• 제목/요약/키워드: real-time measurements

검색결과 652건 처리시간 0.025초

프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발 (Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique)

  • ;이건수;박강
    • 한국CDE학회논문집
    • /
    • 제17권3호
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

${\Delta}K_{eff}$ 제어 피로 균열 진전 시험 자동화 시스템에 관한 연구 (An Automated System for Constant ${\Delta}K_{eff}$ Fatigue Crack Growth Testing through Real-time Measurement of Crack Opening Load)

  • 신성철;송지호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.447-452
    • /
    • 2001
  • An automated system is developed to perform fatigue crack growth tests under constant effective stress intensity factor range ${\Delta}K_{eff}$. In the system, crack length and crack opening load are measured in real-time by using the unloading elastic compliance method. The system consists of two personal computers, an analogue electrical subtraction circuit, a stepping motor, a stepping motor driver, a PIO board, and the application software used to integrate the whole system. The performance of the developed system was tested and discussed performing constant ${\Delta}K_{eff}$ crack growth tests on a CT specimen of 7075-T6 aluminum alloy. The performance of the system is found to be strongly dependent on the accuracy of measurements of crack opening load. Besides constant ${\Delta}K_{eff}$ testing, the system is expected to be successfully applied for automation of various fatigue tests.

  • PDF

Performance Analysis of Real-Time Kinematic GPS Positioning using Continuous Operating Reference Station

  • Lee In-Su;Lee Jae-One;An Sang-Jun
    • Spatial Information Research
    • /
    • 제12권4호
    • /
    • pp.371-382
    • /
    • 2004
  • 상시관측소는 GPS 측량에서 높은 정확도를 제공하며, GPS 사용자가 두 대의 수신기를 사용해야하는 필요를 제거함으로써 GPS 측위를 향상시킨다. 이전에는, 사용자에게 상시관측소로부터 제공된 자료를 후처리함으로써 수행되어졌다. 그러나 RTK-GPS 측량을 이용한 실시간 처리로 향상될 때 상시관측소의 능률은 최대가 될 것이며, 그 이유는 사용자가 기준점을 이용하지 않고서도 실시간으로 cm급의 정확도를 획득할 수 있기 때문이다. 본 연구에서는 인터넷을 통해 RINEX 형태로 제공되는 GPS 상시관측소 자료와 기존의 삼각점을 이용해 관측망을 형성하고 임의점의 좌표를 추출하였다. 또한, 기준점으로써 추출된 임의점을 이용해 RTK GPS를 수행하였다.

  • PDF

실시간 제어기를 이용한 마이크로 열식 질량공기 유량센서의 열특성 측정 (Measurements of Thermal Characteristics for a Micro-Fabricated Thermal Mass Air Flow Sensor With Real-Time Controller)

  • 박병규;이준식
    • 대한기계학회논문집B
    • /
    • 제33권8호
    • /
    • pp.573-579
    • /
    • 2009
  • A thermal mass air flow sensor, which consists of a micro-heater and thermal sensors on the silicon-nitride thin membrane structure, is micro-fabricated by MEMS processes. Three thermo-resistive sensors, one for the measurement of microheater temperature, the others for the measurement of membrane temperature upstream and downstream of the micro-heater respectively, are used. The micro-heater is operated under the constant temperature difference mode via a real time controller, based on inlet air temperature. Two design models for microfabricated flow sensor are compared with experimental results and confirmed their applicabilities and limitations. The thermal characteristics are measured to find the best flow indicator. It is found that two normalized temperature indicators can be adopted with some advantages in practice. The flow sensor with this control mode can be adopted for wide capability of high speed and sensitivity in the very low and medium velocity ranges.

광산란 방식 실시간 미세먼지 측정 및 모니터링 시스템 개발 (Development of Detection and Monitoring by Light Scattering in Real Time)

  • 이누리;엄현욱;조현숙
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.134-139
    • /
    • 2018
  • 최근 초미세먼지는 사회적 재난으로 간주될만큼 국민건강에 심각하게 영향을 미쳐 사회문제가 되고 있다. 기존의 미세먼지 측정 방식은 베타선 흡수방식을 사용하여 실시간 측정 및 소형화가 어려운 단점이 존재한다. 본 논문에서는 광산란 방식을 사용하여 소형화 및 저비용의 센싱 장치를 개발하였다. 광산란 방식을 적용한 센서는 내부에 반도체 레이저 다이오드를 사용하여 구성하였으며, 전압레벨의 신호를 주파수레벨로 변환하여 기존 방식의 한계를 극복하고 미세먼지 입자 크기별 분리가 가능하도록 구현하였다. 또한 개발 시스템은 블루투스 통신으로 스마트폰과 연결하여 미세먼를 모니터링하고, 장치를 제어할 수 있다.

국토지리정보원 기준국 사용 Network RTK 테스트베드 구축 (Construction of Network RTK Testbed Using Reference Stations of NGII)

  • 김부겸;기창돈
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제13권1호
    • /
    • pp.103-110
    • /
    • 2024
  • In this paper, a test bed for real-time network Real-Time Kinematic (RTK) research was constructed using reference stations of the NGII. A group of candidate station networks was derived, including three stations in Seoul. The group consisted of four stations with a distance of less than 100 km between them. Among several candidates, a network composed of stations with short distances between them and demonstrating good data quality for all reference stations was selected as the test bed. After collecting real-time data in Radio Technical Committee for Maritime services (RTCM) format from the selected stations and conducting a noise analysis on measurements, mm-level carrier phase measurement noise was confirmed. Afterwards, the user set the reference station inside the test bed and analyzed the network RTK positioning performance of the MAC method using the GPS L1 frequency as post-processing. From the result of the analysis it was confirmed that the residual error for all users was within 10 cm after applying the correction. Additionally, after determining integer ambiguities through Least-squares AMBiguity Decorrelation Adjustment (LAMBDA), it was confirmed that the fix rate was 100%, and all ambiguities were resolved as true values.

벡터 예측 알고리즘과 칼만 필터를 이용한 다변측량법 개선 (Improvement of Multilateration using Vector Prediction Algorithm and Kalman Filter)

  • 김정하;주양익;이성근;박상국;서동환
    • 한국정보통신학회논문지
    • /
    • 제16권12호
    • /
    • pp.2792-2799
    • /
    • 2012
  • 3개 혹은 그 이상의 고정노드로 구성된 다변측량법은 실내의 실시간 위치 인식 시스템 분야에서 현재 널리 사용되고 있다. 하지만 이 고정노드 중 일부가 장애물 및 고정노드의 불안정에 따라 통신도달성이 결여된 상황에서는 효율적 위치 정보를 획득하기가 어렵다. 이러한 환경에서 위치측정 결여 및 변동을 개선하기위하여 본 논문에서는 TOF(Time of Flight)기반으로 이동노드의 변위 추정을 위한 벡터예측알고리즘과 효율적인 거리평균을 위한 칼만필터를 이용하여 기존의 다변측량법에서 발생하는 내재적 위치측정오차를 줄일 수 있는 새로운 알고리즘을 제안한다. 보행자가 이동노드와 함께 이동하고 임의의 고정노드로부터 거리측정이 실패하더라도, 현재 및 이전 거리측정 값을 이용하는 제안한 알고리즘은 이동노드와 거리측정에 실패한 고정노드 사이의 거리를 예측할 수 있다. 실험결과 기존의 방법 대비 위치추정 성능과 효율이 향상됨을 확인하였다.

영상기반 실시간 후미추돌 위험도 분석기법 개발 (Methodology for Evaluating Real-time Rear-end Collision Risks based on Vehicle Trajectory Data Extracted from Video Image Tracking)

  • 오철;조정일;김준형;오주택
    • 대한교통학회지
    • /
    • 제25권5호
    • /
    • pp.173-182
    • /
    • 2007
  • 기존의 교통안전도 평가 방법은 이력자료에 대한 의존도가 높았기 때문에, 실시간 모니터링 환경에서는 교통안전평가에 한계가 있었다. 그러나 최근 급속한 센서 및 통신기술의 발달은 개별차량의 주행궤적과 같은 미시적 자료 수집이 가능한 환경을 제공하게 되었다. 이런 미시적 자료수집이 가능한 환경을 최대한 반영하기위해, 본 연구에서는 영상 이미지 트랙킹을 통해 추출되는 개별차량의 주행정보와 기존 교통상충분석기법을 응용한 실시간 교통안전 평가 방법론을 제시하였다. 차량 간 안전거리 개념을 반영한 RSI(Real-time Safety Index)와 첨단안전차량의 효과 및 성능평가 등에 주로 사용되는 TTC(Time-To-Collision) 개념을 추출된 차량 주행정보에 적용한 실시간 교통안전 평가 방법론을 개발하였다. 본 연구에서 제시된 방법론은 향후 교통사고 분석 및 실시간 안전평가를 위한 자료수집이 가능한 검지시스템의 개발과 평가 등에 효과적으로 활용될 것으로 기대된다.

SPR-based Antibody-Antigen Interaction for Real Time Analysis of Carbamate Pesticide Residues

  • Yang, Gil-Mo;Kang, Suk-Won
    • Food Science and Biotechnology
    • /
    • 제17권1호
    • /
    • pp.15-19
    • /
    • 2008
  • This research was conducted to develop a quick and sensitive method of detecting carbamate residues using the immobilization of antibody-antigen interactions with surface plasmon resonance (SPR). We have used commercialized surface plasmon resonance equipment (Biacore 3000). The antibody used for the immunoassay was specific for glutathione-s-transferase (GST) and the antigens included several carbamate pesticides (carbofuran, carbaryl, and benfuracarb). When antigens were applied to the protein GST, the detection limit was 2 ng/mL of carbamate pesticide. The fabricated protein GST maintained its activity for over 200 measurements. Thus we determined that the SPR biosensors could detect the specific reversible binding of a reactant in solution to a binding partner immobilized on the surface of the sensor and allow real-time detection and monitoring.

일반적인 GPS 수신기를 위한 채널별 다중경로오차 검출 기법 (Channelwise Multipath Detection for General GPS Receivers)

  • 이형근;이장규;지규인
    • 제어로봇시스템학회논문지
    • /
    • 제8권9호
    • /
    • pp.818-826
    • /
    • 2002
  • Since multipath phenomenon frequently occurs when a Global Positioning System receiver is placed in urban area crowded with large buildings, efficient mitigation of multipath effects is necessary to resolve. In this paper, we propose a new multipath detection technique that is useful in real-time positioning with a general Global Positioning System receiver. The proposed technique is based on a channelwise multipath test statistic that efficiently indicates the degree of fluctuations induced by multipath error. The proposed multipath test statistic is operationally advantageous because it does not require any specialized hardware nor any pre-computation of receiver position, it is directly related to standard $\chi$$^2$-distributions, and it can adjust the detection resolution by increasing the number of successive measurements. Simulation and experiment results verify the performance of the proposed multipath detection technique.