• Title/Summary/Keyword: reference calibration

Search Result 458, Processing Time 0.028 seconds

ESTIMATION OF SUGAR AND REDUCING SUGAR IN MOLASSES USING NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Mehrotra, Ranjana;Gupta, Alka;Tewari, Jagdish;Varma, S.P.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1258-1258
    • /
    • 2001
  • Estimation of sugar and reducing sugar content in molasses is very important task in sugar refineries. Conventional methods of determination of sugar content in molasses samples are highly time consuming and employ hazardous chemicals. Due to the physical properties of molasses, probability of error in conventional analytical techniques is high. These methods have proven to be inefficient for a process control in any sugar industry. Hence development of a rapid, inexpensive, physical and also accurate method for sugar determination in molasses will be highly useful. Near Infrared spectroscopy is being widely used worldwide as an analytical technique in food industry. The technique offers the advantage of being non-destructive and rapid. The present paper highlights the potential of near infrared reflectance spectroscopy as a rapid and automated analytical technique for determination of sugar and reducing sugar content in molasses. A number of molasses samples were collected during and after the sugar season from Havana Sugar Industry, Havana. The samples were chosen so as to obtain a wide range of concentration of sugar and reducing sugars. This was done in order to achieve a good calibration curve with widely spread data points. These samples were scanned in the region of 1100 - 2500 nm in diffuse reflectance mode. An indigenous ELICO NIR spectrophotometer, modified according to the requirements of sugar industry was used for this purpose. Each sample was also analyzed simultaneously by standard chemical methods. Chemical values were taken as reference for near infrared analysis. In order to obtain the most accurate calibration for the set of samples, various mathematical treatments were employed. Partial Least Square method was found to be most suitable for the analysis. A comparison is made between the actual values (chemical values) and the predicted values (NIR values). The actual values agree very well with the predicted values showing the accuracy of the technique. The validity of the technique is checked by predicting the concentration of sugar in unknown molasses samples using the calibration curve. The present investigation assesses the feasibility of the technique for on-line monitoring of sugars present in molasses in sugar industries.

  • PDF

Luminance Correction for Stereo Images using Histogram Interval Calibration (히스토그램 구간 교정을 이용한 스테레오 영상의 휘도 보정)

  • Kim, Seaho;Kim, Hiseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.159-167
    • /
    • 2013
  • In stereo-view system, variations of target camera position or lighting conditions cause discrepancies on the luminance and chrominance components of stereo views. These discrepancies lead to inaccurate frame view prediction and low quality of 3 D video coding. In this paper, an efficient histogram interval calibration method is proposed for stereo-view coding, so as to compensate for the luminance component of target view. First the proposed method is analyzed by the histogram of the target image frame. Then, it divide two sections of histogram of that frame to correct the color discrepancies. Secondly, each section of the target frame is corrected the luminance component by identify the maximum matching region between the reference frame and the target frame. We have verified our proposed histogram matching method in comparison with the other color correction ones. Experimental results show that it can correct better luminance calibration results of PSNR(Peak Signal to Noise Ratio) and has less computation time.

A Wide - Range Dual-Loop DLL with Programmable Skew - Calibration Circuitry for Post Package (패키지후 프로그램을 이용 스큐 수정이 가능한 광범위한 잠금 범위를 가지고 있는 이중 연산 DLL 회로)

  • Choi, Sung-Il;Moon, Gyu;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.408-420
    • /
    • 2003
  • This paper describes a Delay Locked Loop (DLL) circuit having two advancements : 1) a dual loop operation for a wide lock-range and 2) programmable replica delays using antifuse circuitry and internal voltage generator for a post-package skew calibration. The dual loop operation uses information from the initial time-difference between reference clock and internal clock to select one of the differential internal loops. This increases the lock-range of the DLL to the lower frequency. In addition, incorporation with the programmable replica delay using antifuse circuitry and internal voltage generator allows for the elimination of skews between external clock and internal clock that occur from on and off-chip variations after the package process. The proposed DLL, fabricated on 0.16m process, operates over the wide range of 42MHz - 400MHz with 2.3v power supply. The measured results show 43psec peak-to-peak jitter and 4.71psec ms jitter consuming 52㎽ at 400MHz.

Study on Calibration Methods of Discharge Coefficient of Sonic Nozzles using Constant Volume Flow Meter

  • Jeong, Wan-Seop;Sin, Jin-Hyeon;Gang, Sang-Baek;Park, Gyeong-Am;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.17-17
    • /
    • 2010
  • This paper address technical issues in calibrating discharge coefficients of sonic nozzles used to measure the volume flow rate of low vacuum dry pumps. The first challenging issue comes from the technical limit that their calibration results available from the flow measurement standard laboratories do not fully cover the low vacuum measurement range although the use of sonic nozzles for precision measurement of gas flow has been well established in NMIs. The second is to make an ultra low flow sonic nozzlesufficient to measure the throughput range of 0.01 mbar-l/s. Those small-sized sonic nozzles do not only achieve the noble stability and repeatability of gas flow but also minimize effects of the fluctuation of down stream pressures for the measurement of the volume flow rate of vacuum pumps. These distinctive properties of sonic nozzles are exploited to measure the pumping speed of low vacuum dry pumps widely used in the vacuum-related academic and industrial sectors. Sonic nozzles have been standard devices for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two small-sized sonic nozzles of diameter 0.03 mm and 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter (CVFM) readily set up in the Vacuum center of KRISS was used to calibrate the discharge coefficients of the machined nozzles. The calibration results were shown to determine them within the 3% measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process. Both calibrated sonic nozzles are demonstrated to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of low vacuum dry pumps in the semiconductor and flat display processes.

  • PDF

Quality Assessment of Beef Using Computer Vision Technology

  • Rahman, Md. Faizur;Iqbal, Abdullah;Hashem, Md. Abul;Adedeji, Akinbode A.
    • Food Science of Animal Resources
    • /
    • v.40 no.6
    • /
    • pp.896-907
    • /
    • 2020
  • Imaging technique or computer vision (CV) technology has received huge attention as a rapid and non-destructive technique throughout the world for measuring quality attributes of agricultural products including meat and meat products. This study was conducted to test the ability of CV technology to predict the quality attributes of beef. Images were captured from longissimus dorsi muscle in beef at 24 h post-mortem. Traits evaluated were color value (L*, a*, b*), pH, drip loss, cooking loss, dry matter, moisture, crude protein, fat, ash, thiobarbituric acid reactive substance (TBARS), peroxide value (POV), free fatty acid (FFA), total coliform count (TCC), total viable count (TVC) and total yeast-mould count (TYMC). Images were analyzed using the Matlab software (R2015a). Different reference values were determined by physicochemical, proximate, biochemical and microbiological test. All determination were done in triplicate and the mean value was reported. Data analysis was carried out using the programme Statgraphics Centurion XVI. Calibration and validation model were fitted using the software Unscrambler X version 9.7. A higher correlation found in a* (r=0.65) and moisture (r=0.56) with 'a*' value obtained from image analysis and the highest calibration and prediction accuracy was found in lightness (r2c=0.73, r2p=0.69) in beef. Results of this work show that CV technology may be a useful tool for predicting meat quality traits in the laboratory and meat processing industries.

A Study on the Analysis of Measurement Errors of Specific Gravity Meter (기준 밀도계의 측정 오차 분석에 관한 연구)

  • Lee, Kang-Jin;Her, Jae-Young;Ha, Young-Cheol;An, Seung-Hee;Lee, Seung-Jun;Lee, Cheol-Gu
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.676-680
    • /
    • 2002
  • The specific gravity meter is the instrument used to measure the density of fluids under the reference conditions and it can be widely used in industrial areas, especially in massive flow rate natural gas industry. This study has been carried out in an attempt to improve measurement accuracy of natural gas flow rate calculation, providing the adequate installation and proper operation conditions of specific gravity meter. The test results are 1) the density measurement errors in case of using methane and standard gas as calibration gases are smaller than using methane and nitrogen gas, 2) the periodical calibration to maintain accurate density measurements is essential, and 3) the specific gravity meter is sensitive to changes of environmental conditions, especially environmental temperature surrounding the specific gravity meter.

An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom

  • Pak, Minjung;Yoo, Jaeryong;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.274-281
    • /
    • 2016
  • Background: Whole-body counters are widely used to evaluate internal contamination of the internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic requirement that quality control procedures be applied to verify the reliability of the measured results. The implementation of intercomparison programs plays an important role in quality control, and the accuracy of the calibration and the reliability of the results should be verified through intercomparison. In this study, we evaluated the reliability of 2 whole-body counting systems using 2 calibration methods. Materials and Methods: In this study, 2 whole-body counters were calibrated using a reference male bottle manikin absorption (BOMAB) phantom and a Radiation Management Corporation (RMC-II) phantom. The reliability of the whole-body counting systems was evaluated by performing an intercomparison with International Atomic Energy Agencyto assess counting efficiency according to the type of the phantom. Results and Discussion: In the analysis of counting efficiency using the BOMAB phantom, the performance criteria of the counters were satisfied. The relative bias of activity for all radionuclides was -0.16 to 0.01 in the Fastscan and -0.01 to 0.03 in the Accuscan. However, when counting efficiency was analyzed using the RMC- II phantom, the relative bias of $^{241}Am$ activity was -0.49 in the Fastscan and 0.55 in the Accuscan, indicating that its performance criteria was not satisfactory. Conclusion: The intercomparison process demonstrated the reliability of whole-body counting systems calibrated with a BOMAB phantom. However, when the RMC-II phantom was used, the accuracy of measurements decreased for low-energy nuclides. Therefore, it appears that the RMC-II phantom should only be used for efficiency calibration for high-energy nuclides. Moreover, a novel phantom capable of matching the efficiency of the BOMAB phantom in low-energy nuclides should be developed.

A Study on X-Ray Fluorescence Analysis of Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ and ZrO$_2$ in Tin-slag Samples (희석 파라미터법에 의한 주석슬랙중 Ta$_2O_5,\;Nb_2O_5,\;SnO_2$ 및 ZrO$_2$의 X-선형광분석에 관한 연구)

  • Young Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.265-270
    • /
    • 1985
  • Ta$_2$O$_5$, Nb$_2$O$_5$, SnO$_2$ and ZrO$_2$ in tin-slag samples were determined by X-ray fluorescence spectrometry using the dilution parameter method and the analytical results were compared with the data obtained by standard calibration curve method. Tin-slag samples and one standard sample having very similar composition to the tin-slags were diluted with a proper diluent (La$_2$O$_3$) to the ratio of 1: 1, 1 : 2, 1 : 3 and 1 : 4. After measuring the X-ray intensities of original and diluted samples, the values of dilution parameters were calculated by using the dilution parameter equation. Without any calibration curve, the analytical results were calculated from the equation including the dilution parameter term. The results were in good agreement with the reference data by the standard calibration curve method.

  • PDF

Hydrographic Surveying in River by RTK GPS (RTK GPS에 의한 하천현황측량)

  • Lee, Suk-Bae;Choi, Bo-Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.3
    • /
    • pp.267-275
    • /
    • 2007
  • Nowadays, it grows bigger the importance of water resource management, and so, hydrographic surveying technology in river is important because it serves basic data about river environment. And, also, the application field of GPS has been increased and expected to be more increased because of the change of the geodetic reference system to World Geodetic System. In this study, hydrographic surveying in Hwang river in Geochang is accomplished by RTK GPS and Total Station and they are compared and analyzed the both results. The section profile in river is made by Hec-Ras program and CAD. The results show it can be saved 15.3% in surveying times and the amount of surveying works can be enlarged 42.5%. And the standard error between RTK results with calibration and the results without calibration turned out as 2.1 cm. So we have a conclusion that RTK GPS is more efficient surveying method than total station in hydrographic surveying in river.

Displacement Measurement of Structure using Multi-View Camera & Photogrammetry (사진측량법과 다시점 카메라를 이용한 구조물의 변위계측)

  • Yeo, Jeong-Hyeon;Yoon, In-Mo;Jeong, Young-Kee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1141-1144
    • /
    • 2005
  • In this paper, we propose an automatic displacement system for testing stability of structure. Photogrammetry is a method which can measure accurate 3D data from 2D images taken from different locations and which is suitable for analyzing and measuring the displacement of structure. This paper consists of camera calibration, feature extraction using coded target & retro-reflective circle, 3D reconstruction and analyzing accuracy. Multi-view camera which is used for measuring displacement of structure is placed with different location respectively. Camera calibration calculates trifocal tensor from corresponding points in images, from which Euclidean camera is calculated. Especially, in a step of feature extraction, we utilize sub-pixel method and pattern recognition in order to measure the accurate 3D locations. Scale bar is used as reference to measure. the accurate value of world coordinate..

  • PDF