• 제목/요약/키워드: recovery temperature

검색결과 1,659건 처리시간 0.039초

발바닥 부위 쿨링이 심부 체온에 미치는 효과 (The Effect of Foot Cooling on Body Temperature)

  • 박유진;김정훈;박지은;김지인;이종민
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.232-236
    • /
    • 2017
  • In this study, We investigated the effect of foot cooling on the reduction of body temperature after hard exercise at the high temperature of $40^{\circ}C$. We performed a total of 30 subjects, and the subjects performed treadmill exercise for 30 minutes. We produced the cooling device to cool the foot using Peltier module. After the end of the exercise, We performed normal recovery method and cooling recovery method(one foot, both feet) for 1 hour on the same indoor environmental conditions and confirmed the change of body temperature of subjects. The results of deep body temperature measurement showed average $38.78{\pm}0.22^{\circ}C$ to $38.54{\pm}0.15^{\circ}C$ when the normal recovery method was performed. Cooling recovery method on one foot showed average $38.69{\pm}0.14^{\circ}C$ to average $38.06{\pm}0.17^{\circ}C$ and Cooling recovery method on both feet showed average $38.69{\pm}0.15^{\circ}C$ to average $37.84{\pm}0.21^{\circ}C$. There was a significant difference between the normal recovery method and the one foot cooling recovery method(p < .05), there was a significant difference between the normal recovery method and the both feet cooling recovery method(p < .05) and there was a significant difference between the one foot cooling recovery method and the both feet cooling recovery method(p < .05). Body temperature showed the lowest decrease rate when the normal recovery method was performed, and body temperature showed the highest decrease rate when the both feet cooling recovery method was performed. Therefore, recovery of cooling on the foot after hard exercise have decreased body temperature, delay fatigue in the body, and will be contributed to improvement of athlete performance.

채우기 밀도별 형상 기억 TPU 3D 프린팅 Re-entrant 스트립의 특성 분석 (Characterization of 3D Printed Re-entrant Strips Using Shape Memory Thermoplastic Polyurethane with Various Infill Density)

  • 정임주;이선희
    • 한국의류산업학회지
    • /
    • 제24권6호
    • /
    • pp.812-824
    • /
    • 2022
  • This study proposes to develop a 3D printed re-entrant(RE) strip by shape memory thermoplastic polyurethane that can be deformed and recovered by thermal stimulation. The most suitable 3D printing infill density condition and temperature condition during shape recovery for mechanical behavior were confirmed. As the poisson's ratio indicated, the higher the recovery temperature, the closer the poisson's ratio to zero and the better the auxetic properties. After recovery testing for five minutes, it appeared that the shape recovery ratio was the highest at 70℃. The temperature range when the shape recovery ratio appeared to be more than 90% was a recovery temperature of more than 50℃ and 60℃ when deformed under a constant load of 100 gf and 300 gf, respectively. This indicated that further deformation occurred after maximum recovery when recovered at a temperature of 80℃, which is above the glass transition temperature range. As for REstrip by infill density, a shape recovery properties of 100% was superior than 50%. Additionally, as the re-entrant structure exhibited a shape recovery ratio of more than 90%, and exhibited auxetic properties. It was confirmed that the infill density condition of 100% and the temperature condition of 70℃ are suitable for REstrips for applying the actuator.

Deep learning-based recovery method for missing structural temperature data using LSTM network

  • Liu, Hao;Ding, You-Liang;Zhao, Han-Wei;Wang, Man-Ya;Geng, Fang-Fang
    • Structural Monitoring and Maintenance
    • /
    • 제7권2호
    • /
    • pp.109-124
    • /
    • 2020
  • Benefiting from the massive monitoring data collected by the Structural health monitoring (SHM) system, scholars can grasp the complex environmental effects and structural state during structure operation. However, the monitoring data is often missing due to sensor faults and other reasons. It is necessary to study the recovery method of missing monitoring data. Taking the structural temperature monitoring data of Nanjing Dashengguan Yangtze River Bridge as an example, the long short-term memory (LSTM) network-based recovery method for missing structural temperature data is proposed in this paper. Firstly, the prediction results of temperature data using LSTM network, support vector machine (SVM), and wavelet neural network (WNN) are compared to verify the accuracy advantage of LSTM network in predicting time series data (such as structural temperature). Secondly, the application of LSTM network in the recovery of missing structural temperature data is discussed in detail. The results show that: the LSTM network can effectively recover the missing structural temperature data; incorporating more intact sensor data as input will further improve the recovery effect of missing data; selecting the sensor data which has a higher correlation coefficient with the data we want to recover as the input can achieve higher accuracy.

Pourbaix Diagram에 의거한 은(銀)의 회수반응(回收反應)에 미치는 온도영향(溫度影響) (The Influence of Temperature on the Recovery Reaction of Silver Based on the Pourbaix Diagram)

  • 원유라;김동수
    • 자원리싸이클링
    • /
    • 제21권6호
    • /
    • pp.74-81
    • /
    • 2012
  • 온도에 따른 Pourbaix Diagram 을 열역학 계산에 의해 구성하여 수용액 상 은의 회수반응에 미치는 온도의 영향을 파악하였다. 온도의 상승에 따라 물의 안정성은 pH 변화에 대해 더 크게 영향을 받으며 ${Ag^+}_{(aq)}$의 안정영역은 감소하는 것으로 나타났다. 온도가 하강함에 따라 $Ag_{(aq)}$$Ag_{(s)}$$Ag_2O_{3(s)}$ 형태로 회수하고 온도 상승 시에는 $Ag_{(aq)}$$Ag_2O_{(s)}$$Ag_2O_{2(s)}$의 형태로 회수하는 것이 화학반응상 보다 유리할 것으로 고찰되었다. $pH{\leq}2$ 이하의 강산성 영역에서는 온도 상승에 따른 은 회수 효율성이 감소하고 pH가 2 이상인 조건에서는 온도 증가에 따라 은의 회수 효율성이 증대될 것으로 파악되었다. 또한, 은을 원소 상태로 회수하는 방안은 산화은 형태로 회수하는 방안에 비해 온도변화에 대해 더욱 민감하게 영향을 받는 것으로 고려되었다.

물유동층 열교환기의 열회수성능 연구 (A Study on the Heat Recovery Performance of Water Fludized-Bed Heat Exchanger)

  • 김한덕;박상일;이세균
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.690-696
    • /
    • 2003
  • This paper presents the heat recovery performance of water fluidized-bed heat exchanger. Temperature and humidity ratio of waste gas are considered as important parameters in this study. Therefore, the heat recovery rate through water fluidized-bed heat exchanger for exhaust gases with various temperatures and humidity ratios can be estimated from the results of this study. Mass flow ratio (the ratio of mass flow rate of water to that of gas) and temperature of inlet water are also considered as important operating variables. Increase of heat recovery rate can be obtained through either high mass flow ratio or low temperature of inlet water with resultant low recovered temperature. The heat recovery performance with the mass flow ratio of about up to 10 has been investigated. The effect of number of stages of water fluidized-bed on the heat recovery performance has been also examined in this study.

Ni-Ti계 합금 선재의 변태온도 변화에 따른 인장변형 및 회복 특성 (Characteristics of Tensile Deformation and Shape Recovery with Transformation Temperature Change in a Ni-Ti Alloy Wire)

  • 최윤길;김미선;조우석;장우양
    • 열처리공학회지
    • /
    • 제21권6호
    • /
    • pp.307-313
    • /
    • 2008
  • The tensile deformation and shape recovery behaviors were studied in Ni-Ti shape memory wires showing different transformation characteristics by annealing at $200{\sim}600^{\circ}C$. Both R phase ${\rightarrow}$ B19' martensitic transformation at lower temperature and B2 ${\rightarrow}$ R phase transformation at higher temperature occurred in the shape memory wires annealed at $200{\sim}500^{\circ}C$. Transformation temperature and heat flow of B19' martensite increase but those of R phase main almost constant even with increasing annealing temperature. In the case of wires annealed and then cooled to $20^{\circ}C$, plateau on stress-strain curves in tensile testing can be observed due to the collapse of R phase variants and the formation of deformation-induced B19' martensite. In the case of wires annealed and then cooled to $-196^{\circ}C$, however, plateau on stress-strain curves does not appear and stress increases steadily with increasing tensile deformation. Comparing shape recovery rate with cooling temperature after annealing, shape recovery rate of the wire cooled to $20^{\circ}C$ is higher than that of the wire cooled to $-196^{\circ}C$ after annealing, and maximum shape recovery rate of 95% appears in the wire annealed at $400^{\circ}C$ and then cooled to $20^{\circ}C$. $R_s$ and $R_f$ temperatures measured during shape recovery tests are higher than $A_s$ and $A_f$ temperatures measured by DSC tests even at the same annealing temperature.

실험법에 의한 지능성 복합체의 회복응력 측정에 관한 연구 (A Study on the Measurement for the Recovery Stress of Intelligent Composite by Experiment)

  • 황재석;이효재
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.515-523
    • /
    • 2003
  • Shape memory is physical phenomenon which a platically metal is restored to its original shape by a solid state phase change by heating. TiNi alloy the most effective material in the shape memory alloy(SMA). To study(measure) recovery stress of intelligent composite. Ti50-Ni50 shape memory matrix with prestrain SMA fiber. When SMA fiber of the intelligent composite is heated over austenite starting temperature(As) by electric heating. a recovery stress are generated. The recovery stress of the intelligent composite was measured by strain gage or photoelastic experiment. Measuring method of recovery stress by photoelastic experiment was developed in this research. It was certified that photoelastic experiment was more effective and more precise than strain gage method in the measurement of recovery stress.

Ti-6Al-4V 합금의 단시간 고온 노출 시 모재 및 용접부의 인장강도 특성 (Effects on Tensile Strength of Base and Weld Metal of Ti-6Al-4V Alloy in Short Time Exposure to High Temperature)

  • 채병찬
    • 한국군사과학기술학회지
    • /
    • 제17권4호
    • /
    • pp.413-421
    • /
    • 2014
  • Since the structural temperature of a flight vehicle flying at high speed rises rapidly due to aerodynamic heating, it is necessary for optimum structural design to obtain proper material properties at high temperature by taking into account of its operational environment. For a special alloy, analysis data on strength change due to exposure time to high temperature are very limited, and most of them are for an exposure time longer than 30 minutes for long term operations. In this study, base and weld metal samples of Ti-6Al-4V alloy had been prepared and high temperature tensile tests with induction heating were performed, and then high temperature strength characteristics and strength recovery characteristics through cooling have been analyzed. Pre-tests to determine maximum heating rate were performed, and response characteristics for temperature control were confirmed. As a result, high temperature tensile strength appeared to be lower than that of room temperature, but it was higher than that of high temperature of 30 minite exposure listed in MMPDS. In strength recovery through cooling Ti-6Al-4V alloy has shown higher recovery rate compared with other alloys.

마이크로터빈의 열회수 성능시험 (Test of Heat Recovery Performance of a Microturbine)

  • 전무성;이종준;김동섭;장세동
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.629-635
    • /
    • 2008
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, the microturbine CHP (combined heat and power) system is relatively compact and easy to maintain. Generating hot water or steam is usual method of heat recovery from the microturbine. In this work, a heat recovery unit producing hot water was installed at the exhaust side of a 30 kW class microturbine and its performance characteristics following microturbine power variation was investigated. Heat recovery performance has been compared for different operating conditions such as constant hot water temperature and constant water flow rate. In particular, the influence of water flow rate and hot water temperature on the recovered heat was analyzed.

Hydrothermal liquefaction of Chlorella vulgaris: Effect of reaction temperature and time on energy recovery and nutrient recovery

  • Yang, Ji-Hyun;Shin, Hee-Yong;Ryu, Young-Jin;Lee, Choul-Gyun
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.267-273
    • /
    • 2018
  • Hydrothermal liquefaction of Chlorella vulgaris feedstock containing 80% (w/w) water was conducted in a batch reactor as a function of temperature (300, 325 and $350^{\circ}C$) and reaction times (5, 10 and 30 min). The biocrude yield, elemental composition and higher heating value obtained for various reaction conditions helped to predict the optimum conditions for maximizing energy recovery. To optimize the recovery of inorganic nutrients, we further investigated the effect of reaction conditions on the ammonium ($NH_4{^+}$), phosphate ($PO_4{^{3-}}$), nitrate ($NO_3{^-}$) and nitrite ($NO_2{^-}$) concentrations in the aqueous phase. A maximum energy recovery of 78% was obtained at $350^{\circ}C$ and 5 min, with a high energy density of 34.3 MJ/kg and lower contents of oxygen. For the recovery of inorganic nutrients, shorter reaction times achieved higher phosphorus recovery, with maximum recovery being 53% at $350^{\circ}C$ and 5 min. Our results indicate that the reaction condition of $350^{\circ}C$ for 5 min was optimal for maximizing energy recovery with improved quality, at the same time achieving a high phosphorus recovery.