DOI QR코드

DOI QR Code

Distribution Characteristics of Airborne Bacteria in Organic-Waste Resource Facilities

유기성 폐기물 자원화 시설에서 발생되는 부유 세균의 분포 특성

  • Kim, Ki-Youn (Department of Industrial Health, Catholic University of Pusan) ;
  • Ko, Han-Jong (Division of Livestock Policy, Jeju Special Self-Governing Province) ;
  • Kim, Dae-Keun (Department of Environmental Engineering, Seoul National University of Science and Technology)
  • 김기연 (부산가톨릭대학교 산업보건학과) ;
  • 고한종 (제주도청 축산정책과) ;
  • 김대근 (서울과학기술대학교 환경공학과)
  • Received : 2011.08.19
  • Accepted : 2012.04.02
  • Published : 2012.04.30

Abstract

Objectives: Bioaerosols released by treating organic-waste resources cause a variety of environmental and hygiene problems. The objective of this study was to investigate the distribution characteristics of the airborne bacteria emitted from a pig manure composting plant, a principal site for organic-waste resource facilities. Methods: Three types of pig manure composting plant were selected based on fermentation mode: screw type, rotary type and natural-dry type. Each site was visited and investigated on a monthly basis between September 2009 and August 2010. A total of 36 air samplings were obtained from the pig manure composting plants. The air sampling equipment was a six-stage cascade impactor. Quantification and qualification of airborne bacteria in the air samples was performed by agar culture method and identification technique, respectively. Results: The mean concentrations of airborne bacteria in pig manure composting plant were 7,032 (${\pm}1,496$) CFU $m^{-3}$ for screw type, 3,309 (${\pm}1,320$) CFU $m^{-3}$ for rotary type, and 5,580 (${\pm}1,106$) CFU $m^{-3}$ for natural dry type. The screw type pig manure composting plant showed the highest concentration of airborne bacteria, followed by the natural dry type and the rotary type. The ratio of respirable to total airborne bacteria was approximately 40-60%. The predominant genera of airborne bacteria identified were Micrococcus spp., Staphylococcus spp. and Escherichia spp. Conclusion: Monthly levels of airborne bacteria were highest in August and lowest in November regardless of fermentation mode. There was no significant correlation relationship between airborne bacteria and environmental factors such as temperature, relative humidity and particulate matters in pig manure composting plants.

Keywords

References

  1. Lee SH, Ahn SW. Analysis of the available potential volumes of waste resources energy and the policy direction in Korea. J KSWM. 2011; 28(3): 249- 259.
  2. Fracchia L, Pietronave S, Rinaldi M, Martinotti MG. The assessment of airborne bacterial contamination in three composting plants revealed siterelated biological hazard and seasonal variations. J Appl Microbiol. 2006; 100: 973-984. https://doi.org/10.1111/j.1365-2672.2006.02846.x
  3. Bruce JM, Sommer M. Environmental aspects of respiratory disease in intensive pig and poultry houses, Including the implications for human health. Proceedings EC Meeting Aberdeen, EC Commission Publications, Brussels, 1987; 10: 29- 30.
  4. Olson DK, Bark SM. Health hazards affecting the animal confinement farm worker. Am Assoc Occup Health Nurse J. 1996; 44: 198-204.
  5. Seidl HP. Mikrobiologie des Abfalls. In: Keimbelastung in der Abfallwirtschaft: Tagung, 26/4/1995 ed. Mucke W, Seidl HP, Rakoski AH, Eckrich C, Emmerling G, Pipke R, Wimmer M. 1995. p.5-30.
  6. Fischer G, Muller T, Ostrowski R, Dott W. Mycotoxins of Aspergillus Fumigatus in pure culture and in native bioaerosols from compost facilities. Chemosphere. 1999; 38: 1745-1755. https://doi.org/10.1016/S0045-6535(98)00391-9
  7. Hryhorczuk D, Curtis L, Schleff P, Chung J, Rizzo M, Lewis, C, et al. Bioaerosols emission from a suburban yard waste composting facility. Ann Agric Environ Med. 2001; 8: 177-185.
  8. Jager E, Ruden H, Zeschmar-Lahl B. Composting facilities. 2. Aerogenic microorganism content at different working areas of composting facilites. Zentralbl Hyg Umweltmed. 1994; 196: 367-379.
  9. Reinthaler FF, Marth E, Eibel U, Enayat U, Feenstra O, Kock M, et al. The assessment of airborne microorganisms in large-scale composting facilities and their immediate surroundings. Aerobiologia. 1997; 13: 167-175. https://doi.org/10.1007/BF02694504
  10. Sachez-Monedero MA, Stentiford EI. Generation and dispersion of airborne microorganisms from composting facilities. Process Saf Environ. 2003; 81: 166-170. https://doi.org/10.1205/095758203765639861
  11. Grisoli P, Rodolfi M, Villani S, Grignani E, Cottica D, Berri A, et al. Assessment of airborne microorganism contamination in an industrial area characterized by an open composting facility and wastewater treatment. Environ Res. 2009; 109: 135-142. https://doi.org/10.1016/j.envres.2008.11.001
  12. Jones AM, Harrison RM. The effects of meteorological factors on atmospheric bioaerosol concentrations- a review. Sci Total Environ. 2004; 326: 151- 180. https://doi.org/10.1016/j.scitotenv.2003.11.021
  13. Folmsbee M, Strevett K. Bioaerosol concentration at an outdoor composting center. J Air Waste Manage Assoc. 1999; 49: 554-561. https://doi.org/10.1080/10473289.1999.10463824
  14. Tong Y, Lighthart B. Solar radiation has a lethal effect on natural populations of culturable outdoor atmospheric bacteria. Atmos Environ. 1997; 31: 897-900. https://doi.org/10.1016/S1352-2310(96)00235-X
  15. Kim KY, Park JB, Kim CN, Lee KJ. Distribution of airborne fungi, particulate matter and carbon dioxide in Seoul Metropolitan Subway stations. J Prev Med Public Health. 2006a; 39: 325-330.
  16. Kim KY, Park JB, Kim CN, Lee KJ. Assessment of airborne bacteria and particulate matters distributed in Seoul Metropolitan Subway stations. Kor J Environ Health. 2006b; 32: 254-261.
  17. Kim KY, Kim CN. Airborne microbiological characteristics in the public buildings of Korea. Building Environ. 2007; 42: 2188-2196. https://doi.org/10.1016/j.buildenv.2006.04.013
  18. Kim KY, Roh YM, Kim YS, Lee CM, Sim IS. Profile of airborne microorganisms distributed in general offices. general offices. J Kor Soc Occup Environ Hyg. 2008; 18: 11-19.
  19. Kim KY, Kim HT, Kim D, Nakajima J, Takashi H. Distribution characteristics of airborne bacteria and fungi in the feedstuff-manufacturing factories. J Hazard Mat. 2009; 169: 1054-1060. https://doi.org/10.1016/j.jhazmat.2009.04.059
  20. Kim KY, Ko HJ, Kim HT, Kim CN, Kim YS. Assessment of airborne bacteria and fungi in pig buildings in Korea. Biosys Eng. 2008; 99: 565-572. https://doi.org/10.1016/j.biosystemseng.2007.12.006
  21. Byeon JH, Park CW, Yoon KY, Park JH, Hwang J. Size distributions of total airborne particles and bioaerosols in a municipal composting facility. Bioresour Technol. 2008; 99: 5150-5154. https://doi.org/10.1016/j.biortech.2007.09.014
  22. Lee CM, Kim YS, Lee TH, Park WS, Hong SC. Characterization of airborne bioaerosol concentration in public facilities. Kor J Environ Sci. 2004; 13: 215-222.
  23. Kim KY, Kim YS, Kim D. Distribution characteristics of airborne bacteria and fungi in the general hospitals of Korea. Ind Health. 2010; 48: 236-243. https://doi.org/10.2486/indhealth.48.236
  24. Marthi B, Lighthart B. Effects of betaine on the enumeration of airborne bacteria. Appl Environ Microbiol. 1990; 56: 1286-1289.
  25. Walter MV, Marthi B, Fieland VP, Ganio LM. Effect of aerosolization on subsequent bacterial survival. Appl Environ Microbiol. 1990; 56: 3468- 3472.
  26. Macher JM, Huang FY, Flores M. A two-year study of microbiological indoor air quality in a newapartment. Arch Environ Health. 1991; 46: 25-29. https://doi.org/10.1080/00039896.1991.9937425
  27. Li CS, Hsu LY. Home dampness and childhood respiratory symptoms in a subtropical climate. Arch Environ Health. 1996; 51: 42-46. https://doi.org/10.1080/00039896.1996.9935992
  28. Kim KY, Ko HJ, Lee KJ, Park JB, Kim CN. Temporal and spatial distribution of aerial contaminants in an enclosed pig building in winter. Environ Res. 2005; 99: 150-157. https://doi.org/10.1016/j.envres.2004.10.004
  29. DeKoster JA, Thorne PS. Bioaerosol concentrations in noncomplaint, complaint and intervention homes in the Midwest. Am Ind Hyg Assoc J. 1995; 56: 576-580.
  30. Gorny RL, Dutkiewicz J, Krysinska-Traczyk E. Size distribution of bacterial and fungal bioaerosols in indoor air. Ann Agric Environ Med. 1999; 6: 105- 113.
  31. Pastuszka JS, Paw UKT, Lis DO, Wlazlo A, Ulfig K. Bacterial and fungal aerosol in indoor environment in Upper Silesia, Poland. Atmos Environ. 2000; 34: 3833-3842. https://doi.org/10.1016/S1352-2310(99)00527-0
  32. Gorny RL, Dutkiewicz J, Krysinska-Traczyk E. Size distribution of bacterial and fungal bioaerosols in indoor air. Ann Agric Environ Med. 1999; 6: 105- 113.