Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography  

Yoon, Jong-Tae (Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center)
Lee, Ki-Baek (Department of Radiologic Technology, Chungbuk Health & Science University)
Publication Information
Journal of radiological science and technology / v.45, no.4, 2022 , pp. 313-320 More about this Journal
Abstract
Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.
Keywords
3D Cerebral Angiography; Table Height Adjustment; Magnification Radio Adjustment; Lens Radiation Dose; Surface Dose;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Anam C, Fujibuchi T, Toyoda T, et al. The impact of head miscentering on the eye lens dose in CT scanning: Phantoms study. Journal of Physics: Conference Series. 2019;1204(1):012022
2 Buermann L, Burns DT. Air-kerma cavity standards. Metrologia. 2009;46(2):S24.
3 Schernthaner RE, Haroun RR, Nguyen S, Duran R, Sohn JH, Sahu S, et al. Characteristics of a New X-Ray Imaging System for Interventional Procedures: Improved Image Quality and Reduced Radiation Dose. Cardiovasc Intervent Radiol. 2018;41(3):502-8.   DOI
4 Moritake T, Matsumaru Y, Takigawa T, Nishizawa K, Matsumura A, Tsuboi K. Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters. AJNR Am J Neuroradiol. 2008;29(10):1910-7.   DOI
5 Lakhan SE, Kaplan A, Laird C, Leiter Y. The interventionalism of medicine: Interventional radiology, cardiology, and neuroradiology. Int Arch Med. 2009;2(1):27.
6 Sandborg M, Rossitti S, Pettersson H. Local skin and eye lens equivalent doses in interventional neuroradiology. Eur Radiol. 2010;20(3):725-33.   DOI
7 Van Strijen MJ, GrGnhagen T, Mauti M. Evaluation of a noise reduction imaging technology in iliac digital subtraction angiography: Noninferior clinical image quality with lower patient and scatter dose. J Vasc Interv Radiol. 2015;26(5):642-50.e1.   DOI
8 Sanchez RM, Vano E, Fernadez JM, Rosati S, Lopez-lbor L. Radiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures. AJNR Am J Neuroradiol. 2016;37(3):402-7.   DOI
9 Song Y, Han S, Kim BJ, Oh SH, Kim JS, Kim TI, et al. Low-Dose Fluoroscopy Protocol for Diagnostic Cerebral Angiography. Neurointervention. 2020;15(2):67-73.   DOI
10 Kweon DC. Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray. Journal of Biomedical Engineering Research. 2017;38:256-63.   DOI
11 Kim S, Toncheva G, Anderso-Evans C, Huh BK, Gray L, Yoshizumi T. Kerma area product method for effective dose estimation during lumbar epidural steroid injection procedures: Phantom study. AJR Am J Roentgenol. 2009;192(6):1726-30.   DOI
12 Guenego A, Mosimann PJ, Pereira VM, Nicholson P, Zuber K, Lotterie JA, et al. Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: An international, multicentric, retrospective study in 1096 patients. Eur Radiol. 2019;29(7):3506-15.   DOI
13 Stewart, FA, Akleyev AV, Hauer-jensen M, Hendry JH, Kleiman NJ, MacVittie TJ, et al. ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs-threshold doses for tissue reactions in a radiation protection context. Annals of the ICRP. 2012;41:1-322.
14 ICRU Report 51. Quantities and Units in Radiation Protection Dosimetry. ICRU, Bethesda; 1993.
15 Lee NR, Han SJ, Lee BI, Cho KW. A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD. Journal of Radiation Protection. 2012;37(2):96-102.   DOI
16 Kim KS, Kim SC. Comparison of image quality and effective dose by additional filtration on digital chest tomosynthesis. Journal of Radiological Science and Technology. 2015;38(4):347-53.   DOI
17 Joo YC, Jung YJ. Evaluation of Relationship between Radiation Dose and Image Quality according to Source to Image Receptor Distance in Rib Series Radiography. Journal of Radiological Science and Technology. 2018;41(5):391-6.   DOI
18 Song Y, Kim Y, Han S, Kim TI, Choi JH, Maeng JY, et al. Estimated radiation dose according to the craniocaudal angle in cerebral digital subtraction angiography: Patient and phantom study. J Neuroradiol. 2019;46:345-50.   DOI
19 Safari MJ, Wong JHD, Kadir KAA, Thorpe NK, Cutajar DL, Petasecca M, et al. Real-time eye lens dose monitoring during cerebral angiography procedures. Eur Radiol. 2016;26(1):79-86.   DOI