• 제목/요약/키워드: resin matrix

검색결과 456건 처리시간 0.023초

Microfill, Hybrid 복합레진 연마 후 표면조도와 광반사율에 관한 연구 (A STUDY ON THE SURFACE ROUGHNESS AND REFLECTIVITY AFTER POLISHING OF THE MICROFILL, HYBRID COMPOSITE RESINS)

  • 문은재;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.513-533
    • /
    • 1994
  • The smooth surface after polishing of composite resin contributes to the patient's comfort, and appearance and longevity of the restoration. This study was performed for the quantitative analysis of the effects of the various finishing and polishing instruments on the surface roughness and reflectivity of the microfill, and hybrid composite resins. Cylindrical specimens 2mm thick and 10mm in diameter of Silux Plus, Durafill VS ; Z100, Prisma TPH, Brilliant, and Herculite XR composite resin were polymerized under the matrix strip. 18 specimens for each composite resin materials were divided into 6 groups ; 5 experimental groups were abraded with # 600 sand paper to remove resin-rich layer, except control. Thereafter, using diamond bur(Mani Dia-Burs), carbide bur(E. T. carbide set 4159), rubber point(Composite polishing kit), aluminum-oxide disk(Sof-Lex disk), polishing paste(Enhance system) ; each specimen was polished to its best achievable surface according to manufacturer's directions. Final polished surfaces were evaluated for the surface roughness with profilometer(${\alpha}$-step 200, Tencor instruments, USA) and for the reflectivity with image analyser(Omniment Image Analyser, Buehler, USA). The results were as follows. 1. Polishing paste or aluminum-oxide disk finish in the microfill, and hybrid composite resins was as smooth as matrix strip finish on the surface roughness test. 2. Polishing paste or aluminum-oxide disk finish in the microfill ; polishing paste finish in the hybrid composite resins was as reflective as matrix strip finish on the refectivity test. 3. For the polishing paste, there were no significant differences between the composite resin materials on the surface roughness and refectivity tests. 4. For the aluminum-oxide disk, the best result was obtained with the microfill composite resin on the surface roughness and reflectivity test. 5. Diamond bur, carbide bur, and rubber point were inappropriate for the final polishing instruments.

  • PDF

페놀수지 탄화 코팅법을 이용한 섬유강화 복합재료 계면 형성에 관한 연구 (Novel Phenol Resin Carbonizing Method for Carbon Interlayer Coating between Reinforcing Fiber and Matrix in Fiber Reinforced Ceramic Composite)

  • 김세영;우상국;한인섭
    • 한국세라믹학회지
    • /
    • 제46권3호
    • /
    • pp.301-305
    • /
    • 2009
  • The novel carbon coating process for interlayer of fiber reinforced ceramic composites between fiber and matrix was performed by carbonizing phenolic resin solution that coated on fiber surface in $N_2$ atmosphere at $600^{\circ}C$ to improve the strength and fracture toughness of CMC(ceramic matrix composite). 160 nm carbon layer was coated on fiber surface with 5 vol% of phenolic resin solution. Since the process temperature ($600^{\circ}C$) is lower than chemical vapor deposition($900{\sim}1000^{\circ}C$), the strength and toughness could be preserved. Furthermore the coating thickness uniformity was improved to 8% of deviation along the stacking sequence. Therefore, prevention from fiber degradation during coating process and controlling coating thickness uniformity along the preform depth were achieved by coating with phenolic resin carbonizing method.

수복용(修複用) 복합(復合)레진의 표면조도(表面粗度)에 관(關)한 연구(硏究) (A STUDY ON THE ROUGHNESS OF THE RESTORATIVE COMPOSITE RESIN)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제13권2호
    • /
    • pp.207-220
    • /
    • 1988
  • The purpose of this study was to measure roughness on the polished surfaces of composite resin, and was to observe the polished surfaces under Scanning Electron Microscope. The surface roughness tester (Surfcom 700A Semitsu Profilometer Tokyo. Japan) was used to measure roughness of polished surfaces. In this study, 4 brands of composite resin were examined, Pyrofil bond anterior Bell-Feel anterior Clearfil F II and Microrest A.P. White point, Silicone point, Super snap, and Sof-Lex medium disc as cutting instrument, and celluloid matrix were used. The results obtained were as follows. 1) The celluloid matrix produced the smoothest surfaces. 2) Microrest composite resin had smoother surface than any other composite resins after polishing. 3) The values of surface roughness made by White point, Silicon point and Super snap were similar. 4) The surfaces made by Sof-Lex medium disc was smoother than the surfaces made by any other polishing instruments.

  • PDF

난연.기능성 복합성형체 제조 및 특성

  • 현병민;강영구
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2002년도 춘계 학술논문발표회 논문집
    • /
    • pp.457-460
    • /
    • 2002
  • 현재 건축단열재, 흡음재, 바닥재로 사용되는 panel 성형, 제작하기 위해 다종의 유기고분자 matrix가 사용되고 있으며 polyurethane, vinyl acetate, urea-formaldehyde resin 또는 melamine-formaldehyde, phenol-form aldehyde resin 등을 사용하고 있으나 이러한 고분자 matrix를 사용한 건축용 panel의 경우 화재시 유독 gas와 더불어 급격한 화재전파의 매개체로 사용될 수 있어 난연제 첨가로 이러한 현상을 억제하고 있다.(중략)

  • PDF

Ferrite-Resin 복합재료의 방진 특성에 관한 연구 (Characteristics of Ferrite-Resin Material for Improving Vibration-proof Property)

  • Park, Y.I.;Maeng, H.Y.;Won, S.T.
    • 한국정밀공학회지
    • /
    • 제10권3호
    • /
    • pp.31-40
    • /
    • 1993
  • The vibration-proof material normally used in structural components of precision machinery or measuring instruments requires higher damping in vibration and better characteristics in dimensional stability and rigidity to accomplish the quality assurance of the products. In this study the ferrite-resin material, which is the mixture of epoxy resin and the oxidized steel (Fe$_{3}$O$_{4}$: ferrite) in consideration of characteristics of aggregator and binder, is developed and investigated as one of vibration-proof materials. Four kinds of composite plates for experiments are made by adding another filler materials such as steel powder, granite powder and carbon-fiber sheet to the basic ferrite-resin matrix. Their characteristics are compared with a cast iron specimen which has the same bending rigidity as other specimens. The ferrite-resin material gives the best damping effect in the motor-induced vibration test. Therefore, the material can be applied to the manufacturing industry for vibration damping of machine elements.

  • PDF

Novel thermoplastic toughening agents in epoxy matrix for vacuum infusion process manufactured composites

  • Bae, Jin-Seok;Bae, Jihye;Woo, Heeju;Lee, Bumjae;Jeong, Euigyung
    • Carbon letters
    • /
    • 제25권
    • /
    • pp.43-49
    • /
    • 2018
  • This study suggests the novel thermoplastic toughening agent, which can be applied in the monomer forms without increasing the viscosity of the epoxy resin and polymerized during the resin curing. The diazide (p-BAB) and dialkyne (SPB) compounds are synthesized and mixed with the epoxy resin and the carbon fiber reinforced epoxy composites are prepared using vacuum infusion process (VIP). Then, flexural and drop weight tests are performed to evaluate the improvement in the toughness of the prepared composites to investigate the potential of the novel toughening agent. When 10 phr of p-BAB and SPB is added, the flexural properties are improved, maintaining the modulus as well as the toughness is improved. Even with a small amount of polytriazolesulfone polymerized, due to the filtering effect of the solid SPB by the layered carbon fabrics during the VIP, the toughening and strengthening effect were observed from the novel toughening agent, which could be added in monomer forms, p-BAB and SPB. This suggests that the novel toughening agent has a potential to be used for the composites prepared from viscosity sensitive process, such as resin transfer molding and VIP.

알칼리와 고온노출에 의한 GFRP 보강근 손상에 대한 현미경분석 연구 (Optical Microscopic Image Analysis for Damaged GFRP Rebar by Alkali and High Temperature Exposures)

  • 배정명;문도영;박철우;박영환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.53-59
    • /
    • 2017
  • 본 연구에서는 고온에 노출된 GFRP 보강근과 고온에 노출된 후 알칼리용액에 노출된 보강근의 단면을 현미경을 통해 관찰하고 발생된 손상의 특징을 고찰하였다. 또한, 각 시험체에 발생한 레진 균열과 공극에 대한 정량적 분석을 실시하였다. 알칼리로 인한 손상은 주로 표면에 집중되며 레진균열과 작은 공극을 발생시키는 것으로 확인되었다. 고온노출에 의한 손상은 레진균열과 공극을 발생시키는 것은 알칼리와 동일하지만 전단면에서 발생하며, 공극의 크기가 훨씬 크다. 또한 정량분석 결과, 동일한 알칼리 용액 노출조건에도 불구하고, $200^{\circ}C$ 이상의 고온에 노출된 시편에서 발견된 레진 균열과 공극이 고온노출이력이 전혀 없는 보강근에서 발견된 것 보다 1.5 및 1.4배 큰 것으로 확인되었다. 그러므로 동일한 알칼리 노출 조건이라 할지라도 $200^{\circ}C$ 이상의 고온에 노출된 보강근은 고온노출이력이 없는 보강근에 비하여 레진의 열화가 가속화 될 가능성이 있음을 알 수 있다.

저점도 Bis-GMA 유도체로부터 제조된 고분자계 치과 수복용 복합재의 특성 (Characteristics of Polymeric Dental Restorative Composites Fabricated from Bis-GMA Derivatives Having Low Viscosity)

  • 전미영;송정오;김창근
    • 폴리머
    • /
    • 제31권6호
    • /
    • pp.491-496
    • /
    • 2007
  • 고분자계 치아 수복용 복합재에서 2,2-bis[4-(2-hydroxy-3-methacryloyloxy propoxy) phenyl] propane(Bis-GMA) 70 wt%와 희석제인 triethylene glycol dimethacrylate(TEGDMA)가 30 wt% 포함된 혼합물이 레진 기질로 사용되고 있다. Bis-GMA의 높은 점도로 인해 첨가되는 TEGDMA는 수복재의 높은 경화 수축과 물성 저하의 원인이 된다. 본 연구에서는 TEGDMA 첨가량을 감소시켜 우수한 특성을 나타내는 수복재를 제조하기 위해 저점도 Bis-GMA 유도체들을 이용하여 새로운 치과용 수복재를 제조하였다. 히드록실기를 포함하지 않는 Bis-GMA 유도체들의 경화 특성은 Bis-GMA와 비슷하였지만 이들의 흡습성과 점도는 Bis-GMA에 비해 크게 낮았다. Bis-GMA 유도체를 포함한 수복재를 제조하여 경화 수축률, 흡습성, 기계적 물성을 실험한 결과 기존 상업적으로 사용되는 수복재보다 낮은 흡습성과 탁월한 물성을 나타내었고, 경화 수축률도 약 25% 감소하였다.

Glass Fiber Post와 Composite Resin Core의 전단결합강도 (A STUDY FOR THE BONDING STRENGTH OF COMPOSITE RESIN CORE TO GLASS FIBER POST)

  • 김태형;심준성;이근우
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.415-425
    • /
    • 2005
  • Statement of problem : Fracture of composite resin core will be occulted by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitro study tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and cote complex. Materials and methods: 40 specimens made with glass fiber Posts(Style $post^{(R)}$, Metalor, Swiss) and composite resin core ($Z-100^{(R)}$, 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data. ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Evely analysis was approved with 95% reliance. Results: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group (p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. Conclusion: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.

유전기법을 이용한 복합재료 기지재의 경화 모니터링 (Cure monitoring of a composite matrix by dielectrometry)

  • 여권주;이상관;엄문광;황병선
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.110-113
    • /
    • 2001
  • Dielectrometry has been used to monitor the cure of epoxy resin using composite matrix. In this investigation, physical properties of the mixture of epoxy resin(LY564), bisphenol A type, and cycloaliphatic hardener(HY 2954) were observed. Activation energy at maximum tan $\delta$ and gelation point was determined during isothermal scanning. From IonViscosity data, it was found that vitrification peak after gelation was appeared on slow heating rate. It was also measured that the duration time for full cure was necessary and it was about 24 hr at $145^{\circ}C$. Therefore, epoxy resin used in this research is required the extended time for full cure.

  • PDF