• Title/Summary/Keyword: ratio table

Search Result 617, Processing Time 0.036 seconds

Research on optimal FCL (Frequently Called List) table sizes in a circuit-switched network including wireless subscribers (무선 가입자를 포함한 회선교환망에서의 최적의 FCL (Frequently Called List) 테이블 크기에 관한 연구)

  • 김재현;이종규
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.1-9
    • /
    • 1994
  • In this paper, we have studied optimal FCL(Frequently Called List) table sizes in a grid topology circuit-switched network including wireless subscribers. The FCL table gives the position information of a destination subscriber for a call. When the call is generated in a node, this call is routed by the referenced position information of the destination subscriber in FCL table. In this paper, we have proposed an efficient routing algorithm, mixed FSR(Flood Search Routing) and DAR(Dynamic Adaptive Routing), considering moving wireless subscribers. Also, we have simulated hit ratio and incorrect ratio as performance parameters, consequently proposed the object function composed of table search time, hit ratio, incorrect ratio, FSR time and DAR time, and derived the optimal FCL table size by using it.

  • PDF

Comparison of Pluviation and Vibrating table method on the Minimum void ratio of crushed sand (인공모래의 최소간극비 산정 시 플루베이션과 진동대 시험법의 적용성 비교)

  • Cho, Youg-Soon;Kim, Rae-Hyun;Kim, Jae-Jeong;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1290-1295
    • /
    • 2008
  • The relative density of soil indicate loose and dense state of sand. Because sand is low compressibility, initial relative density of sand is important effect factor of compression and shear behavior. To measure exactly relative density, the exactly maximum and minimum void ratio was determinated by laboratory tests. Generally, vibrating table method is adapted for minimum void ratio(KS F 2345). However KS F 2345 is not consider the particle break during the vibrating table test. In this study, The minimum void ratio is compared with a method of Pluviation and Vibrating table test results using the K-7(crushed sand). It is concluded that the K-7 sand particles were crushed during the vibrating table test and vibrating table test is not a suitable test for a crushed sand $e_{min}$.

  • PDF

Confirmation of particle crushing on the vibrating table test of artificial sand (인공모래에 대한 진동대 시험시 입자파쇄 현상 확인)

  • Cho, Yong-Soon;Kim, Rae-Hyun;Kim, Jae-Jung;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1391-1398
    • /
    • 2009
  • The vibrating table method is widely used to estimate the minimum void ratio $e_{min}$. The existing method recommended in ASTM and KS F, however, can not consider the particle crushing during the vibrating table test. In this study, the particle cursing phenomenon was investigated by comparing vibrating table test with pluviation method using artificial sand (K-7). Vibrating table test for the artificial sand was confirmed which can crush of particle during the test. This study demonstrates that vibrating table test is an ineffective method to produce the more reliable $e_{min}$ of artificial sand.

  • PDF

Application of Lookup Table Technique with PID Controller for East Flow Ratio Response

  • Klaynil, P.;Pannil, P.;Chaikla, A.;Julsereewong, P.;Tirasesth, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.504-504
    • /
    • 2000
  • The flow ratio in the industrial process is usually accomplished by using PID controller with series type ratio. But always the large overshoot and a long rise time may be achieved from this conventional control. These problems are involved to the inexact flow ratio control. In order to avoid this poor performance. the paper presents a designing of the two controller modes for the flow ratio plants. This proposed controller combine the lookup table technique and the well-known PID controller to obtain the fast response and low overshoot of flow ratio control. The PID controller mode will be operated when the flow ratio reaches the preset value while the lookup table technique mode is applied for initial operation. The data in tile table is calculated by the valve sizing equation and convened to the valve position control signal. The experimental results show that the transient and steady state responses of the control systems using the proposed technique can be efficiently obtained when compared with tile conventional controller.

  • PDF

Inference for Order Restrictions on Odds in 2 * k Contingency Tables

  • Oh, Myong-Sik
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.3
    • /
    • pp.381-391
    • /
    • 1996
  • In the analysis of contingency table with ordered categories, the relationship between odds for adjacent categories has received con-siderable interest. We consider likelihood ratio tests of independence against an order restriction on odds in 2 $\times$ k contingency tables.

  • PDF

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

A Study of Cardiothoracic Ratio in Insurance Medicine (심흉비(心胸比)의 보험의학적(保險醫學的) 고찰(考察))

  • Im, Young-Hoon
    • The Journal of the Korean life insurance medical association
    • /
    • v.2 no.1
    • /
    • pp.152-181
    • /
    • 1985
  • A statistical analysis on the cardiothoracic ratio in insurance medicine was carried out for 5,200 insured persons who were medically examined including photofluorography of the chest at the Honam medical department, Dong Bang life insurance Company, Ltd from November, 1979 to August, 1984. The results were as follows: 1. The mean value of the cardiothoracic ratio in all of the insured was $44.2{\pm}4.3%$. The mean value of the cardiothoracic ratio was $43.1{\pm}4.1%$ in all males and $45.2{\pm}4.2%$ in all females, and the difference of the values between males and females showed statistical significance(P<0.001). In each age group, the mean value of the cardiothoracic ratios of female was higher than that of male without exception and the difference of the values between males and females showed statistical significance(P<0.001). The mean value of the cardiothoracic ratio showed gradual increase with age from the second to sixth decade in male(P<0.05 or 0.001 after fourth decade) and from the second to seventh decade in female(P<0.05 or 0.001 from the second to sixth decade). 2. Correlation between both sexes and among age groups relating to the cardiothoracic ratios of the insureds seen to be a physiological phenomenon of the cardiac size and should be considered on the rating of the cardiothoracic ratio. Based on the correlation above mentioned and an author's assumption that the incidence of normal and abnormal cardiothoracic ratios in each age group would show the same rate in male and female, author prepared a modified rating table from the existing table; in male group the existing rating table is used and in female group the ratings of 0, 30-50, 50-100 and 100-D are to calculate by the cardiothoracic ratio of 51%or under, 52-56%, 57-61% and 62% or over respectively in the age group below 39, by the cardiothoracic ratio of 52% or under, 53-57%, 58%-62% and 63% or over respectively in the age group of 40-49, by the cardiothoracic ratio of 53% or under, 54-58%, 59-63% and 64% or over respectively in the age group over 60. 3. The relative frequency distribution polygons of the cardiothoracic ratio of both sexes drawn in a pair on one coordinate plane revealed lying in juxtaposition each other horizontally and showed the shifting of females polygon to male's one toward the direction of greater value of the cardiothoracic ratio at a short distance which increased gradually with age. 4. The minimum cardiothoracic ratio was 31.2% and the maximum cardiothoracic ratio was 63.6% in all of the insured. 5. In each age group, no significant sex difference was found in the relative frequency distribution of ratings by the cardiothoracic ratios of 5,200 insureds by using the rating table modified by author, while significant sex difference was found by using the existing rating table.

  • PDF

New Growth Power, Economic Effect Analysis of Software Industry (신성장 동력, 소프트웨어산업의 경제적 파급효과 분석)

  • Choi, Jinho;Ryu, Jae Hong
    • Journal of Information Technology Applications and Management
    • /
    • v.21 no.4_spc
    • /
    • pp.381-401
    • /
    • 2014
  • This study proposes the accurate economic effect (employment inducement coefficient, hiring inducement coefficient, index of the sensitivity of dispersion, index of the power of dispersion, and ratio of value added) of Korea software industry by analyzing the inter-industry relation using the modified inter-industry table. Some previous studies related to the inter-industry analysis were reviewed and the key problems were identified. First, in the current inter-industry table publishedby the Bank of Korea, the output of software industry includes not only the output of pure software industry (package software and IT services) but also the output of non-software industry due to the misclassification of the industry. This causes the output to become bigger than the actual output of the software industry. Second, during rewriting the inter-industry table, the output is changing. The inter-industry table is the table in the form of rows and columns, which records the transactions of goods and services among industries which are required to continue the activities of each industry. Accordingly, if only an output of a specific industry is changed, the reliability of the table would be degraded because the table is prepared based on the relations with other industries. This possibly causes the economic effect coefficient to degrade reliability, over or under estimated. This study tries to correct these problems to get the more accurate economic effect of the software industry. First, to get the output of the pure software section only, the data from the Korea Electronics Association(KEA) was used in the inter-industry table. Second, to prevent the difference in the outputs during rewriting the inter-industry table, the difference between the output in the current inter-industry table and the output from KEA data was identified and then it was defined as the non-software section output for the analysis. The following results were obtained: The pure software section's economic effect coefficient was lower than the coefficient of non-software section. It comes from differenceof data to Bank of Korea and KEA. This study hasa signification from accurate economic effect of Korea software industry.

The Influence of Position Change on Autonomic Nervous System Function (자세변화가 자율신경계에 미치는 영향)

  • Kim, In-Bae;Kim, Eun-Kyung;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitudes (가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성)

  • Lee, Sung-Kyung;Lee, Hye-Ri;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.842-849
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitudes, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitudes. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass does not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitudes.

  • PDF