• Title/Summary/Keyword: residential concentration

Search Result 355, Processing Time 0.025 seconds

Distribution of Polycyclic Aromatic Hydrocarbons in PM$_{10}$ and its Adjacent Soil of Urban Atmosphere (도시대기의 미세먼지(PM$_{10}$) 및 주변토양중 다환방향족 탄화수소의 농도분포에 관한 연구)

  • 박기학;최성훈
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 1998
  • This study was carried out to investigate the distribution of PAHs in atmosphere and soil, and their relationship, accumulation tendency in soil, and its contain burden ratio (%) the PM$_{10}$ and soil were sampled adjacent to a roadside and analysed by HPLC from August 25th 1996 to September 22nd 1996 in Seoul and Kunggido area. The main results are summarized below 1. The concentration of PM$_{10}$ in the ambient air was showed in order of industrial region ($142.70\pm 21.77 \mu g/m^3$), commercial region ($136.51\pm 31.62 \mu g/m^3$), residential region ($110.12\pm 14.98 \mu g/m^3$), greenbelt region ($77.44\pm 12.12 \mu g/m^3$), respectively. 2. Distribution of PAHs concentration level in PM$_{10}$ and soil was showed in order of industrial region, commercial region, residential region, greenbelt region, respectively in all components. 3. The contain burden ratio (%) in PM$_{10}$ was attested that BbF was the highest contain burden component (21.7-32%) and An was the lowest contain burden component (0.35-1.95%) in all region. 4. The contain burden ratio (%) in soil was attested that Pb (20.5%) was the highest and An (0.8%) was the lowest contain burden component in industrial region and BbF (21.9%) and An (0.45%) were the same tendency in commercial region and Py (21.6%) and BkF (3.5%) were in residential region, Py (29%) and An (2.6%) were in greenbelt region. 5. The relationship between concentration of PAHs in PM$_{10}$ and soil was attested that the component of BbF (r=0.514) was very highly correlated, and there were significant in Fl and BaA in soil between industrial region and commercial region (P<0.05).

  • PDF

A Study on the Characteristics of $PM_{10}$ and Air-borne Metallic Elements Produced in the Industrial City (산업도시 대기 중$PM_{10}$의 농도 및 금속원소 성분의 특성 연구)

  • 나덕재;이병규
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.23-35
    • /
    • 2000
  • PM10, which is below 10 ${\mu}{\textrm}{m}$ in a diameter, has a high deposition in the lung or the bronchus by breathing and is generally composed of a lot of organic matters, viruses, algae, mold, and metallic elements that are very toxic to people. This study identified the characteristics of concentration of PM10 and air-borne jmetallic elements produced in the industrial city, Ulsan, and analyzed the correlatuion between sources and generation patterns of PM10 and metallic elements. We classified the five areas(green, residential, heavy traffic, mechanic, and petrochemcal and non-ferrous metal) which might have different characteristics of sources of PM10 and metallic elements. The average concentrations of PM10 in the five areas were as follows(petrochemical and non-ferrous metal(99.9$\mu\textrm{g}$/㎥)>mechanic(77.5 $\mu\textrm{g}$/㎥)>heavy traffic(47.1 $\mu\textrm{g}$/㎥)>residential(39.3 $\mu\textrm{g}$/㎥)>green(32.8 $\mu\textrm{g}$/㎥)). Those of petrochemical and non-ferrous metal areas were higher than other areas. In this study, the average concentration trend of metallic elements contained in PM10 are shown as follows: Fe>Zn>Pb>Cu>Mn>Cr>As>Cd>Sn>Hg, respectively. The metallic elements identified in PM10 showed the highest concentration in the petrochemical and non-ferrous areas. Metal combinations showed that a high correlation among concentrations of heavy metals were as follows: As, Cd and Fe in the residential area; Zn, Mn, Cu and Pb in the mechanical area; and Zn, Cu, As, Pb in the petrochemical and non-ferrous industrial area.

  • PDF

Health risk assessment by CRPS and the numerical model for toluene in residential buildings

  • Choi, Haneul;Kim, Hyungkeun;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.17 no.5
    • /
    • pp.33-41
    • /
    • 2017
  • Purpose: Indoor air quality in residential buildings needs to be evaluated over the long term. In previous research, there has been an attempt to perform the health risk assessment of pollutants by using numerical models as a method of long-term evaluation. However, the numerical model of this precedent study has limitations that do not reflect the actual concentration distribution. Therefore, this study introduces the CRPS index, constructs a numerical model that can reflect the concentration distribution, and then presents a more accurate health risk assessment method using it. At this time, the pollutants are toluene, which is a typical material released from building materials. Method: CRPS index was applied to existing numerical model to reflect concentration distribution. This was used to calculate concentrations at adult breathing area and to use them for exposure assessment in a health risk assessment. After that, we entered adult data and conducted a health risk assessment of toluene. Results: The non-carcinogenic risk of toluene was calculated to be 0.0060. This is 5% smaller than the existing numerical model, meaning that it is more accurate to predict the pollutant risks. This value is also lower than the US EPA reference value of 1. Therefore, under the conditions of this study, long-term exposure of adults to toluene has no impact on health.

Preliminary Measurements of Mercury Exchange Rates Across the Soil-Air Boundary in a Residential Area of Seoul (토양-대기의 수은 교환작용 -서울시 주거지역에 대한 예비측정-)

  • 김기현;김민영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.369-377
    • /
    • 1998
  • To examine various aspects of Hg exchange processes, we measured Hg$^{\circ}$concentration gradients over soil surfaces in a residential area of Seoul during Sept. 1997. From these measurements, we found that Hg$^{\circ}$concentrations in lower(20 cm) and upper(200 cm) levels varied in the range of 3.15~14.38 (5.30$\pm$1.88: N=236) and 2.07~15.10ng/m$^3$(4.06$\pm$1.69: N=236), respectively. When our data were divided into emission and dry deposition, emission of Hg$^{\circ}$was overwhelmingly dominant (up to 98% in frequency) over dry deposition. The concentration gradients for emission and deposition events were 1.29$\pm$0.86(N=231) and -1.0$\pm$1.27ng/m$^3$(N=5), respectively. The observation of excessively high concentrations in both levels and development of strong gradients suggest that our study site be greatly affected by certain pollution sources of mercury. In face, those data were quite comparable to that had previously been observed from highly contaminated soil environs of Tennessee, USA. To provide some insights into the processes governing the Hg$^{\circ}$exchange processes, we have conducted correlation analyses between Hg$^{\circ}$data and other concurrently determined meteorological plus chemical data. In general, Hg$^{\circ}$concentrations of both levels exhibited similarly the existence of strong correlations with parameters like windspeed, temperature, and relative humidity. Although its concentration gradient data showed similarly strong correlations with meteorological parameters, they showed somewhat unique patterns in that their correlations with Hg$^{\circ}$concentration were noticeably stronger for the lower level than the upper level. To provide rough estimates of Hg$^{\circ}$fluxes in this study, we computed its flux using our gradient data and the predicted K values from previous studies. According to this approach, Hg$^{\circ}$emissions were generally in the range of 103$\pm$80(N=231), while its depositions, being scarcely found, were on the similar magnitude of -92$\pm$128ng/m$^2$/hr(N=5). The findings of excessive emission of Hg$^{\circ}$in residential area of Korea suggests that contamination of mercury be a significant process and hence be dealt more seriously.

  • PDF

The Study on the Relationship between Land Use and Groundwater Quality in the Rapidly Urbanized Area (도시화가 빠르게 진행된 지역의 토지이용과 지하수 수질과의 관계에 대한 연구)

  • An, Jung-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.1
    • /
    • pp.97-108
    • /
    • 2002
  • The use of land at the time of investigation of groundwater quality in the rapidly urbanized Bu-chon city is classified into 5 categories based on the change process of land use. The difference in groundwater quality according to the land use and its usage period is tested by non-parametric statistical procedures. The seven constituents of water quality with the highly frequent detection in the area for this study are used for the statistical test. The shallow groundwater quality within the areas of the same land use at the time of investigation varies significantly according to the period of land usage. The concentration of KMnO$_4$consumed and hardness is significantly higher in the old residential area (of more than 20 years old) than in the younger one (of less than 10 years old). The quality of the shallow groundwater is also significantly different among the three categories with the similar period of land usage (of more than 15 years old). The concentration of No$_3$-N, hardness and total solid is significantly higher in the residential area than in the agricultural one (namely, the area used as paddy fields 2 to 5 years ago). The median concentration of these constituents is 2.2 to 3.8 times higher in the residential area than in the agricultural one. The concentration of NO$_3$-N, KMnO$_4$, consumed and Cl is significantly higher in the industrial area than in the agricultural one. The median concentration of these constituents is 5.5 to 18 times higher in the industrial area than in the agricultural one. The concentration of KMnO$_4$consumed is significantly higher in the industrial area than in the residential area. The median concentration of these constituents is 12 times higher in the industrial area than in the residential one. The spatial distribution of shallow groundwater quality in the rapidly urbanized area is closely related to the period of land usage as well as the land use, which is presumed to be attributed to the difference in the concentration and leakage rate of the contaminants leaking from damaged sewer into shallow groundwater.

Occupational Transformation and Change of Metropolitan Residential Structure in Post-Industrial Society (후기산업사회의 고용전환과 도시구조)

  • 이기석
    • Journal of the Korean Regional Science Association
    • /
    • v.6 no.2
    • /
    • pp.107-121
    • /
    • 1990
  • The structural change of occupational composition with the coming of post-industrial society is most evidently observed in the developed country. Specially representative of social changes is the emergence of new occupational sectors, such as the so-called quaternary and quinary sectors, which are based on the use of information technology and managerial skills. The paper raises the question of how and in what this chage of occupational components in a mtro area affects the existing residential structure over the period. In order to extend the discussion of the question, the related hypothetical statements on urban spatial impact due to transformation of the society have xtnsively considered and identified a possible multicenter structure concentration and deconcentration of new jobs and population over the metro area. For further examination, the renowned high tech city of Minneaplis -St. Paul has been selected and the occupational labour forces data for 1960 and 1980 analyzed. As a whole, this area has experienced a dispersal and reconcentration of population in new patterns which have resulted from changes in the occupational structure. In particular, the residential area of white-coller workers(the quaternary / quinary or information workers) has expanded into the city from a suburban core area. In this process, a large proportion of the manual-worker's residential areas in the central city either disappeared or diminished. Consequently, other isolated centers created by the manualworker residents are emerging in both the central city and suburbs. Thus, the development of mulitple centers or cores based on the distribution of occupational characteristics can be considered as a typical ongoing pattern of metro areas in the Unite States.

  • PDF

Satellite-based Assessment of Ecosystem Services Considering Social Demand for Reduction of Fine Particulate Matter in Seoul

  • Lim, Chul-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.4
    • /
    • pp.421-434
    • /
    • 2022
  • Fine particulate matter (PM2.5) has been the biggest environmental problem in Korea since the 2010s. The present study considers the value of urban forests and green infrastructure as an ecosystem service (ES) concept for PM2.5 reduction based on satellite and spatial data, with a focus on Seoul, Korea A method for the spatial ES assessment that considers social demand variables such as population and land price is suggested. First, an ES assessment based on natural environment information confirms that, while the vitality of vegetation is relatively low, the ES is high in the city center and residential areas, where the concentration of PM2.5 is high. Then, the ES assessment considering social demand (i.e., the ESS) confirms the existence of higher PM2.5 values in residential areas with high population density, and in main downtown areas. This is because the ESS of urban green infrastructure is high in areas with high land prices, high population density, and above-average PM2.5 concentrations. Further, when a future green infrastructure improvement scenario that considers the urban forest management plan is applied, the area of very high ESS is increased by 74% when the vegetation greenness of the green infrastructure in the residential area is increased by only 20%. This result suggests that green infrastructure and urban forests in the residential area should be continuously expanded and managed in order to maximize the PM2.5 reduction ES.

Socio-economic Polarization and Intra-urban Residential Segregation by Class (사회경제적 양극화와 도시 내 계층별 거주지 분리)

  • Chung, Su-Yeul
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.1-16
    • /
    • 2015
  • It is widely believed that increasing socio-economic polarization inspired by globalization and economic restructuring worsens residential segregation by class in Korean cities. However, the existing literature falls short in showing the recent changes of the residential segregation, particularly after the 1997 financial crisis, with reliable and systematic segregation measures. Noting that there are the two major dimension in residential segregation - evenness-concentration and exposure-clustering - this study introduced not only global measure (dissimilarity index and isolation/interaction index) but also local measures (location quotient and Local Moran's I) for each dimension. These measures are applied to the case study of Seoul in the 2000s. The class is defined by education attainment and the data is obtain through the MicroData System Service System(MDSS). The result shows that the residential segregation by education attainment persists through 2000s and even get worse in some dimension. More significantly, it turns out that high-class and low-class residence are nearly mirror-images of each other, indicating high segregation.

  • PDF

A Study on Public Nuisance in Seoul, Pusan and Daegu Cities Part I. Survey on Air Pollution and Noise Level (공해(公害)에 관(關)한 조사연구(調査硏究) 제일편(第一編) : 서울, 부산(釜山), 대구(大邱) 지역(地域)의 대기오염(大氣汚染) 및 소음(騷音)에 관(關)한 비교조사(比較調査) 연구(硏究))

  • Cha, Chul-Hwan;Shin, Young-Soo;Lee, Young-Il;Cho, Kwang-Soo;Choo, Chong-Yoo;Kim, Kyo-Sung;Choi, Dug-Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.41-64
    • /
    • 1971
  • During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas; the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by $PbO_2$ cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide ($SO_2$) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was $30.42ton/km^2/month$, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were $33.17ton/km^2/month$ in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were $52.32ton/km^2/month$ in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were $48.27ton/km^2/month$ in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were $36.46ton/km^2/month$ in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were $1.52mg\;SO_3/day/100cm^2\;PbO_2$, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were $1.89mg\;SO_3/day/100cm^2\;PbO_2$ in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were $2.16mg\;SO_3/day/100cm^2\;PbO_2$ in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a peak in November. 11. The mean values of suspended particles was $2.89mg/m^3$, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by city were $3.14mg/m^3$ in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan, and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residential area. 16. The comparison of the noise levels by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration of sulfur dioxides ($SO_2$) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentrations of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. The weekly average concentration of carbon monoxides(CO) was 27.59 ppm. 20. The daily average concentrations of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of $SO_2$ and CO reaches a peak from 6 p. m. to 8 p. m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industial area. 23. As for daily variation of the concentration of $SO_2$ and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.

  • PDF

The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House (에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성)

  • Yoo, Bok-Hee;Park, Sun-Hyo
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.