• Title/Summary/Keyword: residual chlorine

Search Result 192, Processing Time 0.029 seconds

Phytoremediation of the pesticides, endosulfan (${\alpha}$ and ${\beta}$) and fenitrothion, using aquatic plants (수생식물을 이용한 엔도설판(${\alpha},\;{\beta}$) 및 페니트로치온의 제거)

  • Kim, Jong-Hyang;Lee, Bang-Hee;Hur, Jong-Sou;Lee, Geun-Seon;Koh, Sung-Cheol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.249-256
    • /
    • 2010
  • A phytoremediation study has been conducted to see if some known aquatic plants can remove the pesticides, endosulfan-${\alpha},\;{\beta}$ and fenitrothion which are frequently used in the crop protection and golf course management, and are likely to exist as residual pollutants in the aquatic ecosystems. Among the five aquatic plants tested in the microcosms, water lily Nymphaea tetragona Georgi showed the highest degradation efficacies (85~95%) for the three pesticides as opposed to the control(13~26%). The efficacies for the other plants were in the range of 46~80% in the order of Pistia stratiotes, Cyperus helferi, Eichhornia crassipes, and Iris pseudoacorus. Fenitrothion, an organo-phosphorus pesticide, was much more vulnerable to the phytoremediation than the organo-chlorine pesticides, endosulfan-${\alpha}$ and endosulfan-${\beta}$. The kinetic rate constants ($min^{-1}$) for removal of the three pesticides were more than 10 times higher than the control (non-planting) in case of Nymphaea tetragona Georgi. This aquatic plant showed kinetic rate constants about 2 times as much as the lower kinetic rate constants shown by Iris pseudoacorus. The reason for the highest degradation efficacy of water lily would be that the plant can live in the sediment and possess roots and broad leaves which could absorb or accumulate and degrade more pollutants in association with microbes. These results indicate that some of the selected aquatic plants planted near the agricultural lands and wetlands could contribute to remediation of pesticides present in these places, and could be applicable to protection of the aquatic ecosystems.

Study on Distribution of Microbes in Waterscape Facilities in Gyeonggi-do (경기도내 물놀이형 수경시설 중 미생물 분포 조사 연구)

  • Jeong, Ah-Yong;Park, Myoung-Ki;Kim, Yun-Sung;Lee, Chang-Hee;Lee, Jung-Hee;Lee, Hye-Yeoun;Kim, Young-Suk
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.710-718
    • /
    • 2020
  • Objectives: We analyzed water in waterscape facilities to investigate contamination levels of water-borne pathogens and four test items (pH, turbidity, residual chlorine, and Escherichia coli) at facilities including play fountains, splash parks, and artificial streams from June to October in Suwon City and in the whole of Gyeonggi-do. Methods: A total of 62 waterscape facility samples were collected from 36 sites and tested for pathogenic Escherichia coli and water-borne viruses that cause hand-foot-and-mouth disease, eye disease, and acute enteritis. Results: None of the water-borne pathogens were detected in waterscape facility samples collected from across Gyeonggi-do that were for pre-inspection for facility management. However, the results of samples from Suwon collected in hot weather and during the school vacation period showed five total inconsistencies in turbidity (four cases) and Escherichia coli (one case). Three out of the four inconsistent samples in turbidity were from the same facility which operated a sand filtration system due to its locational factors close to mountains. Conclusion: We suggest that the waterscape facilities in Gyeonggi-do are managed properly in the respect of microbial contamination and water quality.

Evaluation of Microbial Analysis and Application of Reduction Technology in a Dairy Factory (목장형 유가공장의 미생물 분석 및 저감기술 적용 평가)

  • Jong-Hui Kim;Eun-Seon Lee;Bu-Min Kim;Jun-Sang Ham;Mi-Hwa Oh
    • Journal of Dairy Science and Biotechnology
    • /
    • v.41 no.4
    • /
    • pp.203-210
    • /
    • 2023
  • Bacterial contamination negatively affects the quality, functionality, and safety of dairy products. Adherent populations of bacteria, referred to as biofilms, grow on the surfaces of dairy processing equipment and are the primary cause of dairy contamination. In addition, microorganisms present in the farm environment and dairy factory can contaminate the Clear-In-Place (CIP) line through raw milk transport pipes; therefore, exhaustive management is required. In dairy manufacturing facilities, biofilm formation is controlled using CIP systems that primarily require sodium hydroxide and nitric acid. However, the leakage or incomplete removal of these potently active compounds can be harmful to humans. In the present study, we compared the eradication of Escherichia coli and other bacteria using commercially available combinations of sodium hypochlorite (NaClO) and citric acid, which are recognized by the Korean Ministry of Food and Drug Safety (MFDS) as food disinfectants. When considered in the CIP system of the field manufacturing process, E. coli was not detected (compared to detection before treatment), and other bacteria were detected at 0-32 culture-forming units (CFU)/cm2. The residual amount of chlorine ions after CIP treatment was similar to that in tap water, and there was no significant difference in the overall components of the fermented dairy products. Therefore, the NaClO/citric acid CIP system can be safely applied in dairy manufacturing processes.

Harmful Chemicals Migrating from Plastic Hoses Using Household into Tap Water (가정용 고무호스에서의 유해화학물질 용출)

  • Bae, Seok-Mun;Son, Hee-Jong;Jeong, Hyun-Chul;Choi, Jin-Taek;Bin, Jae-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.900-904
    • /
    • 2010
  • Polyvinyl chloride (PVC) hoses, polyethylene hose and silicone hose for tap water were tested with respect to migration of phenolic compounds to water. The highest concentrations (0.36~1.97 mg/L) of total phenolic compounds were observed in the test water from PVC hoses. Increasing residual Cl concentration from 0 to 0.5 mg/L or increasing water temperature from 4 to $25^{\circ}C$ increased 3~3.2 times and 100~104 times for migrated total phenolic compounds concentrations, in respectively. A major migrating phenolic compounds from PVC hoses were bisphenol-a (BPA) and it was observed that the concentration of migrating phenolic compounds in the order: DEHP > 2-chlorophenol > 2,4,6-trichlorophenol > 2,4-dichlorophenol from PVC hoses.

Operation of Advanced Water Treatment Processes for Downstream River Source Water (상수원수의 고도정수처리 공정 파일롯 운전 연구)

  • Wang, Chang-Keun;Oh, Sang-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • Down Stream K River has high COD (4-10 mg/L) and high $NH_3$-N concentration (3.5 mg/L during winter period). Although $NH_3$-N itself is not reported harmful at this level, it must be removed to meet drinking water standard (0.5 mg/L). We constructed a pilot plant modifying the processes of conventional drinking water facilities. Prechlorination and powdered activated carbon (PAC) dechlorination was adopted prior to a flocculation tank to remove ammonia and prevent disinfection byproducts (DBPs) formation. Also, GAC processes was included after sand filter to remove residual DOC. This pilot having a capacity of 36 ton/day was operated for one year. The GAC processes were successful to remove ammonia and many organic pollutants (DOC, MBAS, UV-254 nm absorbance, etc). Influent DOC concentrations were very high as 3~6 mg/L throughout the plant operation. It was impossible to achieve 1.0 mg/L effluent DOC, indicating that bed depth (2 m) should be increased to achieve more strict DOC quality standards. When $Cl_2$ dose was well controlled ($Cl_2/NH_3$-N ratio 10~11 on a weight basis), $NH_3$-N removal was 98% and THMs was very low possibly due to low free residual chlorine and PAC dechlorination.

Studies on Sanitary Conditions in a Special Grade Chicken Processing Plant in Korea I. Storage Period of Packed Chicken Meat in relation to the Bacterial Contamination of Each Processing Part (특급도계장의 위생실태에 관한 연구 I. 작업부분별 세균오염도 측정)

  • 오경록
    • Korean Journal of Poultry Science
    • /
    • v.13 no.1
    • /
    • pp.41-48
    • /
    • 1986
  • In order to investigate the storage period of packed chicken meat in relation to the bacterial contamination of each processing part, a special grade poultry processing plant located at Dongdoochun-City, Gyeonggi-Do, was surveyed mainly in point of sanitary conditions. The results are summarized as follows. 1. processing room near reception and packing room next to shipping area showed the highest bacterial counts in air. 2. Equipments and instruments for slaughtering also showed a high degree of bacterial contamination even before the operation. This finding suggested that the possibility of the bacterial contamination of carcasses through equipments and instruments would be high, if the continuous sanitary control measures are not properly taken. 3. The bacterial count of scalding water was 3${\times}$10$\^$7/ for standard plate count and 4${\times}$10$\^$5/ for most probable number of coliform bacteria at 1 hour after the start of operation. These values were maintained until the completion of processing. 4. At the ending of chilling process, the bacterial counts of chilling water were 3.3 ${\times}$10$^4$ and 3.0${\times}$10$^3$for standard plate count, when the volume of water used per bird were 21 and 51, respectively. Bacterial contamination was further decreased about 10$\^$-3/-10$\^$-4/ times as the effective chlorine concentration in chilling water was maintained about 50 ppm. 5. An average standard plate count of the residual water In abdominal cavity of carcasses was 3.9${\times}$10$^4$immediate after chilling, however, it increased to 4.7${\times}$10$\^$7/ when the carcasses were packed and stored for 10 days at 4$^{\circ}C$. off-odour development was observed as the bacterial count was not less than 10$\^$6//$m\ell$ of the residual water of the packed carcasses. Data indicated that if the standard plate count of the residual water in abdominal cavity of carcasses was not less than l0$^4$immediate after chilling, the packed chicken meat would not be stored longer than 5 days at 4$^{\circ}C$.

  • PDF

Application of Electrochemical Technology for Reusing Biologically Treated Water (생물학적 처리수 재이용을 위한 전기화학 기술의 적용)

  • Kang, Gu-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.453-458
    • /
    • 2008
  • Laboratory experiments were conducted to investigate disinfection as well as removal of color and residual organics from reclaimed municipal wastewater by electrochemical processes with Nb/Pt anode installed. RNO was rapidly bleached by OH$\cdot$ and the second order rate constants of RNO removal were $\frac{0.223l}{mg{\cdot}min}$, $\frac{1.679l}{mg{\cdot}min}$ and $\frac{2.322l}{mg{\cdot}min}$ with for 5 A, 10 A, and 15 A, respectively, with r$^2$ of > 96%. In batch electrochemical processes, after 15 min at currency of 15 A and initial pH of 5, 7,5 and 9, COD$_{Mn}$ was below 4 mg/L, color unit below 5 degree and general bacteria was not detected, the concentration of which are suitable for drinking water regulation. In the continuous electrochemical process, with HRT of 3.7$\sim$49.2 min, free chlorine were 0.2$\sim$0.7 mg/L, general bacteria was not detected, color unit below 5 degree and THMs was 0.017 mg/L. Therefore, electrochemical process with Nb/Pt anode was employed satisfactory to meet for reusing biologically treated water as well as disinfection.

Ship Sewage Treatment Using Fixed Media Method (고정식 메디아법을 이용한 선박의 오폐수 처리)

  • Han, Sang-Hwa;Lee, Dea-Ho;Nyung, Bu-Nyung;Bae, Sang-Bum;Yoon, Jong-Mun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • The purpose of this study is to develop Sewage Treatment Plant that treat sewage which occurred in ship using fixed media method and to consider applicable to the Pilot Scale device of the STP regulations in MLTM(Ministry of Land, Transport and Maritime Affairs) and MEPC(Marine Environment Protection Committee). In test results, pH geometric mean was 7.68, $BOD_5$(Biochemical Oxygen Demand) geometric mean was 7.28 mg/l, $COD_{cr}$(Chemical Oxygen Demand) geometric mean was 48.39 mg/l, TSS(Total Suspended Solid) geometric mean was 18.00/l, Residual chlorine geometric mean was 0.19 mg/l, and E. coli geometric mean was 1CFU/100 ml. In addition, about 97.4% of $BOD_5$ was reduced, the $COD_{cr}$ reduction averaged 96.4%and the TSS reduction averaged 97.6%. STP have been determined by the MLTM and MEPC regulation of the marine pollution prevention equipment for performance testing product.

Evaluation of Filter-Adsorber(F/A) Process for Removal of Disinfection By-products(DBPs) (소독부산물 제어를 위한 실공정 F/A 운영에 관한 고찰)

  • Kim, Seong-Su;Lee, Kyung-Hyuk;Lim, Jae-Lim;Chae, Seon-Ha;Kang, Byeong-Soo;Moon, Pil-Joong;Ahn, Hyo-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1035-1042
    • /
    • 2005
  • Granular Activated Carbon(GAC) is widely used in drinking water treatment. At S and B Water Treatment Plant, GAC is used in place of granular media in conventional rapid filters(GAC Filter-Adsorber) for removal of Disinfection By-products(DBPs). The primary focus of this study is on the performance of existing filter-adsorber, and their operation. It was found that F/A process removed turbidity as effective as sand system. The ratio of Hydrophobic DOM (HPO) and hydrophilic DOM (HPI) fraction in the raw water at S and B WTP was similar. Filter Adsorber presented earlier DOC breakthrough and steady state condition which was contributed by biodegradation during operation period. The removal efficiency of DBPs were used to evaluate the filter performance. The DBPs concentration of F/A treated water was below treatment goal level (THM < $80\;{\mu}g/L$, HAA < $60{\mu}g/L$). The removal efficiency of THM decreased rapidly during operation period. However, HAA were removed steadily regardless of the influent concentration of HAA. These results indicate that the removal of THM depend upon the adsorption mechanism while the removal of HAA depend upon biodegradation as well as adsorption. The decrease of adsorption capacity and characteristic value of GAC may be attributed to the effect of high organic loading, residual free chlorine, coagulants, manganese oxidants and frequently backwashing. This study has confirmed that Filter adsorber process can be considered as effective alternatives for the removal of DBPs, especially HAA.

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.