• Title/Summary/Keyword: repeat time

Search Result 349, Processing Time 0.026 seconds

STUDY OF RAT EPIGASTRIC VESSELS ACCORDING TO THE FREEZING TIME : HISTOLOGIC, HISTOMORPHOMETRIC, IMMUNOHISTOCHEMICAL & SCANNING ELECTRON MICROSCOPIC STUDY (백서 상복부 혈관의 동결시간에 따른 변화에 대한 연구)

  • Kim, Woo-Chan;Lee, Chong-Heon;Kim, Kyung-Wook;Kim, Chang-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.89-109
    • /
    • 1999
  • Vascular spasm which has been reported to occur in 25% of clinical cases continues to be a problem in microvascular surgery; When prolonged and not corrected, it can lead to low flow, thrombosis, and replant or free flap failure. Ischemia, intimal damage, acidosis and hypovolemia have been implicated as contributors to the vascular spasm. Although much work has been done on the etiology and prevention of vasospasm, a spasmolytic agent capable of firmly protecting against or reversing vasospasm has not been found. Therefore vascular freezing was introduced as a new safe method that immediately and permanently relieves the vasospasm and can be applied to microsurgical transfers. Cryosurgery can be defined as the deliberate destruction of diseased tissue or relief the vascular spasm in microvascular surgery by freezing in a controlled manner. 96 Sprague Dawley rats each weighing within 250g were used and divided into 2 group, experimental 1 and 2 group. In the experimental 1 group, right epigastric vessels (artery and vein) were freezed with a cryoprobe using $N_2O$ gas for 1 min. In the experimental 2 group, after freezing for 1 min, thawing for 30 secs and repeat freezing for 30 secs. Left side was chosen as control group in both group. We sacrified the experimental animals by 1 day, 3 days, 1 week, 2 weeks, 4 weeks & 5 months and observed the sequential change that occur during regeneration of epigastric vessels using a histologic, histomorphometric, immunohistochemical and SEM study after the vascular freezing. The results were as follows1. In epigastric arteries, internal diameters had statistically significant enlargement in 1 day, 3 days of Exp-1 group and 1 day, 3 days, 1 week & 2 weeks of Exp-2 group. Wall thickness had statistically significant thinning in 2 weeks of Exp-2 group. 2. In epigastric veins, internal diameters had enlargement of statistical significance in 1 day of Exp-1 and Exp-2 group. 3. The positive PCNA reactions in smooth muscle appeared in 1 week and increased until 2 weeks, decreased in 4 weeks. There was no statistical significance between Exp-1 and Exp-2 group. 4. The positive ${\alpha}$-SMA reaction in smooth muscles showed weak responses until 1 week and slowly increased in 2 weeks and showed almost control level in 4 weeks. 5. The positive S-100 reactions in the perivascular nerve bundles showed markedly decrease in 1 day, 3 days and increased after 1 week and showed almost control level in 4 weeks. Exp-1 group had stronger response than Exp-2 group. 6. In SEM, we observed defoliation of endothelial cell and flattening of vessel wall. Exp-2 group is more destroyed and healing was slower than Exp-1 group. To sum up, relief of vasospasm (vasodilatation) by freezing with cryoprobe was originated from the damage of smooth muscle layer and perivascular nerve bundle and the enlargement of internal diameter in vessels was similar to expeimental groups, but Exp-2 group had slower healing course and therefore vessel freezing in microsurgery can be clinically used, but repeat freezing time needs to be studied further.

  • PDF

Thermoregulatory Responses of AM & PM with Body Fat Rate at a Hot Environment (서열환경하에서 체지방률에 따른 오전과 오후의 체온조절반응)

  • Kim, Seong-Suk;Lee, Jung-Sug;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.7 no.3
    • /
    • pp.315-320
    • /
    • 2005
  • With regard to the fact that temperature of human body remains almost constant at $37^{\circ}C$, changes by circadian variation, this study intended to investigate the effect of circadian rhythm on physiological responses of human body according to body fat rate. Fifteen healthy adult women were recruited for this study and were measured body fat as a method of bio impedance. We organized subjects into three groups ; low body fat group(group L-less than 20% of body fat), medium body fat group(group M-20%~30% of body fat) and high body fat group(group H-more than 30% of body fat). The experiment was carried out in a climate chamber of $32^{\circ}C$, 60% RH with the repeat of 'Exercise' and 'Rest' period. Subjects participated in two experiments, one is morning experiment(called 'AM'), the other is afternoon experiment (called 'PM'). The results of this study are as follows ; As to the variation of rectal temperature, group L and M had a significant difference in the time of the day between AM and PM, but group H had almost the same rectal temperature in the two kinds of experimental time. The reason why group H had a smaller difference in the circadian rhythm of rectal temperature in this study is estimated at the Budd et al.(1991)'s results that body fat had effects on reduction in thermogenesis, radiation, mean skin temperature, and increase in insulation of the tissues. Group M had the highest mean skin temperature in the 'PM'. All the 3 groups didn't have stable values in 'AM'. But it showed more stable in 'PM' than 'AM'. Sweat rate was the highest in group H in both 'AM' and 'PM'. Group M had larger sweat rate in 'PM' than 'AM'. but in group L and H, sweat rate was almost the same in two kinds of time of the day. This result suggests that who have more or less body fat have larger difference in sweat rate between morning and afternoon than who have normal body fat.

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.

Analysis of Microclimate and Conservation Environment of the Stone Buddha and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 보존환경 및 미기상 분석)

  • Park, Sung-Mi;Lee, Chan-Hee;Lee, Myeong-Seong;Kim, Sa-Dug
    • Economic and Environmental Geology
    • /
    • v.42 no.1
    • /
    • pp.73-84
    • /
    • 2009
  • The stone Buddha and Shrine of Unjusa temple (Korean Treasure No. 797) at Hwasun formed in Koryo Dynasty is unique style which faces each other the back parts of south and north within the stone Shrine. The stone Buddha and Shrine is highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. To inquire into relative deterioration and environmental factor, air temperature and relative humidity of the stone Buddha and Shrine were monitored for a year of the indoor and outdoor, respectively. As a result, the temperature shows increase and decrease according to the seasons in the tendency to clear. While the relative humidity is high to keep all four seasons. Highly relative humidity environment induces dew condensation on the interior of stone Buddha and Shrine. The dew condensation is recorded at the spring, summer and winter season. The summer season is double the total of spring and winter season. In the case of summer, dew condensation is long time continued due to high temperature and relative humidity that is kept by more than nearly 100%. There is progress towards chemical weathering throughout dissolve rock properties and alteration on the rock surface. In the case of winter, dew condensation is not kept for a long time as summer. In the winter, which showing a below zero may add physical weathering throughout moisture that happen by dew condensation to repeat freezing and thawing. Therefore, the reduction plan of the relative humidity effect on dew condensation should be prepared.

SF Movie Star Trek Series and the Motif of Time Travel (SF영화 <스타트랙> 시리즈와 시간여행의 모티프)

  • Noh, Shi-Hun
    • Journal of Popular Narrative
    • /
    • v.25 no.1
    • /
    • pp.165-191
    • /
    • 2019
  • The purpose of this article is to elucidate why the motif of time travel is repeated in the science fiction narrative by examining the functions of this motif in the SF movie series of Star Trek in its narrative and non-narrative aspects. Star Trek IV: The Voyage Home (1986) aims to attract the audience's interest in the story through the use of plausible time travel in the form of the slingshot effect which causes the spacecraft to fly at very fast speeds around an astronomical object. The movie also touches upon the predestination paradox that arises from a change of history in which it describes a formula of transparent aluminum that did not exist at the time. The film also serves as an evocation of the ideology of ecology by including humpback whales in the central narrative and responding to the real issue of the whale protection movement of the times. Star Track VIII: First Contact (1996) intends to interest the audience in the narrative with the warp drive, a virtual device that enables travel at speeds faster than that of light and a signature visual of Star Trek, at the time of its birth through time travel. The film emphasizes the continuation of peaceful efforts by warning the destruction of humanity that nuclear war can bring. It tackles with the view of pacifism and idealism by stressing the importance of cooperation between countries in the real world by making the audience anticipate the creation of the United Federation of Planets through encounters with the extraterrestrial. Star Trek: The Beginning (2009) improves interest through the idea of time travel to the past, this time using a black hole and the parallel universe created thereby. The parallel universe functions as a reboot, allowing a new story to be created on an alternate timeline while maintaining the original storyline. In addition, this film repeats the themes pacifism and idealism shown in the 1996 film through the confrontation between Spock (and the Starfleet) and Nero, the destruction of the Vulcan and the Romulus, and the cooperation of humans and Vulcans. Eventually, time travel in three Star Trek films has the function of maximizing the audience's interest in the story and allowing it to develop freely as a narrative tool. It also functions as an ideal solution for commenting on current problems in the non-narrative aspect. The significance of this paper is to stress the possibility that the motif of time travel in SF narrative will evolve as it continues to repeat in different forms as mentioned above.

Analysis of Rainfall Runoff Delay Effect of Vegetation Unit-type LID System through Rainfall Simulator-based Probable Rainfall Recreation (인공강우기 기반 확률강우재현을 통한 식생유니트형 LID시스템의 우수유출지연 효과분석)

  • Kim, Tae-Han;Park, Jeong-Hyun;Choi, Boo-Hun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.6
    • /
    • pp.115-124
    • /
    • 2019
  • In a climate change environment where heat damage and drought occur during a rainy season such as in 2018, a vegetation-based LID system that enables disaster prevention as well as environment improvement is suggested in lieu of an installation-type LID system that is limited to the prevention of floods. However, the quantification of its performance as against construction cost is limited. This study aims to present an experiment environment and evaluation method on quantitative performance, which is required in order to disseminate the vegetation-based LID system. To this end, a 3rd quartile huff time distribution mass curve was generated for 20-year frequency, 60-minute probable rainfall of 68mm/hr in Cheonan, and effluent was analyzed by recreating artificial rainfall. In order to assess the reliability of the rainfall event simulator, 10 repeat tests were conducted at one-minute intervals for 20 minutes with minimum rainfall intensity of 22.29mm/hr and the maximum rainfall intensity of 140.69mm/hr from the calculated probable rainfall. Effective rainfall as against influent flow was 21.83mm/hr (sd=0.17~1.36, n=20) on average at the minimum rainfall intensity and 142.27mm/hr (sd=1.02~3.25, n=20) on average at the maximum rainfall intensity. In artificial rainfall recreation experiments repeated for three times, the most frequent quartile was found to be the third quartile, which is around 40 minutes after beginning the experiment. The peak flow was observed 70 minutes after beginning the experiment in the experiment zone and after 50 minutes in the control zone. While the control zone recorded the maximum runoff intensity of 2.26mm/min(sd=0.25) 50 minutes after beginning the experiment, the experiment zone recorded the maximum runoff intensity of 0.77mm/min (sd=0.15) 70 minutes after beginning the experiment, which is 20 minutes later than the control zone. Also, the maximum runoff intensity of the experiment zone was 79.6% lower than that of the control zone, which confirmed that vegetation unit-type LID system had rainfall runoff reduction and delay effects. Based on the above findings, the reliability of a lab-level rainfall simulator for monitoring the vegetation-based LID system was reviewed, and maximum runoff intensity reduction and runoff time delay were confirmed. As a result, the study presented a performance evaluation method that can be applied to the pre-design of the vegetation-based LID system for rainfall events on a location before construction.

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Anti-proliferative Effects of Atractylis lancea (Thunb.) DC. via Down-regulation of the c-myc/hTERT/Telomerase Pathway in Hep-G2 Cells

  • Guo, Wei-Qiang;Li, Liang-Zhi;He, Zhuo-Yang;Zhang, Qi;Liu, Jia;Hu, Cui-Ying;Qin, Fen-Ju;Wang, Tao-Yun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6363-6367
    • /
    • 2013
  • Atractylis lancea (Thunb.) DC. (AL), an important medicinal herb in Asia, has been shown to have anti-tumor effects on cancer cells, but the involved mechanisms are poorly understood. This study focused on potential effects and molecular mechanisms of AL on the proliferation of the Hep-G2 liver cancer cell line in vitro. Cell viability was assessed by MTT test in Hep-G2 cells incubated with an ethanol extract of AL. Then, the effects of AL on apoptosis and cell cycle progression were determined by flow cytometry. Telomeric repeat amplification protocol (TRAP) assays was performed to investigate telomerase activity. The mRNA and protein expression of human telomerase reverse transcriptase (hTERT) and c-myc were determined by real-time RT-PCR and Western blotting. Our results show that AL effectively inhibits proliferation in Hep-G2 cells in a concentrationand time-dependent manner. When Hep-G2 cells were treated with AL after 48h,the $IC_{50}$ was about 72.1 ${\mu}g/mL$. Apoptosis was induced by AL via arresting the cells in the G1 phase. Furthermore, AL effectively reduced telomerase activity through inhibition of mRNA and protein expression of hTERT and c-myc. Hence, these data demonstrate that AL exerts anti-proliferative effects in Hep-G2 cells via down-regulation of the c-myc/hTERT/telomerase pathway.

Development of Dispenser System with Electrohydrodynamic and Voice Coil Motor for White Light Emitting Diode (백색 LED 제조를 위한 정전기력과 보이스코일모터를 이용한 디스펜서 시스템 개발)

  • Kang, Dong-Seong;Kim, Ki-Beom;Ha, Seok-Jae;Cho, Myeong-Woo;Lee, Woo-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6925-6931
    • /
    • 2015
  • LED(Light Emitting Diode) is used in various filed like a display because of low power consuming, long life span, high brightness, rapid response time and environmental-friendly characteristic. General fabrication method is combination blue light LED chip with yellow fluorescent substance. Because this way is suitable for industry field in terms of convenience, economic, efficiency. In white light LED packaging process, encapsulation process that is dispensing fluorescent substance with silicon to blue light LED chip is most important. So, in this paper we develop EHD pump system using voice coil motor and electrostatic pump for dispensing fluorescent substance. For these things we conduct basic test about liquid surface profiles by voltage and process time. Through this data we decide optimal process condition and verify the optimal condition using design of experiment method. And to confirm uniformity of the condition, we conduct repeat dispensing test.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF