• 제목/요약/키워드: reinforced concrete filled steel tubular column

검색결과 42건 처리시간 0.028초

Analysis of axial compression performance of BFRRAC-filled square steel tubular column

  • Xianggang Zhang;Jixiang Niu;Wenlong Shen;Dapeng Deng;Yajun Huang
    • Steel and Composite Structures
    • /
    • 제49권4호
    • /
    • pp.457-471
    • /
    • 2023
  • To make up for the performance weaknesses of recycled aggregate concrete (RAC), expand the application range of RAC, and alleviate the environmental problems caused by excessive exploitation of natural coarse aggregates (NCA), this study proposes a basalt fiber-reinforced recycled aggregate concrete (BFRRAC)-filled square steel tubular columns that combines two modification methods of steel tube and fiber, which may greatly enhance the mechanical properties of RAC. The axial compression performance for BFRRAC-filled square steel tubular columns was reported during this study. Seven specimens with different replacement ratios of recycled coarse aggregate (RCA), length-diameter ratios, along with basalt fiber (BF) contents were designed as well as fabricated for performing axial compression test. For each specimen, the whole failure process as well as mode of specimen were discovered, subsequently the load-axial displacement curve has obtained, after which the mechanical properties was explained. A finite element analysis model for specimens under axial compression was then established. Subsequently, based on this model, the factors affecting axial compression performance for BFRRAC-filled square steel tubes were extended and analyzed, after which the corresponding design suggestion was proposed. The results show that in the columns with length-diameter ratios of 5 and 8, bulging failure was presented, and the RAC was severely crushed at the bulging area of the specimen. The replacement ratio of RCA as well as BF content little affected specimen's peak load (less than 5%). As the content of BF enhanced from 0 kg/m3 to 4 kg/m3, the dissipation factor and ductility coefficients increased by 10.2% and 5.6%, respectively, with a wide range.

Shape effect on axially loaded CFDST columns

  • R, Manigandan;Kumar, Manoj
    • Steel and Composite Structures
    • /
    • 제43권6호
    • /
    • pp.759-772
    • /
    • 2022
  • Concrete-filled double skinned steel tubular (CFDST) columns have been used to construct modern structures such as tall buildings and bridges as well as infrastructures as they provide better, lesser weight, and greater stiffness in structural performance than conventional reinforced concrete or steel members. Different shapes of CFDST columns may be needed to satisfy the architectural and aesthetic criteria. In the study, three-dimensional FE simulations of circular and elliptical CFDST columns under axial compression were developed and verified through the experimental test data from the perspectives of full load-displacement histories, ultimate axial strengths, and failure modes. The verified FE models were used to investigate and compare the structural performance of CFDST columns with circular and elliptical cross-section shapes by evaluating the overall load-deformation curves, interaction stress-deformation responses, and composite actions of the column. At last, the accuracy of available design models in predicting the ultimate axial strengths of CFST columns were investigated. Research results showed that circular and elliptical CFDST column behaviors were generally similar. The overall structural performance of circular CFDST columns was relatively improved compared to the elliptical CFDST column.

T-스티프너 보강 콘크리트충전 각형강관 기둥-H형강 보 접합부의 인장거동 (Tensile Behavior of CFT Column-to-H beam Connections with External T-shaped Stiffeners)

  • 강창훈;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.121-130
    • /
    • 2002
  • This paper presents the tensile behavior of a Concrete-Filled Square Steel Tubular (CFT) column to H-beam welded connections. These connections were externally reinforced with T-shaped stiffeners at the junction of CFT column and beam. The tensile loading tests of eighteen tee-joint connections and finite element analysis using ANSYS were carried out. The main parameters of tests are as follows: 1) the thickness of Square Steel Tubular Column : 6 mm, 9 mm, 2) the strength ratios of tensile strength of horizontal stiffeners to tensile strength of beam flange : 70 %, 100 %, 150 %, 3) the strength ratios of shear strength of vertical stiffeners to tensile strength of beam flange : 80 %, 115 %, 160 %. The results of the tests demonstrate that overall behavior and failure modes of all the specimens are governed mainly by the horizontal stiffeners rather than the vertical stiffeners, and the vertical stiffener played only a role in transferring load introduced from beam to column.

비재하 가열실험을 통한 이중강관 CFT기둥의 잔존강도 평가연구 (A Study on the Evaluation of Residual Strength of Double Concrete Filled Tube Column by Unstressed test)

  • 김선희;원용안;최성모
    • 한국강구조학회 논문집
    • /
    • 제24권1호
    • /
    • pp.81-89
    • /
    • 2012
  • 콘크리트 충전강관 기둥은 내부의 콘크리트에 의해 축열효과로 인해 철골기둥에 비해 내화성능이 우수하며, 기둥 단면 내 철근 및 강관을 보강하여 구조적내력 및 내화성능 향상연구가 이루어져 오고 있다. 실제로 보강된 CFT기둥은 고축력을 요구하는 기둥부재로 사용 빈도 수가 증가되고 있는 추세이다. 이러한 상황에서 CFT기둥을 사용한 건축물에 화재가 발생하여 손상을 입게 되었을 경우 성능 저하정도를 정밀하게 측정할 수 있는 기법이 필요하다. 본 연구에서는 화재 발생시 CFT기둥에 대한 내부 온도 분포를 평가 하고, 단면내부의 온도분포에 따라 내부 충전콘크리트와 보강재의 내력 저하 정도를 파악하여 CFT기둥의 전체적인 잔존강도를 평가하고자 한다.

Numerical simulation on the cyclic behavior of ultra-high performance concrete filled steel tubular column

  • Heng Cai;Fangqian Deng
    • Structural Engineering and Mechanics
    • /
    • 제85권5호
    • /
    • pp.693-707
    • /
    • 2023
  • In order to deeply reveal the working mechanism of ultra-high performance concrete (UHPC) filled steel tubular columns (UHPCFSTs) under cyclic loading, a three-dimension (3D) macro-mesoscale finite element (FE) model was established considering the randomness of steel fibers and the damage of UHPC. Model correctness and reliability were verified based on the experimental results. Next, the whole failure process of UHPC reinforced with steel fibers, passive confinement effect and internal force distribution laws were comprehensively analyzed and discussed. Finally, a simplified and practical method was proposed for predicting the ultimate bending strengths of UHPCFSTs. It was found that the non-uniform confinement effect of steel tube occurred when the drift ratio exceeded 0.5%, while the confining stress increased then decreased afterwards. There was preferable synergy between the steel tube and UHPC until failure. Compared with experimental results, the ultimate bending strengths of UHPCFSTs were undervalued by the current code provisions such as AISC360-10, EC4 and GB50936 with computed mean values (MVs) of 0.855, 0.880 and 0.836, respectively. The proposed practical method was highly accurate, as evidenced by a mean value of 1.058.

Cyclic behavior of FRP - crumb rubber concrete - steel double skin tubular columns and beams

  • Li, Danda;Hassanli, Reza;Su, Yue;Zhuge, Yan;Ma, Xing
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.649-661
    • /
    • 2021
  • This paper presents experimental and analytical studies to understand the behavior of crumb rubber concrete (CRC)-filled fiber reinforced polymer (FRP) and steel tube double skin column (DSC) and beam (DSB) members under cyclic loading. The main test variable was the percentage of rubber which ranged from 0 to 40%. For column members, different heights corresponding to different aspect ratios were examined to understand the to understand the effect of DSCs' slenderness on the cyclic response of the columns. the. The behavior of the specimens in terms of failure mode, strain development, energy dissipation, load-displacement response were presented and compared. The ability of the current provisions of the Australian codes to predict the capacity of such double skin members was also evaluated based on the test results. This study concluded that the reduction in the concrete strength was more severe at the material level compared to structural level. Also, as the load changed from axial compression in columns to pure moment in beams the negative effect of rubber percentage on the strength became less significant.

Seismic behavior of energy dissipation shear wall with CFST column elements

  • Su, Hao;Zhu Lihua;Wang, Yaohong;Feng, Lei;Gao, Zeyu;Guo, Yuchen;Meng, Longfei;Yuan, Hanquan
    • Steel and Composite Structures
    • /
    • 제43권1호
    • /
    • pp.55-66
    • /
    • 2022
  • To develop high-efficiency lateral force resistance components for high-rise buildings, a novel energy dissipation shear wall with concrete-filled steel tubular (CFST) column elements was proposed. An energy dissipation shear wall specimen with CFST column elements (GZSW) and an ordinary reinforced concrete shear wall (SW) were constructed, and experimented by low-cycle reversed loading. The mechanical characteristics of these two specimens, including the bearing capacity, ductility, energy dissipation, and stiffness degradation process, were analyzed. The finite-element model of the GZSW was established by ABAQUS. Based on this finite-element model, the effect of the placement of steel-plate energy dissipation connectors on the seismic performance of the shear wall was analyzed, and optimization was performed. The experiment results prove that, the GZSW exhibited a superior seismic performance in terms of bearing capacity, ductility, energy dissipation, and stiffness degradation, in comparison with the SW. The results calculated by the ABAQUS finite-elements model of GZSW corresponded well with the results of experiment, and it proved the rationality of the established finite-elements model. In addition, the optimal placement of the steel-plate energy dissipation connectors was obtained by ABAQUS.

Global seismic performance of a new precast CFST column to RC beam braced frame: Shake table test and numerical study

  • Xu, S.Y.;Li, Z.L.;Liu, H.J.
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.805-827
    • /
    • 2016
  • A new type of precast CFST column to RC beam braced frame is proposed in this paper. A series of shake table tests were conducted to excite a one-third scale six-story model for investigating the global seismic performance of this type of structure against earthquake actions. Particular emphasis was given to its dynamic property, global seismic responses and failure path. Correspondingly, a numerical model built on the basis of fiber-beam-element model, multi-layer shell model and element-deactivation method was developed to simulate the seismic performance of the prototype structure. Numerical results were compared with the measured values from shake table tests to verify the validity and reliability of the numerical model. The results demonstrated that the proposed novel precast CFST column to RC beam braced frame performs excellently under strong earthquake excitations; the "strong CFST column-weak RC beam" and "strong connection-weak member" anti-seismic design principles can be easily achieved; the maximum deflections of precast CFSTC-RCB braced frame satisfied the deflection limitations proposed in national code; the numerical model can properly simulate the dynamic property and responses of the precast CFSTC-RCB braced frame that are highly concerned in engineering practice.

탄소섬유쉬트(CFRP Sheets)로 보강된 폭두께비가 큰 콘크리트 충전 각형강관 기둥의 중심축하중거동 (Axial Loading Behaviors of Square Concrete-Filled Tubular Columns with Large Width-to-Thickness Ratio Retrofitted using Carbon Fiber Reinforced Polymer Sheets(CFRP Sheets))

  • 박재우;유정한
    • 한국강구조학회 논문집
    • /
    • 제26권3호
    • /
    • pp.169-176
    • /
    • 2014
  • 본 연구에서는 콘크리트 충전 각형강관 (CFTP) 단주기둥에 CFRP 쉬트를 횡방향으로 보강하고 중심축하중 실험을 수행하였다. 실험변수는 b/t, CFRP쉬트 보강겹수이며, 총 6개의 실험체가 제작되었다. 실험변수로 사용된 판폭두께비는 b/t는 60, 80, 100이고 CFRP쉬트는 3겹 보강하였다. 실험결과 판폭두께비 100 실험체에서 CFRP쉬트 3겹 보강을 통해 내력을 16% 상승시켜 보강효과를 검증하였다. 내력 저하율을 검토한 결과 국부좌굴이 발생하지 않는 단면강도를 기준으로 최대 41%정도 내력이 저하되었으나, CFRP보강을 통해 32% 정도의 내력이 저하되어 보강효과를 검증할 수 있었다. 하중-변형를 관계를 보면 강재는 항복강도 이전에 국부좌굴이 발생하였으며, CFRP쉬트의 보강을 통해 국부좌굴을 지연시킴을 확인하였다.

외부스티프너와 철근으로 보강한 CFT 기둥-H형강 보 접합부의 거동 (Behavior of Concrete-Filled Tube Column to H-Beam Connections with External Stiffeners and Reinforcing Bar)

  • 강창훈;신경재;오영석;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권1호통권44호
    • /
    • pp.55-63
    • /
    • 2000
  • 본 논문은 콘크리트충전 각형강관 기둥-H형강보 접합부로서 기둥을 관통하는 철근과 T-스티프너를 외부에 보강한 새로운 접합부상세를 제안하고, 5개의 십자형 접합부 실험체를 역대칭 반복가력 실험하였다. 실험변수는 T-스티프너의 길이(200, 250mm), 철근의 직경(HDl6, 19)이다. 실험결과 T-스티프너 길이의 증가가 철근의 강도비 증가보다 내력 및 강성에 미치는 영향이 보다 크고, T-스티프너의 보강만으로도 보붕괴형의 안정적인 이력거동을 나타내었다. 또한, T-스티프너와 강관 코너부의 용접 시에는 취성파괴의 가능성에 주의하고, 본 논문에서 제안한 용접방법을 따르는 것이 적절할 것으로 판단된다.

  • PDF