• 제목/요약/키워드: reference calibration

검색결과 460건 처리시간 0.026초

Efficiency calibration of a coaxial HPGe detector-Marinelli beaker geometry using an 152Eu source prepared in epoxy matrix and its validation by efficiency transfer method

  • Yucel, Haluk;Zumrut, Senem;Nartturk, Recep Bora;Gedik, Gizem
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.526-532
    • /
    • 2019
  • In this study, an in-house $^{152}Eu$ calibration source was produced from a custom epoxy matrix with a density of ${\rho}=1.14g\;cm^{-3}$, which is chemically stable and durable form after its solidification. The homogeneity of $^{152}Eu$ in matrix was obtained better than 98%. For a Marinelli beaker geometry, an efficiency calibration procedure was applied to a n-type, coaxial, 78.5% relative efficient HPGe detector in the energy range of 121.7-1408.0 keV by using in-house $^{152}Eu$ calibration source. Then the measured efficiencies for Marinelli geometry were compared with the results calculated by MEFFTRAN and ANGLE softwares for the validation. Although MEFFTRAN and ANGLE have two different efficiency transfer algorithms to calculate the efficiencies, they usually need to use a reliable and accurate reference efficiency values as input data. Hence, reference efficiency values were obtained experimentally from a multinuclide standard source for the same detector-Marinelli geometry. In the present source characterization, the corrections required for self-absorption and true coincidence summing effects for $^{152}Eu$ gamma-rays were also obtained for a such close counting geometry condition. The experimental results confirmed the validity of efficiency calculations obtained by MEFFTRAN and ANGLE softwares that are calculation tools.

한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교 (Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements)

  • 장시영;김봉환;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제21권4호
    • /
    • pp.255-262
    • /
    • 1996
  • 이 논문은 최근 한국원자력연구소(KAERI)와 미국 패시픽노스웨스트 국립연구소(일명, 바텔연구소, PNNL)이 개인선량계의 성능검사를 위한 미국 ANSI N13.11 기준에 근거하여 KAERI 방사선 측정/교정실험실에서 수행한 KAERI 기준 광자 및 베타 방사선장의 국제 상호비교 측정결과를 설명하고 있다. 두 기관이 각각 자국의 일차 표준에 소급성을 갖는 방사선 검출기와 방사선 측정장치를 사용하여 자유공기중에서 광자의 조사선량(율), 공기커마(율)와 베타선의 절대 흡수선량(율)을 측정한 결과, 광자선장에 대해서는 ${\pm}2.0%$을 베타선장에 대해서는${\pm}1.0%$의 오차범위 내에서 잘 일치하였다. 따라서 KAERI의 기준 광자 및 베타 방사선장은 국제표준에 잘 만족되고 있음이 입증되었으며 장차 방사선 도시메트리 연구개발의 국가 기술기반으로 활용될 수 있음이 확인되었다

  • PDF

그라비어 인쇄에서의 G7 Calibration 적용에 관한 연구 (A Study on the G7 Calibration Application in Gravure Printing)

  • 장영엽;오성상;조가람;이재수
    • 한국인쇄학회지
    • /
    • 제31권1호
    • /
    • pp.65-78
    • /
    • 2013
  • In gravure printing ink in printed flexible packaging considering the characteristics of the study more accurate color management options and results were as follows. When applying G7 calibration, P2P of the target GRACol G7 evaluate the delta $L^*$ and delta $F^*$, CMY and K-scale average of the results of delta $L^*$ and the highest tolerance G7 average of 1.5 and 3.0 are included in all the best. In addition, the average delta $F^*$ and super delta $F^*$, G7 tolerance by being included within the scope of color management, G7 calibration was possible. Target IT 8.7/4 CMYK, when applied to the calibration G7, Color gravure printing machine is applied to the average of the previous decreased from 12.4 to 3.6. In addition, if a digital proof is EPSON WT 7900 the average color applied to the previous reduction from 5.24 to 0.74 because of the gravure printing color proofing system was effective in the management. G7 calibration by applying the reference print profile of the Epson WT 7900-G-icc, the average was 0.74 coloration, and gravure-G-icc cases, the average color of the 3.60 per GRACol average of all the five colors below were included within the allowable range. Thus, the flexible packaging gravure printing color management of printed after applying the first G7 calibration, the results refer to the press by the profiling, and where best to take advantage of the profile creation was good.

Reynolds Number Effects on the Non-Nulling Calibration of a Cone-Type Five-Hole Probe for Turbomachinery Applications

  • Lee, Sang-Woo;Jun, Sang-Bae
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1632-1648
    • /
    • 2005
  • The effects of Reynolds number on the non-nulling calibration of a typical cone-type five-hole probe have been investigated for the representative Reynolds numbers in turbomachinery. The pitch and yaw angles are changed from - 35 degrees to 35 degrees with an angle interval of 5 degrees at six probe Reynolds numbers in range between $6.60{\times}10^3\;and\;3.17{\times}10^4$. The result shows that not only each calibration coefficient itself but also its Reynolds number dependency is affected significantly by the pitch and yaw angles. The Reynolds-number effects on the pitch- and yaw-angle coefficients are noticeable when the absolute values of the pitch and yaw angles are smaller than 20 degrees. The static-pressure coefficient is sensitive to the Reynolds number nearly all over the pitch- and yaw-angle range. The Reynolds-number effect on the total-pressure coefficient is found remarkable when the absolute values of the pitch and yaw angles are larger than 20 degrees. Through a typical non-nulling reduction procedure, actual reduced values of the pitch and yaw angles, static and total pressures, and velocity magnitude at each Reynolds number are obtained by employing the calibration coefficients at the highest Reynolds number ($Re=3.17{\times}10^4$) as input reference calibration data. As a result, it is found that each reduced value has its own unique trend depending on the pitch and yaw angles. Its general tendency is related closely to the variation of the corresponding calibration coefficient with the Reynolds number. Among the reduced values, the reduced total pressure suffers the most considerable deviation from the measured one and its dependency upon the pitch and yaw angles is most noticeable. In this study, the root-mean-square data as well as the upper and lower bounds of the reduced values are reported as a function of the Reynolds number. These data would be very useful in the estimation of the Reynolds-number effects on the non-nulling calibration.

Bayesian hypothesis testing for homogeneity of coecients of variation in k Normal populationsy

  • Kang, Sang-Gil
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권1호
    • /
    • pp.163-172
    • /
    • 2010
  • In this paper, we deal with the problem for testing homogeneity of coecients of variation in several normal distributions. We propose Bayesian hypothesis testing procedures based on the Bayes factor under noninformative prior. The noninformative prior is usually improper which yields a calibration problem that makes the Bayes factor to be dened up to a multiplicative constant. So we propose the objective Bayesian hypothesis testing procedures based on the fractional Bayes factor and the intrinsic Bayes factor under the reference prior. Simulation study and a real data example are provided.

Development of Reference Impulse Measuring Systems and Investigation on Comparison Tests in Japan

  • Harada, Tatsuya;Kashiwagi, Yasuhide
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 1991
  • The revised draft of IEC Publication 60 "High Voltage Test Techniques" introduced a new calibration system for impulse measurements. In order to corespond to this draft, development of reference measuring systems and investigation of comparison tests are being carried out in Japan. This paper is a preliminary report on the topic.

  • PDF

Quantitative Analysis of Chloride by Heteronuclear Electronic Reference NMR Method

  • Lee, Sueg-Geun
    • 한국자기공명학회논문지
    • /
    • 제11권2호
    • /
    • pp.115-121
    • /
    • 2007
  • A new quantitative analysis of chloride by the HERETIC NMR method which does not need internal or external references was described. The results showed that the use of HERETIC peak corresponding $500\;{\mu}g/mL$ of chloride calibration showed less than 4 % standard deviations from 50 to $5000\;{\mu}g/mL$ range of chloride concentrations.

  • PDF

Bayesian Model Selection in Weibull Populations

  • Kang, Sang-Gil
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권4호
    • /
    • pp.1123-1134
    • /
    • 2007
  • This article addresses the problem of testing whether the shape parameters in k independent Weibull populations are equal. We propose a Bayesian model selection procedure for equality of the shape parameters. The noninformative prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. So we propose the objective Bayesian model selection procedure based on the fractional Bayes factor and the intrinsic Bayes factor under the reference prior. Simulation study and a real example are provided.

  • PDF

접촉식 프로브의 오차교정 및 보정기술 (Calibration/Compensation of Errors of the Touch Probe)

  • 박희재;이교일
    • 대한기계학회논문집
    • /
    • 제18권8호
    • /
    • pp.2081-2087
    • /
    • 1994
  • Touch trigger probes are widely used for inspection purposed in the CMM(Coordinate meauring machine) or machine tool. The errors introduced by measurement probe are fairy systematic, thus can be calibrated and compensated properly. This paper presents a technique for the error calibration and compensation of the probe errors, which can be easily applicable to the manufacturers and users of the measurement probe. The probe coordinate system is defined for the probe error assessment, and a reference sphere ball is measured, and the probe errors are calibrated. The calibrated probe errors are represented in the 3D error map and 2D error map along probing direction. Detail algorithms for the error compensation are proposed.

천연가스 유량계 교정 시스템의 설계${\cdot}$구축 및 운영 (Design, Construction & Operation of Natural Gas Flowmeter Calibration System)

  • 이승준;이강진;정종태;하영철;안승희;이철구;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.389-393
    • /
    • 2001
  • Korea Gas Corporation(KOGAS) have constructed a gas flowmeters' calibration facilities at Jungdong Bucheon. The facilities consisting of 6 reference turbine meters can perform calibrations of large capacity natural gas flowmeters up to $9,600 m^3/h$ at 95 kPa. This large capacity and high pressure natural gas facilities is traceable to the national standard of gas flow rate (KRISS). In this article the motive of construction and description of design are summarized.

  • PDF