Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor

  • Joo, Sungmoon;Lee, Jong Bok;Seo, Sang Mun
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.203-210
    • /
    • 2018
  • As the modernization of the nuclear instrumentation system progresses, research reactors have adopted digital wide-range neutron power measurement (DWRNPM) systems. These systems typically monitor the neutron flux across a range of over 10 decades. Because neutron detectors only measure the local neutron flux at their position, the local neutron flux must be converted to total reactor power through calibration, which involves mapping the local neutron flux level to a reference reactor power. Conventionally, the neutron power range is divided into smaller subranges because the neutron detector signal characteristics and the reference reactor power estimation methods are different for each subrange. Therefore, many factors should be considered when preparing the calibration procedure for DWRNPM channels. The main purpose of this work is to serve as a reference for performing the calibration of DWRNPM systems in research reactors. This work provides a comprehensive overview of the calibration of DWRNPM channels by describing the configuration of the DWRNPM system and by summarizing the theories of operation and the reference power estimation methods with their associated calibration procedure. The calibration procedure was actually performed during the commissioning of an open-pool type research reactor, and the results and experience are documented herein.

Standardization of Reference Values among Laboratories of Korean Association of Health Promotion-3rd Attempt (한국건강관리협회 임상병리검사결과 참고범위 설정 및 표준화 (3회차))

  • Lee, Gap-No;Yun, Jong-Hyeon;Jo, Han-Ik;Jeong, Hu-Geun;Park, Hyeon-Mo;Yun, Cheong-Ha;Kim, Sang-In
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Background : Since 2001 the Korean Association of Health Promotion has attempted to establish her own reference valves that can be used in her all fifteen branch laboratories instead of using those adapted from the published data or there commended data by the reagent companies supplied as inserts. However, the previous two reference values derived from the statistics(year 2001 and 2002) were need to adjust to apply to actual practice. Besides there was an unavoidable situation that the reagent has to be changed to other companies in 2002 that creates another statistical problem. Subsequently, the third attempt to derive the reference ranges of tests in KAHP to solve those problems and define common)v acceptable reference ranges was done and and reported here. Methods : Al1 the results performed during January 2, 2003 through September 30, 2003 were collected in Excel tile format. All the data include dthe necessary information such as age and sex. The age was grouped in six; baby(0-3y), children(4-l2y), adolescent(13-l8y), adult(19-S4y), younger elderly (65-79y),old elderly(oyer 80y), with references of statistics in medical informatics and WHO classification. The data were statistically analyzed with SAS 6.04 for-Gaussian distribution as the previous two occasions. None of the tests showed Gaussian distribution. These procedures had been repeated twice or three times after trimming out the results lying outside three standard deviations. Though, all the tests showed non-Gaussian distribution. Subsequently, the reference ranges were defined in the range from the point of lower 2.5% to the point of higher 97.5 %. And in case the lower range could be "0", the reference ranges were defined in the range of 0 to 95%.Results : The reference ranges of most of 56 test items were newly assigned. Also with adaptation of the recommendation of WHO etc. on fasting blood sugar, hemoglobin, cholesterol. Among these there were eight tests that needed reference ranges by the age groups and nine tests by the sex. Conclusions : The third attempt will credit more the reference range of all15 laboratories of Korean Association of Health Promotion, which will be essential part of the better service to the patient and clients to visit KAHP.

  • PDF

Design and Implementation Wake-up Module for Wireless Sensor Node using Dynamic Reference Voltage Demodulation Circuit (동적 기준전압 복조회로를 이용한 WBAN/USN 센서노드용 웨이크 업 모듈의 설계 및 구현)

  • Kim, Jong-Hong;Hwang, Ji-Hun;Park, Jun-Seok;Seong, Yeong-Rak;Oh, Ha-Ryoung
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.3
    • /
    • pp.152-156
    • /
    • 2009
  • This paper designs and implements wake up module for WBAN/USN sensor node which is using dynamic reference voltage demodulation circuit. When a comparator is used in a system for detecting received voltage level, comparator must have a reference voltage. However, the reference voltage is fixed, the system can communicate only a few range because received voltage level is changing widely due to distance of the wireless sensor nodes. Therefore, the proposed wake up module employs a dynamic reference voltage demodulation circuit for increasing communication range.

  • PDF

Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range (BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언)

  • Park, Hee-Won;Kim, Tae-Hoon;Roh, Gyeong-Un;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.108-114
    • /
    • 2012
  • Purpose: Immunosorbent assay most commonly used in the laboratory and commercial third-party quality control material is a substance that provided by BIO-RAD. However, in Reference Sheet by radioimmunoassay test kit or a measuring device for the mention of Acceptable Range is somewhat lacking. Radioimmunoassay for the inspection of test results by setting Acceptable Range to increase the objectivity of the recommendations on the data accumulated by the manufacturer listed in the Reference Sheet is to be issued. Materials and Methods : In our hospital since 2009 partially BIO-RAD using quality control materials in 2011, excluding certain items, some items were most of the BIO-RAD third-party quality control materials are used. Thus, internal quality control data accumulated BIO-RAD's Unity Real Time program by using the items were measured. Results : BIO-RAD using quality control material items were about 50 of the 20 Point Data averages, standard deviations, variation coefficients were calculated to measure the Acceptable Range of kit, automated immunoassay attributed Roche Elecsys / E170 / cobas e Systems the measures and compared. Conclusions : BIO-RAD QC materials commonly used hospital and peer group by setting the measurement kit, suitable for laboratory equipment for radioimmunoassay of Acceptable Range manufacturer recommendation to increase the objectivity of the test results by national and international recognition for radioimmunoassay should seek to increase.

  • PDF

A Speed Control of Sensorless Induction Motor using Direct Torque Control (직접 토오크 제어를 이용한 센스리스 유도전동기의 속도제어)

  • 박건우;고태언;하홍곤
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.181-185
    • /
    • 2001
  • This paper presents a digitally speed sensorless control system for induction motor with direct torque control (DTC). The drive is based on Mode1 Reference Adaptive System (MRAS) using state observer as a reference model fat flux estimation. The system are closed loop stator flux and torque observer for wide speed range that inputs are currents and voltages sensing of motor terminal, model reference adaptive control (MRAS) with rotor flux linkages for the speed turning aignal at low speed range, two hysteresis controllers. The Proposed system is verified through simulation.

  • PDF

A Study on the Evaluation of Fatigue Strength of Welded Lap Joint with Element Stress Approach (요소 응력을 이용한 겹침 용접부의 피로 강도 평가에 관한 연구)

  • Kim, Hyeon-Su;Shin, Sang-Beom;Kim, Myung-Hyun;Park, Dong-Hwan
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.61-65
    • /
    • 2014
  • The purpose of this study is to evaluate the applicability of the element stress to establish S-N design curve for the welded lap joint with thin plates below 2mm thickness. In order to do it, the extensive fatigue tests of the welded lap joints with INVAR alloy were performed. With the results, the deign S-N curves for the lap-weld were established by using the reference stresses such as the nominal stress range at the weld throat area, hot spot stress range and element stress range, and compared with regard to the standard deviation. The standard deviation of S-N curves with element stress range was less than that of S-N curves with other reference stresses. In addition, FEA results show the amount of the element stress is less sensitive to mesh size. Based on the results, it can be concluded that the element stress is to be used as the reference stress for the design S-N curves of the welded lap joint.

Radial Reference Map-Based Location Fingerprinting Technique

  • Cho, Kyoung-Woo;Chang, Eun-Young;Oh, Chang-Heon
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.4
    • /
    • pp.207-214
    • /
    • 2016
  • In this paper, we propose a radial reference map-based location fingerprinting technique with constant spacing from an access point (AP) to all reference points by considering the minimum dynamic range of the received signal strength indicator (RSSI) obtained through an experiment conducted in an indoor environment. Because the minimum dynamic range, 12 dBm, of the RSSI appeared every 20 cm during the training stage, a cell spacing of 80 cm was applied. Furthermore, by considering the minimum dynamic range of an RSSI in the location estimation stage, when an RSSI exceeding the cumulative average by ${\pm}6dBm$ was received, a previously estimated location was provided. We also compared the location estimation accuracy of the proposed method with that of a conventional fingerprinting technique that uses a grid reference map, and found that the average location estimation accuracy of the conventional method was 21.8%, whereas that of the proposed technique was 90.9%.

Removal of Search Point using Motion Vector Correlation and Distance between Reference Frames in H.264/AVC (움직임 벡터의 상관도와 참조 화면의 거리를 이용한 H.264/AVC 움직임 탐색 지점 제거)

  • Moon, Ji-Hee;Choi, Jung-Ah;Ho, Yo-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.2A
    • /
    • pp.113-118
    • /
    • 2012
  • In this paper, we propose the removal of search point using motion vector correlation and distance between reference frames in H.264/AVC. We remove the search points in full search method and predictive motion vectors in enhanced predictive zonal search method. Since the probability that the reference frame far from the current frame is selected as the best reference frame is decreased, we apply the weighted average based on distance between the current and reference frame to determine the fianl search range. In general, the size of search range is smaller than initial search range. We reduce motion estimation time using the final search range in full search method. Also, the refinement process is adaptively applied to each reference frame. The proposed methods reduce the computational throughput of full search method by 57.13% and of enhanced predictive zonal search by 14.71% without visible performance degradation.

Error Rate Analysis according to Setting of the Reference Point for Calculating the Flood Runoff that using Surface Image Velocimeter (SIV) (표면영상유속계(SIV)를 활용한 홍수유출량 산정 시 참조점 설정에 따른 오차율 분석)

  • Kim, Yong-Seok;Yang, Sung-Kee
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.799-815
    • /
    • 2016
  • In this study, according to the reference setting based on the runoff video of 9:00 where the highest water level of 3.94 m has been recorded during the runoff of Cheon-mi Stream in Jeju Island by the attack of Typhoon no. 16 Sanba on September $17^{th}$, 2012, the error rate of long-distance and short-distance velocimetry and real-distance change rate by input error have been calculated and the input range value of reference point by stream has been suggested. In the reference setting process, if a long-distance reference point input error occurs, the real-distance change rate of 0.35 m in the x-axis direction and 1.35 m in y-axis direction is incurred by the subtle input error of 2~11 pixels, and if a short-distance reference point input error occurs, the real-distance change rate of 0.02 m in the x-axis direction and 0.81 m in y-axis direction is incurred by the subtle input error of 1~11 pixels. According to the long-distance reference point setting variable, the velocity error rate showed the range of fluctuation of at least 14.36% to at most 76.06%, and when calculating flux, it showed a great range of fluctuation of at least 20.48% to at most 78.81%.

An Empirical Validation Study for Calibration Verification in TDM Test (검량보정 검증의 실험적 적합성에 대한 연구 -치료적 약물검사를 중심으로-)

  • Chang, Sang-Wu;Kim, Nam-Yong;Choi, Ho-Sung;Park, Yong-Won;Chu, Gyung-Bok;Yun, Keun-Young;Park, Byung-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The purpose of this study was to verify (i) a consistent calibration verification for the assessment of method linearity and (ii) calibration agreement with calibration settings. We validated calibration verification through method linearity with different lot number of individual calibrators that span the working range for 9 tests except salicylate with control sample in test. We evaluated that it covered broad analyte range to assay from near zero to the top of the measuring range with 5 or 6 points every three times for 10 analytes in TDM test. Target values were plotted on X-axis with assigned or observed values on the Y-axis. Working range were as follows. Calibration verification of the measuring range (maximum to minimum values) has been validated asetaminophen 0.1 to $304.6_{\mu}g/mL$, salicylate 0 to $1005_{\mu}g/mL$, valproic acid 3.2 to $154.19_{\mu}g/mL$, digoxin 0.17 to 5.65 ng/mL, vancomycine 1.3 to $80.51_{\mu}g/mL$, carbarmazepine 0.1 to $22.3_{\mu}g/mL$, phenytonin 0.6 to $40.21_{\mu}g/mL$, theophyline 0.2 to $40.21_{\mu}g/mL$, primidone 0 to $24.07_{\mu}g/mL$, phenobarbital 0.6 to $60.0_{\mu}g/mL$. Drawing a straight line through five or six points of these data showed good linearity. We are sure that it is important to assess the calibration verification of a test method to ascertain the lowest and highest test results that are reliable.

  • PDF