• Title/Summary/Keyword: reference line

Search Result 1,109, Processing Time 0.025 seconds

A Study for Shopping Customer's Location Tracking and Moving Line Analysis Using Reference Tag on based RFID (RFID기반의 Reference Tag를 이용한 쇼핑 고객 위치추적 및 동선분석에 관한 연구)

  • Lim, Sang-Min;Lee, Keun-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.151-157
    • /
    • 2009
  • This project would discuss how to improve the limit and enhance the accuracy and confidence and the improved algorithm path searching engine module shelter's interference limit on spot searching and analysing by using real time path finding technology and USB memo교 RF which is fused to a Tag(u-Card).

A study of the reference compensating current estimation for active power filter (능동전력필터의 기준보상전류 추정에 관한 연구)

  • Bae Chang-han;Han Mun-seub;Kim Yong-ki;Bang Hyo-jin
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1480-1485
    • /
    • 2004
  • In this paper, a real-time digital kalman filtering algorithm is used to obtain the reference estimation of the control current for shunt active power filter. This algorithm provides the best estimate of the fundamental and harmonic frequency components from the sampled values of the line current or voltage waveform. By adopting of the digital Kalman filtering algorithm, the structure of the control algorithm eliminates the need of a Phase locked loop(PLL) for the synchronization of the reference signal used in the compensation and it not sensitive to the distortion of the line voltage. The effectiveness of the algorithm is confirmed by the computer simulations.

  • PDF

Electricity forecasting model using specific time zone (특정 시간대 전력수요예측 시계열모형)

  • Shin, YiRe;Yoon, Sanghoo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.2
    • /
    • pp.275-284
    • /
    • 2016
  • Accurate electricity demand forecasts is essential in reducing energy spend and preventing imbalance of the power supply. In forcasting electricity demand, we considered double seasonal Holt-Winters model and TBATS model with sliding window. We selected a specific time zone as the reference line of daily electric demand because it is least likely to be influenced by external factors. The forecasting performance have been evaluated in terms of RMSE and MAPE criteria. We used the observations ranging January 4, 2009 to December 31 for testing data. For validation data, the records has been used between January 1, 2012 and December 29, 2012.

Constraint of Semi-elliptical Surface Cracks in T and L-joints (T-형 및 L-형 배관내 반타원 표면균열에서의 구속상태)

  • Lee, Hyeong-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1325-1333
    • /
    • 2001
  • Critical defects in pressure vessels and pipes are generally found in the form of a semi-elliptical surface crack, and the analysis of which is consequently an important problem in engineering fracture mechanics. Furthermore, in addition to the traditional single parameter K or J-integral, the second parameter like T-stress should be measured to quantify the constraint effect. In this work, the validity of the line-spring finite element is investigated by comparing line-spring J-T solutions to the reference 3D finite element J-T solutions. A full 3D-mesh generating program for semi-elliptical surface cracks is employed to provide such reference 3D solutions. Then some structural characteristics of the surface-cracked T and L-joints are studied by mixed mode line-spring finite element. Negative T-stresses observed in T and L-joints indicate the necessity of J-T two parameter approach for analyses of surface-cracked T and L-joints.

Estimation of Fault Location on a Transmission Line via Time-Frequency Domain Reflectometry (시간-주파수 반사파 계측 방법을 이용한 전송선로의 결함 위치 추정)

  • Choe TokSon;Kwak Ki-Seok;Yoon Tae Sung;Park Jin Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.521-530
    • /
    • 2005
  • In this paper, a new high resolution reflectometry scheme, time-frequency domain reflectometry(TFDR), isproposed to detect and estimate a fault in a transmission line. Traditional reflectometry methodologies have been achieved either in the time domain or in the frequency domain only. However, the TFDR can jump over the performance limits of the traditional reflectometry methodologies because the acquired signal is analyzed in time and frequency domain simultaneously. In the TFDR, the new reference signal and the novel TFDR algorithm are proposed for analyzing the acquired signal in the time-frequency domain. Because the reference signal of Gaussian envelop chirp signal is localized in the time and frequency domain simultaneously, it is suitable to the analysis in the time-frequency domain. In the proposed TFDR algorithm, the time-frequency distribution function and the normalized time-frequency cross correlation function are used to detect and estimate a fault in a transmission line. That algorithm is verified for real-world coaxial cables which are typical transmission line with different types of faults by the TFDR system composed of real instruments. The performance of the TFDR methodology is compared with that o( the commercial time domain reflectomeoy(TDR) experiments, so that concludes the TFDR methodology can detect and estimate the fault with smaller error than TDR methodology.

A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator (직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법)

  • Jang, Hoon;Lee, Woo-Cheol;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

THE AMOUNT OF SOFT TISSUE CHANGE TO HARD TISSUE MOVEMENT FOLLOWING LE FORT II OSTEOTOMY (Le Fort II 골절단술을 이용한 비중안모 개선 효과에 대한 임상적 연구;경조직 이동에 따른 연조직 변화율에 대한 연구)

  • Kim, Myung-Jin;Yi, An-Na
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.1
    • /
    • pp.63-69
    • /
    • 2000
  • Le fort II osteotomy is much useful technique to correct the midfacial hypoplasia including nasomaxillary complex especilly in patient with dish face appearance. Not in simple orthognathic surgery but in Le Fort II osteotomy, the standardization of prognostic value is essential in treatment planning to achieve satisfactory postoperative results. According to pervious reports, the ratio of soft tissue change to hard tissue movements varies as to different surgical methods and different facial regions. But there are few report about the ratio of soft tissue change to hard tissue movement following Le Fort II osteotomy. So we tried to develop standarized soft tissue surgical treatment objective. We have followed up 16 patients, who had received Le Fort II osteotomy by one operator from 1990 to 1996, one year postoperatively. In cephalometrics, we used Frankfort line as horizontal reference line, and vertical reference line as one drawn from Sella to horizontal line perpendicularly. The landmarks are G to soft tissue G, N on reference line to soft tissue N, ANS to Pn and A to Sn. The results are as follows. 1. The value of soft tissue change to hard tissue movement showed positive correlation, having statistical significancy at G, N2, N3 point. 2. At G, N2, N3 point, the ratio of soft tissue change to hard tissue movement was 0.51, 0.98 and 0.80 respectively and showed statistical significancy, while at N1, ANS, A point, that was 0.72, 0.49 and 0.26 but didn't showed statistical significance. 3. This result shows much the same change of the soft tissue change to hard tissue movement on the upper nasomaxilla, and less the same change on the lower maxilla and so the Le Fort II osteotomy can be recommended as a reliable effective operation method for correction of nasomaxillary retrusion.

  • PDF

Region Segmentation Algorithm of Object Using Self-Extraction of Reference Template (기준 템플릿의 자동 생성 기법을 이용한 물체 영역 분할 알고리즘)

  • Lee, Gyoon-Jung;Lee, Dong-Won;Joo, Jae-Heum;Bae, Jong-Gab;Nam, Ki-Gon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • In this paper, we propose the technique detecting interest object region effectively in the images from periscope of submarine based on self-generated template. First, we extract the sea-sky line, and divide it into sky and sea area from background region based on the sea-sky line. In each divided background region, the blocks which can be represented in each background region are set as a reference template. After dividing an image into several same size of blocks, we apply multi template matching to the divided search blocks and histogram template to divide the image into object region and background region. Proposed algorithm is adapted to various images in which objects exist in the background of sea and sky. We verified that proposed algorithm performed properly without given informmed prby prior learning.ropso, regardless of the slope of sea-sky line and the locmed p of object based on sea-sky line, we verified that the objects region was segmented effectively from the input image.

An Improved Guidance Algorithm for Smooth Transition at Way-Points in 3D Space for Autonomous Underwater Vehicles

  • Subramanian, Saravanakumar;Thondiyath, Asokan
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.139-150
    • /
    • 2012
  • This paper presents an improved guidance algorithm for autonomous underwater vehicles (AUV) in 3D space for generating smoother vehicle turn during the course change at the way-points. The way-point guidance by the line-of-sight (LOS) method has been modified for correcting the reference angles to achieve minimal calculation and smoother transition at the way-points. The algorithm has two phases in which the first phase brings the vehicle to converge to a distance threshold point on the line segment connecting the first two way-points and the next phase generates an angular path with smoother transition at the way-points. Then the desired angles are calculated from the reference and correction angles. The path points are regularly parameterized in the spherical coordinates and mapped to the Cartesian coordinates. The proposed algorithm is found to be simple and can be used for real time implementation. The details of the algorithm and simulation results are presented.

Precise Impedance Measurement of Coaxial Loads using Air Line Impedance Standards (Air Line 임피던스 표준을 이용한 동축형 부하의 임피던스 정밀 측정)

  • 강진섭;김정환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.788-795
    • /
    • 2000
  • In this paper, a method for the precise impedance measurement of coaxial loads using an offset open and short as the reflection standards and reference air lines with different lengths as the impedance standards is proposed. Measured input impedances of power sensors and thermistor mounts obtained from SWR bridges(5~400MHz) and a vector network analyzer(100~1,000MHz) are presented in the frequency range of 5MHz to 1,000 MHz.

  • PDF