• Title/Summary/Keyword: resonance evaluation

Search Result 847, Processing Time 0.03 seconds

A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling (3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램)

  • Perez, Marlon;Hernandez, Daniel;Michel, Eric;Cho, Min Hyoung;Lee, Soo Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.107-119
    • /
    • 2014
  • Purpose : To efficiently evaluate phased array coil performance using a software tool box with which we can make visual comparison of the sensitivity of every coil element between the real experiment and EM simulation. Materials and Methods: We have developed a $C^{{+}{+}}$- and MATLAB-based software tool called Phased Array Coil Evaluator (PACE). PACE has the following functions: Building 3D models of the coil elements, importing the FDTD simulation results, and visualizing the coil sensitivity of each coil element on the ordinary Cartesian coordinate and the relative coil position coordinate. To build a 3D model of the phased array coil, we used an electromagnetic 3D tracker in a stylus form. After making the 3D model, we imported the 3D model into the FDTD electromagnetic field simulation tool. Results: An accurate comparison between the coil sensitivity simulation and real experiment on the tool box platform has been made through fine matching of the simulation and real experiment with aids of the 3D tracker. In the simulation and experiment, we used a 36-channel helmet-style phased array coil. At the 3D MRI data acquisition using the spoiled gradient echo sequence, we used the uniform cylindrical phantom that had the same geometry as the one in the FDTD simulation. In the tool box, we can conveniently choose the coil element of interest and we can compare the coil sensitivities element-by-element of the phased array coil. Conclusion: We expect the tool box can be greatly used for developing phased array coils of new geometry or for periodic maintenance of phased array coils in a more accurate and consistent manner.

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Quantitative Conductivity Estimation Error due to Statistical Noise in Complex $B_1{^+}$ Map (정량적 도전율측정의 오차와 $B_1{^+}$ map의 노이즈에 관한 분석)

  • Shin, Jaewook;Lee, Joonsung;Kim, Min-Oh;Choi, Narae;Seo, Jin Keun;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.303-313
    • /
    • 2014
  • Purpose : In-vivo conductivity reconstruction using transmit field ($B_1{^+}$) information of MRI was proposed. We assessed the accuracy of conductivity reconstruction in the presence of statistical noise in complex $B_1{^+}$ map and provided a parametric model of the conductivity-to-noise ratio value. Materials and Methods: The $B_1{^+}$ distribution was simulated for a cylindrical phantom model. By adding complex Gaussian noise to the simulated $B_1{^+}$ map, quantitative conductivity estimation error was evaluated. The quantitative evaluation process was repeated over several different parameters such as Larmor frequency, object radius and SNR of $B_1{^+}$ map. A parametric model for the conductivity-to-noise ratio was developed according to these various parameters. Results: According to the simulation results, conductivity estimation is more sensitive to statistical noise in $B_1{^+}$ phase than to noise in $B_1{^+}$ magnitude. The conductivity estimate of the object of interest does not depend on the external object surrounding it. The conductivity-to-noise ratio is proportional to the signal-to-noise ratio of the $B_1{^+}$ map, Larmor frequency, the conductivity value itself and the number of averaged pixels. To estimate accurate conductivity value of the targeted tissue, SNR of $B_1{^+}$ map and adequate filtering size have to be taken into account for conductivity reconstruction process. In addition, the simulation result was verified at 3T conventional MRI scanner. Conclusion: Through all these relationships, quantitative conductivity estimation error due to statistical noise in $B_1{^+}$ map is modeled. By using this model, further issues regarding filtering and reconstruction algorithms can be investigated for MREPT.

Usefulness of MRCP in the Diagnosis of Common Bile Duct Dilatation caused by Non-stone or Non-tumorous Conditions (비결석, 비종양성 총담관 확장의 진단에 있어서 자기공명담췌관조영술(MRCP)의 유용성)

  • 정재준;양희철;김명진;김주희;이종태;유형식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2002
  • Purpose : To evaluate the usefulness of MRCP in the diagnosis of the variable causes of common bile duct(CBD) dilatation, except stone or tumor Materials and methods : Twenty-six patients(M:F=15:11, mean age; 62 years) with both MRCP and ERCP were included in this study. Dynamic MRCP(n=12) and contrast-enhanced MRI(n=10) of abdomen were also added. Dilatation of CBD, intrahepatic ducts and pancreatic duct was evaluated, including coexistence of intrahepatic ductal stone, pancreatic pseudocyst, and papillary or papillary edema. The criteria of CBD dilatation was over than 7mm(n= 21, without cholecystectomy) or 10 mm(n=5, with cholecystecto-my) in diameter on T2-weighted coronal image. Results : The mean diameter of CBD was 12.7mm without cholecystectomy(9-19 mm) and 13.0 mm with cholecystectomy(10-15mm), respectively(p 〉0.05). Cholangitis(n=11, 42.3%), chronic pancreatitis(n=8, 30.8%), stenosis of distal CBD(n= 6, 23.1%), periampullary diverticulum(n=3, 11.5%), stenosis of ampulla of Vater(n=2, 7.7%), dysfunction of sphincter of Oddi(n=2, 7.7%), acute focal pancreatitis in the pancreatic head(n=2, 7.7%), papillitis(n=1, 3.8%), pseudocyst in the pancre atic head(n = 1, 3.8%), and ascaris in CBD(n=1, 3.8%) were noted. Pancreatic duct dilatation(n=10, 38.5%) and duodenal diverticulum(n=3, 11.5%) were also seen on MRC P. On dynamic MRCP(12 patients), distal CBD was visualized in 2 patients(16.7%), which was not shown on routine MRCP. Only 1 patient(10.0%) showed papillitis with slightly enhancing papilla on contrast-enhanced MRI (10 patients). Conclusion : MRCP was thought to be helpful in the evaluation of the causes of CBD dilatation, not caused by stone or tumor, especially in the cases of stenosis of distal CBD and chronic pancreatitis, dysfunction of sphincter of Oddi on dynamic MRCP and cholangitis and pericholangitic abnormality on contrast-enhanced MRI.

  • PDF

The Usefulness of MRCP in the Evaluation of Pancreaticobiliary Diseases in Children (소아에서 담췌관 질환에 대한 자기공명 담췌관조영술의 진단적 유용성)

  • Uhm, Ji Hyun;Lee, Seung Yeon;Chung, Ki Sup
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.11
    • /
    • pp.1381-1388
    • /
    • 2002
  • Purpose : Magnetic resonance cholangiopancreatography(MRCP) is a noninvasive method for imaging the pancreaticobiliary tree. The aim of this study was to evalute the usefulness of MRCP for the diagnosis of pancreaticobiliary diseases in children. Methods : From October 1996 to May 2001, 67 patients with obstructive jaundice and three patients with chronic recurrent pancreatitis were evaluated with abdominal ultrasonography and MRCP. The final diagnosis was based on the operative and pathologic findings with biopsy specimen including clinical and laboratory findings. Results : A total of 70 patients, consisting of 31 males and 39 females, with a mean age of $2.6{\pm}3.3$ years were studied. The final diagnosis was biliary atresia in 25, neonatal cholestasis in 18, choledochal cyst without anomalous pancreatobiliary duct union(APBDU) in nine, choledochal cyst with APBDU in seven, cholestatic hepatitis in five, chronic recurrent pancreatitis in three, sclerosing cholangitis in two, and secondary biliary cirrhosis in one case. The overall diagnostic accuracy of abdominal ultrasonography was 75.7% and that of MRCP was 97.1%. The sensitivity and specificity of MRCP were 100% and 98% for biliary atresia, 87.5% and 100% for choledochal cyst with APBDU, 100% and 100% for choledochal cyst without APBDU, sclerosing cholangitis and chronic recurrent pancreatitis, respectively. Conclusion : MRCP is a fast, non-invasive and reliable method for diagnosing pancreaticobiliary diseases in children and will be the standard diagnostic procedure in the future.

Evaluation of Glioma with Thallium-201 Brain SPECT: The Correlation with $^1H$ MR Spectroscopy and Pathology ($^{201}Tl$ 뇌 SPECT을 이용한 신경교종의 평가)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Yong-An;Chung, Soo-Kyo;Hong, Yong-Gil;Lee, Youn-Soo;Choe, Bo-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.465-477
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT and proton ($^1H$) magnetic resonance spectroscopy (MRS) have been used to evaluate tumor grade and viability of glioma. We assessed the correlations between $^{201}Tl$ brain index or spectrum of metabolites of $^1H$ MRS and grade of glioma or histopathologic findings. Materials and Methods: We studied 17 patients (4 astrocytoma, 7 anaplastic astrocytoma and 6 glioblastoma). On $^{201}Tl$ Brain SPECT, $^{201}Tl$ index was measured as the ratio of average counts for region of interest to those for the contralateral normal brain. On $^1H$ MRS, we calculated choline (Cho) /creatine (Cr) ratio and N-acetylaspartate (NAA)/Cr ratio in ROI defined as tumor center. Histopathologic findings were graded by Ki-67 index, cellularity, mitosis, pleomorphism, necrosis and endothelial proliferation. An unpaired t test and statistical correlations were performed to evaluate these data. Results: Tl-index showed the best correlation with Ki-67 index (p<0.01), less correlations with cellularity, mitosis, and endothelial proliferation, but no correlation with results of MRS, pleomorphism, or necrosis. The findings of MRS did not correlate with all of the above. The cases of glioblastoma demonstrated a higher Tl-index, Cho/cr ratio, Ki-67 index and lower NAA/Cr ratio, albeit without statistical significance. Conclusion: Even though $^{201}Tl$ brain SPECT did not correlate directly with grade of malignancy, it may still be useful in determining biological aggressiveness of tumor and prognosis of patients because it correlated well with Ki-67 index, a growth fraction of glioma, cellularity, mitosis and endothelial proliferation.

  • PDF

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Evaluation of Usefulness of SPIO (Superparamagnetic iron oxide) Contrast Agent in MRCP (Magnetic resonance cholangiopancreatography) (자기공명 담도췌장조영술에서의 SPIO 조영제의 유용성 평가)

  • Hong, In-Sik;Lee, Hae-Kak;Cho, Jae-Hwan;Kim, Hyeon-Ju;Jang, Hyun-Cheol;Park, Cheol-Soo;Lee, Sun-Yeob;Goo, Eun-Hoe;Dong, Kyung-Rae;Cho, Moo-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.143-148
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of SPIO contrast agent in Magnetic Resonance Cholangiopancreatography (MRCP) by performing a quantitative comparative analysis in patients undergoing MRCP for gallbladder stones with and without oral injection of SPIO (Superparamagnetic iron oxide) contrast agent. The subjects were 36 patients undergoing MRCP for suspected gallbladder stones between January 2009 and February 2010 and they were divided into halves to compare the two groups of with and without SPIO agent. For each subject in both the injected and non-injected group, T2-weighted images on a 1.5T MR scanner were obtained, using both the breath-holding and respiratory-triggered methods, respectively. The following regions were measured; for breath-hold T2-weighted images, the measurement regions were located at the central part of the gallbladder, and the areas 15 mm away from its center, toward the front and back, respectively, which were chosen to include surrounding tissues, while for respiratory-triggered T2-weighted images, at the central part of the gallbladder, and segment 5 and 6 of liver. In a quantitative analysis, average signal to noise ratio (SNR) in each of regions of interest (ROI) for each group were calculated and then average contrast to noise ratio (CNR) in each of ROI were obtained by using the SNR in the gallbladder as the basis to compare and analyze the values between the two groups. The CNR were higher for the injected group in those regions.

The Clinical Study of Hemoptysis in Lung Disease (객혈을 주소로 입원한 환자의 임상적 고찰)

  • Lee, Hyang-Ju;Um, Hye-Suk;Kim, Jung-Tae;Cho, Dong-Ill;Rhu, Nam-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.760-773
    • /
    • 2000
  • Background : Hemoptysis is a common clinical symptom responsible for 11% of admission to the hospital chest service. In KOREA pulmonary tuberculosis is still the most common cause of hemoptysis and the incidence of hemoptysis due to neoplasia has increased. Bronchoscopy and high resonance CT are essential for diagnosis of the cause of hemoptysis. We studied the causes, diagnostic tools and treament treatment of hemoptysis Methods : We conducted a retrospective analysis of clinical profiles, radiologic and bronchoscopy findings and treatments of hemoptysis for 220 patients who were admitted to our hospital with hemoptysis between 1994 and 1998. Results : The mean age at diagnosis was 49.3 years and male to female ratio was 2.1 : 1. The main causes were active pulmonary pulmonary tuberculosis in 72 cases(32.7%), inactive pulmonary tuberculosis with sequlae in 69 cases(31.4%) lung cancer in 43 cases(19.5%), bronchiectasis in 10 cases(4.5%), and chronic bronchitis in 10 cases(4.5%). The mean amount of hemoptysis for 24hrs was 120cc. The mean duration of bleeding was 25 days. The number of cases with a past history of pulmonary tuberculosis were 128 cases, in which 24 were relapsed tuberculosis cases, 25 chronic tuberculosis cases, 69 inactive tuberculosis cases, and 10 lung cancer cases. High resonance CT was the most useful method for structural etiologic evaluation of hemoptysis developed in patients with inactive tuberculosis, bronchiectasis and aspergilloma. Sputum study and bronchofiberscopy were the confirmative diagnostic tools for active pulmonary tuberculosis and lung cancer. The treatments of hemoptysis medical in 152 cases(71.7%), bronchial arteη embolization in 39 cases(17.8%), and operation in 9 cases(4.0%). The mean following up duration was 22.4 months. The overall outcomes of hemoptysis were controlled in 77 cases(43.5%), rebleeding in 100 cases (56.5%) and expired in 9 cases (4.0%). The outcomes of hemoptysis in pulmonary tuberculosis were controlled in 21.6%, rebleeding in 78.4%, and expire in 14.7%. Conculsion : The most common cause of hemoptysis was related with pulmonary tuberculosis. HRCT was an important diagnostic tool in AFB smear negative active pulmonary tuberculosis and inactive tuberculosis with sequelae. Early, proper management of pulmonary tuberculosis is important for prevention of hemoptysis in Korea.

  • PDF

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.