• Title/Summary/Keyword: reference line

Search Result 1,111, Processing Time 0.029 seconds

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

Dose distribution at junctional area for head and neck radiotherapy (두경부 방사선치료시 접합 조사면의 선량분포)

  • 김정기;김기환;오영기;김진기;정동혁;신교철;양광모;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2001
  • For the head and neck radiotherapy, the technique of half beam using independent collimator is very useful to avoid overlapping of fields particularly when the lateral neck fields are placed adjacent to anterior supraclavicular field. Also abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom and the dose distribution at beam center of 2 half beams further examined according to depths(0 cm, 1.5 cm, 3 cm, 5 cm) for single anterior half beam and anterior/posterior half beam. The dose distribution to the junction line between photon and electron fields was also measured. For the single anterior half beam, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 88%, 93% and 95% of open beam, respectively. In the anterior/posterior half beams, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 92%, 93% and 95% of open beam, respectively At the junction line between photon and electron fields, hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. With above results, we concluded that when using electron beam or independent jaw for head and neck radiotherapy, the hot and cold dose area should be considered as critical point.

  • PDF

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

A study on the validity of reference points for edentulous patient (무치악 환자를 위한 참고점들의 효용성에 대한 연구)

  • Park, Jeong-Jae;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.310-317
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the validity of reference points for edentulous patient by examining the correlation of teeth and face, and intraoral anatomic landmarks. Materials and methods: We examined a facial outline, length, bizygomatic width, nasion - gnathion length, glabella - nasion distance in 270 men and 280 women satisfied with inclusion criteria from Seoul National School of Dentistry. The shape of maxillary central incisor, mesiodistal crown width and length of maxillary 6 incisors, distance from incisive papilla to labial surface of maxillary central incisor, and perpendicular distance from incisive papilla to intercanine line were measured in the stone model. We analyzed the ratio and relevant relation statistically. Results: The probability on having the same shape of face and the relative same shape maxillary incisor was 55.56% and 46.43% for men and women. The facial length proved to be a more valuable measurement in women in the tooth selection. The ratio of bizygomatic width to mesiodistal width of maxillary central incisor, and the ratio of bizygomatic width to width of maxillary 6 incisors were 16.8 : 1 and 3.0 : 1 and were positively correlated with each other. The distance of the canines from the maxillary incisal papilla was $1.33{\pm}1.28mm$. The distance between the center of the incisal papilla and the labial surface of their maxillary central incisor was $9.23{\pm}1.20mm$. Conclusion: It was showed that anatomical reference points in tooth selection and arrangement for edentulous patient are useful and have validity in our limited study.

Determination of Freely Dissolved PAHs in Seawater around the Korean Peninsula Using High Speed Rotation-Type Passive Sampling Device (고속회전식 수동형 채집 장치를 이용한 한반도 주변해역에서의 자유용존상 PAHs 측정)

  • JANG, YU LEE;LEE, HYO JIN;JEONG, HAEJIN;JEONG, DA YEONG;KIM, NA YEONG;KIM, GI BEUM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.1
    • /
    • pp.37-48
    • /
    • 2021
  • A new high speed rotation type-passive sampling device (HSR-PSD), which can rotate seawater at high speed and absorb easily and quickly the freely dissolved hydrophobic organic contaminants from seawater, was developed and then applied around the Korean Peninsula. Freely dissolved concentrations (Cfree) of polycyclic aromatic hydrocarbons (PAHs) were determined using the HSR-PSD with low density polyethylene (LDPE) sheets as a passive sampler. Furthermore, dissolved concentrations (Cdissolved) of PAHs in seawater were also obtained from high volume water sampling as a conventional method to account for actual bioavailability. When the LDPE sheets were rotated in the HSR-PSD at 900 rpm, PAHs with log KOW 3.4 ~ 5.2 were equilibrated between the LDPE and water in 5 hours. Although the high molecular weight PAHs with log KOW 5.6 ~ 6.8 was expected to be 2 to 30 days to reach the equilibrium, the Cfree of the PAHs at equilibrium could be corrected using performance reference compounds in 5 hours. Meanwhile, the total Cfree of PAHs were from 0.32 to 1.2 ng/L, which were higher than reported values in other oceans, but lower than in coastal water such as estuary, harbor, or shore. A bioavailability from the detected PAHs was highest at the sampling line near the dumping site of the Yellow Sea. Predicted residual concentrations in biota were relatively higher in offshore including the dumping site than in coastal regions.

A Study on the Reflective Property of Trends in Fashion Shows - Focused on Three Designing Factor of the Silhouette, the Detail, the Color and the Fashion Image - (패션쇼의 트렌드 반영성(反映性)에 관(關)한 연구(硏究) - 실루엣, 디테일, 색상(色相), 패션 이미지 등(等) 4가지 디자인 요소(要素)를 중심(中心)으로 -)

  • Lee, Myung-Hee
    • Journal of Fashion Business
    • /
    • v.3 no.4
    • /
    • pp.147-160
    • /
    • 1999
  • This paper is intended to compare and analyze the fashion trends that were introduced in the recent shows, held abroad and in Korea, so as to investigate how well the designers in Taegu and Kyungbuk (TK) area are keeping up with the international vogue. The research has done, analyzing Pret-a-Porter in Paris and the three events held in the TK area in 1997 -The Taegu Collection, Kyungbuk Fashion Festival and Textile & Apparel Fair and using reference pictures and documentary records. In order to investigate the trends the research is divided by four groups which are the silhouette, the detail, the color and the Fashion image and has done with the help of three postgraduate students. The results are as follows. 1. The Silhouette The slim-line has the greatest importance in the silhouette analysis of the recent collections. Like Elongated and Fit & Flare, tight-fitting and female-line were also appeared quite a lot. Compared with foreign collection, Korean collections put the bigger importance on the slim-line. 2. The Detail The printings, using paintings and plant-logos had the large portion of the accessories in both foreign and Korean collections. Draw string and wrap style were also presented a lot. Especially, at the Korean collections, layerd, corsage, and craft accent were emphasized, too. As for the necklines the similarity was found over the four events considering. Camisole neckline and halter neck were presented the most, and bared top, Vneckline, boat and low-neck which can highlight the feminity were often appeared as well. Considering collars, tailored and peaked collars which are frequently used for the jackets, were usually shown at the collections. Like convertable, shirts, wing and Italian collar, the collars that can be applied for the sports wears were presented a lot. Virtually no variation of design was found in the sleeve analysis. While set-in-sleeve and sleeveless were found commonly, not so many ornaments were added to the sleeves. The ankle and knee length for the pants and skirts were common. Furthermore, including the micro-mini, showing extremely feminine style the mini-style had the 20% portion of the skirt-length. Unbalanced lengths, using bias-cut were presented quite a lot on the runways. Deep slit skirts, wide pants and irregular hem skirts were in vogue. On the runways of Paris, more than 21% of the design was the burmuda pants. 3. The Color Red and Blue were in vogue in the four collections considering. Sometimes, yellowish was combined in Korean collections. Black and pale tone were appeared to be in fashion also with light grayish, moderate and deep tone. 4. The Fashion image As for the fashion image, feminine-decorative trend amounted to the large percentage in korean collections. At the foreign collection feminine-decorative trend and feminine trend were predominant, then mannish trend and simple trend were apeared equally. The research shows that TK area and foreign collections are fairy similar, which means that the designers in TK area have been making their efforts to satisfy the clients who have the international minds. However, compared with foreign collections, TK collections were apprered to be strongly inclined to only a few trends. Consequently the season trends are not as diverse as the foreign trends, which cannot satisfy the fashion taste of the clients in TK area. The local designers should know the tendency and the taste of the clients and make the more efforts to read local clients' mind.

  • PDF

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

Identification of a Locus Associated with Resistance to Phytophthora sojae in the Soybean Elite Line 'CheonAl' (콩 우수 계통 '천알'에서 발견한 역병 저항성 유전자좌)

  • Hee Jin You;Eun Ji Kang;In Jeong Kang;Ji-Min Kim;Sung-Taeg Kang;Sungwoo Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.3
    • /
    • pp.134-146
    • /
    • 2023
  • Phytophthora root rot (PRR) is a major soybean disease caused by an oomycete, Phytophthora sojae. PRR can be severe in poorly drained fields or wet soils. The disease management primarily relies on resistance genes called Rps (resistance to P. sojae). This study aimed to identify resistance loci associated with resistance to P. sojae isolate 40468 in Daepung × CheonAl recombinant inbred line (RIL) population. CheonAl is resistant to the isolate, while Daepung is generally susceptible. We genotyped the parents and RIL population via high-throughput single nucleotide polymorphism genotyping and constructed a set of genetic maps. The presence or absence of resistance to P. sojae was evaluated via hypocotyl inoculation technique, and phenotypic distribution fit to a ratio of 1:1 (R:S) (χ2 = 0.57, p = 0.75), indicating single gene mediated inheritance. Single-marker association and the linkage analysis identified a highly significant genomic region of 55.9~56.4 megabase pairs on chromosome 18 that explained ~98% of phenotypic variance. Many previous studies have reported several Rps genes in this region, and also it contains nine genes that are annotated to code leucine-rich repeat or serine/threonine kinase within the approximate 500 kilobase pairs interval based on the reference genome database. CheonAl is the first domestic soybean genotype characterized for resistance against P. sojae isolate 40468. Therefore, CheonAl could be a valuable genetic source for breeding resistance to P. sojae.

A Curricular Study on AI & ES in Library and Information Science (문헌정보학에서의 인공지능과 전문가시스템 교육과정 연구)

  • Koo Bon-Young;Park Mi-Young
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.32 no.2
    • /
    • pp.211-232
    • /
    • 1998
  • It is the purpose of this study to specify contents of Library and Information Science to train information professional to meet environment change of technology and system. Among them. recognizing necessity of present Artificial Intelligence and Export System (AI and ES) required by changing environment of latest Information technology, it is also the purpose of this work to figure out fundamental data and the way of solution how to introduce what contents out of AI and ES to Library and Information Science. The briefed results are as follows. 1. Due to rapid change of high Information technology and computer application it is the most important essential points, In order of Importance, in finding available network source, In indexing on-line data base, in analysing and design information system. and in computer application ability. 2. In contents of AI and ES, most Important training portion for Library and Information Science are : data base treating, thesaurus, natural language processing. and knowledge representation. 3. Library and information science professors recognize It necessary for bigger number of Library and Information Science students to be educated artificial intelligence and expert system. 4. During forthcoming age it shows more important reorganization that artificial intelligence and expert system improves information professional in reference service, cataloging, classification, information retrieval, and documentation delivery 5. According to library and information science professors more important reorganization on the subject of AI and ES, the curricular on AI and ES is, forthcoming, to be Introduced to curricular on library and information science in the nation, In order of importance, (see 1. above).

  • PDF