DOI QR코드

DOI QR Code

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources

바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰

  • Received : 2017.03.29
  • Accepted : 2017.05.15
  • Published : 2017.07.01

Abstract

The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

표준 중량 충격원의 실제 충격원 재현성에 대한 논란이 있음에도 현재 기준에서는 뱅머신 방식만 사용하고 있다. 현행 기준의 평가방법 및 등급 기준이 충격원 특성을 고려하지 못하고 있어 충격원의 선택에 따라 바닥충격음 차단 성능 등급에 차이가 발생하기 때문이다. 본 연구는 충격원 특성 외에 바닥 진동 거동 특성을 함께 고려한 현행 기준의 바닥충격음 평가 방법 고찰을 목적으로 한다. 공동주택 mock-up 실험동에서 표준 중량 충격원과 실충격원에 대하여 바닥충격음을 측정하고 이를 이용하여 해외 평가 방법과 우리나라의 평가 방법을 비교 검토하였다. 또한 현행 바닥충격음 평가 기준의 대상 주파수 범위를 벗어나는 저주파수 대역의 음압레벨은 네텔란드의 저주파 소음 인지 곡선과 국내 연구자가 제안한 저주파 소음 기준안을 이용하여 평가하였다. 그 결과 기준 및 평가 산정 방법에 따라 성능 평가 결과가 상이하며, 바닥 진동의 지배 주파수 범위에서 모든 충격원에 대한 바닥충격음 가청 소음으로 인식하여 성가시게 느낄 가능성이 매우 크다. 현행 평가 기준의 단일수치 평가량 산정 방법은 충격원에 따라 상이한 음압레벨 스펙트럼 특성을 제대로 반영하지 못하며, 바닥의 진동 거동 지배 주파수를 포함하는 저주파수 대역의 음압레벨을 고려하지 않고 있어 바닥충격음에 대한 평가 결과와 사람의 인지 수준에 차이가 발생할 수 있다. 따라서 충격원에 따른 음압레벨의 스펙트럼 특성과 저주파수 대역의 음압레벨을 반영할 수 있도록 현행 기준의 평가 방법을 보완할 필요가 있다.

Keywords

References

  1. International Standard Organization for Standardization (2013), Acoustics-Rating Of Sound Insulation In Buildings And Of Building Elements - Part 2: Impact Sound Insulation, ISO 717-2 :2013.
  2. Japanese Standard Association (2000), Acoustics-Rating Of Sound Insulation In Buildings And Of Building Elements - Floor Impact Sound Insulation, JIS A 1419-2 :2000.
  3. Jeon, J., Lee, P., Jeong, J., and Park, J. (2006), Comparison of Standard Floor Impact Sources with a Human Impact Source, Transactions of the Korean Society of Noise and Vibration Engineering, KSNVE, 16(8), 789-796. https://doi.org/10.5050/KSNVN.2006.16.8.789
  4. Jeong, J. and Jeon, J.(2005), Floor Impact Noise Measurement and Evaluation Method Using Impact Ball, Transactions of the Korean Society of Noise and Vibration Engineering, KSNVE, 15(10), 1160-1168. https://doi.org/10.5050/KSNVN.2005.15.10.1160
  5. Kim, K., Choi, G., Jeong, Y., and Yang, K. (2005), Impact Power Characteristics as Behavior of Real Impact Source(Child), Transactions of the Korean Society of Noise and Vibration Engineering, KSNVE, 15(5), 542-549. https://doi.org/10.5050/KSNVN.2005.15.5.542
  6. Korean Agency for Technology and Standards (2007), Rating of floor impact sound insulation for impact source in buildings and of building elements-Part 2 : Floor impact sound insulation against standard heavy impact source, KS F 2863-2: 2007.
  7. Korean Agency for Technology and Standards (2012), Field measurements of floor impact sound insulation of buildings-Part 2: Method using standard heavy impact sources, KS F 2810-2: 2012.
  8. Lee, J., Lee, W., Choi, K., Gu, J., Jung, S., and Han, J. (2011), Management of Low-Frequency Noise, Proceeding of Academic Conference of the Korean Society of Noise and Vibration Engineering, KSNVE, 806-807.
  9. Ministry of Land, Infrastructure and Transport, Floor Impact Noise Insulation Admission and Management Criteria for Apartment House, 2016.
  10. Ministry of Land, Infrastructure and Transport, Regulation on Housing Construction Standards, 2017.
  11. Park, H., Kim, K., and Kim, S. (2013), Verification of Effectiveness of the Standard Floor Impact Source by Comparing with Living Impact Sources, Transactions of the Korean Society of Noise and Vibration Engineering, KSNVE, 23(12), 1117-1126. https://doi.org/10.5050/KSNVE.2013.23.12.1117