• Title/Summary/Keyword: repeating measurement

Search Result 39, Processing Time 0.03 seconds

Investigation on the Seventh Grade Student's Preconceptions about Measurement Theory (측정이론에 관한 중학교 1학년 학생의 선개념 조사)

  • Suh, Jung-Ah
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.3
    • /
    • pp.455-465
    • /
    • 2002
  • This study investigates students' preconceptions about measurement theory; repeating measurements. how to handle repeat measurements, measurement errors, and uncertainty. Thirty students in seventh grade participated in this study. Students' conceptions were elicited using observation and interview notes. Half of the students measured only two times. and none of them more than five times. After repeating measurements, seventy seven percent of them selected result according to their feelings, while only thirteen percent of them calculated the mean. Sixty percent of them regarded the main cause of measurement errors as their mistakes, not as the problems of environment or measuring instrument. Most students thought the main reason of various results by different persons or time period as human. Forty percent of them denied the uncertainty of measurement, while thirty three agreed, and most students thought the reason of uncertainty was due to human imperfection. This study showed more than half of the students did not know how to handle repeat measurements, and they regarded the cause of measurement errors as their mistakes. In addition, they thought the main reason of various measuring results and uncertainty as human.

New Calibration Methods for improving the Accuracy of AFM (원자간력 현미경의 자율교정법)

  • Kweon, Hyun-Kyu;Go, Young-Chae
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.48-52
    • /
    • 2001
  • In this paper presents an accurate AFM used that is free from the Z-directional distortion of a servo actuator is described. Two mathematical correction methods by the in-situ self-calibrationare employed in this AFM. One is the method by the integration, and the other is the method by inverse function of the calibration curve. The in situ self-calibration method by the integration, the derivative of the calibration curve function of the PZT actuator is calculated from the profile measurement data sets which are obtained by repeating measurements after a small Z-directional shift. Input displacement at each sampling point is approximately estimated first by using a straight calibration line. The derivative is integrated with reference to the approximate input to obtain the approximate calibration curve. Then the approximation of the input value of each sampling point is improved using the obtained calibration curve. Next the integral of the derivative is improved using the newly estimated input values. As a result of repeating these improving process, the calibration curve converges to the correct one, and the distortion of the AFM image can be corrected. In the in situ self-calibration through evaluating the inverse function of the calibration curve, the profile measurement data sets were used during the data processing technique. Principles and experimental results of the two methods are presented.

  • PDF

Elementary Students' Epistemological Views on the Nature of Scientific Measurement (측정의 본성에 대한 초등학생들의 인식론적 견해)

  • Yang, Chan-Ho;Lee, Ji-Hyeon;Kim, Young-Hoon;Noh, Tae-Hee
    • Journal of Korean Elementary Science Education
    • /
    • v.30 no.4
    • /
    • pp.430-441
    • /
    • 2011
  • We investigated the elementary students' epistemological views on the nature of scientific measurement. The Views About Scientific Measurement (Ibrahim, 2005) was administered to 117 sixth graders. The analyses of the results indicated that there was an inconsistency in their epistemological views depending on the contexts of the measurement. They also had some difficulties in understanding a distribution of the data, which is needed to understand the necessity of repeating measurements, choosing a best representative value, and comparing data sets. They were found to have some naive views on scientific measurement which influenced negatively for fostering modern epistemological views on the nature of scientific measurement. The results suggest that the nature of scientific measurement should be emphasized explicitly in the national curriculum, and an effective method which improves elementary students' epistemological views on the nature of scientific measurement also be developed.

Automatic Switching System for The Impedance Analysis of Multichannel icroelectrode Arrays: Limits and Improvement Scheme (다채널 미세전극칩 임피던스 분석을 위한 자동 스위칭 시스템: 한계점 및 개선 방안)

  • Lee, Seok-Young;Nam, Yoon-Key
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2011
  • Electrode impedances are measured to quantitatively characterize the electrode-electrolyte or cell-electrode interfaces. In the case of high-density microelectrode arrays(MEAs) that have been developed for brainmachine interface applications, the characterization process becomes a repeating and time-consuming task; a system that can perform the measurement and analysis in an automated fashion with accuracy and speed is required. However, due to the large number of channels, parasitic capacitance and off-capacitance components of the switching system become the major factors that decreased the accuracy for the measurement of high impedance microelectrodes. Here we investigated the implementation of automatic impedance measurement system with analyzing the causes of possible measurement-related problems in multichannel switching configuration. Based on our multi-channel measurement circuit model, we suggest solutions to the problems and introduce a novel impedance measurement scheme using electro-mechanical relays. The implemented measurement system could measure |Z| < 700 $k{\Omega}$ of impedance in - 10% errors, which can be widely applicable to high density neural recording MEAs.

Basic Study of the Improvement of PSD Output by Inclined Light Input (PSD의 출력특성향상을 위한 경사 입력광의 특성해석에 대한 기본연구)

  • Kweon, Hyun-Kyu;Park, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.53-58
    • /
    • 2010
  • In this paper, the output characteristics of PSD(Position Sensetive Detector) used in measurement system are described. Most of the precision measurment systems are accomplished by a laser diode(LD), a photo diode(PD) and PSD(Position Sensetive Detector), which are used in reflection of mirror or projection of infrared spectrometer. But it is especially restricted by resolution of PD and PSD in nano-measurement. A new inclined light methods into the PSD are employed in the surface measurement system for increasing the resolution. As the results, we can know that the output characteristics of detective senser (PSD) become more than 2 or 3 times by changing inclined angle(range: 5 degree) compared with common angle. In addition, the experiment results are confirmed that the change of inclined angle is not affecting to the linearity and repeating.

Uncertainty assessment for a towed underwater stereo PIV system by uniform flow measurement

  • Han, Bum Woo;Seo, Jeonghwa;Lee, Seung Jae;Seol, Dong Myung;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.5
    • /
    • pp.596-608
    • /
    • 2018
  • The present study aims to assess test uncertainty assessment method of nominal wake field measurement by a Stereoscopic Particle Image Velocimetry (SPIV) system in a towing tank. The systematic uncertainty of the SPIV system was estimated from repeated uniform flow measurements. In the uniform flow measurement case, time interval between image frames and uniform flow speed were varied to examine the effects of particle displacement and flow around the SPIV system on the systematic standard uncertainty. The random standard uncertainty was assessed by repeating nominal wake field measurements and the estimated random standard uncertainty was compared with that of laser Doppler velocimetry. The test uncertainty assessment method was applied to nominal wake measurement tests of a very large crude oil carrier model ship. The nominal wake measurement results were compared with existing experimental database by other measurement methods, with its assessed uncertainty.

Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module (PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Chi-Hong;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test (PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석)

  • Kang, Gi-Hwan;Park, Chi-Hong;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

The Effect of Arm Movements in the during Standing Position on Lower Limb Global Synkinesis and Balance in Stroke Patients

  • Moon, YoungJun;Jeong, DaeKeun;Kang, Jeongil
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1849-1855
    • /
    • 2019
  • Background: Stroke patients require arm movement exercising for various stimulations in standing position for various stimulations rather than in a sitting position because they require integrated skillful movements, such as stretching, holding, and controlling. Objective: This study was conducted to provide foundational clinical data about lower limb global synkinesis in stroke patients using arm movements in a standing position. Design: Randomized controlled trial. Methods: The subjects were divided into a control group (n = 10) and an experimental group (n = 10), and a pre-test was conducted to evaluate leg global synkinesis (GS) and balance. Intervention method is stretching an arm to hold a ball, repeating supination and pronation of the hand only while maintaining the arm extended as much as possible, repeating shoulder abduction and adduction while holding the pegboard. This was followed by a three-week intervention during which re-measurement was conducted in the same way as was done for the pre-test. Results: The control group showed a significant difference in GS and balance during plantar flexion (p<.05), and the experimental group showed a significant difference in GS and balance during all movements (p<.05, p<.01, respectively). There was a significant difference in GS and balance between the two groups during dorsiflexion (p<.05, p<.01, respectively). Conclusion: The findings demonstrate that human arm movements in a standing position can reduce GS in the affected limb, and balance can be improved by stimulating the surrounding tissues of the affected limb and changing them positively.

Tilt Measurement of Drilling Machine Using the Laser Interferometer (레이저 간섭계를 이용한 드릴링 머신의 틸트 측정)

  • 이승수;손영지;김순경;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.479-484
    • /
    • 1996
  • This paper describes a method of measuring tilt motion. This method measures the tilt motion of drilling machines using a laser interferometer, a simple sliding linear bearing, measurement of the probe and the LSC(least square center) method. The next order of business is discussing the procedure of measurement. First, The measured position is considered to be the point of contact between the drill shank and the probe. The revolution of the drill axis delivers the point of contact to the probe. Second, because the laser interferometer is attached on the sliding linear bearing, any movement of probe influences laser reflector. Thus, the laser program displays the moving factor of laser reflector. Namely, this is tilt factor. Third. the points of measurement are a full circle which has 8 points (each are 45$^{\circ}$), After it is finished measuring the 8 points, let the spindle of the drilling machine move down about 5 cm. Repeating this procedure three times, we can get tilt motion's values which are calculated by LSC method. Many error factors affect the accurate measurement of tilt motion. However in this paper we ignore some error factors because they are less significant than tilt motion.

  • PDF