Real-time Fuzzy Tuned PID Control Algorithm (실시간 퍼지 동조 PID 제어 알고리즘)

  • Choi Jeong-Nae;Oh Sung-Kwun;Hwang Hyung-Soo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2005.11a
    • /
    • pp.423-426
    • /
    • 2005
  • In this paper, we proposed a PID tuning algorithm by the fuzzy set theory to improve the performance of the PID controller. The new tuning algorithm for the PID controller has the initial value of parameter Kp, $\tau_{I}$, $\tau_{D}$. by the Ziegler-Nichols formula that uses the ultimate gain and ultimate period from a relay tuning experiment. We will get the error and the error rate of plant output corresponding to the initial value of parameter and fnd the new proportion gain(Kp) and the integral time ($\tau_{I}$) from fuzzy tuner by the error and error rate of plant oueut as a membership function of fuzzy theory. This fuzzy auto tuning algorithm for PID controller considerably reduced the overshoot and rise time as compared to any other PID controller tuning algorithms. And in real parametric uncertainty systems, it constitutes an appreciable improvement of performance. The significant property of this algorithm is shown by simulation

  • PDF

The Development and the Performance Test of Bay Controller for the High-Voltage Gas Insulated Switchgear (초고압 가스절연개폐기의 베이 컨트롤러 개발 및 성능시험)

  • Woo, Chun-Hee;Lee, Bo-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.179-184
    • /
    • 2010
  • The digital substation automation system has contributed hugely to increasing the stability of power systems by providing not only protection and control of power systems but diagnostic features alongside them. Digital substation automation systems in the scale of substations consist of integrated operation systems and intelligent electronic devices. The main intelligent electronic devices currently in use are digital protection relays and the bay controllers in Gas insulated switchgears. Proficiently accomplishing the coordination of protection within the power system as a means of ensuring reliability and contriving for the stability of power supply through connection of function, the application of bay controllers is crucial, which collectively manage the protection relay at the bay level in order to achieve both. In this research, the bay controllers to be used in high-voltage Gas insulated switchgear has been localized, and in particular, the logic function and editor required in order to minimize the complicated hardware-like cable connections in the local panel have been developed. In addition, to ensure the strength and reliability of the bay controller hardware developed herein, the type tests from KERI have been successfully completed.

Design and Implementation of High Sensitivity Single Power Factor Meter. (고감도 단상력률계의 설계 및 시작)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.15 no.2
    • /
    • pp.55-60
    • /
    • 1979
  • The forming and design method of single power factor meter is suggested and the sensitive phase angle detect circuit of current and voltage of load was dealt with. In this paper, in order to control and detect of phase angle of the current and voltage, operational amplifier comparator circuit and R-C phase shift circuit was used, and to detect the controlled voltage wave form, the transister chopper pair circuit was used. The test result of this power factor meter was good and reliable at the full range of power factor.

  • PDF

Performance Analysis of the GOOSE Transmission of an IED Considering Network Redundancy (네트워크 이중화를 고려한 IED GOOSE 전송에 관한 성능 분석)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.75-80
    • /
    • 2009
  • In order to prevent loss of communication packets and drop of transmission speed owing to the network fault occurrence, it should be considered network redundancy. That is why a messages of IED GOOSE is the critical signal in charge of protection and control of the substation. So most of users implement the substation automation system with Hybrid network topology ant IED supporting double ethernet ports. Because IEC 61850 GOOSE conformance test is limited in the functional test, this paper suggests how to test the performance of IED GOOSE transmission considering Network redundancy, and describes the analysis of an example test on real IEDs and how to impact the IED GOOSE performance to the substation automation system.

Performance improvement of PV_system's inverter that use transformer tap (변압기 탭을 이용한 태양광인버터의 성능개선)

  • Park Noh-Sik;Park Sung-Jun;Kim Kwang-Heon;Lim Young-Cheol;Kwon Soon-Jae;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.511-514
    • /
    • 2004
  • Proposed about new inverter that can use in PV system in this paper. Multi_level inverter that used inverter makes use of 4 transformers is basis, primary winding of each transformer voltage as can do step_up or step_down to appropriate voltage space tap lake. Put circuit that tap that turn in transformer connects properly according to inhibit signal that sense change of input voltage (output voltage of solar cell place) and transformer secondary voltage controls point of contact of relay so that get into fixed output voltage. As a result, can minimise relative harmonic content despite change width of input voltage are wide because number of output voltage level of multi_level inverter does not decrease. Because proposed circuit manufactures is easy and control is easy and is no burden of cost price rise economically, commercialization expected to do easily and this study examined propriety of action as that compose and experiments proposed circuit.

  • PDF

SHD Digital Cinema Distribution over a Fast Long-Distance Network

  • Takahiro Yamaguchi;Daisuke Shirai;Mitsuru Nomura;Kazuhiro Shirakawa;Tatsuya Fujii;Tetsuro Fujii;Kim, io-Oguchi
    • Journal of Broadcast Engineering
    • /
    • v.9 no.2
    • /
    • pp.119-130
    • /
    • 2004
  • We have developed a prototype super-high-definition (SHD) digital cinema distribution system that can store, transmit, and display eight-million-pixel motion pictures that have the image quality of a 35-mm film movie. The system contains a movie server, a real-time decoder, and an SHB projector. Using a Gigabit Ethernet link and TCP/IP, the server transmits JPEG2000 compressed motion picture data streams to the decoder at transmission speeds as high as 300 Mbps. The received data streams are decompressed by the decoder, and then projected onto a screen via the projector. By using an enlarged TCP window, multiple TCP streams, and a shaping function to control the data transmission quantity, we achieved real-time streaming of SHD movie data at about 300 Mbps between Chicago and Los Angeles, a distance of more than 3000 km. We also improved the decoder performance to show movies with Image qualities of 450 Mbps or higher. Since UDP is more suitable than TCP for fast long-distance streaming, we have developed an SHD digital cinema UDP relay system, in which UDP is used for transmission over a fast long-distance network. By using four pairs of server-side-proxy and decoder-side-proxy, 450-Mbps movie data streams could be transmitted.

Detection and Management of Misbehaving Node in Tactical Ad-Hoc Networks (전술 Ad-hoc 네트워크에서의 비정상행위 노드 탐지 및 관리)

  • Jang, Beom-Geun;Lee, Soo-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.333-343
    • /
    • 2009
  • Tactical Information Communication Network(TICN) is a concept-type integrated Military Communication system that enables precise command control and decision making by unifying the diversified military communication network and conveying diverse range of battle field information on real-time, at right place at right time. TICN is designed to advance into high speed, large capacity, long distance wireless relay transmission. To support mobility in battlefield environments, the application of Ad-hoc networking technology to its wireless communication has been examined. Ad-hoc network is consist of mobile nodes and nodes in the network depends on the cooperation of other nodes for forwarding of packets. In this context, some non-cooperating nodes may delay forwarding of packets or drop the packets. This may hamper the network as a whole and disrupt communication between the cooperating nodes. To solve this problem, we present a solution with a Node Weight Management Server(NWMS), which manages each node's weight according to its behavior in local area. When the NWMS detects misbehaving node, it increases the node's weight. If the node's weight exceeds a predefined threshold then the NWMS broadcasts the node's information into network to isolate the misbehaving node from the network. These mechanisms show that they are highly effective and can reliably detect a multitude of misbehaving node.

The transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment used for electrical durability test for magnetic switch (IEC60947-4에 따른 전자개폐기 전기적 수명시험설비의 과도현상을 고려한 SCR최적 정격선정에 대한 연구)

  • Ryu Haeng Soo;Kim Kab Dong;Han Gyu Hwan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.354-356
    • /
    • 2004
  • This paper is the transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment(AC3 TE) used for electrical durability test for magnetic switch according to IEC60947-4 Annex B by utilizing EMTP -ATPDraw. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. The key cost of AC3 TE is the SCR ratings. The more decreases SCR ratings, the more decreased the cost is, but it is impossible to ensure the reliability. On the other hand, the more increases SCR ratings, the more increased the cost is. Thereupon, in this paper after the testing circuit is simulated by using EMTP-ATPDraw the SCR ratings will be applied in order to guarantee the testing reliability of PT&T(Power Testing and Technology institute in LG Industrial Systems Co.,Ltd.).

  • PDF

A Simple Cooperative Transmission Protocol for Energy-Efficient Broadcasting Over Multi-Hop Wireless Networks

  • Kailas, Aravind;Thanayankizil, Lakshmi;Ingram, Mary Ann
    • Journal of Communications and Networks
    • /
    • v.10 no.2
    • /
    • pp.213-220
    • /
    • 2008
  • This paper analyzes a broadcasting technique for wireless multi-hop sensor networks that uses a form of cooperative diversity called opportunistic large arrays (OLAs). We propose a method for autonomous scheduling of the nodes, which limits the nodes that relay and saves as much as 32% of the transmit energy compared to other broadcast approaches, without requiring global positioning system (GPS), individual node addressing, or inter-node interaction. This energy-saving is a result of cross-layer interaction, in the sense that the medium access control (MAC) and routing functions are partially executed in the physical (PHY) layer. Our proposed method is called OLA with a transmission threshold (OLA-T), where a node compares its received power to a threshold to decide if it should forward. We also investigate OLA with variable threshold (OLA-VT), which optimizes the thresholds as a function of level. OLA-T and OLA-VT are compared with OLA broadcasting without a transmission threshold, each in their minimum energy configuration, using an analytical method under the orthogonal and continuum assumptions. The trade-off between the number of OLA levels (or hops) required to achieve successful network broadcast and transmission energy saved is investigated. The results based on the analytical assumptions are confirmed with Monte Carlo simulations.

The Design of Two-Way Automatic Communication System using Mobile Instant Messenger (모바일 인스턴스 메신저를 이용한 양방향 자동화 통신 시스템 설계)

  • Lee, Daesik;Lee, Yongkwon;Jang, Chungryong
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.1
    • /
    • pp.97-109
    • /
    • 2015
  • In this paper, we design and implement a two-way automatic communication system using a mobile instant messenger that can provide a customized service through a real-time two-way communication using a mobile instant messaging service. Two-way automatic communication system using a mobile instant messenger can improve the quality and quantity of information in real-time update of the information through the feedback. In addition, since it is communicated by using a mobile Instant Messanger in 1:1 there is no concerns that is recognized as spam, as well as it is possible to provide customized information for each user. Two-way automatic communication system using a mobile instant messanger shows the difference of the speed according to the data input time in typing by hands in result of comparing the time to input a date and the processing speed to search a data. Therefore in category treatment, command processing and natural language processing, Category treatment way is the most excellent in aspect of data processing speed, otherwise in aspect of the total speed to combine the data input time and the processing time, the command processing way is the best method.