• 제목/요약/키워드: rating standard

Search Result 319, Processing Time 0.024 seconds

An Analysis of the Current State of Window Constructions in Small-scale Private Architecture in Consideration of the Energy Consumption Efficiency Rating System (소규모 민간건축에 있어서 에너지소비효율등급제를 고려한 창호공사 현황분석)

  • Kang, Suk-Pyo;Jin, Eun-Mi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.1
    • /
    • pp.43-51
    • /
    • 2015
  • At present, in the case of small and medium window manufacturers in South Korea, glazing and window frame manufacturers are divided into separate businesses. However, in the fenestration energy consumption efficiency rating system and the energy-saving design criteria for buildings, the coefficient of overall heat transmission standard for windows is defined by window sets, which integrate glazing and window frames. At most construction sites, windows are constructed by installing separately supplied glass and frames. Research that can integrate the reality and the system is therefore necessary. The present study first investigated and analyzed the on-site situation of the fenestration energy consumption efficiency rating system. According to the results, while overall understanding of the fenestration energy consumption efficiency rating system was high, satisfaction with it was low, and the general practice at construction sites was to use windows assembled on site rather than integrated window systems manufactured at factories, thus making it difficult to confirm that the current rating system was well applied on site. Consequently, the reality of industrial sites must be reviewed and a realistic alternative to the fenestration energy consumption efficiency rating system must be presented instead of focusing on theory.

Development of Rating Curve for High Water Level in an Urban Stream using Monte Carlo Simulation (Monte Carlo Simulation을 이용한 도시하천의 고수위 Rating Curve 개발)

  • Kim, Jong-Suk;Yoon, Sun-Kwon;Moon, Young-Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1433-1446
    • /
    • 2013
  • In this study, we proposed a methodology to develop Rating Curves for high water level using rainfall generation by the Monte Carlo Simulation (MCS) technique, optimized rainfall-runoff model, and flood routing model in an urban stream. The developed stage discharge Rating Curve based on observed data was contained flow measurement errors and uncertainties. The standard error ($S_e$) for observations was 0.056, and the random uncertainty ($2S_{mr}$) was analyzed by ${\pm}1.43%$ on average, and up to ${\pm}4.27%$. Moreover, it was found that the Rating Curve extensions by way of logarithmic and Stevens methods were overestimated to compare with the urban basin scale. Finally, we confirmed that the high water level extension by random generation of hydrological data using MCS can be reduced uncertainty of the high water level, and it will consider as a more reliable approach for high water level extension. In the near future, this results can be applied to real-time flood alert system for urban streams through construction of the high water level extension system using MCS procedures.

TMDL Evaluation of Nakdong River Basin Using Load Duration Curve and Streamflow-Load Rating Curve (부하지속곡선과 유량-부하량 상관곡선을 이용한 낙동강 유역의 오염총량평가)

  • Shon, Tae Seok;Joo, Jae Seung;Park, Jae Beom;Shin, Hyun Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5B
    • /
    • pp.475-481
    • /
    • 2011
  • The TMDL standard flow as applying watershed management regime uses the average low flow of past 10 years. Moreover, the TMDL implementation assessment has been enforced through management of pollutant load satisfied objective water quality. Even though the present allocation and management through averaged low flow are still convenient, they are not enough to solve ultimate goals of watershed management to keep up recovery of water body. To maintain the same water quality concentration, the standard flow is required to consider total discharge in management plan which helps to keep healthy ecosystem. In view of this, it would be possible to approach reasonable assessment by reflecting variably changeable discharge from precipitation-streamflow relation and the TMDL standard establishment considering artificial regulated flow. Therefore, this study attempts to develop the TMDL method using Load Duration Curve (LDC) and Streamflow-Load Rating Curve (QLRC) considering total discharge and finds drawbacks with solutions as applying on Nakdong river TMDL unit watershed. Finally, this research evaluates possibility of application on pollutant load allocating and implementation assessment in Korea.

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

Considered for Global Guide Lines and Rating Model of the ethics management (윤리경영의 글로벌 가이드라인 및 평가모델 고찰)

  • Lee, Jong-Woon;Ree, Sang-Bok
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.11a
    • /
    • pp.351-359
    • /
    • 2006
  • Author considered the contradiction of Capitalism and its solution, systemized the concept to newly define ethics management and social responsibility whose various terminologies are used in domestic and foreign country and compared, analyzed and considered global guideline. Standard organization and global evaluation model of internationally-performed ethics management on the basis of the concept of new ethics management.

  • PDF

The short-circuit calculation and circuit breaker selection as IEC standard (IEC규격에 의한 고장전류해석 및 차단기용량선정)

  • Lee, Kyung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.433-436
    • /
    • 2007
  • This paper analyzes how to calculate the three phase short-circuit currents for ac electrical system and select the high & low voltage circuit breaker based on IEC60609, IEC60056 and IEC60947-2 standards. We proposed the multiplying factor considering system time constant and circuit breaker rating to select circuit breaker accurately.

  • PDF

Post-Earthquake Damage Evaluation for R/C Buildings Based on Residual Seismic Capacity (지진피해를 받은 철근콘크리트 건물의 지진피해도 판정)

  • Lee Kang Seok;Kang Dae-Eon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.109-112
    • /
    • 2005
  • In this paper described is the basic concept of the Guideline for Post-earthquake Damage Assessment of RC buildings, revised in 2001, in Japan. This paper discusses the damage rating procedures based on the residual seismic capacity index R, the ratio of residual seismic capacity to the original capacity, that is consistent with the Japanese Standard for Seismic Evaluation of Existing RC Buildings, and their validity through calibration with observed damage due to the 1995 Hyogoken-Nambu (Kobe) earthquake. Good agreement between the residual seismic capacity ratio and damage levels was observed.

  • PDF

Calculation of Ampacity for Bare Overhead Conductors (가공송전선로용 나전선의 허용전류 산정에 대한 검토)

  • Sohn, H.K.;Lee, H.K.;Lee, E.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.303-305
    • /
    • 2000
  • Many standards have published for calculating the ampacity of bare overhead conductors. Although these standards use the same basic heat balance concept, they use different approaches to calculate ampacity ratings. This paper looks at the different approaches used to calculate individual heat balance terms, at the overall impact of these terms on the ampacity rating. And this paper is proposed to the selection of proper standard and atmospheric conditions for calculating the ampacity of bare overhead conductors.

  • PDF

The relationship between prediction accuracy and pre-information in collaborative filtering system

  • Kim, Sun-Ok
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.4
    • /
    • pp.803-811
    • /
    • 2010
  • This study analyzes the characteristics of preference ratings by dividing estimated values into four groups according to rank correlation coefficient after obtaining preference estimated value to user's ratings by using collaborative filtering algorithm. It is known that the value of standard error of skewness and standard error of kurtosis lower in the group of higher rank correlation coefficient This explains that the preference of higher rank correlation coefficient has lower extreme values and the differences of preference rating values. In addition, top n recommendation lists are made after obtaining rank fitting by using the result ranks of prediction value and the ranks of real rated values, and this top n is applied to the four groups. The value of top n recommendation is calculated higher in the group of higher rank correlation coefficient, and the recommendation accuracy in the group of higher rank correlation coefficient is higher than that in the group of lower rank correlation coefficient Thus, when using standard error of skewness and standard error of kurtosis in recommender system, rank correlation coefficient can be higher, and so the accuracy of recommendation prediction can be increased.

A Study on the Characteristics of Domestic Vehicle on the Roof Crush Test Considering the Enhanced Safety Standard, FMVSS 216 (북미 법규 강화를 고려한 국내 자동차의 천정강도 시험특성에 관한 연구)

  • Kim, Eun-Hee;Lee, Jae-Kwang;Lee, Moon-Gu;Hong, Min-Sung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.4
    • /
    • pp.348-354
    • /
    • 2009
  • In order to reduce the risk of roll over crash, one of the greatest risk events, National Highway Traffic Safety Administration(NHTSA) issued Notice of Proposed Rulemaking(NPRM) enhancing the safety standard on roof crush resistance, FMVSS No. 216 and changing some part of the test procedure. According to this NPRM, the boundary Gross Vehicle Weight Rating(GVWR) of the vehicles applied by this standard is extended from 2,722kg(6000 lb) to 4,536 kg(10000 lb) and the applied test force is increased from 1.5 times to 2.5 times of Unloaded Vehicle Weight (UVW). Also the current limit on the amount of roof crush, 127mm(5 inch), is replaced with a new requirement of maintaining enough headroom without touching the head of a seated 50% male dummy. In this paper, we carried out the rollover crash test on some domestic cars and investigated their safety due to the KMVSS No. 92 and the enhanced safety standard, FMVSS No. 216, respectively. The result shows that most of them can satisfy the new standards but further tests will be necessary, especially for heavier cars.

  • PDF