• 제목/요약/키워드: reinforcing method

검색결과 940건 처리시간 0.026초

그라파이트/구리 복합재료의 기계적 특성에 미치는 그라파이트 형상과 복합재료 제조방법의 영향 (Effects of Graphite Shape and Composite Fabricating Method on Mechanical Properties of Graphite/Copper Composites)

  • 손유한;한준현
    • 한국재료학회지
    • /
    • 제28권10호
    • /
    • pp.601-609
    • /
    • 2018
  • To study the effects of graphite shape and the composite fabricating method on the mechanical properties of graphite/copper (Gr/Cu) composites, a copper composite using graphite flakes or graphite granules as reinforcing phases is fabricated using mechanical mixing or electroless plating method. The mechanical properties of the Gr/Cu composites are evaluated by compression tests, and the compressive strength and elongation of the Gr/Cu composites using graphite granules as a reinforcing phase are compared with those of Cu composites with graphite flakes as a reinforcing phase. The compressive yield strength or maximum strength of the Gr/Cu composites with graphite granules as a reinforcing phase is higher than that of the composites using graphite flakes as a reinforcing phase regardless of the alignment of graphite. The strength of the composite produced by the electroless plating method is higher than that of the composite material produced by the conventional mechanical mixing method regardless of the shape of the graphite. Using graphite granules as a reinforcing phase instead of graphite flakes improves the strength and elongation of the Gr/Cu composites in all directions, and reduces the difference in strength or elongation according to the direction.

부식촉진시험에 의한 콘크리트 내의 철근의 부식 모니터링에 관한 실험적 연구 (An Experimental Study on the Corrosion Monitoring of Reinforcing Steel in Concrete by the Accelerated Corrosion Test)

  • 배수호;정영수;김진영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.543-548
    • /
    • 2001
  • The corrosion monitoring methods of reinforcing steel in concrete are the various methods such as half cell potential method, galvanic current method, resistivity method, polarization resistance method, AC impedance method and etc. In this study, the corrosion monitoring methods of reinforcing steel in concrete were investigated for the test specimens using corrosion inhibitors, zinc-mortar, zinc-plate, respectively. For this purpose, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles(140 days) of wetting($65^{\circ}C$, 90% R.H.) and drying period(15$^{\circ}C$ , 65% R.H.) for the test specimens. As a result, it can be concluded from the test that half cell potential and galvanic current method as monitoring techniques for corrosion were found to be relatively reliable and easily usable method in the field.

  • PDF

Quantitative assessment on the reinforcing behavior of the CFRP-PCM method on tunnel linings

  • Han, Wei;Jiang, Yujing;Zhang, Xuepeng;Koga, Dairiku;Gao, Yuan
    • Geomechanics and Engineering
    • /
    • 제25권2호
    • /
    • pp.123-134
    • /
    • 2021
  • In this paper, the carbon fiber reinforced plastic (CFRP) grids embedded in polymer cement mortar (PCM) shotcrete (CFRP-PCM method) was conducted to repair the degraded tunnel linings with a cavity. Subsequently, the reinforcing effect of the CFRP-PCM method under different degrees of lining deterioration was quantitatively evaluated. Finally, the limit state design method of the M-N interaction curve was conducted to determine whether the structure reinforced by the CFRP-PCM method is in a safe state. The main results indicated that when the cavity is at the shoulder, the lining damage rate is more serious. In addition, the remarkably reinforcing effect on the degraded tunnel linings could be achieved by applying a higher grade of CFRP grids, whereas the optimization effect is no longer obvious when the grade of CFRP grids is too high (CR8); Furthermore, it is found that the M-N numerical values of the ten reinforcing designs of the CFRP-PCM method are distributed outside the corresponding M-N theoretical interaction curves, and these designs should be avoided in the corresponding reinforcing engineering.

3D 스캐너를 활용한 철근 자동검측방식의 현장적용성 연구 (A Study on Application of Automated Inspection System for Rebar Inspection using 3D Scanner)

  • 임현수;김태훈;이명도;김창원;차민수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.157-158
    • /
    • 2019
  • Reinforcing bars are an important material for tensile strength of structures. For this reason, the inspection of the reinforcing bars confirming the layout and omission is very important for the safety of the structures. However, the current method of inspecting of the reinforcing bars through photographs of specific areas is difficult to identify condition all reinforcing bars. And It is also difficult to confirm after completion of a building. Therefore, reinforcing bar inspection using 3D scanner is required for automation of rebar inspection and database construction. For this purpose, this study test application of automated inspection method for rebar inspection using 3D scanner and discuss the effect of this method.

  • PDF

NATM 터널의 대심도 풍화대층에서의 지반거동 및 보강방법 (Ground Behavior and Reinforcing Methods of NATM Tunnel through Deep Weathered Zone)

  • 성화돈;안정환;천병식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1782-1788
    • /
    • 2007
  • This study analyzed ground settlement and ground stress depending on tunnel excavation and the ground reinforcing grouting methods for double line road tunnel through deep weathered zone. Diameter of double line road tunnel was approximately 12m and umbrella arch method and side wall reinforcing grouting were applied. The ring-cut split excavation method and CD-cut excavation method for excavation method were applied. Analysis of failure rate and vertical stress ratio show that the tunnel for which the height of the cover(H) was higher than four times the diameter, it can be considered a deep tunnel. Comparisons of various excavation and ground reinforcement methods were showed that CD-cut method results in lower surface and crown settlement, and lower failure rate than where using Ring-cut split method. In addition the side wall reinforcing grouting resulted in reduction of tunnel displacement and settlement.

  • PDF

남성 재킷의 접착 제작방식과 비접착 제작방식 비교 - 30~49세 남성 재킷을 중심으로 - (Comparison of adhesive and non-adhesive manufacturing methods of men's jacket - Focusing on men's jacket aged 30 to 49 -)

  • 권동국
    • 복식문화연구
    • /
    • 제31권6호
    • /
    • pp.738-755
    • /
    • 2023
  • The purpose of this study is to provide basic data for the production of jackets with high fit by comparing and analyzing the adhesive and non-adhesive production methods of men's jackets. An analysis of the manufacturing method showcased differences between the adhesive and non-adhesive manufacturing methods in the cutting and wick attachment method, the shape and attachment method of the chest reinforcing wick, the sleeve attachment method, and the shoulder pad and sleeve reinforcing cloth attachment method. In evaluating the outfit, the overall fit of the shoulder, the fit of the chest, and the fit of the armpit were found to be high in the non-adhesive production method. In evaluating appearance evaluation, the front shoulder, chest, and sleeve overall appearance showed a high non-adhesive production method. Therefore, in order to increase the wearability of the shoulder pad and the the attachment method of the upper sleeve reinforcing cloth, the non-adhesive production method should be used, and in order to increase the overall wearability and armpit wear of the chest, the difference in the attachment method, and the reinforcement method of the armhole should be used. In addition, to increase the appearance of the jacket, non-adhesive production methods such as differences in wick attachment methods, shoulder pads, sleeve reinforcing cloth, and sleeve attachment methods should be used.

PSC보의 박스화 보강방법의 신뢰성해석 (A Reliability Analysis on the To-Box Reinforcement Method of PSC Beam Bridges)

  • 방명석
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.94-100
    • /
    • 2006
  • The goal of this study is to show the way to increase the safety of deteriorated PSC beam bridges by the to-box reinforcing method. This method is to change the open girder section into the closed box section by connecting bottom flanges of neighboring PSC girders with the precast panels embedding PS tendons at the anchor block. The box section is composed of three concrete members with different casting ages, RC slab, PSC beam, precast panel. This different aging requires a time-dependent analysis considering construction sequences. Reliability index and failure probability are produced by the AFOSM reliability analysis. Transversely five schemes and longitudinally two schemes are considered. The full reinforcing scheme, transversely and longitudinally, shows the highest reliability index, but it requires more cost for retrofit. The partial reinforcing scheme 4, 4-1 are recommended in this study as the economically best scheme.

방청제에 의한 콘크리트 내의 철근 방식법에 관한 실험적 연구 (An Experimental Study on the Corrosion Protection Method of Reinforcing Steel in Concrete by Using Corrosion Inhibitor)

  • 배수호;정영수;권영우;김년산;권혁진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.710-713
    • /
    • 2000
  • The corrosion protection methods of reinforcing steel in concrete are the various methods such as increasing thickness of cover concrete, using of reinforcing bars coated with epoxy, dosage of corrosion inhibitor as concrete admixture, cathodic protection method and etc. The most economical method of them will be the corrosion protection method using corrosion inhibitor as concrete admixture. Therefore, the purpose of this research is to investigate the performance of corrosion protection of ordinary strength and high strength concrete using corrosion inhibitor, respectively. For this purpose, after manufacturing ordinary strength and high strength concrete with and without corrosion inhibitor, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles (140 day) of wetting ($65^{\circ}C$, 90% R.H.) and drying period ($15^{\circ}C$, 65% R.H.). As a result, th high strength concrete using corrosion inhibitor showed an excellent performance of corrosion protection.

  • PDF

이질구조부 보강판의 길이에 따른 혼합구조보의 특성에 관한 연구 (A Study on Properties of Composite Beams according to Length of Reinforcing Plate for Different Types of Structure)

  • 이승조;박정민;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.297-302
    • /
    • 2002
  • This paper investigated the properties of flexural behavior of composite beams (end-Reinforced concrete, center-Steel concrete) according to attaching length of main bars to flange, shear reinforcing length for different types of structure. In the preceding study, structural properties of composite beams were investigated according to shear span to depth ratio, attaching method of main bars and shear reinforcing method. Based on these results, a series of experiments was carried out according to attaching length of main bar & reinforcing length for different types of structure. Consequently, as attaching length of main bar and shear reinforcing length increased, composite beams represented higher strength, ductility index and stress mechanism distributed in connection zone of different types of structure.

  • PDF

슬러리법에 의한 탄소섬유보강 시멘트복합체의 제조에서 보강섬유와 계면결착제와의 상관특성 (Characteristics Correlations Between Fiber-Reinforced and Interfacial Adhesion in Carbon fiber reinforced Cement composite Prepared by Slurry Method.)

  • 최응규
    • 한국건축시공학회지
    • /
    • 제2권3호
    • /
    • pp.131-138
    • /
    • 2002
  • The objective of the study is to examine the characteristic correlations between reinforcing carbon fiber and interfacial adhesion agent since the interfacial adhesion strength between reinforcing carbon fiber and matrices is believed to be an essential element influencing the physical properties in carbon fiber reinforced cement composite using slurry method. The integrity of interfacial adhesion between reinforcing fiber and cement not only affects the quality of fiber reinforced cement composite but also influences to a large degree the physical properties of the cement composite when producing carbon fiber reinforced cement composite using slurry method. Having analyzed the physical properties 1.e., water content, tensile strength, flexural strength and flexural toughness of carbon fiber reinforced cement composite specimens, C-PAM(cation polyacrylamide) was determined to be an optimum interfacial adhesion agent. The study has also demonstrated that interfacial adhesion strength varies largely on the content and type of the reinforcing fiber. Judging from magnified view of the tensile shear cross-section using VMS(video microscope system), interfacial adhesion strength between reinforcing fiber and matrices is affected by the type of interfacial adhesion agent. According to the result of the experiments, C-PAM was determined to be an ideal interfacial adhesion agent when using carbon fiber in producing carbon fiber reinforced cement composite with the optimum content of carbon fiber being established.