• Title/Summary/Keyword: recovery cost

Search Result 608, Processing Time 0.025 seconds

Pressure Recovery in a supersonic ejector of a high altitude testing chamber (초음속 이젝터의 압력회복에 관한 연구)

  • Omollo, Owino George;Kong, Chang-Duk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.833-837
    • /
    • 2010
  • This study aims at finding an optimal exhaust diffuser design of a high altitude testing chamber for a low bypass turbofan engine (F404-402) with thrust pound force of 17,700 and air mass flow rate of 66kg/s ejecting at a speed of Mach 1.66. The final proposed ejector size has better pressure recovery characteristics and targets to reduce operational cost at engine performance testing. Conventional high altitude test chamber layout was adopted and first drawn in two dimensions using Autocad software so as to determine the gas path, the ejector frontal size was then determined from gas dynamics equations considering traditional gas ejection method where both the engine exhaust and cell cooling air are exhausted via the ejector. Modification to a smaller ejector with an alternative secondary cell cooling exhaust port was then performed and modelled in 3D using Solid Works software.

  • PDF

Review of Injection-Locked Oscillators

  • Choo, Min-Seong;Jeong, Deog-Kyoon
    • Journal of Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Handling precise timing in high-speed transceivers has always been a primary design target to achieve better performance. Many different approaches have been tried, and one of those is utilizing the beneficial nature of injection locking. Though the phenomenon was not intended for building integrated circuits at first, its coupling effect between neighboring oscillators has been utilized deliberately. Consequently, the dynamics of the injection-locked oscillator (ILO) have been explored, starting from R. Adler. As many aspects of the ILO were revealed, further studies followed to utilize the technique in practice, suggesting alternatives to the conventional frequency syntheses, which tend to be complicated and expensive. In this review, the historical analysis techniques from R. Adler are studied for better comprehension with proper notation of the variables, resulting in numerical results. In addition, how the timing jitter or phase noise in the ILO is attenuated from noise sources is presented in contrast to the clock generators based on the phase-locked loop (PLL). Although the ILO is very promising with higher cost effectiveness and better noise immunity than other schemes, unless correctly controlled or tuned, the promises above might not be realized. In order to present the favorable conditions, several strategies have been explored in diverse applications like frequency multiplication, data recovery, frequency division, clock distribution, etc. This paper reviews those research results for clock multiplication and data recovery in detail with their advantages and disadvantages they are referring to. Through this review, the readers will hopefully grasp the overall insight of the ILO, as well as its practical issues, in order to incorporate it on silicon successfully.

A Flyback Transformer linked Soft Switching PWM DC-DC Power Converter using Trapped Energy Recovery Passive Quasi-Resonant Snubbers with an Auxiliary Three-Winding Transformer

  • Ahmed Tarek;Chandhaket Srawouth;Nakaoka Mutsuo;Jung Song Hwa;Lee Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.237-245
    • /
    • 2004
  • In this paper, a two-switch high frequency flyback transformer linked zero voltage soft switching PWM DC-DC power converter implemented for distributed DC- feeding power conditioning supplies is proposed and discussed. This switch mode power converter circuit is mainly based on two main active power semiconductor switches and a main flyback high frequency transformer linked DC-DC converter in which, two passive lossless quasi-resonant snubbers with pulse current regeneration loops for energy recovery to the DC supply voltages composed of a three winding auxiliary high frequency pulse transformer, auxiliary capacitors and auxiliary diodes for inductive energy recovery discharge blocking due to snubber capacitors are introduced to achieve zero voltage soft switching from light to full load conditions. It is clarified that the passive resonant snubber-assisted soft switching PWM DC-DC power converter has some advantages such as simple circuit configuration, low cost, simple control scheme, high efficiency and lowered noises due to the soft switching commutation. Its operating principle is also described using each mode equivalent circuit. To determine the optimum resonant snubber circuit parameters, some practical design considerations are discussed and evaluated in this paper. Moreover, through experimentation the practical effectiveness of the proposed soft switching PWM DC-DC power converter using IGBTs is evaluated and compared with a hard switching PWM DC-DC power converter.

Increase of Recovery Ratio by Two Stage Membrane Process (the Pressurized PVDF Membrane Followed by Submerged PE Membrane) (PVDF 가압식과 PE 침지식 분리막을 결합한 2단 막여과 공정의 성능검토 및 회수율 증대 방안 연구)

  • Kim, Junhyeon;Mun, Baeksu;Jang, Hong-Jin;Kim, Jinho;Kim, Byungseok
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.45-53
    • /
    • 2013
  • Membrane filtration processes are increasingly popular for drinking water treatment that requires high quality of water. But pre-treatment system (Coagulation/Flocculation/Sedimentation) requires increased footprint and installation cost. In addition, 5~10% of the concentrate are formed. In this study, the pressurized PVDF membrane (ECONITY Co., Ltd.) system was tested with surface water (Han River, South Korea) without pre-treatment. As a result, permeate flux was operated between 1 m/d and 2.4 m/d (at $25^{\circ}C$) without chemical cleaning for one year and membrane permeate turbidity was maintained stably under 0.05 NTU regardless of raw water turbidity. And we studied application of concetrate treatment of pressurized PVDF membrane by submerged PE membrane (ECONITY Co., Ltd.). As a result, we increased recovery of total treatment process to 99.5%.

Recovery of Ammonia Nitrogen using Gas-permeable Membranes (기체투과막을 이용한 암모니아성 질소 회수방안)

  • Lee, Sang-hun;Chae, Sang Yeop
    • Membrane Journal
    • /
    • v.32 no.3
    • /
    • pp.191-197
    • /
    • 2022
  • Ammonia nitrogen can be effectively recovered from livestock manure waste, etc. by using the gas permeable membrane technology. In this case, ammonia gas in the waste passes through the pores in one-side of membrane, impregnated in waste, and then reach the opposite side of the membrane. The permeated ammonia gas molecules are captured and recovered by acid (such as sulfuric acid) in the solution existing on the opposite side of the membrane. In order to improve ammonia nitrogen removals in the inlet part, high pH should be maintained in the feed waste including ammonia nitrogen to recover, which requires the cost of the chemical. To resolve this issue, previous studies tested various methods, for example, utilization of cheap calcium hydroxide or aeration together with inhibition of unwanted nitrification. The gas permeable membranes used for the recovery of ammonia nitrogen may be characterized, not only by proper heat and chemical resistance, but also by hydrophobicity, allowing selective ammonia gas permeation through the hydrophobic membrane pores. Future research should consider the relevant pilot or upscale processes using on-site wastes with various properties, and identify the optimal design/operation conditions as well as economic feasibility improvement plans.

Utility Analysis for Pegfilgrastim in DLBCL Patients on R-CHOP Regimen (항암치료를 받는 미만성거대비세포 림프종 환자에서 페그필그라스팀에 대한 효용성 평가)

  • Jung, Hee Won;Kim, Jeong Mee;Min, Myung Sook;Lee, Young Mee;Bang, Joon Seok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.25 no.3
    • /
    • pp.151-158
    • /
    • 2015
  • Objective: This study was designed to compare pegfilgrastim and filgrastim in diffuse large B-cell lymphoma (DLBCL) patients treated with a rituximab with cyclophosphamide, hydroxydaunorubicin, oncovin, and prednisone (R-CHOP) regimen in terms of clinical efficacy and cost-effectiveness. Method: Clinical efficacy was measured by trough level of absolute neutrophil count (ANC), days of ANC under 50% of baseline value, days of ANC under 90% of baseline value, duration of ANC recovery to baseline value, days of ANC less than $0.5{\times}10^9cells/L$, and difference of peak and trough level of ANC during 1 cycle of R-CHOP regimen. To evaluate cost-effectiveness, total prices of used filgrastim and pegfilgrastim within 1 cycle of R-CHOP were analyzed. Results: In terms of clinical efficacy, trough level of ANC and days to ANC recovery showed statistical significance. The median trough levels of ANC with administration of filgrastim and pegfilgrastim were 0.18 and 1.94 (p = 0.021), respectively, and the median durations of ANC recovery to baseline value were 5.5 days and 2 days (p = 0.023), respectively. For the median days of ANC under 50% of baseline value, days of ANC under 90% of baseline value, days of ANC less than $0.5{\times}10^9cells/L$, and difference of peak and trough level of ANC during 1 cycle of R-CHOP, the pegfilgrastim group performed better than the filgrastim group. However the difference was not statistically significant. In terms of overall expense during 1 cycle of R-CHOP, pegfilgrastim is about 3.43 times more expensive than filgrastim. Conclusion: Pegfilgrastim is more efficient than filgrastim in terms of clinical efficacy. In terms of prices, pegfilgrastim is more expensive than filgrastim for patients, but it is more convenient in clinical use. Therefore, pegfilgrastim should be the preferred choice of G-CSF for neutropenic patients. Further comparative study of pegfilgrastim and filgrastim is needed.

A Mutant Arthrospira platensis M20CJK3 Showing Enhanced Growth Rate and Floatation Activity (생장 및 부상성이 향상된 남세균 돌연변이 균주 Arthrospira platensis M20CJK3)

  • Yoo, Chan;Kim, Choong-Jae;Choi, Gang-Guk;Ahn, Chi-Yong;Choi, Jong-Soon;Oh, Hee-Mock
    • Korean Journal of Microbiology
    • /
    • v.45 no.3
    • /
    • pp.268-274
    • /
    • 2009
  • A photosynthetic cyanobacterium Arthrospira platensis, well known for health food supplement, was studied as a target species for atmospheric $CO_2$ removal as well as biomass production. Although the biomass of A. platensis was massively produced in many countries, the recovery cost of its biomass is still high. The purpose of this study was to develop the A. platensis mutant strains which have enhanced growth rate and floatation activity to reduce the recovery cost. A. platensis KCTC AG20590 was treated with 0.24% ethyl methanesulfonate (EMS) for 20 min at room temperature. The mutant strain A. platensis M20CJK3 was finally selected by its morphological and physiological features. The morphology of the mutant A. platensis M20CJK3 was changed from loose-coiled form to tight-coiled form showing short pitch. The growth and $CO_2$ uptake rate of A. platensis M20CJK3 were improved about 15% and 17% compared with A. platensis KCTC AG20590, respectively. The floatation activity of A. platensis M20CJK3 was enhanced in 2-fold compared with that of A. platensis KCTC AG20590. Soluble proteins extracted from two strains were analyzed by two dimensional electrophoresis (2-DE) and MALDI-TOF MS/MS. Among 15 protein spots induced in 2-DE analysis, two spots were the proteins related to photosynthesis and electron transfer system of the other cyanobacteria. As a consequence, it seems that the tight-coiled mutant A. platensis M20CJK3 has an advantage of high growth rate and floatation activity which are beneficial for the mass cultivation and recovery.

Economic Analysis of Two-Layer Quiet Asphalt Pavement Considering Noise Cost Benefits (소음 편익 비용을 고려한 복층 저소음 아스팔트 포장의 경제성 분석)

  • Kang, Haet Vit;Park, Ki Sun;Kim, Nak Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1581-1587
    • /
    • 2014
  • Two-lalyered quiet asphalt pavements are well known for their noise reduction capabilities compared to the conventional ones. This study was conducted to analyze the economic effects on two-layered quiet asphalt pavement rather than on one-layered. Noise prediction was performed on the data surveyed from the two-layered quiet asphalt pavement. In addition, the economic analysis was executed considering cost benefits using the noise prediction result. The permeability test was also investigated to evaluate the clogging recovery of two-layered quiet asphalt pavement. Analysis results revealed that the construction cost of two-layered quiet asphalt pavements was cheaper than that of the conventional soundproof walls. The two-layered quiet asphalt pavement with simulated clogging conditions was satisfied the permeability requirements of the permeable asphalt pavements. The permeability test results showed that the permeable time was recorded as 6.77 seconds for one cycle of cleaning job with 400 mL of water.

Distribution Characteristics and Cost Estimation of Collection and Treatment of Deposited Marine Debris in Coastal Fisheries around the Southwestern Islands of Korea (서남해 주요 도서 연안 어장 침적쓰레기의 분포 실태 조사 및 수거 처리 비용 추정)

  • Kim, Seondong;Kang, Wonsoo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.4
    • /
    • pp.330-336
    • /
    • 2012
  • We surveyed and evaluated quantities and distribution characteristics of debris on the sea floor around active fishing grounds around the islands in the southwest coast of Korea in 2007 where the average depth is below 40m. Proper recovery gears mainly to haul the derelict fishing gears are selected considering the sea bed types of the areas. The collected debris amounts were used to estimate the total amount of the surveyed area. The number of hauls per trial times the amount of the debris was extended to whole sampling area and the weighting factor from the opinion was applied to reach the total amount of marine debris on the floor. The amount of the deposited marine debris around Wangdeung-do area is estimated as about 686 $kg/km^2$, and the cost of the collection and treatment for the deposited marine debris is estimated about 3.9 billion KRW after consideration of the proper size of the working ships, labor, transport and treatment cost.

Evaluation Method for Value Analysis in the Remodelling of Apartment Building - Focused on Economical Efficiency and User Demand - (건축물의 리모델링 가치분석을 위한 평가방법 - 경제성 평가와 사용자 요구분석을 중심으로 -)

  • Jeong, Dong-Whan;So, Kwang-Ho;Kim, Chun-Hag;Kim, Eui-Sik;Yang, Keek-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.4
    • /
    • pp.123-129
    • /
    • 2002
  • This research is aiming to specify the requirement of the investment such as initial cost, running cost earning rate to make effective investment considering the purpose of remodeling and economical value of store building enough to meet the initial purpose of remodeling. The review of earning rate for economical evaluation was performed by the on-site auditing on the structure and function of the building and applying the assessment simulation program, which is to find the possible business model to identify the requirement of building owner through case study. After the research, the following results are obtained. First, it is important that many aspects should be carefully analysis and the best method should be selected as characteristics of remodeling can tie defer each other in their implementations. Second, though the remodeling of exist buildings to promote the functions has been applied. no suitable assessment tool has bee developed for deriding the level of remodeling in the view of economical efficiency so far. Third, the economical benefit was evaluated by analysing annual earning rate which is applied by investment items and recovery period for the investment. More specific data base should be established to apply the suggested economic accession in business enough to forecast the future circumstances. More researches should be promoted on this area continuously as well as the integrated economic evaluation of remodeling on existing building.