• 제목/요약/키워드: resistivity method

검색결과 1,211건 처리시간 0.025초

다양한 측정방법을 적용한 대지의 전기적 구조해석 (Electrical Structure Analysis of Ground using Various Methods for Resistivity Measurement)

  • 조성철;이태형;엄주홍;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1492-1493
    • /
    • 2006
  • Wenner 4-probe arrangement is used most widely by the method to measure soil resistivity and the measured data with the Wenner method are apparent resistivities of the soil. Therefore, the soil structure can be analyzed easily from the measured apparent resistivity, but the real soil resistivity is difficult to know correctly at a particular depth or at a specific location on earth surface. This paper introduces a method that can be used to decide the suitable burial depth and the electrode scale of a grounding rod effectively using soil structure analysis equipment based on the dipole-dipole method.

  • PDF

경계 요소법을 이용한 2차원 비저항 모델링 (Two-dimensional Resistivity Modeling Using Boundary Elements Method)

  • 김형수
    • 지질공학
    • /
    • 제6권3호
    • /
    • pp.119-130
    • /
    • 1996
  • 경계요소법을 이용한 2차원 전기비저항 모델링을 위한 이론적 전개와 수치계산 기술이 주어졌다. 균질 지하모델과 층상구조 지하모델에 대한 점전류전원에 대한 전위분포가 경계요소법을 이요하여 계산되으며, 그 결과는 동일 모델에 대해서 수행된 유한차분법, 유한요소법의 수치 결과와 비교 연구되었다. 경계요소법을 사용한 2차원 전기모델링은 저장용량, 계산속도 및 정확도에서 유한요소법이나 유한차분법에 비해 효율적임이 입증되었다.

  • PDF

Testing of the permeability of concrete box beam with ion transport method in service

  • Wang, Jia Chun
    • Computers and Concrete
    • /
    • 제15권3호
    • /
    • pp.461-471
    • /
    • 2015
  • The permeability is the most direct indicator to reflect the durability of concrete, and the testing methods based on external electric field can be used to evaluate concrete permeability rapidly. This study aims to use an experiment method to accurately predict the permeability of concrete box beam during service. The ion migration experiments and concrete surface resistivity are measured to evaluate permeability of five concrete box beams, and the relations between these results in service concrete and electric flux after 6 hours by ASTM C1202 in the laboratory are analyzed. The chloride diffusion coefficient of concrete, concrete surface resistivity and concrete 6 hours charge have good correlation relationship, which denote that the chloride diffusion coefficient and the surface resistivity of concrete are effective for evaluating the durability of concrete structures. The chloride diffusion coefficient of concrete is directly evaluated permeability of concrete box beam in service and may be used to predict the service life, which is fit to engineering applications and the concrete box beam is non-destructive. The concrete surface resistivity is easier available than the chloride diffusion coefficient, but it is directly not used to calculate the service life. Therefore the mathematical relation of the concrete surface resistivity and the concrete chloride diffusion coefficient need to be found, which the service life of reinforced concrete is obtained by the concrete surface resistivity.

붕락 터널에서의 3차원 전기비저항 탐사 (3D Resistivity Survey at a Collapsed Tunnel Site)

  • 조인기;김기석;이근수
    • 지구물리와물리탐사
    • /
    • 제18권1호
    • /
    • pp.14-20
    • /
    • 2015
  • 3차원 전기비저항 탐사법은 지하 전기비저항의 3차원적 분포 영상을 제공해 주므로 매우 효과적인 지반조사 방법 중의 하나이다. 본 연구에서는 붕락이 발생한 터널에 대하여 3차원 전기비저항 탐사를 수행하여 붕락의 원인으로 보이는 터널 주변의 파쇄대 및 석탄층의 발달 상황을 파악하고자 하였다. 이를 위하여 터널에 평행한 5개의 측선과, 수직한 11개의 측선에 대하여 2차원 전기비저항 탐사를 수행하고, 이들 자료를 통합하여 3차원 역산을 수행하였다. 역산 결과 얻어진 3차원 역산결과와 시추 자료를 종합하여 터널 붕락의 원인으로 해석되는 단층 파쇄대 및 탄층의 3차원적 분포 양상을 제시하였다.

선택적 증착에 의해서 제작한 ZnO 박막의 전기저항률 특성 (The Characteristic on Electrical Resistivity of Zno film by Ramped method)

  • 이우선;최권우;조준호;박진성;서용진;김상용;정용호;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.26-29
    • /
    • 2001
  • ZnO thin film had been deposited on the glass by Evaporation Ramped method. and electrical and resistivity were investigated. Evaporation gas($O_{2}$,) pressure was 10mTorr~100mTorr, chamber pressure was $2{\times}10^{-5}$, and then ZnO film were deposited. AI-doped ZnO thin film had the lowest resistivity ($1{\times}10^{4}\;{\Omega}{\cdot}cm$), and then carrier concentration and Hall mobility were$6.27{\times}10^{20}\;cm^{3}$ and $22.04 cm^{2}/V{\cdot}s$, respectively. When ZnO film had been deposited by Ramp6ed method compared with normal method and investigated resistivity.

  • PDF

표면파 분산특성과 전기비저항 분포특성에 대한 인접구조물의 영향 (Influence of Adjacent Structures on Surface-Wave Dispersion Characteristics and 2-D Resistivity Structure)

  • 조성호;김봉찬;조미라;김석철;윤대희;홍재호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1318-1327
    • /
    • 2008
  • Geotechnical sites in urban areas may have embedded structures such as utility lines and underground concrete structures, which cause difficulties in site investigation. This study is a preliminary research to establish knowledge base for developing an optimal technique for site investigation in urban areas. Surface-wave method and resistivity survey, which are frequently adopted for non-destructive site-investigation for geotechnical sites, were investigated to characterize effects of adjacent structures. In case of surface wave method, patterns of wave propagation were investigated for typical sets of multi-layered geotechnical profiles by numerical simulation based on forward modeling theory and field experiments for small-size model tests and real-scale tests in the field. In case of resistivity survey, 3-D finite element analyses and field tests were performed to investigate effects of adjacent concrete structures. These theoretical and experimental researches for surface-wave method and resistivity survey resulted in establishing physical criteria to cause interference of adjacent structures in site investigation at urban areas.

  • PDF

소형루프 전자탐사에 의한 논 토양분석 (Analysis of Soil Properties in a Rice Field Using Small Loop EM Method)

  • 용환호;송성호;김진호;조인기
    • 지구물리와물리탐사
    • /
    • 제6권4호
    • /
    • pp.207-214
    • /
    • 2003
  • 논 토양의 심도별 물리적 특성 분석을 목적으로 토양시료의 분석에 의한 전기비저항과 소형루프 전자탐사 자료의 1차원 역산에 의한 전기비저항 자료를 비교하였다. 비록 두 결과가 정확히 일치하지는 않았지만, 토양시료분석에서 나타난 저비저항대는 소형루프 전자탐사 결과에서도 저비저항 이상대로 나타났다. 따라서 소형루프 전자탐사법은 염류집적과 같은 토양 특성 파악에 사용 가능할 것으로 생각된다. 향후, 불포화대 토양특성과 전자탐사에 관한 연구가 지속된다면, 소형루프 전자탐사법은 농업용 토지의 염류 분포 파악에 매우 효과적일 것으로 기대된다.

전기비저항 탐사시 지하매설물에 의한 간섭효과 연구 (Interference effect by underground utilities at electric resistivity Survey)

  • 김재홍;오병현;임은상;이종욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.961-965
    • /
    • 2009
  • Using much electric resistivity survey to design or preservation administration of facilities. However, By survey method that electric resistivity survey grasps special quality in base by potential difference creating artificial current in underground, Is influenced in electric resistance propensitys of various underground utilities in base. This Study selects dam 1 place that could grasp well underground situation and studied electricity interference effect by effect of underground utilities. Grasp underground utilities of dam interior, and control and observed accuracy with survey wave because various pole space. Through this Study, wish to present survey method of electric resistivity survey at design or survey of preservation administration dimension after with drawn result.

  • PDF

Estimation of kernel function using the measured apparent earth resistivity

  • Kim, Ho-Chan;Boo, Chang-Jin;Kang, Min-Jae
    • International journal of advanced smart convergence
    • /
    • 제9권3호
    • /
    • pp.97-104
    • /
    • 2020
  • In this paper, we propose a method to derive the kernel function directly from the measured apparent earth resistivity. At this time, the kernel function is obtained through the process of solving a nonlinear system. Nonlinear systems with many variables are difficult to solve. This paper also introduces a method for converting nonlinear derived systems to linear systems. The kernel function is a function of the depth and resistance of the Earth's layer. Being able to derive an accurate kernel function means that we can estimate the earth parameters i.e. layer depth and resistivity. We also use various Earth models as simulation examples to validate the proposed method.

역전파알고리즘을 이용한 대피저항율추정에 관한 연구 (A Study on the Estimation of Earth Resistivity using Backpropagation Algorithm)

  • 박경열;유보혁;석진욱;최종기;정길조;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.203-205
    • /
    • 1997
  • In this paper, we present a useful method of estimating earth resistivity using BP algorithm in Neural-Networks. From this method, equivalent earth resistivity(EER) can be obtained directly using training data composed of field-measured apparent resistivity and probe distance. This approach can reduce errors which is conventionally raised from manual operation of calculating EER. To evaluate its accuracy and convenience, the result of proposed method is compared to that of conventional methods, graphical($\rho$-a graph) and numerical(CDEGS program), respectively.

  • PDF