• 제목/요약/키워드: recloser

검색결과 60건 처리시간 0.024초

지중배전선로의 고장전류 크기 및 보호협조분석 (Ananalzing fault current and Protective coordination in the underground line)

  • 조남훈;하복남;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

퍼지 논리 적용에 의한 배전계통의 고장 검출 시스템 개발 (Development of a Fuzzy Logic-based Fault Identification System In Distribution System)

  • 김창종;오용택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.737-739
    • /
    • 1996
  • Abnormal conditions and disturbances in distribution system cause an immediate influence to the customers. Conventional detection schemes for the distribution abnormalities have been applied in limited extents mainly because of their low reliability. In this paper, we developed a disturbance identification system which monitors the load level after a transient, checks the harmonic behavior of the load, and finally makes decision on the cause of the disturbance. This system identifies and discriminates overcurrent faults, arcing ground faults, recloser activities, and foreign object or tree contacts. In the implementation of the identification system, we applied fuzzy logic to better represent some variables whose Quantities are expressed only in non-numerical terms.

  • PDF

국산 배전자동화시스템 구성설비의 보유기능 및 특성 (The Functions and Characteristics of Distribution Automation System Components)

  • 하복남;박상만;장정태;최태일;김호용;오상기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF

태양광전원이 연계된 배전계통 보호협조기기의 부동작패턴 탐색알고리즘에 관한 연구 (A Study on Searching Algorithm for Malfunction Pattern of Protection Devices in Distribution System with PV Systems)

  • 권순환;태동현;이후동;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.652-661
    • /
    • 2020
  • 최근, 기후변화와 미세먼지 등에 의한 지구규모적인 환경문제를 해결하기 위하여, 정부에서는 RE 3020 정책을 시행하고 있으며, 이에 따라 대용량의 태양광전원이 배전계통에 연계되고 있다. 하지만, 대용량 태양광전원이 배전계통에 연계되는 경우, 태양광전원의 연계위치와 용량, 연계방식 및 고장지점에 따라 사고전류의 크기와 방향이 변하게 되고, 지락사고가 발생하여도 분류효과에 의하여 보호협조기기가 동작하지 않는 부동작 현상이 발생할 가능성이 있다. 따라서, 본 논문에서는 다수의 태양광전원이 배전계통에 연계되어 운용되는 경우, 리클로저(recloser, 이하 R/C)의 설치개소에 따라 보호협조기기가 동작하지 않는 부동작 메커니즘을 제시하고, 이를 바탕으로 다양한 시나리오에 기반한 보호협조기기의 부동작 패턴탐색 알고리즘을 제안한다. 또한, 보호협조 전용 해석 프로그램인 Off-DAS를 이용하여, 다수의 태양광 전원이 연계된 배전계통 모델링을 수행하고, 이를 바탕으로 다양한 시나리오에 따른 보호협조기기 부동작 패턴을 분석한다. 제안한 보호협조기기의 부동작패턴 탐색알고리즘 및 모델링을 바탕으로 시뮬레이션을 수행한 결과, R/C의 설치개소 및 태양광전원의 연계 패턴에 따라 부동작 현상이 발생함을 알 수 있어, 본 논문의 유용성을 확인하였다.

리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘 (A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser)

  • 김슬기;김응상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.

배전계통에 연계된 열병합발전 시스템의 개선된 보호협조 방안에 관한 연구 (Advanced Protective Coordination Schemes of Utility Interconnected Cogeneration Systems)

  • 최준호;정성교;추동욱;김낙경;손학식;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.280-288
    • /
    • 2000
  • Recently, there has been growing interest in utilizing cogeneration(COGN) systems with a high-energy efficiency due to the increasing energy consumption and the lacking of energy resource. But an insertion of COGN system to existing power distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power of COGN, especially in protective coordination. A study on a proper coordination with existing one is being required. The existing power distribution system is operated with radial type by one source and protection system is composed based on unidirectional power source. But an Insertion of COGN system to power distribution system change existing unidirectional power source system to bidirectional power source. Therefore, investigation to cover whole field of power distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. In this paper, simulation using PSCAD/EMTDC was accomplished to analyze effect of COGIN on distribution fault current. Also, the existing protection system of 22.9[kV] power distribution system and customers protection system to protect of COGIN was analyzed and the study on protective coordination between of two protection system accomplished.

  • PDF

분산전원 연계 배전계통의 보호협조 정정 프로그램 개발 (A Simulation Program for Protection Coordination in the Power Distribution System with Distributed Generators)

  • 김상옥;서인용;이흥호;노대석
    • 한국시뮬레이션학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-8
    • /
    • 2013
  • 신재생에너지원의 확대 보급 정책과 신재생에너지 공급 의무화 제도(RPS)의 도입으로 배전계통에 연계되는 분산전원이 증가되고 있다. 분산전원이 연계된 배전계통에서는 고장전류의 크기와 방향이 변화하게 되며, 이러한 고장전류의 변화는 기존 보호협조 체계에 대한 재검토를 요구한다. 전력연구원에서는 이러한 고장전류의 변화를 고려할 수 있는 보호협조 정정 알고리즘을 탑재한 시뮬레이션 프로그램을 개발하였다. 본 논문에서는 분산전원 연계 전, 후의 고장전류 변화를 분석하고, 시뮬레이션 프로그램을 이용하여 샘플 계통에 대한 보호협조 정정을 수행하였으며, 분산전원이 배전계통의 보호협조에 미치는 영향에 대하여 고찰하고 그 대책에 대하여 논하고자 한다.

배전계통에서 변압기 결선에 의한 역 조류현상에 관한 연구 (A Study on the Reverse-Power-Flow Phenomenon due to Transformer Wiring Types in Distribution System)

  • 신동열;하복남;정원욱;차한주
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.111-119
    • /
    • 2008
  • 본 논문에서는 최근 분산전원 확대보급에 따라 계량오차 발생, 변전소 CB 또는 Recloser, 수전설비 VCB의 OCGR 오동작, 배전자동화 시스템 거짓FI 정보발생 등 한전 배전계통에서 발생되는 오동작 현상에 대해서 원인분석을 수행하였고 그 원인은 변압기 결선에 의한 역 조류현상임을 규명하였다. 이러한 역 조류현상의 영향으로 배전계통의 3상 기본파 전류가 N상에서 동상이 되어 3배의 전류로 합산되었으며, 이 현상을 근거로 새로운 계통해석 방법을 제시하였다. 새로운 계통해석 방법을 적용하여 구간별 고장전류를 해석하였고, 역 조류현상 규명을 위해 변압기 결선형태 별로 역 조류 발생여부를 실험하였다. 또한 PSCAD/EMTDC로 실제 계통을 모의함으로써 역 조류에 의한 오동작 현상을 줄이기 위한 방법으로 중성선의 영상임피던스를 조절하는 방법을 제시하였다.

배전선로 재폐로 최적 기준 산정에 관한 연구 (A Study on Determination of Optimal Reclosing Guideline on Distribution Lines)

  • 조재훈;이선정;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.417-422
    • /
    • 2022
  • 선로를 따라 흐르는 전력흐름은 장기간에 걸쳐서 차단되지 않는 연속성을 갖는 것이 바람직하다. 배전선로에서 재폐로기의 최적 기준은 전력계통의 신뢰성을 개선하는 것으로 알려져 있으며, 배전계통에서 보호기능은 이러한 재폐로기의 수량과 위치가 매우 중요하다. 본 연구에서는 배전망 사고 동안 발생되는 손실을 줄이기 위하여 재폐로 동작 횟수를 포함한 보호기법의 사용 효과를 검토한다. 본 연구의 최종 목적은 표준 배전망에 대한 PSCAD/EMTDC의 모의데이터를 기반으로 사고전류 조건과 재폐로 동작 횟수를 결정하는 것이다. 피더의 보호기능인 재폐로기에서 동작횟수 결정은 배전망의 최적 운영과 신뢰성 확보에 도움이 된다.

대용량 태양광전원이 연계된 배전선로에 있어서 보호협조기기의 최적 운용알고리즘 (Optimal Operation Algorithm of Protection Devices in Distribution Systems With PV System)

  • 권순환;이후동;남양현;노대석
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.17-26
    • /
    • 2018
  • 최근, 대용량의 태양광전원이 연계된 배전계통은 기존의 단방향과 달리 양방향의 조류가 발생하고, 태양광전원의 연계위치 및 고장위치에 따라 사고전류의 크기와 방향이 변하여, 보호기기간의 협조시간차가 충분히 확보되지 않는 문제점이 발생할 수 있다. 또한, 태양광전원을 고려하지 않은 기존의 보호기기 정정치를 그대로 적용하고 있어 보호기기간의 협조시간차를 확보하기 어려운 상황이 발생하고 있다. 따라서 본 논문에서는 태양광전원이 연계된 선로에서 고려할 수 있는 3가지 Case의 보호기기 정정치 운용모드를 제시하고, 이를 바탕으로 태양광전원의 용량에 따른 최적의 보호협조 시간을 도출할 수 있는 알고리즘을 제안한다. 한편, 이를 바탕으로 보호협조 전용소프트웨어인 Off-DAS를 이용하여, 태양광전원이 연계된 배전계통을 모델링하고, 보호기기(변전소 계전기, 리클로저(Recloser), 고객계전기, 태양광전원 고객계전기)간의 협조시간차 특성을 분석한다. 실 계통을 대상으로 시뮬레이션을 수행한 결과, 본 논문에서 제시한 보호기기의 정정치 운용 모드와 정정치 산정 방식이 태양광 전원이 연계된 배전계통 보호기기간의 협조시간을 안정적으로 확보할 수 있음을 알 수 있었다.