• 제목/요약/키워드: relative bond strength

검색결과 81건 처리시간 0.031초

Bonding of nano-modified concrete with steel under freezing temperatures using different protection methods

  • Yasien, A.M.;Bassuoni, M.T.
    • Computers and Concrete
    • /
    • 제26권3호
    • /
    • pp.257-273
    • /
    • 2020
  • Concrete bond strength with steel re-bars depends on multiple factors including concrete-steel interface and mechanical properties of concrete. However, the hydration development of cementitious paste, and in turn the mechanical properties of concrete, are negatively affected by cold weather. This study aimed at exploring the concrete-steel bonding behavior in concrete cast and cured under freezing temperatures. Three concrete mixtures were cast and cured at -10 and -20℃. The mixtures were protected using conventional insulation blankets and a hybrid system consisting of insulation blankets and phase change materials. The mixtures comprised General Use cement, fly ash (20%), nano-silica (6%) and calcium nitrate-nitrite as a cold weather admixture system. The mixtures were tested in terms of internal temperature, compressive, tensile strengths, and modulus of elasticity. In addition, the bond strength between concrete and steel re-bars were evaluated by a pull-out test, while the quality of the interface between concrete and steel was assessed by thermal and microscopy studies. In addition, the internal heat evolution and force-slip relationship were modeled based on energy conservation and stress-strain relationships, respectively using three-dimensional (3D) finite-element software. The results showed the reliability of the proposed models to accurately predict concrete heat evolution as well as bond strength relative to experimental data. The hybrid protection system and nano-modified concrete mixtures produced good quality concrete-steel interface with adequate bond strength, without need for heating operations before casting and during curing under freezing temperatures down to -20℃.

초고강도 콘크리트를 활용한 고온가열 이후의 탄소 보강근과 철근의 잔류 부착성능 평가 (Evaluation of Residual Bond Stress between Carbon-fiber Reinforced Polymer and Steel Rebar Using Ultra-High-Performance-Concrete after Elevated Temperature)

  • 유선재;이호진;원천봉;윤영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.169-176
    • /
    • 2021
  • 본 연구에서는 고온가열 이후의 탄소 보강근의 잔류 부착 강도 평가를 위하여 상온, 150℃에 따른 부착실험을 수행하였으며, 탄소 보강근과의 비교를 위한 D10 및 D13 철근도 고온 가열한 이후 잔류 부착 강도를 평가하였다. 실험 결과, 150℃ 가열 이후 탄소 보강근의 부착 강도는 상온 대비 약 9.94% 감소하였다. 반면 가열 이후 D10 철근 및 D13 철근 모두 탄소 보강근 대비 부착 강도 감소율이 적게 나타났다. 또한 온도 가열 이후 최대부착 강도에서 발생한 슬립도 탄소 보강근과 철근 모두 줄어드는 경향을 보였다. 이를 통해 고온가열에 따른 부착 강도와 슬립 감소의 상관관계를 확인하였으며, 부착-슬립 곡선을 나타내었다. 최종적으로는 실험 결괏값을 상대부착 강도로 나타냄으로써 가열 이후 탄소 보강근 및 철근의 잔류 부착성능을 확인하고자 하였다.

전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택 (A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure)

  • 한재익;손우성
    • 대한치과교정학회지
    • /
    • 제28권6호
    • /
    • pp.955-974
    • /
    • 1998
  • 적절한 전단접착강도를 가지면서 법랑질손상과 브라켓파절을 적게 일으키는 브라켓-접착제의 그룹을 찾아내기 위하여 전단접착강도, 법랑질손상, 브라켓탈락양상, 브라켓 주위의 밀봉과 법랑질-접착제-브라켓 사이의 긴밀도를 연구하였다. 교정치료 목적으로 발치한 240개의 치아를 각각 10개씩 24개의 군으로 나누어서 브라켓을 접착한 후 48시간 후에 전단접착강도를 측정하고 브라켓 탈락 양상을 조사하였다. 또한 브라켓 주위의 밀봉과 법랑질-접착제-브라켓 사이의 긴밀도를 평가하기 위하여 브라켓이 접착된 치아를 반으로 자른 후 주사전자현미경상에서 관찰하였다. 6종류의 브라켓과 4종류의 접착제가 사용되었으며 브라켓은 Image, Plastic, Crystaline, Fascination, Transcend, metal bracket을 사용하였으며 접착제로는 No-mix, Light-Bond, OrthoLC, Superbond C&B가 사용되었다. 이와같은 연구로부터 다음과 같은 결론을 내렸다. 1. 전단접착강도는 Fascination-Light Bond 군에서 36.58 Kg(410.07 Kg/$cm^2$)으로 가장 높았으며 Image-OrthoLC 군에 서 8.93 B◎ (75.51 Kg/$cm^2$)으로 가장 낮았다. OrthoLC를 접착제로 사용하였을 때 전단접착강도는 다른 접착제를 사용하였을 때 보다 비교적 낮았다. 2. 접착제의 종류에 관계없이 Fascination bracket의 전단접착강도는 비교적 높았으며 Image, Plastic bracket의 전단접착강도는 비교적 낮았다. Crystaline, Transcend bracket의 전단접착강도는 metal bracket의 전단접착강도와 비슷하거나 낮았다. 3. 전단접착강도와 법랑질 파절, 브라켓 파절은 상관관계가 있었으며, 접착강도가 증가할수록 법랑질 파절과 브라켓 파절은 증가하였다. 4. OrthoLC를 접착제로 사용하였을 때 법랑질 파절과 브라켓 파절은 일어나지 않았으나 Superbond C&B를 접착제로 사용하였을 때는 법랑질 파절과 브라켓 파절의 빈도가 높았다. 5. No-mix, Light-Bond를 접착제로 사용하였을 때 브라켓 주위의 밀봉과 법랑질-접착제-브라켓의 긴밀도는 양호하였다. 접착제의 종류에 관계없이 Ceramic bracket에서 접착제-브라켓의 긴밀도는 양호하였다. 6. 적절한 전단접착강도를 가지면서 법랑질 파절과 브라켓 파절을 일으키지 않는 군은 Crystaline-No mix, Crystaline Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond, metal-OrthoLC군이였다.

  • PDF

심미수복재의 수복방법과 광조사기기에 따른 치질과의 인장결합강도에 관한 연구 (A STUDY ON THE TENSILE BOND STRENGTH TO TOOTH STRUCTURE OF TOOTH COLORED MATERIALS ACCORDING TO FILLING METHODS AND LIGHT CURING UNITS)

  • 황호길;김영관;오행진
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.652-663
    • /
    • 1996
  • The purpose of this study was to evaluate the tensile bond strength to tooth structure of composite resin and glass ionomer cement according to filling methods and light curing units. In this study, two class V cavities were prepared on the buccal surface of each tooth of 140 extracted human molars, and they were randomly assigned into 3 experimental groups with 40 teeth and control group with 20 teeth. And then, each experimental groups subdivided into 2 groups(A,B) according to light curing units. The cavities of each group were filled with the CLEARFIL FII self curing resin(Control Group), Z-100 light curing resin(Group 1), Vitremer$^{TM}$ light curing glass ionomer cement(Group 2) and Z-100 light curing resin over the Vitrebond$^{TM}$ liner(Group 3). And subdivided A Group used Argon Laser(SPECTRUM$^{TM}$, U.S.A.), B Group used XL 1,000 curing light (3M, U.S.A.). The specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ five hundred times. After thermocycling, specimens were stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then, the tensile bond strength of specimens were calculated with Universal Testing Machine(AGS-100A, Japan). The results were as follows : 1. Among the experimental groups, the group 2-B showed the highest tensile bond strength ($18.89{\pm}7.80$) and the group 1-A showed the lowest tensile bond strength ($11.68{\pm}2.28$). There was significant difference between group 2-B and group 1-A(p<0.01). 2. Between the light curing units, the XL 1,000 unit showed higher tensile bond strength ($16.63{\pm}3.20$) than that of the Argon Laser unit ($13.73{\pm}2.30$). There was significant difference between XL 1,000 and Argon Laser(p<0.01). 3. About filling methods and materials, the group 2 showed the highest tensile bond strength ($17.56{\pm}1.89$) and the group 1 showed the lowest tensile bond strength($13.03{\pm}1.90$). There was significant difference between group 2 and group 1,3(p<0.01). In conclusion, the results showed that the glass-ionomer cement that cured by XL 1,000 light curing unit demonstrated significantly higher tensile bond strength than other curing unit and filling methods.

  • PDF

폴리우레탄 개질 아스팔트 바인더를 사용한 포트홀 응급 보수재의 성능평가 (Evaluation of Emergency Pothole Repair Materials using Polyurethane-Modified Asphalt Binder)

  • 김영민;임정혁;황성도
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.43-49
    • /
    • 2015
  • PURPOSES : The objective of this study is to develop new pothole repair materials using polyurethane-modified asphalt binder, and to evaluate them relative to current pothole repair materials in order to improve the performance of repaired asphalt pavement. METHODS : In the laboratory, polyurethane-modified asphalt binder is developed, and then asphalt binder is added to produce pothole repair materials. In order to evaluate the properties of this new pothole repair material, both an indirect tension strength test and a direct tension strength test are performed to measure the material strength and bond strength, respectively. Additionally, the basic material properties are evaluated using the asphalt cold mix manual. The strength characteristics based on curing times are evaluated using a total of 7 types of materials (3 types of current materials, 2 types of new materials, and 2 types of moisture conditioned new materials). The indirect tension strength tests are conducted at 1, 2, 4, 8, 16, and 32 days of curing time. The bond strength between current HMA(Hot Mix Asphalt) and the new materials is evaluated by the direct tension strength test. RESULTS AND CONCLUSIONS : Overall, the new materials show better properties than current materials. Based on the test results, the new materials demonstrate less susceptibility to moisture, faster curing times, and an improved bond strength between HMA and the new materials. Therefore, the use of the new materials reported in this study may lead to enhanced performance of repairs made to asphalt pavement potholes.

콘크리트중 코팅철근의 부착응력에 대한 기초적 연구 (A Study on the Bond Strength of Coated Rebar in Concrete)

  • 문한영;김성수;류재석;김성섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.127-132
    • /
    • 1996
  • Recently in the country a corrosion of steel is accelerated due to using of sea sand including salts, and critical problem on the durability of concrete structure is occured. Thus a control of steel corrosion is very important in the stability of structure. Coated steel is in use with a method of steps of steel corrosion in U.S,A. Japan etc, and as well in domestic case the manufactured coating steel of three types is on the market. Those are Epoxy coated steel, Zinc-strength, concrete specimen size, bar diameter, which can affect bond characteristics between steel and concrete in order to know their relative bond characteristics.

  • PDF

온간금형에 의한 클래드판재(STS304-A1050-STS304)의 드로잉성 연구 (A Study on the Drawability of Clad Sheet Metal (STS304-A1050-STS304) by Warm Draw Die)

  • 류호연;김종호;류제구
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 금형가공 심포지엄
    • /
    • pp.136-143
    • /
    • 2002
  • Warm draw die technique which is one of the new forming technologies to improve formability of sheet metal is applied to the cylindrical and square cup drawing of stainless-aluminum clad sheets. In experiments the temperature of die and blank holder is varied from room temperature to $180^{\circ}C$, while the punch is cooled by circulation of coolant to increase the fracture strength of workpiece on the punch comer area. Test materials chosen for experiments are STS304-A1050-STS304 clad sheets. Teflon film as a lubricant is used on both sides of a workpiece. The limit drawing ratio and relative drawing depth as well as quality of drawn cups(distribution of thickness)are investigated and validity of warm drawing process is also discussed. No separation between each laminated material after drawing occurred through inspection by microscope as well as application of penetrant remover and bond strength test. Therefore, warm forming technique was confirmed to give better results in deep drawing of stainless clad sheet metal.

  • PDF

Bond Strength of Super-CFRP Rod in Concrete

  • Seo, Sung-Tag
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.29-34
    • /
    • 2006
  • Elastic modulus, tensile and bond capacities are important factors for developing an effective reinforcing action of a flexural member as a reinforcing material for concrete structures. Reinforcement must have enough bond capacity to prevent the relative slip between concrete and reinforcement. This paper presents an experimental study to clarify the bond capacity of prestressed carbon fiber reinforced polymer(CFRP) rod manufactured by an automatic assembly robot. The bond characteristics of CFRP rods with different pitch of helical wrapping were analyzed experimentally. As the result, all types of CFRP rods show a high initial stiffness and good ductility. The mechanical properties of helical wrapping of the CFRP rods have an important effect on the bond of these rods to concrete after the bond stress reached the yield point. The stress-slip relationship analyzed from the pull-out test of embedded cables within concrete was linear up to maximum bond capacity. The deformation within the range of maximum force seems very low and was reached after approximately 1 mm. The average bond capacity of CF20, CF30 and CF40 was about 12.06 MPa, 12.68 MPa and 12.30 MPa, respectively. It was found that helical wrapping was sufficient to yield bond strengths comparable to that of steel bars.

도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구 (The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal)

  • 김희진;김부섭
    • 대한치과기공학회지
    • /
    • 제32권3호
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

도재소부전장관용 합금의 납착방법에 따른 납착부 굽힘강도에 대한 연구 (A STUDY ON FLEXURE STRENGTH OF THE SOLDER JOINTS FORMED USING VARIOUS SOLDERING TECHNIQUES FOR CERAMO-METAL ALLOYS)

  • 김진열;전영찬
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.191-205
    • /
    • 1993
  • In order to compare the strength of soldered joints relative to the various sol dering method, soldering processes were performed using Palladium based ceramo-metal alloy(Bond-on 4)and Nickel-cromium alloy(Vera Bond). The obtained data include difference in strength between presoldering and postsoldering The data also contain difference among postsoldered groups for 3 difference soldering methods(torch, infrared. Oven) The following results were obtained : 1. For postsoldering with Pd alloy, the oven-using group showed the highest strength while the difference in strength between the torch-using group and the infrared machine group was negligible. 2. For Pd alloy with the torch method, postsoldering resulted in the higher strength than presoldering. 3. There was a negligible difference in strength between presoldering and postsoldering when Ni-Cr alloy with torch method is used. 4. Through microscopic study of the fractured surfaces, the torch-using group showed more porosity than both the oven-using and the infrared machine groups. 5. In terms of fracturing patterns, the oven-using group showed adhesive failure while both the torch and the infrared machine groups showed cohesive failure and cohesive-adhesive failure.

  • PDF