• 제목/요약/키워드: reliability test

검색결과 6,754건 처리시간 0.041초

프린트 산업에서 부품 신뢰성 시험법 개선 (Case Study of Parts Reliability Improvement)

  • 김판수;한기웅;이지혜
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 춘계학술대회
    • /
    • pp.663-674
    • /
    • 2011
  • Continuing and Developing the growth, the company should focus on 'time to market of high quality production' and 'cost down'. Due to the complexity of the production, reliability is being one of the important factor. In this study, in particular, focus on parts reliability test improvement about printer product and proceeded. Need test improvement for time to market that is developed, and reduce expense with test period that is required at Reliability Test time of new parts and should high quality level of product. Finally huge Failure Cost (F-COST) occurs because quality level of product drops if parts that accomplish product does not ensure reliability and this is associated by malfunction in marketplace.

  • PDF

태양전지 신뢰성 정보은행 (Solar Cell Reliability Data Bank)

  • 소원섭;오수영
    • Current Photovoltaic Research
    • /
    • 제2권3호
    • /
    • pp.140-145
    • /
    • 2014
  • The globally used PV qualification tests and reports the pass/fail only. Therefore, the reliability of new PV materials and parts can't be compared quantitatively with the reliability of the PV parts and materials in the market. Global PV materials and parts companies test and compare their materials, parts, and modules using the failure-to-test (FTT). However, it takes a long accelerated stress test (AST) until failure. It also needs to test the new and existing materials and parts. Therefore, it requires excessive equipment time and cost. In order to reduce the time and cost, a new reliability enhancement methodology has been developed. It tests the PV materials, parts, and modules in the global market and stores them in the PV reliability database. It reduces the time and cost of the comparison and enhancement of PV reliability. An example of the reliability enhancement of the PV encapsulant, EVA is presented.

프린트 산업에서 부품 신뢰성 시험법 개선 (Case Study of Parts Reliability Improvement)

  • 김판수;한기웅;이지혜
    • 대한안전경영과학회지
    • /
    • 제12권3호
    • /
    • pp.153-162
    • /
    • 2010
  • Continuing and Developing the growth, the company should focus on 'time to market of high quality production' and 'cost down'. Due to the complexity of the production, reliability is being one of the important factor. In this study, in particular, focus on parts reliability test improvement about printer product and proceeded. Need test improvement for time to market that is developed, and reduce expense with test period that is required at Reliability Test time of new parts and should high quality level of product. Finally huge Failure Cost (F-COST) occurs because quality level of product drops if parts that accomplish product does not ensure reliability and this is associated by malfunction in marketplace.

Intra-Rater Test-Retest Reliability of Ely's Test Using Smartphone in Patients With Lumbar Extension-Rotation Syndrome

  • Park, Kyue-Nam;Ha, Sung-Min;Chung, Sung-Dae;Kim, Si-Hyun;Jang, Jun-Hyeok
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.46-54
    • /
    • 2012
  • Ely's test is commonly used to assess rectus femoris muscle flexibility. however, a reliability limit of this test was demonstrated by a previous study. In this study, we present an alternative method using an application for a digital horizontal level in a smartphone (DHLS) to complement the reliability limit of Ely's test. The aim of this study was to examine the reliability of Ely's test using DHLS on the pelvis, compared to using visual observation (VO) of pelvic and hip motions. Nineteen patients with lumbar extension-rotation syndrome were recruited for this study. An examiner examined the rectus femoris flexibility (both pass/fail and goniometer scoring) through Ely's test using both DHLS and VO. A retest session was completed two hours later for within-day reliability and seven days later for between-day intra-rater test-retest reliability. Results showed higher Kappa values for pass/fail scoring and higher intraclass correlation coefficient values for goniometer scoring in Ely's test using DHLS, compared to using VO. Measurement error and Bland and Altman plots further demonstrated the degree of intra-rater variance during Ely's test using DHLS in a clinical setting, compared to using VO. These results demonstrated that Ely's test using DHLS showed acceptable reliability compared to using VO. Ely's test using DHLS could be widely used for measuring the rectus femoris muscle flexibility in patients with lumbar extension-rotation syndrome, although the inter-rater reliability needs to be established first.

Study on Properties and Accelerated Life-time Test of Rubber O-ring by Temperature Stress

  • Shin, Young-Ju;Kang, Bong-Sung;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2006년도 학술발표대회 논문집
    • /
    • pp.48-54
    • /
    • 2006
  • In this thesis, accelerated life test (ALT) method and procedure for rubber O-ring are applied to assure specified reliability of the products at guaranteeing the life of the products. Rubber O-ring is parts that keep intensity or make machine operation smoothly on attrition portion of machine and is used to prevent that oil is leaked. Usually. Rubber O-ring used NBR that is copolymer of acrylonitrile and butadiene. this are superior oil resistance, heat resistance, durability of abrasion, cold resistance, chemical resistance etc. The accelerated life test model for rubber O-ring are developed using the relationship between stresses and life characteristics of products. Using the accelerated life test method and the acceleration life test equipment which is developed, we performed life test, collected life data and analyzed the results of tests. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably.

  • PDF

무기체계 시험평가의 신뢰성 향상방안 (The Action of the Reliability Enhancement in Test and Evaluation of the Weapon Systems)

  • 박종완
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권2호
    • /
    • pp.108-123
    • /
    • 2015
  • Test and Evaluation (T&E) have been verifying the level of it's technological skill and the needed operational status of the development weapons. If the overall spectrum of test and evaluation is fulfilled substantially in the production & deployment, the needed level of the weapon system will be enhanced and also the reliability status will become higher considerably. We can know currently these issues through the mass media and all kinds of the news regarding the defense industry and programs. And so this article have studied the method of enhancing reliability of the test and evaluation, the 6 variables were selected through the discussion of the professional group. The the test and evaluation group needs consistently the professional training systems. After DT&E, we have to the event to verify the technical level of the development systems. We have to take the high level of the kinds of the environmental test. Scientific methods like system engineering will be adapted in process of the test and evaluation. The number of suitable test prototype in the test and evaluation is analysed more systematically. And we need to establish the standardization of the test and evaluation. If 6 variables are well analysed and adapted in the working field, the reliability of the test and evaluation will be considerably, the defense industry will take the chance to develope the future-oriented.

풍력발전기용 쓰러스터 브레이크의 신뢰성 평가 (Reliability Evaluation of Thruster Break for Aerogenerator)

  • 정동수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권3호
    • /
    • pp.165-174
    • /
    • 2013
  • Thruster break for aerogenerator performs a role that is stopping the rotor in case of emergency such as strong wind, system abnormality or maintenance check. In this study, failure analysis and test evaluation on the thruster break for aerogenerator are proposed, and the entire process to improve reliability of the product through design improvement is presented. The typical failure case is fatigue and wear, and failure cause on these are identified and improvement plan is presented. Lastly, reliability improvement is established to analyse test results before after the life test.

Reliability of Measured Popliteal Angle by Traditional and Stabilized Active-Knee-Extension Test

  • Kim, Min-Hee;Kim, Yong-Wook;Jung, Doh-Heon;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제16권4호
    • /
    • pp.1-7
    • /
    • 2009
  • The active-knee-extension (AKE) test has been used to measure hamstring muscle length. The traditional AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip fixed by straps, while the stabilized AKE test measures the popliteal angle to the point of resistance with a 90-degree flexion of the hip stabilized using a pressure biofeedback unit providing lumbopelvic stabilization. The purpose of this study was to determine test-retest reliability of the traditional AKE test and stabilized AKE test. Twenty healthy adults participated in the study. The popliteal angles were measured with a digital inclinometer during each test. To assess the test-retest reliability between the 2 test sessions, intraclass correlation coefficients (ICCs) were calculated. The intrasubject coefficient of variation ($CV_{intra}$) was also calculated. To compare the traditional and stabilized AKE tests for changes in pressure, paired t-tests were applied. The results of this study were as follows: 1) ICCs(3,1) value for test-retest reliability was .96 in the traditional AKE test, and was .98 in the stabilized AKE test. 2) The maximal $CV_{intra}$ was 33.7% in the traditional AKE test and 15.7% in the stabilized AKE test. 3) Differences of $6.1{\pm}2.1$ mmHg in pressure were measured in the traditional AKE test, and differences of $1.2{\pm}1.0$ mmHg in pressure were measured in the stabilized AKE test. The results show the traditional and stabilized AKE test to be highly reliable, with test-retest reliability. However, the stabilized AKE test represented less variation and more stabilization than the traditional AKE test. Further study is needed to measure the inter-rater reliability of the stabilized AKE test for generalization and clinical application.

  • PDF

수동적 요추 신전 검사와 엎드린 상태에서 요추 불안정성 검사의 신뢰도와 타당도 (The Reliability and Validity of the Passive Lumbar Extension Test and the Prone Instability Test)

  • 사재민;김선엽
    • 한국전문물리치료학회지
    • /
    • 제18권3호
    • /
    • pp.85-93
    • /
    • 2011
  • The purpose of this study was to establish the reliability and validity of the passive lumbar extension (PLE) test and prone instability test (PIT). Thirty-three subjects (14 males, 19 females) with lower back pain enrolled in the study and the subjects were divided into 2 groups (positive and negative instability groups) on the basis of radiographies of flexion and extension. Reliability was determined by the kappa coefficient and validity was examined using calculated sensitivity, specificity, and the likelihood ratio. The results showed that the reliability of the PLE test was higher than the PIT (intra-rater reliability: k=.86 and k=.81, interrater reliability: k=.65 and k=.62) and the validity of the PLE test was also higher than the PIT (sensitivity: 91% and 62%, specificity: 95% and 85% positive likelihood ratio: 20.00 and 4.10, negative likelihood ratio: .10 and .45). In conclusion, we think that the PLE test was a more reliable and valid method for lumbar instability than the PIT.

가속열화시험을 적용한 MEMS 진공패키지의 신뢰성 분석 및 개선 (Reliability Assessment and Improvement of MEMS Vacuum Package with Accelerated Degradation Test (ADT))

  • 최민석;김운배;정병길;좌성훈;송기무
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제3권2호
    • /
    • pp.103-116
    • /
    • 2003
  • We carry out reliability tests and investigate the failure mechanisms. of the wafer level vacuum packaged MEMS gyroscope sensor using an accelerated degradation test. The accelerated degradation test (ADT) is used to evaluate reliability (and/or life) of the MEMS vacuum package and to select the accelerated test conditions, which reduce the reliability testing time. Using the failure distribution model and stress-life model, we are able to estimate the average life time of the vacuum package, which is well agreed with the measured data. After improving several package reliability issues such as prevention of gas diffusion through package, we carry out another set of accelerated tests at the chosen acceleration level. The results show that reliability of the vacuum packaged gyroscope has been greatly improved and can survive without degradation of performance, which is the Q-factor in gyroscope sensor, during environmental stress reliability tests.

  • PDF