuation tips in case of fire in an apartment household. This study analyzed the moderating effects of the control offices' competence in control on safety awareness and fire response. The study results were as follows. First, the residents and control staff's safety awareness had a positive effect on the fire response performance. This indicates that the higher the residents and control staff's safety awareness level, the higher the fire responsive performance. Second, the higher the control offices' control competence level, the better the apartment residents and control staff's safety awareness had a positive effect on the fire response performance. These results indicate that the higher the control office heads' leadership, the higher the apartment residents' housing satisfaction and that the more communicative the control office heads' attitude toward the residents, the better their attitude had a positive effect on the fire response performance. Lastly, the control offices' control competence was analyzed to have a moderating effects on the effect of the apartment residents and control staff's safety awareness level on the fire response performance. These results showed that the change in the model's R2 value showed an increasing trend in stages as the value increased more in the stage 2 than the stage 1 and even more in the stage 3 with the interaction terms of the moderating variables added. For this reason, the control offices' control competence which was a moderating variable was analyzed to have a moderating effect on the effect of residents and control staff's safety awareness level on the fire response performance.

A STUDY ON THE HUMAN PULPAL RESPONSE TO DENTIN BONDING DESENSITIZER (상아질 접착 지각과민 처치제에 대한 치수반응에 관한 연구)

  • You, Hee-Seung;Lee, Sung-Bok;Woo, Yi-Hyung;Park, Nam-Soo;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.483-495
    • /
    • 1998
  • The purpose of this study was to evaluate the human pulpal response to Dentin Bonding Desensitizer. Class V cavities were prepared on the buccal surfaces of the first premolars and Dentin Bonding Desensitizer(ALL-BOND Desensitizer, Bisco, Inc. U.S.A.) was applicated in ten experimental teeth, or ZOE(PROPAC, GC Co. TOKYO, JAPAN) cement in eight control teeth and cavities were filled with light curing glass ionomer(Fuji II LC, GC Co., TOKYO, JAPAN). At 3-day and 25-day postoperative interval. pulpal response was observed and evaluated histologically with light microscope. The results were as follows. ; 1. At 3-day postoperative interval, the control teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. 2. At 25-day postoperative interval, all control teeth were grade 1 inflammatory cell response and in three control teeth grade 1 connective tissue response were observed, and one teeth showed grade 2 connective tissue response. 3. At 3-day postoperative interval, the experimental teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. Below the cavity, a few inflammatory cell(PMNs) in odontoblastic layer, increased blood vessels and pulpal cells were seen and this pulpal response was similar to control teeth. 4. At 25-day postoperative interval, in four experimental teeth grade 1 inflammatory cell response and grade 1 connective tissue response were observed, and one experimental teeth showed mild inflammatory response. 5. At 3-day and 25-day postoperative interval, no reparative dentin deposition was seen. 6. Both experimental and control group, pulpal response showed difference between 3 and 25-day of postoperative interval. In control teeth, increased predentin and pulpal cells were seen and in experimental teeth, congestion of blood vessels and increased pulpal cells were seen. In conclusion, the pulpal irritation due to this Dentin Bonding Desensitizer was not severe, and it was considered that the agent was not harmful to the human pulp.

  • PDF

Improvement of the Response Characteristics Using the Fuzzy-PLL Controller (퍼지-PLL 제어기를 이용한 응답특성 개선)

  • Cho, Jeong-Hwan;Seo, Choon-Weon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.175-181
    • /
    • 2005
  • This paper proposes the fuzzy-PLL control system for fast response time and precision control of automation systems. The conventional PLL has not only a jitter noise caused from such a demerit of the wide dead zone, but also a long delay interval that makes a high speed operation unable. In order to solve the problems, the proposed system, which provides the improvement in terms of the control region in high speed and precision control, first used the fuzzy control method for fast response time and when the error reaches the preset value, used the PLL method designing new PFD for precision control. The new designed multi-PFD improves the dead zone, jitter noise and response characteristics, which is consists of P-PFD(Positive edge triggered PFD) and N-PFD(Negative edge triggered PFD) and can improve response characteristics to increase PFD gain.

Adaptive control with multiple model (using genetic algorithm)

  • Kwon, Seong-Chul;Park, Juhyun;Won, Sangchul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.331-334
    • /
    • 1996
  • It is a well-known problem that the adaptive control has a poor transient response. In order to improve this problem, the scheme that model-reference adaptive control (MRAC) uses the genetic algorithm (GA) in the search for parameters is proposed. Use genetic algorithm (GA) in the searching for controller's parameters set and conventional gradient method for fine tuning. And show the reduction of the oscillations in transient response comparing with the conventional MRAC.

  • PDF

Control Methodology of Inverse Response Process

  • Pratch, Tontirittiphol;Kiattisak, Kumwachara;Mongkol, Janchookiat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.48.6-48
    • /
    • 2002
  • in this paper, each methodology, e.g. normal single PID controller, direct synthesis method and inverse response compensator, will be compared to determine the best inverse response plant control method, by based on the appearance of the control performance and robustness from the simulation results. The flexibility of being able to maintain the system stability during the presence of plant model mismatch is one of the criteria to measure the robustness of overall control system. Once, plant has changed the condition, the model will need to be updated. Hence, the designed controller will not work properly. The caused of plant model mismatch is stayed by definition unknown but the most possib...

  • PDF

마이크로컴퓨터를 이용한 최적축 위치제어

  • Jo, Yong-Hyeon
    • ETRI Journal
    • /
    • v.6 no.2
    • /
    • pp.3-9
    • /
    • 1984
  • This paper proposes an optimal control scheme for shaft position control using microcomputer-based state-variable feedback. In this scheme a performance index was set up in order to ruduce the overshoot and improve the steady- state response speed, and the time-variant system parameters were identified in real time for optimal control. As a result of experiment, the over-shoot was not occured and the response speed was improved 2. 9 times about proportional control. This scheme improves the performance against the variation of load and sampling time, and adding the integral control in this scheme can reduce the steady-state error without any change in response time.

  • PDF

Influence of time delay and saturation capacity to the response of controlled structures under earthquake excitations

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.449-470
    • /
    • 2011
  • During the last thirty years many structural control concepts have been proposed for the reduction of the structural response caused by earthquake excitations. Their research and implementation in practice have shown that seismic control of structures has a lot of potential but also many limitations. In this paper the importance of two practical issues, time delay and saturation effect, on the performance of controlled structures, is discussed. Their influence, both separately and in interaction, on the response of structures controlled by a modified pole placement algorithm is investigated. Characteristic buildings controlled by this algorithm and subjected to dynamic loads, such as harmonic signals and actual seismic events, are analyzed for a range of levels of time delay and saturation capacity of the control devices. The response reduction surfaces for the combined influence of time delay and force saturation of the controlled buildings are obtained. Conclusions regarding the choice of the control system and the desired properties of the control devices are drawn.