• Title/Summary/Keyword: refueling

Search Result 250, Processing Time 0.024 seconds

A Development of Simulation Program for CNG Refueling Station (CNG 충전시스템 충전특성해석 프로그램 개발)

  • Yang, Pan-Seok;Kang, Chan-Goo;Kwan, Yong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.331-336
    • /
    • 2001
  • Theoretical approach was taken to the whole CNG refueling process. In particular, this study was focused on the prediction of flow rate at any given piping configuration of CNG system, in order that a simulation program for the CNG refueling system should be developed. The simulation result of refueling process was compared with experimental result obtained from various kinds of fueling configuration. The simulation results showed a satisfactory agreement within 10% errors in fueling time, fueling amount, and residual pressure. The developed program would be used a good engineering tools for estimating fueling performance for a any given CNG station.

  • PDF

Flow Analysis of Check Valve for Hydrogen Vehicle Refueling Line (수소자동차의 연료주입라인용 Check Valve 내의 유동해석)

  • Park, Kyong-Taek;Yeo, Kyeong-Mo;Park, Tae-Jo;Kang, Byeong-Roo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.565-568
    • /
    • 2007
  • The high pressure hydrogen gas refueling system is required for fuel cell vehicle. In this paper, a commercial computational fluid dynamics (CFD) code, FLUENT is adopted to investigate the gas flow characteristics inside the check valve for various refueling and tank pressures. The results showed that the choking phenomena can occur for certain refueling pressures, therefore refueling processes should be divided by multiple stages. And a design method to prevent the seal departure problem which reported in CNG usages is required.

  • PDF

Simulation of Temperature Behavior in Hydrogen Tank During Refueling Using Cubic Equations of State (3차 상태방정식을 이용한 수소 충전 온도 거동 모사)

  • PARK, BYUNG HEUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.5
    • /
    • pp.385-394
    • /
    • 2019
  • The analysis of temperature behavior of a hydrogen tank during refueling is of significance to clarify the safety of the compressed hydrogen storage in vehicles since the temperature at a tank rises with inflow of hydrogen. A mass balance and an energy balance were combined to obtain analytical model for temperature change during the hydrogen refueling. The equation was coupled to Peng-Robinson-Gasem (PRG) equation of state (EOS) for hydrogen. The PRG EOS was adopted after comparison with other four different cubic EOSs. A parameter of the model was determined to fit data from experiments of various inlet flow rates and temperatures. The temperature and pressure change with refueling time were obtained by the developed model. The calculation results revealed that the extent of precooling was more effective than the flow rate control.

A Study on Risk Factors by Analyzing Human Factors during Air Refueling Missions for Fighter Pilots (전투기 조종사의 공중급유 임무 시 인적요인 분석을 통한 위험요인 연구)

  • Koo, BonEan
    • Korean journal of aerospace and environmental medicine
    • /
    • v.30 no.3
    • /
    • pp.113-129
    • /
    • 2020
  • With the operation of the KC-330 MRTT (Multi Role Tanker Transport), which had been fielded in 2019, the ROKAF (Republic of Korea Air Force) has given fighter pilots a new mission of air refueling. As a result, fighter pilots are more likely to be exposed to risks they have never faced before, and it is necessary to look at the risk factors associated with human factors in air refueling missions. Therefore, in this study, an analysis using the HFACS (Human Factors Analysis and Classification System) model was performed for fighter pilots with air refueling qualifications. This study tried to prevent hazard in advance by discriminating the risk factors according to the human factors related to the fighter pilot during the air refueling mission.

Parametric Study of Shape Design for Strength Performance Enhancement of Bellows in Hydrogen Compressor-embedded Refueling Tank (수소 압축기 내장형 충전 탱크의 벨로우즈 강도 성능 향상을 위한 형상 설계 파라미터 연구)

  • Ji-Hyoung Kim;Chang-Yong Song
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.39-46
    • /
    • 2024
  • As the development of hydrogen vehicles has accelerated in recent years, it is necessary to develop a storage tank for hydrogen fueling stations capable of high-pressure charging, and for this purpose, a new system with a compressor-embedded refueling tank is required. In this study, the parametric study of shape design based on strength performance evaluation was carried out to find the optimal shape design of bellows, the core component of compressor-embedded refueling tank for a newly developed hydrogen refueling station capable of high-pressure charging above 1,000 bar. The design factors for parametric study were contour shape and radius of bellows, and the performance factors were the maximum stress and the gap distance in the contact direction. In the shape design of the compressor bellows for hydrogen refueling station considered in this study, it was found that adjusting the contour radius is an appropriate design method to improve the compression performance and structural safety.

A Study on Development of Mobile LNG Yard Tractor Refueling Standards (이동식 LNG 야드트랙터 충전 기준 개발 연구)

  • Ryou, Young-don;Yu, Chul-hee;Koo, Bon-deuk;Lee, Dong-won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.59-64
    • /
    • 2018
  • As part of measures to reduce fine dust, the government is promoting a project to convert the fuel of Yard Tractors(YT, tractors operated at ports), from diesel to LNG (Liquefied Natural Gas). While a port having a small number of yard tractors, it is not proper to construct a stationary LNG fueling station and supply LNG to YT due to a problem of BOG (Boil off gas) generation. Therefore, it is necessary to make a regulation and a standard on mobile LNG YT refueling station installation and inspection as an alternative. In this study, we have investigated domestic and foreign mobile LNG refueling cases and refueling standards, including the USA and Europe. In addition, we have suggested the risk reduction method according to the cause after investigation of the cause of LNG accidents. And last, based on the proposed risk reduction measures, we have proposed an amendment to the Regulation of the Urban Gas Business Law in Korea. The proposed mobile LNG YT refueling amendment of the Regulation includes ; maintenance of the safety distance from the protection facility, installation of an interlock device to prevent refueling in places other than the authorized place, installation of the identification system through biometrics, separation of the tank lorry and tow vehicle before refueling, checking the wheel fixed status of tank lorry before refueling, construction of the impounding area, safety measures before, during and after refueling, etc. The safety standards proposed in this study could be used as a reference in establishing standards for mobile LNG vehicle refueling in the near future.

Comparison of WiFi Protocols for Safety Communication Between Hydrogen Refueling Station and Fuel Cell Electric Vehicle (수소충전소와 수소전기차간의 안전통신을 위한 WiFi 프로토콜 비교)

  • Ha-Jin Hwang;Dong-Geon So;Do-Ho Cha;Hye-Jin Chae;Seo-Hee Jung;Sung-Ho Hwang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.81-87
    • /
    • 2023
  • SAE J2601 and SAE J2799, the communication protocols between a hydrogen refueling station and a fuel cell electric vehicle, only cover hydrogen charging. In this paper, we measure the hydrogen detection, current, and voltage of a fuel cell electric vehicle and transmit the sensor data to the hydrogen refueling station by changing the WiFi protocol. A small-scale laboratory model was built using Raspberry Pi for sensing, controlling, and transmitting sensor data of a fuel cell electric vehicle. The sensor data was stored in the database of the hydrogen refueling station, and a dashboard was configured using Grafana to analyze the stored data. When hydrogen is detected, the dispenser valve of the hydrogen refueling station is locked. Then, we measured the average transmission delay according to the WiFi protocol. The results showed that IEEE 802.11a is the most suitable WiFi protocol for transmitting sensor data between the hydrogen refueling station and the fuel cell electric vehicle.

Location of Refueling Stations for Geographically Based Alternative-Fuel Vehicle Demand (수요의 지역차를 고려한 대체연료 충전소 최적입지선정 : 플로리다 올랜도를 사례로)

  • Kim, Jong-Geun
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.95-115
    • /
    • 2012
  • The initial market of alternative-fuel vehicle (AFV) will show geographically uneven distribution due to AFV's high price, and thus efficient location model should consider spatial variation of demand. This paper estimates AFV trips by incorporating an AFV demand estimation model with origin-destination (OD) trips. The estimates are the input for the flow-refueling location model that maximizes the OD flows that can be refueled by the given number of stations considering AFV's limited range per refueling. A scenario analysis is conducted by varying assumptions in estimating demands and AFV acceptance rate. Optimal location alternatives for Orland metropolitan area are provided and results are compared.

  • PDF

Safety Analysis of Potential Hazards at Hydrogen Refueling Station (수소충전소 잠재적 위험에 대한 안전성해석)

  • Park, Woo-Il;Kim, Dong-Hwan;Kang, Seung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.43-48
    • /
    • 2021
  • This study was conducted using FLACS, a specialized gas accident analysis program. Hydrogen refueling stations subject of safety analysis, consist of compression facilities, storage tanks, and hydrogen piping. The safety analysis of potential risk factors was conducted after reflecting the design specifications of major facilities and components, environmental conditions around hydrogen refueling stations, etc. As of 2021, about 70 refueling stations in Korea are available, and 1,200 are scheduled to be introduced in the next 2040. To prepare for possible accidents caused by potential hazards for the safe distribution of hydrogen refueling stations, we intend to derive hydrogen leakage diffusion scenarios and review their safety.

A Study on the Achievement of Required Safety Integrity Level to Reduce Risk for SMR On-Site Hydrogen Refueling Stations (개질형 On-Site 수소충전소의 리스크 감소를 위해 요구되는 SIL 등급 달성 방안에 관한 연구)

  • Lee, Jin Ho;Lim, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.1-8
    • /
    • 2020
  • In recent years, hydrogen has received much attention as an alternative energy source to fossil fuels. In order to ensure safety from the increasing number of hydrogen refueling stations, prevention methods have been required. In this regard, this study suggested an approach to reduce the risk of hydrogen refueling station by increasing Safety Integrity Level (SIL) for a Steam Methane Reformer (SMR) in On-Site Hydrogen Refueling Station. The worst scenario in the SMR was selected by HAZOP and the required SIL for the worst scenario was identified by LOPA. To verify the required SIL, the PFDavg.(1/RRF) of Safety Instrumented System (SIS) in SMR was calculated by using realistic failure rate data of SIS. Next, several conditions were tested by varying the sensor redundancy and proof test interval reduction and their effects on risk reduction factor were investigated. Consequently, an improved condition, which were the redundancy of two-out-of-three and the proof test interval of twelve months, achieved the tolerable risk resulting in the magnitude of risk reduction factor ten times greater than that of the baseline condition.