Some Results on Availability of Repairable Component and Repairable Coherent System

  • Cha, Ji-Hwan
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.1
    • /
    • pp.191-202
    • /
    • 2003
  • Availability is an important measure of performance of a repairable component. In this paper, the explicit expression for the availability of a repairable component, which is subject to the policy II(Age Replacement Policy) of Barlow and Hunter (1960), is obtained and the existence of the steady state availability is shown. The steady state availabilities of the model are also obtained for the cases when the mean of the minimal repair time is increasing at a geometric rate or linearly increasing, In order to show the importance and the utility of the obtained result, we also consider an illustrative example of the repairable coherent system whose components are repairable, and the obtained results are applied to derive the steady state availability of the whole system. In this situation, we can see that the condition of the existence of the steady state availability for each component is essential. Some remarks on the optimal replacement policy that maximizes the steady state availability are also given.

Case Based Diagnosis Modeling of Dark Current Causes and Standardization of Diagnosis Process (사례기반의 암전류 원인 진단 모델링 및 표준화)

  • Jo, Haengdeug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.149-156
    • /
    • 2017
  • Various kinds of accessories(e.g., clock, radio, automatic door locks, alarm devices, etc.) or unit components (e.g., black box, navigation system, alarm, private audio, etc.) require dark current even when the vehicle power is turned off. However, accessories or unit components can be the causes of excessive dark current generation. It results in battery discharge and the vehicle's failure to start. Therefore, immediate detection of abnormal dark current and response are very important for a successful repair job. In this paper, we can increase the maintenance efficiency by presenting a standardized diagnostic process for the measurement of the dark current and the existing problem. As a result of the absence of a system to block the dark current in a vehicle, diagnosis and repair were performed immediately by using a standardized dark current diagnostic process.

The Effects of Alkaloid Fraction of Korean Ginseng on the Radiation-Induced DNA Strand Breaks (방사선 조사에 의한 DNA Double Strand Breaks의 생성 및 회복에 미치는 인삼 알칼로이드 분획의 효과)

  • Cho Chul Koo;Kim Tae Hwan;Yoo Seong Yul;Koh Kyoung Hwan;Kim Mi Sook;Kim Jeong Hee;Kim Seong Ho;Yoon Hyung Keun;Ji Young Hoon
    • Radiation Oncology Journal
    • /
    • v.13 no.2
    • /
    • pp.113-120
    • /
    • 1995
  • Purpose : To investigate the effect of alkaloid fraction from Korean ginseng on radiation-induced DNA double strand breaks (dsb) formation and repair in murine lymphocytes Materials and Methods : We used the neutral filter elution technique to assay $^{60}Co\;{\gamma}$ ray-induced DNA double strand breaks formation and repair in C57BL/6 mouse spleen lymphocytes for evaluating the dose-response relationship in the presence of alkaloid fraction as a radioprotective agent. The lymphocytes were stimulated with Phytohemagglutinin (PHA, 2 u g/ml) to label $^3[H]-thymidine.$ Isotope-labelled lymphocytes in suspension were exposed to 100 Gy at $0^{\cdot}C$ in the alkaloid fraction-treated group and elution procedure was performed at PH 9.6. The extents of formation of radiation-induced DNA double strand breaks and repair were compared respectively via strand scission factor (SSF) and relative strand scission factor (RSSF). Results: Alkaloid fraction reduced the formation of double strand breaks with dose modification factor of 2 15, compared to control group Rejoining of DNA dsb appeared to take place via two components. The first fast component was completed within 20.4 minutes, but the second slow component was not completed until 220.2 minutes after irradiation. About $30\%$ of dsb formed by irradiation was ultimately unrejoined despite the administration of alkaloid fraction. The administration of alkaloid fraction had a great effect on the second slow component of repair; the half-time of fast component repair was not changed, but that of slow component was 621.8 minutes. Conclusion: Neutral filter elution assay Proved to be a very effective method to quantitate the extents of DNA dsb formation and its repair. By using this technique, we were able to evaluate the efficiency of alkaloid fraction from Korean ginseng as a valuable radioprotector. Alkaloid fraction can be used prophylactically to prevent or ameliorate the severe radiation damages in workers and neighbors around the atomic power plants. For more refined study, however, more advanced purification of alkaloid fraction wil be needed in the near future.

  • PDF

Locally Repairable Codes with Two Different Locality Requirements (두 개의 다른 부분접속수 요건을 가진 부분접속 복구 부호)

  • Kim, Geonu;Lee, Jungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.12
    • /
    • pp.1671-1683
    • /
    • 2016
  • Locally repairable codes (LRCs) constitute an important class of codes for distributed storage, where repair efficiency is a key metric of system performance. In LRCs, efficient repair is achieved by small locality-number of nodes participating in the repair process. In this paper, we focus on situations where different locality is required for different nodes. We present a non-trivial extension of the recent results on multiple (or unequal) localities to the $r,{\delta}$-locality case. A new Singleton-type minimum distance upper bound is derived and an optimal code construction is provided. While the result is limited to the case of only two different localities, it should be noted that it can be directly applied to the more general case where the localities are specified not exactly but by upper limits.

The Design of Regenerating Codes with a Varying Number of Helper Nodes (다양한 도움 노드의 수를 가지는 재생 부호의 설계)

  • Lee, Hyuk;Lee, Jungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.12
    • /
    • pp.1684-1691
    • /
    • 2016
  • Erasure codes have recently been applied to distributed storage systems due to their high storage efficiency. Regenerating codes are a kind of erasure codes, which are optimal in terms of minimum repair bandwidth. An (n,k,d)-regenerating code consists of n storage nodes where a failed node can be recovered with the help of the exactly d numbers of surviving nodes. However, if node failures occur frequently or network connection is unstable, the number of helper nodes that a failed node can contact may be smaller than d. In such cases, regenerating codes cannot repair the failed nodes efficiently since the node repair process of the codes does not work when the number of helper nodes is less than d. In this paper, we propose an operating method of regenerating codes where a failed node can be repaired from ${\bar{d}}$ helper nodes where $$k{\leq_-}{\bar{d}}{\leq_-}d$$.

Applying SeqGAN Algorithm to Software Bug Repair (소프트웨어 버그 정정에 SeqGAN 알고리즘을 적용)

  • Yang, Geunseok;Lee, Byungjeong
    • Journal of Internet Computing and Services
    • /
    • v.21 no.5
    • /
    • pp.129-137
    • /
    • 2020
  • Recently, software size and program code complexity have increased due to application to various fields of software. Accordingly, the existence of program bugs inevitably occurs, and the cost of software maintenance is increasing. In open source projects, developers spend a lot of debugging time when solving a bug report assigned. To solve this problem, in this paper, we apply SeqGAN algorithm to software bug repair. In detail, the SeqGAN model is trained based on the source code. Open similar source codes during the learning process are also used. To evaluate the suitability for the generated candidate patch, a fitness function is applied, and if all test cases are passed, software bug correction is considered successful. To evaluate the efficiency of the proposed model, it was compared with the baseline, and the proposed model showed better repair.

DNA recombinase Rad51 is regulated with UV-induced DNA damage and the DNA mismatch repair inhibitor CdCl2 in HC11 cells

  • You, Hyeong-Ju;Kim, Ga-Yeon;Kim, Seung-Yeon;Kang, Man-Jong
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.36 no.3
    • /
    • pp.121-128
    • /
    • 2021
  • Increasing the efficiency of HR (homologous recombination) is important for a successful knock-in. Rad51 is mainly involved in homologous recombination and is associated with strand invasion. The HR-related mismatch repair system maintains HR fidelity by heteroduplex rejection and repair. Therefore, the purpose of this study is to control Rad51, which plays a critical role in HR, through UV-induced DNA damage. It is also to confirm the effect on the expression of MMR related genes (Msh2, Msh3, Msh6, Mlh1, Pms2) and HR-related genes closely related to HR through treatment with the MMR inhibitor CdCl2. The mRNA expression of Rad51 gene was confirmed in both HC11 cells and mouse testes, but the mRNA expression of Dmc1 gene was confirmed only in mouse testes. The protein expression of Rad51 and Dmc1 gene increased in UV-irradiated HC11 cells. After 72 hours of treatment with 1 ㎛ of CdCl2, the mRNA expression level of Msh3, Pms2, and Rad51 decreased, but the mRNA expression level of Msh6 and Mlh1 increased in HC11 cells. There was no significant difference in Msh2 mRNA expression between CdCl2 untreated-group and the 72 hours treated group. In conclusion, HR-related gene (Rad51) was increased by UV-induced DNA damage. Treatment of the MMR inhibitor CdCl2 in HC11 cells decreased the mRNA expression of Rad51.

A Study on Remaining Efficiency of Thermal Straightening after Block Lifting

  • Ha, Yunsok;Yi, Myungsu
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.1 no.3
    • /
    • pp.148-156
    • /
    • 2015
  • Deck plates of ships or offshore structures would make out-of-plane distortion for their thin thickness. These distortions are usually straightened by thermal straightening such as flame heating method. After thermal straightening, the blocks are lifted and moved by cranes to assemble it at dry-dock stage. After this lifting process, out-of-plane deformation again happens frequently. And then, they continuously cause quality and accuracy problems in the final dry-dock process. So, it takes more time for repair and correction working. According to preceding research, the lifting process by cranes would offset the effect on thermal straightening. The target of this study is to develop a methodology analyzing the remaining efficiency of thermal straightening after block lifting. The development was based on the assumption of yield state at straightening region. Therefore the remaining efficiency was obtained by different stiffness slope while lifting & relieving. The efficiency formula was designed using inherent strain, and we made a table of zero-efficiency by cooling speed and class rule's steels. As a result, if the stress orthogonal to straightened line is calculated during lifting analysis by FEA, the efficiency can be obtained linearly to the values in the table. Finally, even optimized carling position can be designed by considering the regional data from series project and welding region on deck.

A Development of Efficient Power Conversion Technology for Reduction of Power Equipment (전원설비 저감을 위한 고효율 전력변환기술 개발)

  • Koo, Myoung-Wan;Lee, Woo-Won;Lim, Kye-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.142-144
    • /
    • 2008
  • The Former High Efficiency Inverter(the power restoration process) system process has advantage which is the energy reduction rather than the Former Inverter(the resistence damping process), However, under repair and remodeling, the power facilities capacity is not easy to increase that the former High Efficiency Inverter needs to increase the Power Facilities Capacity of 20~30% than the Inverter(the resistence damping process) so Therefore we are going to suggest the system which is not going to make an increase the power facilities capacity and is applicable the High Efficiency Inverter.

  • PDF

Analysis on Durability Performance Enhancement and Economical Efficiency through Chloride Protection for Concrete Structures (콘크리트 구조물의 염해도장을 통한 내구성능 향상 및 경제적 효과분석)

  • Chai, Won-Kyu;Kim, Seong-Heon;Son, Young-Hyun;Park, Ju-Won;Lee, Cheung-Bin
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.155-160
    • /
    • 2010
  • In this study, detailed assessment for durability performance were performed on the chloride protected concrete structures to investigate the effectiveness of chloride protection. And economical efficiency for the chloride protected concrete structures were studied by LCC(Life Cycle Cost) analysis. In the comparison result of the first section repair time, it was found that the chloride protected concrete structures was economical better than the non-protected concrete structures in the long term. According to the analysis result of the accumulated chloride concentration by used time and chloride ion concentration by depth, it can be seen that the permeation through time from chloride has increased two times in the chloride protected concrete structures.