Abstract
In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house were evaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit considering seasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10, PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgent to develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summer season were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing no significant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.
Keywords
Ammonia; layer; inhalable dust; $PM_{10}$; $PM_{2.5}$; respirable dust;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Takai, H., S. Pedersen, J. O. Johnsen, J. H. M. Metz, P. W. G. Groot Koerkamp, G. H. Uenk, V. R. Phillips, M. R. Holden, R. W. Sneath, J. L. Short, R. P. White, J. Hartung, J. Seedorf, M. Schroder, K. H. Linkert, and C. M. Wathes, 1998. Concentration and emissions of airborne dust in livestock buildings in northern Europe. Journal of Agricultural Engineering Research 70: 59-77. doi:10.1006/jaer.1997.0280.   DOI
2 Kwon, K. S., I. B. Lee, and T. H. Ha, 2016. Identification of key factors for dust generation in a nursery pig house and evaluation of dust reduction efficiency using a CFD technique. Biosystems Engineering 151: 28-52. doi:10.1016/j.biosystemseng.2016.08.020.   DOI
3 Jang, D. H., K. S. Kwon, J. B. Kim, J. K. Kim, K. Y. Yang, S. M. Choi, and Y. N. Jang, 2021. Investigation and analysis of particulate-matters and ammonia concentrations in mechanically ventilated broiler house according to seasonal change, measurement locations and age of broilers. Journal of the Korean Society of Agricultural Engineers 63(1): 75-87 (in Korean). doi:10.5389/KSAE.2021.63.1.075.   DOI
4 Cambra-Lopez, M., A. J. Aarnink, Y. Zhao, S. Calvet, and A. G. Torres, 2010. Airborne particulate matter from livestock production systems: A review of an air pollution problem. Environmental Pollution 158(1): 1-17. doi:10.1016/j.envpol.2009.07.011.   DOI
5 Donham, K. J., S. J. Reynolds, P. Whitten, J. A. Merchant, and L. Burmeister, 1995. Respiratory dysfunction in swine production facility worker: Dose-response relationship of environmental exposure and pulmonary function. American Journal in Medicine 27: 405-418. doi:10.1002/ajim.4700270309.   DOI
6 Donham, K. J., and D. Cumro, 1999. Setting maximum dust exposure levels for people and animals in livestock facilities. Dust Control in Animal Production Facilities (Scandinavian Congress Center) 93-110.
7 Ellen, H. H., R. W. Bottcher, E. Von Wachenfelt, and H. Takai, 2000. Dust levels and control methods in poultry houses. Journal of Agricultural Safety and Health 6(4): 275-282. doi:10.13031/2013.1910.   DOI
8 EMEP/CORINAIR, 1999. Atmospheric emission inventory guidebook -second edition.
9 International VERA Secretariat, 2018. VERA test protocol forlivestock housing and management systems: Version 3: 2018-09. https://www.vera-verification.eu/app/uploads/sites/9/2019/05/VERA_Testprotocol_Housing_v3_2018.pdf.
10 Kim, H. A., J. Y. Kim, K. M. Shin, J. H. Jo, K. Roque, G. H. Jo, and Y. Heo, 2013. Relationship between endotoxin level of in swine farm dust and cellular immunity of husbandry workers. Journal of Korean Society of Occupational and Environmental Hygiene 23(4): 393-401 (in Korean). doi:10.15269/JKSOEH.2013.23.4.393.   DOI
11 Jo, Y. S., K. S. Kwon, I. B. Lee, T . H. Ha, S. J. Park, R. W. Kim, U. H. Yeo, S. Y. Lee, and S. N. Lee, 2015. Measurement of dust concentration in a naturally ventilated broiler house according to season and worker's access. Journal of the Korean Society of Agricultural Engineers 57(6): 35-46 (in Korean). doi:10.5389/KSAE.2015.57.6.035.   DOI
12 Kwon, K. S., Y. S. Jo, I. B. Lee, T . H. Ha, and S. W. Hong, 2014. Measurement of dust concentration in a mechanically ventilated broiler house and analysis of dust generation from ground beds. Journal of the Korean Society of Agricultural Engineers 56(6): 31-43 (in Korean). doi:10.5389/KSAE.2014.56.6.031.   DOI
13 US EPA, 1994. Measuring air quality: The pollutant standards index. United States Environmental Protection Agency.
14 Mitchell, B. W., R. J. Buhr, M. E. Berrang, J. S. Bailey, and N. A. Cox, 2002. Reducing airborne pathogens, dust and Salmonella transmission in experimental hatching cabinets using an electrostatic space charge system. Poultry Science 81(1): 49-55. doi:10.1093/ps/81.1.49.   DOI
15 National Institute of Environmental Research, 2019. National air pollutants emission 2006.
16 Qi, R., H. B. Manbeck, and R. G. Maghirang, 1992. Dust net generation rate in a poultry layer house. Transactions of the ASAE 35(5): 1639-1645 doi:10.13031/2013.28778.   DOI
17 Radon, K., C. Weber, M. Iversen, B. Danuser, S. Pedersen, and D. Nowak, 2001. Exposure assessment and lung function in pig and poultry farmers. Occupational and Environmental Medicine 58(6): 405-410. doi:10.1136/oem.58.6.405.   DOI