• 제목/요약/키워드: respirable particulate matters ($PM_{10}$)

검색결과 9건 처리시간 0.028초

강제환기식 육계 사육시설의 계절별, 지점별, 주령별 PM, NH3 농도 조사 및 분석 (Investigation and Analysis of Particulate-matters and Ammonia Concentrations in Mechanically Ventilated Broiler House According to Seasonal Change, Measurement Locations and Age of Broilers)

  • 장동화;권경석;김종복;김중곤;양가영;최성민;장유나
    • 한국농공학회논문집
    • /
    • 제63권1호
    • /
    • pp.75-87
    • /
    • 2021
  • Air quality related to particulate matters and ammonia is being come to the fore as the national concern in Korea. CAPSS (Clean Air Policy Support System) provides emission coefficients of these kinds of particulate and gaseous matters in the fields of livestock; however reliability issues are consistently mentioned. Evaluation of emission rates of PM2.5 and NH3 of the country is very important, but only few studies are available as the background related to observation of the concentration of the particulate matter and ammonia, especially within livestock house in Korea. In this paper, long-term measurement of PM10, PM2.5, and ammonia within the mechanically ventilated broiler house were carried out to introduce backgrounds of generation and emission of the particulate matters and ammonia. Measurement results were analyzed according to seasonal changes, age of broilers(weeks) and measurement locations. Concentration of inhalable and respirable dust were also evaluated in terms of occupational respiratory health according to increase in broiler's activity. From the results of this study, identification of the generation mechanisms of the particulate and gaseous matters, and evaluation of the emission rate of these in the broiler house will be carried out.

산업 도시의 산업단지 부지와 주거 지역의 대기 중 호흡성 분진과 구성 미량 원소의 특성 (Characteristics of Atmospheric Respirable Particulate Matters and Trace Elements within Industrial Complex and Residential Sites in an Industrial City)

  • 김모근;신승호;조완근
    • Environmental Analysis Health and Toxicology
    • /
    • 제25권1호
    • /
    • pp.27-40
    • /
    • 2010
  • The current study was designed to scientifically evaluate the atmospheric particulate pollution in residences relative to their proximity to a Korean major iron/metal industrial complex (IMIC). This objective was achieved by measuring the concentrations and elemental composition of particulate matter with aerodynamic diameters equal to or less than 10 ${\mu}m$(PM10) in industrial ambient air from IMIC and residential ambient air with relative proximities to IMIC. The trace metals were analyzed using an inductively coupled plasma-atomic emission spectroscopy (ICP-AES). The industrial mean values exceeded the Korean year/70-${\mu}g/m^3$ standard for PM10, whereas the residential mean values did not. However, the maximum residential values did exceed or were close to the Korean PM10 year standard. For individual elements, the ambient concentrations ranged widely from values in the order of a few $ng/m^3$ to thousands of $ng/m^3$. The residential mean mass concentrations in the PM10 measured in the present study were higher than or similar to those reported in earlier studies. This study suggests that residents in neighborhoods near the IMIC are exposedto elevated particulate levels compared to residents living further away from such a source.

겨울철 서울도심의 대기중 부유분진의 특성 (The Characteristics of Suspended Particulate Matters in Downtown Seoul During Winter Period)

  • 김신도;김종호;이정주
    • 한국대기환경학회지
    • /
    • 제8권2호
    • /
    • pp.105-111
    • /
    • 1992
  • The characteristics of suspended particulate matters(dust) in Seoul had been studied. The effects of various environmental factors, such as passengers, motor vehicles, wind velocity, wind direction, temperature and humidity were examined during the study period. It was shown that the dust emission occurred through the heating was the major source, and the contribution of passengers and motor vehicles was relatively negligible during the night. It was also revealed that the number concentration between $0.5{\mu}m$ and $2.0{\mu}m$ was increased due to the attachment among the dusts and mists by the increased humidity during the night. Considering the fact that the particles larger than $2{\mu}m$ take the most part of weight concentration, it was suggested that the PM-10 method which considered respirable particle as a weighting factor should be adapted in the evaluation air quality.

  • PDF

서울 일부 지역 교통수단의 실내 공기질 평가 (Assesment of Indoor Air Quality within Public Transport Vehicles operating in specified locations throughout Seoul)

  • 손종렬;최달웅;최정숙;우완기
    • 환경위생공학
    • /
    • 제21권1호
    • /
    • pp.12-20
    • /
    • 2006
  • This paper was conducted concerning the degree of indoor air quality in public transport vehicles such as taxicabs, buses and subway trains, as sampled through the active participation of drivers and passengers in Seoul between 13th August 2005 and 2nd November 2005. The results were summarized as follows: 1. Among the measured substances especially respirable particulate matters ($PM_{10}$), total bacteria counts (TBC) and carbon dioxide ($CO_2$) exceeded the standard level of $150{\mu}g/m^3,\;800CFU/m^3$ and 1000ppm. 2. The concentration of carbon dioxide ($CO_2$) in taxi recorded 2491ppm, which is more than the standard amount of 1000ppm. This level was comparatively higher than all other public transportation methods. Total bacteria counts (TBC) in bus and subway recorded $1082CFU/m^3\;and\;1856CFU/m^3$, respectively. 3. The drivers who regularly work long hours showed the higher concern about contamination of the air inside the public transport vehicles and they considered it to be worse than the air outside. In contrast, the general public showed less concern about the air quality inside the public transport vehicles. However, they too acknowledged that the quality of the air inside the public transport vehicles was poor. In regards to the degree of indoor air quality in the public transport vehicles, a counterplan must be implemented urgently to effectively combat the excessive levels of $PM_{10}$, microorganism and $CO_2$. We need to gather more conclusive evidence pertaining to other possible contaminants and influencing factors.

강제환기식 산란계 사육시설의 PM, NH3 발생·배출 특성 조사 (Investigation on Generation and Emission of Particulate Matters and Ammonia from Mechanically-ventilated Layer House)

  • 장동화;양가영;권경석;김종복;하태환;장유나
    • 한국농공학회논문집
    • /
    • 제64권1호
    • /
    • pp.99-110
    • /
    • 2022
  • In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house were evaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit considering seasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10, PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgent to develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summer season were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing no significant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.

타코나이트 광산 공정에서의 실시간 질량측정기기와 실시간 수농도의 환산에 의한 질량농도와의 연관성 (Relationships between a Calculated Mass Concentration and a Measured Concentration of PM2.5 and Respirable Particle Matter Sampling Direct-Reading Instruments in Taconite Mines)

  • 정은교;장재길;송세욱;김정호
    • 한국산업보건학회지
    • /
    • 제24권1호
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives: The purposes of this study are to investigate workers' exposures to respirable particles generated in taconite mines and to compare two metric methods for mass concentrations using direct-reading instruments. Methods: Air monitorings were conducted at six mines where subjects have been exposed primarily to particulate matters in crushing, concentrating, and pelletizing processes. Air samples were collected during 4 hours of the entire work shift for similarly exposure groups(SEGs) of nine jobs(N=37). Following instruments were employed to evaluate the workplace: a nanoparticle aerosol monitor(particle size range; 10-1000 nm, unit: ${\mu}m^2/cc$, Model 9000, TSI Inc.); DustTrak air monitors($PM_{10}$, $PM_{2.5}$, unit: $mg/m^3$, Model 8520, TSI Inc.); a condensation particle counter(size range; 20-1000 nm, unit: #/cc, P-Trak 8525, TSI Inc.); and an optical particle counter(particle number by size range $0.3-25{\mu}m$, unit: #/cc, Aerotrak 9306, TSI Inc.). Results: The highest airborne concentration among SEGs was for furnace operator followed by pelletizing maintenance workers in number of particle and surface area, but not in mass concentrations. The geometric means of $PM_{2.5}$ by the DustTrak and the Ptrak/Aerotrak were $0.04{\mu}m$(GSD 2.52) and $0.07{\mu}m$(GSD 2.60), respectively. Also, the geometric means of RPM by the DustTrak and the Ptrak/Aerotrak were $0.16{\mu}m$(GSD 2.24) and $0.32{\mu}m$(GSD 3.24), respectively. The Pearson correlation coefficient for DustTrak $PM_{2.5}$ and Ptrak/Aerotrak $PM_{2.5}$ was 0.56, and that of DustTrak RPM and Ptrak/Aerotrak RPM was 0.65, indicating a moderate positive association between the two sampling methods. Surface area and number concentration were highly correlated($R^2$ = 0.80), while $PM_{2.5}$ and RPM were also statistically correlated each other($R^2$ = 0.79). Conclusions: The results suggest that it is possible to measure airborne particulates by mass concentrations or particle number concentrations using real-time instruments instead of using the DustTrak Aerosol monitor that monitor mass concentrations only.

미세먼지 저감을 위한 식재기법 및 도시 녹지계획 방향 - 중국 베이징시 사례를 중심으로 - (Planting Design Strategies and Green Space Planning to Mitigate Respirable Particulate Matters - Case Studies in Beijing, China -)

  • 허희염;김진오
    • 한국조경학회지
    • /
    • 제45권6호
    • /
    • pp.40-49
    • /
    • 2017
  • 본 연구는 미세먼지 문제가 심각한 중국 베이징시를 대상으로 최근 수행된 주요 녹화계획 사례를 선별하여 미세먼지 저감 차원에서 분석 비판하고, 이에 대한 개선방안을 제시하는데 목적이 있다. 주요 연구방법은 문헌고찰과 현장조사로 최근 학계에서 제시된 다양한 미세먼지 저감형 녹화계획에 대한 논문들을 종합적으로 검토하였으며, 이를 바탕으로 도로와 주거, 공장 등 3가지 유형별 미세먼지 저감형 녹화계획 원칙들을 도출하였다. 이러한 원칙들은 최근 베이징시에 조성된 3개의 녹화사례들을 미세먼지 저감의 효율성 차원에서 분석하는데 활용되었다. 본 연구의 사례연구 대상지는 베이징시 푸싱루와 푸륀 아파트 단지, 그리고 베이징 베치 후쿠다 다용도 자동차 공장으로, 이들의 녹화계획에 대한 분석은 현장 답사와 베이징시 원림국 공무원과의 인터뷰를 통해 이루어졌다. 연구결과, 미세먼지 노출량이 현저히 많은 푸싱루 도로와 푸륀 아파트단지, 그리고 베이징 베치 후쿠다 다용도 자동차 공장 사례들의 경우, 녹화계획 시 식생의 공간적 배치와 수종 선정이 미세먼지의 확산을 저감하는 데는 미흡한 것으로 조사되었다. 따라서, 베이징시의 경우 향후 미세먼지 저감형 녹화계획 기본 원칙들을 바탕으로 바람길과 현장 여건에 맞도록 식물을 배치하고 미세먼지 저감 효과가 있는 수종을 선택하여 녹지를 보완하고 조성하는데 집중할 필요가 있다. 본 연구는 미세먼지 저감을 위한 다양한 식재기법들과 수종 선정에 대한 광범위한 문헌 고찰을 바탕으로, 도로와 주거단지, 공장지역의 녹화계획에 대한 유용한 가이드라인을 도출하고, 이들의 적용 가능성과 문제점을 고찰한다는데 큰 의의가 있다. 향후 미세먼지 노출 우려가 높은 다른 유형의 토지이용에 대한 경험적 고찰과 이를 바탕으로 한 다양한 식생배치와 수종 선정에 대한 지속적인 연구가 이루어져야 할 것이다.

PM-10 내 중금속의 장기간 평균농도 및 위해도 평가 (An Assessment of the Long-Term Concentration of Heavy Metals and Associated Risk in Ambient PM-10)

  • 이혜문;김동술;이진홍
    • 한국대기환경학회지
    • /
    • 제12권5호
    • /
    • pp.555-566
    • /
    • 1996
  • In order to assess the long-term airborne concentrations of 6 metals such as Cr, Cd, Pb, Zn, K, and Na and the associated health resk, a great number of PM-10 samples were collected and analyzed in Kyung Hee University-Suwon Campus for three years from 1991 to 1993. The 3-year average concentration of Pb in respirable particulate matters was 142.6 ng/m$^{3}$ while that of Zn was 1,210.5ng/m$^{3}$. The corresponding hazard index from Pb Zn for the ingalation route was estimated to be 9.5.times.10$^{-2}$ and 3.5.times.10$^{-2}$ , respectively. Therefore, it can be said that there was no adverse chronic health effects by airborne Pb and Zn. However, the 2-year average concentration of Cr(6) was estimated to be 1.3ng/m$^{3}$ shile the 3-year average concentration of Cd was 3.1ng/m$^{3}$. The total cancer risk by these two metals for the inhalation route was estimated to be about 7.2.times.10$^{-6}$ . This order-of-magnitude risk estimate suggests that the ingalation risk in the study area from all carcinogenic metals including As and Ni (subsulfide) might exceed the acceptable risk criteria of 10$^{-5}$ -10$^{-6}$ by U.S.EPA.For a better risk assessment in the future, alveolar deposition of PM-10 in the study area were also discussed and an assessment was done.

  • PDF

유기성 폐기물 자원화 시설에서 발생되는 부유 세균의 분포 특성 (Distribution Characteristics of Airborne Bacteria in Organic-Waste Resource Facilities)

  • 김기연;고한종;김대근
    • 한국환경보건학회지
    • /
    • 제38권2호
    • /
    • pp.151-158
    • /
    • 2012
  • Objectives: Bioaerosols released by treating organic-waste resources cause a variety of environmental and hygiene problems. The objective of this study was to investigate the distribution characteristics of the airborne bacteria emitted from a pig manure composting plant, a principal site for organic-waste resource facilities. Methods: Three types of pig manure composting plant were selected based on fermentation mode: screw type, rotary type and natural-dry type. Each site was visited and investigated on a monthly basis between September 2009 and August 2010. A total of 36 air samplings were obtained from the pig manure composting plants. The air sampling equipment was a six-stage cascade impactor. Quantification and qualification of airborne bacteria in the air samples was performed by agar culture method and identification technique, respectively. Results: The mean concentrations of airborne bacteria in pig manure composting plant were 7,032 (${\pm}1,496$) CFU $m^{-3}$ for screw type, 3,309 (${\pm}1,320$) CFU $m^{-3}$ for rotary type, and 5,580 (${\pm}1,106$) CFU $m^{-3}$ for natural dry type. The screw type pig manure composting plant showed the highest concentration of airborne bacteria, followed by the natural dry type and the rotary type. The ratio of respirable to total airborne bacteria was approximately 40-60%. The predominant genera of airborne bacteria identified were Micrococcus spp., Staphylococcus spp. and Escherichia spp. Conclusion: Monthly levels of airborne bacteria were highest in August and lowest in November regardless of fermentation mode. There was no significant correlation relationship between airborne bacteria and environmental factors such as temperature, relative humidity and particulate matters in pig manure composting plants.