• Title/Summary/Keyword: redundancy method

Search Result 559, Processing Time 0.025 seconds

Motion Compensation Based on Signal Processing Method for Airborne SAR

  • Song, Won-Gyu;Shin, Hee-Sub;Lee, Ho-Jin;Lim, Jong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1199-1201
    • /
    • 2005
  • In the synthetic aperture radar (SAR) system, the motion error is the main phase error sources and the motion compensation is very important. The phase gradient autofocus (PGA) is a state of art technique for phase error correction of SAR. It exploits the redundancy of the phase-error information among range bins by selecting the strongest scatter for each range bin and synthesizes them. The motivation of this paper is based on the observation that the redundancy of phase error is also among the cross-range direction. Moreover, the proposed method applies the weighting function to better utilize the phase error information. The validity of the proposed scheme for PGA is tested with some numerical simulation.

  • PDF

A Fault-Tolerant Control Strategy for Cascaded H-Bridge Multilevel Rectifiers

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Schanen, Jean-Luc;Khakbazan-Fard, Mahboubeh
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • Reliability is an important issue in cascaded H-bridge converters (CHB converters) because they use a high number of power semiconductors. A faulty power cell in a CHB converter can potentially lead to expensive downtime and great losses on the consumer side. With a fault-tolerant control strategy, operation can continue with the undamaged cells; thus increasing the reliability of the system. In this paper, the operating principles and the control method for a CHB multilevel rectifier are introduced. The influence of various faults on the CHB converter is investigated. The method of fault diagnosis and the bypassing of failed cells are explained. A fault-tolerant protection strategy is proposed to achieve redundancy in the CHB rectifier. The redundant H-bridge concept helps to deal with device failures and to increase system reliability. Simulation results verify the performance of the proposed strategy.

A Computer Aided Automatic Verification System for Mechanical Drawings Drawn with CAD System (CAD 시스템에 의하여 작성된 기계도면의 자동검증시스템에 관한 연구)

  • Lee, S.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.8
    • /
    • pp.60-71
    • /
    • 1996
  • Mostof existing CAD systems do not provide the advanced function for systematic checking of design and drafting errors in mechanical drawings. We have reported a computer aided drawing check system to single plane projection drawings made by a CAD system. This paper describes a checking method of dimensioning errors in mechanical drawings. The checking items are deficiency and redundancy of dimensions, input-errors in dimension figures and symbols, etc. Checking for deficiency and redundancy of global dimensions has been performed applying Graph Theory. This system has been applied to several examples and we have confirmed the feasibility of this checking method.

  • PDF

Bitrate Reduction by Interleaving DCT Coefficients for Differential Images (차이영상에 대한 DCT 계수의 끼워짜기를 이용한 비트율 감소)

  • 이상길;양경호;이충웅
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.7
    • /
    • pp.14-23
    • /
    • 1993
  • This paper proposes an algorithm to reduce the bitrate for transmission of MCP(motion compensated prediction) error signals. Many digital image coders have recently employed hybrid coding schemes which perform motion compensation, DCT transform, quantization, and variable length coding. The variable length coding compresses the quantized DCT coefficient data by removing their statistical redundancy. But some DCT blocks have the interblock statistical redundancy as well as the intrablock one. To utilize both of them, the DCT blocks are classified into the interleaving group and the non-interleaving group. And then each DCT blocks in the interleaving group are is encoded independently, and the DCT blocks in the interleaving group are encoded after interleaving the DCT coefficients. Through the simulations, it is shown that the proposed method outperforms the conventional method in which each DCT block is encoded independently.

  • PDF

Optimal Zero Vector Selecting Method to Reduce Switching Loss on Model Predictive Control of VSI (전압원 인버터의 모델 예측 제어에서 스위칭 손실을 줄이기 위한 최적의 제로 벡터 선택 방법)

  • Park, Jun-Cheol;Park, Chan-Bae;Baek, Jei-Hoon;Kwak, Sang-Shin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.273-279
    • /
    • 2015
  • A zero vector selection method to reduce switching losses for model predictive control (MPC) of voltage source inverter is proposed. A conventional MPC of voltage source inverter has not been proposed, and a method to select the redundancy of the zero vector is required for this study. In this paper, the redundancy of the zero vectors is selected with generating a zero sequence voltage to reduce switching losses. The zero vector of 2-level inverter is determined by determining sign of the zero sequence voltage. In the proposed method, the quality of the current is retained and switching loss can be reduced compared with the conventional method. This result was verified by P-sim simulation and experiments.

Fast Disparity Estimation Method Considering Temporal and Spatial Redundancy Based on a Dynamic Programming (시.공간 중복성을 고려한 다이내믹 프로그래밍 기반의 고속 변이 추정 기법)

  • Yun, Jung-Hwan;Bae, Byung-Kyu;Park, Se-Hwan;Song, Hyok;Kim, Dong-Wook;Yoo, Ji-Sang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10C
    • /
    • pp.787-797
    • /
    • 2008
  • In this paper, we propose a fast disparity estimation method considering temporal and spatial redundancy based on a dynamic programming for stereo matching. For the first step, the dynamic programming is performed to estimate disparity vectors with correlation between neighboring pixels in an image. Next, we efficiently compensate regions, which disparity vectors are not allocated, with neighboring disparity vectors assuming that disparity vectors in same object are quite similar. Moreover, in case of video sequence, we can decrease a complexity with temporal redundancy between neighboring frames. For performance comparison, we generate an intermediate-view image using the estimated disparity vector. Test results show that the proposed algorithm gives $0.8{\sim}2.4dB$-increased PSNR(peak signal to noise ratio) compared to a conventional block matching algorithm, and the proposed algorithm also gives approximately 0.1dB-increased PSNR and $48{\sim}68%$-lower complexity compared to the disparity estimation method based on general dynamic programming.

Fault-tree based reliability analysis for paralleled half-bridge sub-module of HVDC (HVDC 병렬 하프브리지 서브모듈에 대한 고장나무기반의 신뢰성 분석)

  • Kang, Feel-soon;Song, Sung-Geun
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1218-1223
    • /
    • 2019
  • In HVDC systems, the full-bridge submodule increases the number of components compared to the half-bridge submodule, but the failure-rate can be reduced by securing 100 % redundancy. However, full-bridge submodules require more complex control algorithms to ensure the redundancy and to prevent arm-short with sufficient dead-time. To solve this problem, we analyse the failure-rate of the paralleled half-bridge configuration with the same number of components and 100 % redundancy as the full-bridge submodule. The fault tree analysis (FTA) method is applied to the conventional part failure analysis to reflect the operation risk of the submodule, thereby predicting the life-cycle of the submodule more accurately. To verify the validity, the failure-rate results of the proposed FTA based analysis method are compared with the failure rate obtained by the part failure method.

Evaluation of Inferior Capsular Laxity in Patients with Atraumatic Multidirectional Shoulder Instability with Magnetic Resonance Arthrography

  • Kyoung-Jin Park;Ho-Seung Jeong;Ji-Kang Park;Jung-Kwon Cha;Sang-Woo Kang
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.931-938
    • /
    • 2019
  • Objective: To compare inferior capsular redundancy by using magnetic resonance arthrography (MRA) images in patients with multidirectional instability (MDI) of the shoulder and control subjects without instability and thereby develop a screening method to identify the presence of shoulder MDI. Materials and Methods: The MRA images of patients with MDI of the shoulder (n = 65, 57 men, 8 women; mean age, 24.5 years; age range, 18-42 years) treated over an eight-year period were retrospectively reviewed; a control group (n = 65, 57 men, 8 women; mean age, 27.4 years; age range, 18-45 years) without instability was also selected. The inferior capsular redundancy was measured using a new method we named the glenocapsular (GC) ratio method. MRA images of both groups were randomly mixed together, and two orthopedic surgeon reviewers measured the cross-sectional areas (CSAs) and sagittal capsule-head ratios on oblique sagittal images, as well as the axial capsule-head ratios on axial images and GC ratios on oblique coronal images. Results: The CSAs and GC ratios were significantly higher in patients than in controls (both, p < 0.001); however, the sagittal capsule-head ratios and axial capsule-head ratios were not significantly different (p = 0.317, p = 0.053, respectively). In addition, GC ratios determined the presence of MDI more sensitively and specifically than did CSAs. A GC ratio of > 1.42 was found to be most suggestive of MDI of the shoulder, owing to its high sensitivity (92.3%) and specificity (89.2%). Conclusion: GC ratio can be easily measured and used to accurately screen for MDI of the shoulder.

ATCS: An Adaptive TCP Coding Scheme for Satellite IP Networks

  • Dong, Wei;Wang, Junfeng;Huang, Minhuan;Tang, Jian;Zhou, Hongxia
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.5
    • /
    • pp.1013-1027
    • /
    • 2011
  • In this paper we propose ATCS, a practical TCP protocol coding scheme based on network coding for satellite IP networks. The proposal is specially designed to enhance TCP performance over satellite networks. In our scheme, the source introduces a degree of redundancy and transmits a random linear combination of TCP packets. Since the redundant packets are utilized to mask packet loss over satellite links, the degree of redundancy is determined by the link error rates. Through a simple and effective method, ATCS estimates link error rates in real time and then dynamically adjusts the redundant factor. Consequently, ATCS is adaptable to a wide range of link error rates by coding TCP segments with a flexible redundancy factor. Furthermore, the scheme is compatible with traditional TCP variants. Simulation results indicate that the proposal improves TCP performance considerably.

Content Analysis on Housing Design Guidelines for the Disabled in Korea (국내 장애인주택 디자인가이드라인 내용분석 연구)

  • Kim, Boae;Lee, Yeunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.1
    • /
    • pp.37-46
    • /
    • 2015
  • Purpose : With a recently growing population of the disabled, the importance of creating the living environment for them has been emphasized, making the design guidelines to play more important role in this sense. This research aims to generalize the existing design guidelines for the housing for the disabled, diagnose their problems, and suggest a systematic and consistent milestone of the guidelines developed in the future. Method : The analysis objects of this research are 1910 categories of the design guidelines for the domestic housing for the disabled, and the research removed the redundancy and separated multi-complex categories. A total of 1424 independent categories were extracted, and been conducted content analysis from three aspects of redundancy, sub-categorization system and descriptive form based on the extracted categories. Results : Redundancy analysis figured out important characteristics by space. Moreover, the current guideline system can be integrated by analysis of sub-category system. Lastly, the research found that the guidelines need to be understood more easily and suggested under accurate criteria by analyzing the descriptive forms. Implication : This research holds significance as a fundamental data to improve the design guidelines for the disabled in the future, ultimately contributing to a better quality of life of the disabled.