• Title/Summary/Keyword: relative accuracy

Search Result 1,302, Processing Time 0.027 seconds

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

Determination of chlorophenols from the industrial wastewater by GC/MS (GC/MS를 이용한 산업폐수중의 염화페놀류 분석)

  • Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.320-328
    • /
    • 2005
  • The most common five chlorophenols (4-chloro-3-methylphenol, 2,4,5-trichlorophenol, 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol, pentachlorophenol) were determined from the industrial wastewater by GC/MS. The samples were collected from the petrochemical company, textile company and leather making company. The developed analytical method was modified by USEPA Method 3510. The samples were extracted with dichloromethane under pH 2 and pH 5-6, and determined by the GC/MS with SIM mode. There were good linearities (above $R^2=0.9943$) on e ranges of the 0.1 ng/mL~10 ng/mL and 0.5 ng/mL~10 ng/mL, and the limit of detection were between 0.1 ng/mL and 0.5 ng/mL. The absolute recoveries were measured at the concentration of 1, 5, and 10 ng/mL, and the recovery was 71.6~98.9% except for PCP. The relative standard deviation (RSD) was 1.2~14.3% and it gave a good reproducibility for the assay. The bias, which shows the accuracy, was a good although it was a little high values (11.3~22.1%) at the low concentration (1 ng/mL).

An Empirical Study on the Consumption Function of Korean Natural Gas for City Gas - Using Time Varying Coefficient Time Series Model - (한국 도시가스용 천연가스의 소비함수에 대한 실증분석 - 시간변동계수(TVC) 시계열모형 활용 -)

  • Kim, Jum-Su;Yang, Chun-Seung;Park, Jung-Gu
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.318-329
    • /
    • 2011
  • This study focuses on enhancing the accuracy of consumption function of Korean natural gas for city gas. It is using time-series model with time-varying coefficients taking into account the recent abnormal temperature phenomenon and the changing gross domestic product (GDP) as important variables. This study estimates the cointegrating regression model for the long-run estimation and the error correction model for the short-run estimation. The consumption function of Korean natural gas is estimated to be influenced by the time-varying coefficients of GDP and temperature. Using the estimated time-series model with time-varying coefficients, this study forecasts the consumption of natural gas for city gas from July 2011 to December 2012. The consumption in 2011 would be 18,303 thousand tons, which is little different from the imported 18,681 thousand tons. The consumption of natural gas for city gas in 2012 is forecast to be 19,213 thousand tons. The consumption model of this study is needed to extend by considering the relative prices between natural gas and its substitutes, the scale of consumers and others.

Development of Analytical Methods of Hyperoside from Rosa canina L. (Rosa canina L. 중 hyperoside의 시험법 개발 연구)

  • Oh, Jae Myoung;Lee, Hwa Jung;Bahn, Kyeong Nyeo;Seo, Il Won;Lee, Young Joo;Lee, Jin Hee;Park, Ji Min;Kang, Tae Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.173-177
    • /
    • 2015
  • Rosa canina L. is health functional food materials that can help to temporarily relieve symptoms of arthritis. This study has been conducted to develop and validate analytical methods for hyperoside of Rosa canina L.. Methods based on HPLC with ultraviolet detection (UVD) were established through instrumental analytical conditions, and the examination of data, such as domestic and foreign reliable methods and journals. HPLC UVD analysis using Capcell Pak $C_{18}$ MG II column at 353 nm was determined on test through the column, mobile phase. The validation has been performed on the method to determine linearity, accuracy, limits of quantification (LOQ) and repeatability for hyperoside. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.999, and the LOQ was $0.393{\mu}g/mL$. Relative standard deviation (RSD) values of data from repeatability precision was between 0.6 and 2.6%. Recovery rate test at hyperoside scored between 98 and 99%. These results indicate that the established HPLC method is very useful for the determination of hyperoside in Rosa canina L. to develop a health functional material.

Development of an Analytical Method for the Determination of Dexamethasone in Bovine Milk Using Liquid Chromatography Coupled to Tandem Mass Spectrometry (LC-MS/MS를 이용한 우유 중 덱사메타손의 잔류 분석법 개발)

  • Cha, Chun-Nam;Park, Eun-Kee;Yoo, Chang-Yeul;Lee, Sung Joong;Son, Song-Ee;Kim, Suk;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.5
    • /
    • pp.418-423
    • /
    • 2017
  • An analytical method for the determination of dexamethasone (DM) in bovine milk samples was developed and validated using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Milk samples were extracted by the liquid-liquid extraction based on acetonitrile. The chromatographic separation was achieved on a reverse phase $C_{18}$ column with gradient elution using a mobile phase of 0.1% formic acid in 95% acetonitrile. The procedure was validated according to the Ministry of Food and Drug Safety guideline determining accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ). Mean recoveries of DM from spiked milk samples (25, 125, and 1,250 ng/mL) were 98.9-109.6%, and the relative standard deviation was between 1.7 and 4.4%. Linearity in concentration range of 12.5-1,250 ng/mL was obtained with the correlation coefficient ($r^2$) of 0.9997. LOD and LOQ for the investigated DM were 0.15 and 0.5 ng/mL depending on milk samples, respectively. This method was reliable, sensitive, economical and suitable for routine monitoring of DM residues in bovine milk.

Determination of Post-harvest Fungicide in Citrus Fruits Using LC-MS (LC-MS를 이용한 감귤류의 수확 후 처리 살균제 분석)

  • Choi, Su-Jeong;Kim, Eun-Jeong;Lee, Jae-In;Cho, In-Soon;Park, Won-Hee;Hwang, In-Sook;Kim, Moo-Sang;Kim, Gun-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.409-415
    • /
    • 2013
  • Post-harvest fungicide residue was measured in citrus fruits. Samples were collected from local markets in Seoul and analyzed using liquid chromatography coupled with mass spectrometry (LC-MS). LC-MS results were validated for the assay of pesticides by using linearity, accuracy, precision, and limits of detection and quantification. The linearity in the concentration ranged from 0.005 to 2.0 mg/kg ($R^2$ >0.999). Sample recoveries ranged from 80.2 to 98.3% with relative standard deviations below 4.0% for spiking levels from 0.01 to 1.0 mg/kg. The limits of detection ranged between 0.002 and 0.008 mg/kg, and the limits of quantification ranged between 0.006 and 0.027 mg/kg. The highest residue levels for carbendazim, thiabendazole, imazalil, and azoxystrobin in citrus fruits were 0.541, 0.958, 0.721, and 0.052 mg/kg, respectively. The pesticide residues found in citrus fruits were blow maximum residue limits (MRLs) and are not a serious public health problem.

Determination of 11 Illicit Compounds in Dietary Supplements Using High-Performance Liquid Chromatography and Liquid Chromatography-Tandem Mass Spectrometry

  • Shin, Dasom;Kang, Hui-Seung;Kim, Hyung-soo;Moon, Guiim
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.326-333
    • /
    • 2020
  • In this work, we developed an analytical method for determining 11 illicit compounds in dietary supplements using high-performance liquid chromatography and liquid chromatography-tandem mass spectrometry. Eleven target compounds, including those meant for weight loss (7-keto-dihydroepiandrosterone, buformin, metformin, phenformin, salbutamol, and tolbutamide), sexual enhancement (dihydroepiandrosterone), and relaxation (asarone, kavain, magnoflorine, and picamilon) were screened and confirmed in dietary supplements. Method validation was performed by evaluating the selectivity, linearity, limit of quantification (LOQ), accuracy, and precision according to the Association of Official Analytical Chemists guidelines. The linearity was > 0.993 for all analytes. The LOQs were ranged in 2.1-9.9 ㎍/mL (HPLC-DAD) and 0.002-0.008 ㎍/mL (LC-MS/MS). The accuracies (expressed as recovery) were 90.0-106% (HPLC-DAD) and 83.0-114% (LC-MS/MS). The precision (expressed as the relative standard deviation) was below 10% using HPLC and LC-MS/MS. The proposed method can be used for the surveillance of illicit compounds in dietary supplements.

Forecasts of the BDI in 2010 -Using the ARIMA-Type Models and HP Filtering (2010년 BDI의 예측 -ARIMA모형과 HP기법을 이용하여)

  • Mo, Soo-Won
    • Journal of Korea Port Economic Association
    • /
    • v.26 no.1
    • /
    • pp.222-233
    • /
    • 2010
  • This paper aims at predicting the BDI from Jan. to Dec. 2010 using such econometric techniues of the univariate time series as stochastic ARIMA-type models and Hodrick-Prescott filtering technique. The multivariate cause-effect econometric model is not employed for not assuring a higher degree of forecasting accuracy than the univariate variable model. Such a cause-effect econometric model also fails in adjusting itself for the post-sample. This article introduces the two ARIMA models and five Intervention-ARIMA models. The monthly data cover the period January 2000 through December 2009. The out-of-sample forecasting performance is compared between the ARIMA-type models and the random walk model. Forecasting performance is measured by three summary statistics: root mean squared error (RMSE), mean absolute error (MAE) and mean error (ME). The RMSE and MAE indicate that the ARIMA-type models outperform the random walk model And the mean errors for all models are small in magnitude relative to the MAE's, indicating that all models don't have a tendency of overpredicting or underpredicting systematically in forecasting. The pessimistic ex-ante forecasts are expected to be 2,820 at the end of 2010 compared with the optimistic forecasts of 4,230.

Extraction and Preprocessing Methods for Ginsenosides Analysis of Panax ginseng C.A. Mayer (인삼의 진세노사이드 분석을 위한 추출 및 전처리법)

  • Kim, Geum-Soog;Hyun, Dong-Yun;Kim, Young-Ock;Lee, Sung-Woo;Kim, Young-Chang;Lee, Seung-Eun;Son, Yeong-Deck;Lee, Min-Jeong;Park, Chung-Berm;Park, Ho-Ki;Cha, Seon-Woo;Song, Kyung-Sik
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.6
    • /
    • pp.446-454
    • /
    • 2008
  • An advanced extraction method by ultrasonic extraction with applied solid phase extraction (SPE) has been developed for the determination of simultaneous eight major ginsenosides, namely ginsenosides Rg1, Re, Rf, Rb1, Rg2, Rc, Rb2, and Rd in the root of Panax ginseng. Four extraction methods including n-BuOH reflux extraction (Method A), 70% EtOH reflux extraction (Method B), 50% MeOH reflux extraction with SPE (Method C), and 50% MeOH ultrasonication with SPE clean-up process (Method D) were investigated for the determination of eight major ginsenosides. Total contents of ginsenosides were highest by extraction of Method C as $2.408{\pm}0.011%$. However, Method D was evaluated as relatively simpler and more efficient method due to short extraction time, small solvent consumption and less expensive, compared to conservative reflux method. Ginsenosides were also satisfactorily separated with good resolution and the accuracy range was between 1.05 and 4.06% as relative standard deviation (RSD) by Method D. SPE condition and HPLC condition were further optimized for determination of eight major ginsenosides by the ultrasonic extraction method. Conclusively, ultrasonic extraction of 2 g sample of ginseng using ultrasonic bath and 1 loading for SPE was evaluated as proper condition for extraction of ginseng.

Surface Deformation and Behavior of Magma Activity Using EDM (EDM을 활용한 지표변화율과 마그마 활동 양상 변화 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.71-81
    • /
    • 2013
  • Measuring the distance between benchmarks placed on a volcano tens to thousands of meters apart can sometimes pinpoint where and when magma is rising toward the surface. Rising magma will sometimes push overlying rocks upward or shove them aside. In either case, one part of the volcano may actually move horizontally relative to another part from as little as a few millimeters to as much as several tens of meters. The challenge in measuring such changes with an electronic distance meter is putting benchmarks in the right places and making frequent measurements between pairs of benchmarks. An electronic distance meter is an instrument that both sends and receives an electromagnetic signal. Depending on the distance between the EDM and reflector, the wavelength of the returned signal will be out of phase with the transmitted signal. The instrument compares the phase of the transmitted and received signals and measures the phase difference electronically. There is a wide range of EDM capabilities in range and precision, but for volcano monitoring purposes, short-range (less than 10 km) to medium-range (less than 50 km) EDM's are typically used. Short-range EDM's transmit and receive the near visible infrared part of the electromagnetic spectrum for measuring distances with an accuracy of about 5 mm.