• Title/Summary/Keyword: refraction

Search Result 734, Processing Time 0.033 seconds

Difference between Manifest Refraction (MR) and Cycloplegic Refraction (CR) with Age and Myopic Value (연령과 근시도에 따른 현성굴절검사와 조절마비굴절검사의 비교)

  • Jeong, Woo-Jae;Kang, Ji-Hun;Jeon, In-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.85-91
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate difference between manifest refraction (MR) and cycloplegic refraction (CR) with age and myopic value. Methods: Manifest and cycloplegic refractions were carried out on the patients of 229 myopic patients ($25.3{\pm}11.9$ years old). Results: The average results from a pre- and a postcycloplegic refraction showed a reduction of 0.19 D in myopia, 0.02 D in astigmatism and $1.85^{\circ}$ in astigmatism direction. Change of myopic value was higher in 30~40 age. Total 73 eyes of 229 patients who showed 0.50 diopter (D) in spherical, and a high degree of myopia group showed a higher discrepancy rate. Conclusions: The results found in the comparison of the value of the manifest refraction and cycloplegic refractions showed changes of myopic value was not significant with age of patient, but the group of high degree of myopia showed higher discrepancy rate.

Shallow Marine Seismic Refraction Data Acquisition and Interpretation Using digital Technique (디지털 技法을 이용한 淺海底 屈折法 彈性波 探査資料의 取得과 解析)

  • 이호영;김철민
    • 한국해양학회지
    • /
    • v.27 no.1
    • /
    • pp.19-34
    • /
    • 1992
  • Marine seismic refraction surveys have been carried out by Korea Institute of Geology, Mining and Materials(KIGAM) since 1984. The recording of refraction data was based on analog instrumentation. Therefore the resolution of refraction data was not good enough to distinguish many layers. The objective of the interpretation of seismic refraction data is the determination of intervals and critically refracted seismic wave propagation velocities through the layers beneath the sea floor. To determine intervals and velocities precisely, the resolution of refraction data should be enhanced. The intent of the study is to improve the quality of shallow marine refraction data by the digital technique using microcomputer- based acquisition and processing system. The system consists of an IBM AT microcomputer clone, an analog-digital(A/D) converter. A mass storage unit and a parallel processing board. The A/D converter has 12 bits of precision and 250 kHz of conversion rate. The magneto-optical disk drive is used for the mass storage of seismic refraction data. Shallow marine seismic refraction surveys have been carried out using the system at 6 locations off Ulsan and Pusan area. The refraction data were acquired by the radio sonobuoy. The refraction profiles have been produced by the laser printer with 300 dpi resolution after the basic computer processing. 5-9 layers were interpreted from digital refraction profiles, whereas 2-4 layers were interpreted from analog refraction profiles. the propagation velocities of sediments were interpreted as 1.6-2.1 km/sec. The propagation velocities of acoustic basement were interpreted as 2.4-2.7 km/sec off Ulsan area, 4.8 km/sec off Pusan area.

  • PDF

Analytical Method for Determining the Degree of Wave Refraction (파랑의 굴절 정도를 예측하는 해석기법)

  • Jung, Tae-Hwa;Lee, Changhoon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.5
    • /
    • pp.217-222
    • /
    • 2018
  • An analytical method for determining the degree of wave refraction is investigated. The ray tracing method previously used to calculate wave propagating cannot explain the degree of refraction caused by different kinds of conditions. In this study, we suggest the index of refraction degree using the principle that refraction is caused by the difference of phase velocities along the crest line.

Negative-refraction Effect for Both TE and TM Polarizations in Two-dimensional Annular Photonic Crystals

  • Wu, Hong;Li, Feng
    • Current Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • We systematically investigated the negative-refraction effect for both TE and TM polarizations in annular photonic crystals. Since two polarization waves are excited in different bands, they result in different refractive angles, and so polarization beam splitters can be made of annular photonic crystals. It was found that, in comparison to normal square-lattice air-hole photonic crystals, annular photonic crystals have a much wider common frequency band between TE-1 and TM-2, which is quite beneficial to finding the overlap between the negative-refraction regions belonging to TE-1 and TM-2 respectively. Further analyses of equifrequency surfaces and the electric-field distribution of annular photonic crystals with different parameters have not only demonstrated how the filling factor of annular cells affects the formation of the common negative-refraction region between TE-1 and TM-2, but also revealed some ways to improve the performance of a polarization beam splitter based on the negative-refraction effect in an annular photonic crystal.

Antisymmetric-Symmetric Mode Conversion of Ultrasonic Lamb Waves and Negative Refraction on Thin Steel Plate

  • Sung, Jin Woo;Kim, Young H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.3
    • /
    • pp.270-275
    • /
    • 2013
  • In this study, focusing of ultrasonic Lamb wave by negative refraction with mode conversion from antisymmetric to symmetric mode was investigated. When a wave propagates backward by negative refraction, the energy flux is antiparallel to the phase velocity. Backward propagation of Lamb wave is quite well known, but the behavior of backward Lamb wave at an interface has rarely been investigated. A pin-type transducer is used to detect Lamb wave propagating on a steel plate with a step change in thickness. Conversion from forward to backward propagating mode leads to negative refraction and thus wave focusing. By comparing the amplitudes of received Lamb waves at a specific frequency measured at different distance between transmitter and interface, the focusing of Lamb wave due to negative refraction was confirmed.

Study on the Night Myopia of Refraction (야간근시 굴절검사에 대한 연구)

  • Lee, Hark-Jun;Kim, Chang-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.107-112
    • /
    • 2008
  • urpose: This thesis is a study the Night myopia was surveyed by Subjective refraction and Objective refraction (Dark retinoscopy), and analyzed the relationship between them. It also looked at the relation between Night myopia and pupil size. Methods: 82 adult subjects (ages of 19 to 44, 44 males and 38 females) were examined by Subjective refraction and Objective refraction in the light place. Then Night myopia and pupil size were examined by Subjective refraction and Objective refraction in the dark again. The Statistics were analyzed by SPSS (Statistical Package for Social Science). Results: As the subjects became younger, the observed Night myopia was getting higher in both Subjective refraction, $x^2$=219.48 (p<0.01) and Objective refraction, $x^2$=241.98 (p<0.01). The relationship was statistically significant by showing large pupil size, $x^2$=151.74 (p<0.01). In Objective refraction, as pupil size became larger in the dark place, so did Night myopia, $x^2$=84.27 (p<0.01), reaching a statistically significant correlation, however, the correlation was low in Subjective refraction. In Subjective refraction, observed Night myopia was 73%, 64 examples of 88 examples, a standard of 0.96${\pm}$0.4584D in ${\pm}$0.25D, in male examples, and it was 64%, 49 examples of 76 examples, a standard of 1.01${\pm}$0.4509D in ${\pm}$0.25D, in female examples. In Objective refraction, it was 48%, 42 examples of 88 examples, in standard of 0.85${\pm}$0.4651D in ${\pm}$0.25D, in male examples. And it was 71%, 54 examples of 76 examples, in standard of 0.96${\pm}$0.4133D in ${\pm}$0.25D, in female examples. Conclusions: Night myopia which is measured by both methods, observed as $x^2$=265.35 (p<0.01) and showed a large relationship. The correlation between the two refractions suggests that observed night myopia diopter by Subjective refraction could be used as correction of night myopia.

  • PDF

Comparison between Manifest Refraction and Cycloplegic Refractin for the First-time Spectacle Wearers (최초 안경착용자의 현성굴절검사(MR)와 조절마비굴절검사(CR)의 비교)

  • Kim, Hye-Ran;Choi, Sun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.145-149
    • /
    • 2008
  • Purpose: To study the difference between refractive errors obtained from manifest refraction (MR) and cycloplegic refraction (CR) in first-time spectacle wearers. To study the difference between manifest refractive errors and cycloplegic refractive errors in first-time spectacle wearers. Methods: From January 2002 to December 2002, manifest and cycloplegic refractions were carried out on the patients who visited an ophthalmology clinic for a spectacle prescription for the first-time. The patients were 509 male and 499 female patients aged between from 3 to 15 years old. Results: The cycloplegic refraction showed a less myopia and a more hyperopia compared with the non-cycloplegic refraction. The differences were more in female patients. The CR showed a less myopic and a more hyperopic refractive errors than the MR. The differences were more in female patients. The average results from a pre- and a post-cycloplegic refraction showed a reduction of -0.22D in male, and -0.20D in female for the myopic group. For the myopic group, the myopic refractive errors by MR were -0.22D in male and -0.20D in female higher than the refractive errors by CR. Hyperopic group showed an increase of +0.37D in male, and +0.56D in female. For hyperopic group the hypropic refractive errors by CR were +0.37D in male and +0.56D in female higher than the refractive errors by CR. This difference between the results of a preand a post-cycloplegic refraction was more if the patients were younger. This difference between refractive errors by MR and by CR showed the younger the more and the proportions of pseudo-myopia and or latent hyperopia were also higher with younger patents age. The amounts of with-the-rule astigmatism and the oblique astigmatism were increased for the post-cycloplegic refraction in the CR refraction. Simple astigmatism reduced, but there was no difference found in the amount of astigmatism. The prevalence of simple astigmatism reduced, but there was no difference in the amount of astigmatism. Conclusions: The difference between manifest refraction and cycloplegic refraction was more in younger group. The difference of refrative error between by MR and CR increases with ageing decrease. Pseudo-myopia and latent hyperopia was also found in the younger group. Simple astigmatism reduced after cycloplegic refraction, there was no difference found in the amount of astigmatism. The prevalence of simple astigmatism reduced, but there was no difference in the amount of astigmatism.

  • PDF

ATMOSPHERIC REFRACTION EFFECTS ON LAMOST

  • SUN AIQUN;Hu JINGYAO
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.397-398
    • /
    • 1996
  • Large field spectrographs are severely influenced by atmospheric refraction. LAMOST is a large field multi-object spectroscopy telescope with $5^{\circ}$ field of view, f/5 focus ratio and 20m focal length. There will be 4000 fibers simultaneous on it's $\phi$1.75m focal plane. Here we discuss the atmospheric refraction effects on LAMOST in two hands. One is the effect of differential refraction across the field, another is the effect of atmospheric dispersion. According to the calculation, we find that: 1. The largest deviation from center within the field is 4.;32" during a 1.5-hour integration at $80^{\circ}$ declination. 2. The directions of deviation are complex, so the deviations can't be decreased by rotating the field. We also give out the atmospheric dispersions.

  • PDF

A Study on the Integrated Seismic Reflection and Refraction for Shallow Marine Site Survey KSEG.KGS Joint Symposium (천해저 조사를 위한 탄성파 반사법 및 굴절법 통합연구)

  • Kim, Chan-Su;Lee, Sang-Chul;Shin, Sung-Ryul;Kim, Hyun-Do;Jo, Chul-Hyun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.349-352
    • /
    • 2007
  • Estimating the physical properties of the survey area and mapping the geotechnical basement play an important role in ocean engineering and construction field. In this study, we performed marine seismic reflection and refraction survey as an engineering application at shallow marine. We made use of the dual boomer - single channel streamer as a source-receiver in reflection seismic survey and air-gun source - the manufactured OBC(Ocean Bottom Cable)-type streamer in refraction survey. In the seismic reflection data, we could easily find the geological layers and basement. Moreover, seismic refraction data could present sediment thickness and velocity distribution.

  • PDF

ATInSAR HOLOGRAM OBSERVATIONS OF COASTAL WAVE REFARCTION

  • Marghany, Maged
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.438-440
    • /
    • 2003
  • This study is introducing a new approach of ATInSAR hologram for modeling wave refraction spectra pattern. TOPSAR data with L$_{-HH}$ and C-vv bands utilized spatial variation of wave refraction. Based on the phase information in along track interferometry, and ATInSAR hologram the quantitative information such swell wave height and spectra energy have been modeled. The phase information in ATInSAR hologram images can be transferred to wave refraction The ATInSAR hologram can be used to investigate the wave refraction pattern along the coastal waters. The fringe information pattern was shown to be useful in modeling wave refaction spectra varaition. The hologram interferometry wave refraction model consists of two sub-models. The purpose of first sub-model is to determine the swell wave height by using ATInSAR. Second sub-model aims to generate the holographic interferometry from the information of two wave spectra which detected by ATInSAR technique. The azimuth cut-off variations along the fringe patterns will be estimated. As azimuth cut-off contains the wave height information which could be used the significant wave height variation in convergence and divergence zone.

  • PDF