• Title/Summary/Keyword: rating curves

Search Result 83, Processing Time 0.026 seconds

Analysis of flood and sediment discharge characteristics on Cheonggyecheon (청계천 홍수량, 유사량 특성 분석)

  • Yoo, Chul-Sang;Kim, Kee-Wook;Kim, Kyoung-Jun;Park, Yong-Hee;Lee, Ji-Ho;Park, Hyun-Keun;Kim, Dae-Ha;Park, Sang-Hyoung;Park, Chang-Yeol;Kim, Byoung-Soo;Kim, Hyeon-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1849-1853
    • /
    • 2007
  • In this study, flow-sediment discharge characteristics and relationships are estimated for the Cheonggyecheon basin, newly restored in 2005. Flow and sediment discharge measurement is performed on Ogansugyo, Majanggyo 2 and Yongdugyo during the rainy seasons in 2005-2006. The parameters of Clark UH are estimated using measured data, and sediment rating curves are derived by using grading and concentration analysis. Concentration time and storage coefficient of Clark UH are estimated 0.5 hr and 0.63 hr for Majanggyo 2, and 0.4 hr and 0.45 hr for Yongdugyo, respectively. Grain size of sediments are composed of fine silt to fine sand (0.008-0.25mm) based on the sediment grain size classification (Lane, 1947). Flow-sediment relationships derived by using concentration analysis shows that sediment discharge has no obvious relationship with flow discharge.

  • PDF

Application of numerical models to determine wind uplift ratings of roofs

  • Baskaran, A.;Borujerdi, J.
    • Wind and Structures
    • /
    • v.4 no.3
    • /
    • pp.213-226
    • /
    • 2001
  • Wind uplift rating of roofing systems is based on standardised test methods. Roof specimens are placed in an apparatus with specified table size (length and width) then subjected to the required wind load cycle. Currently, there is no consensus on the table size to be used by these testing protocols in spite of the fact that a table size plays a significant role in evaluating the performance. This paper presents a study with the objective to investigate the impact of table size on the performance of roofing systems. To achieve this purpose, extensive numerical experiments using the finite element method have been conducted to investigate the performance of roofing systems subjected to wind uplift pressures. Numerical results were compared with results obtained from experimental work to benchmark the numerical modeling. Required table size and curves for the determinations of appropriate correction factors are suggested. This has been completed for various test configurations with thermoplastic waterproofing membranes. Development of correction factors for assemblies with thermoset and modified bituminous membranes are in progress. Generalization of the correction factors and its usage for wind uplift rating of roofs will be the focus of a future paper.

Diagnostic accuracy of digital images for detection of artificial chemical proximal caries (화학적 인공 인접면 치아우식증의 디지털 영상 진단능 평가)

  • Park Geum-Mee;Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.91-95
    • /
    • 2003
  • Purpose : To compare the diagnostic accuracy of proximal caries detection between Kodak Insight film and the Biomedisys CDX2000HQ digital (CCD) sensor. Materials and Methods: 156 proximal surfaces of extracted teeth, 78 of which had chemical artificial caries, were used in this study. Four observers interpreted the radiographs using a five-point confidence rating scale to record their diagnoses. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa values. Result: Analysis using receiver operating characteristic curves revealed the areas under each curve which indicated a diagnostic accuracy of 0.951 in Insight and 0.952 in CDX2000HQ digital sensor. ANOVA revealed no significant differences between the two images with respect to caries detection. Kappa values indicated that the mean intra-observer agreement was 0.85 and inter-observer agreement 0.71 in conventional radiography. In digital radiography, the mean intra-observer agreement was 0.84 and inter-observer agreement 0.72. Conclusion: The results suggest that no significant difference exists between the two modalities for artificial caries detection and that CDX2000HQ was as good as Insight film for this purpose.

  • PDF

Evaluation of the Irrigation Water Supply of Agricultural Reservoir Based on Measurement Information from Irrigation Canal (수로부 계측정보 기반 농업용 저수지의 관개용수 공급량 평가)

  • Lee, Jaenam;Noh, Jaekyoung;Kang, Munsung;Shin, Hyungjin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.6
    • /
    • pp.63-72
    • /
    • 2020
  • With the implementation of integrated water management policies, the need for information sharing with respect to agricultural water use has increased, necessitating the quantification of irrigation water supply using monitoring data. This study aims to estimate the irrigation water supply amount based on the relationship between the water level and irrigation canal discharge, and evaluate the reliability of monitoring data for irrigation water supply in terms of hydrology. We conducted a flow survey in a canal and reviewed the applicability of the rating curve based on the exponential and parabolic curves. We evaluated the reliability of the monitoring data using a reservoir water balance analysis and compared the calculated results of the supply quantity in terms of the reservoir water reduction rate. We secured 26 readings of measurement data by varying the water levels within 80% of the canal height through water level control. The exponential rating curve in the irrigation canal was found to be more suitable than the parabolic curve. The irrigation water supplied was less than 9.3-28% of the net irrigation water from 2017 to 2019. Analysis of the reservoir water balance by applying the irrigation water monitoring data revealed that the estimation of the irrigation water supply was reliable. The results of this study are expected to be used in establishing an evaluation process for quantifying the irrigation water supply by using measurement information from irrigation canals in agricultural reservoirs.

Seismic Fragility Analysis of Lightning Arrester Considering Various Damage States (다양한 손상상태를 반영한 피뢰기 설비의 지진취약도 해석)

  • Shin, Yooseong;Song, Jong-Keol
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.19-28
    • /
    • 2014
  • The seismic evaluation of electric power facilities in the switchyard of nuclear power plants is currently insufficient. In order to evaluate the seismic performance of lightning arrester subjected to four types of earthquake (near- and far-fault earthquakes, NEHRP Site Class A&B and D earthquakes), seismic fragility analysis using maximum likelihood estimation is performed considering various damage states. The comparison of the seismic fragility curves for three main parts of lightning arrester that are the busing, anchor and steel frame, reveals that the failure of lightning arrester is governed by the bushing damage mode such as porcelain cracking.

A Study on the Runoff Characteristics m Kangwon Watershed (So-yang River Watershed) (강원도 유역의 유출 특성에 관한 연구 (소양강댐 유역 중심으로))

  • Choi, Han-Kyu;Beak, Hyo-Sun;Lee, Min-Seop
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.223-232
    • /
    • 2001
  • This study is finding the most appropriate model of kangwondo watershed. To synthesize each hydrograph, It is found to several parameters which are used in existing hydrographes. then the synthestic hydrograph is compared and investigated with many hydrographes of the rivers in kanwondo. These methods, Nakayasu, Clark, SCS are used to calculate the run-off of this watershed. When the calculated run-off is compared with real rating-curves, then it is found that the SCS method using the Clark's concentrantion time is the best way on this area having large watershed, long river length and gentle water slope, the Nakayasu method is more suitable on this area having small watershed, short river length and steep water slope. Also it is founded from analyzing run-off hydrographes, peak run-off and peak time that the Clark's method applied Kirpich's concentration time way is suitable in the area of kangwondo.

  • PDF

A Consideration on the Head Injury Criterion of KNCAP (KNCAP 머리상해기준값에 관한 고찰)

  • Lim, J.M.;Lee, K.W.
    • Journal of Auto-vehicle Safety Association
    • /
    • v.4 no.2
    • /
    • pp.22-26
    • /
    • 2012
  • Prasad and Mertz published head injury risk curves for skull fracture and for Abbreviated Injury Scale (AIS) ${\geq}4$ brain injury due to forehead impacts based on the 15 ms HIC criterion. KNCAP adopted the HIC36 criterion for the male dummy and the HIC15 criterion for the female dummy. In this paper, it was studied that which of the HIC15 and HIC36 was more effective for the male dummy head injury evaluation. The frontal US-NCAP data for the 7 vehicles from the NHTSA test database were used to evaluate the head injuries. In the case of using the HIC15 and evaluation range 250~700, the discrimination of the rating for the occupant head injury was increased.

Development of the Automatic Turnout (자동 분수공의 개발)

  • 저하우;이남호;김성준;최진용;한형근;한휘남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.36 no.4
    • /
    • pp.33-38
    • /
    • 1994
  • Floating-type automatic turnout was developed for the purpose of reducing labor cost and labor-working hours related to turnout management. The point of automation is to use a flexible-float within the turnout. The weight of float is changed by emptying and filling with water at the beginning and ending of irrigation. The turnout is controlled to open and close small bole on the float bottom using electromagnets. With the weight control of float. the gate of turnout is opened by the empty float to begin irrigatiom and is closed by the filled float to stop irrigation. The turnout was designed to be operated by the main computer and to minimize electric power consumption by sending an electric current at the beginning and ending of irrigation. The functional experiment was succesfully carried out and the rating curves for both free overflow condition and submerged flow condition were derived.

  • PDF

Diagonstic Evaluation of X-Ray Imaging using Fuzzy Logic Systems (Fuzzy Logic Systems을 이용한 X-선 영상의 진단평가)

  • Lee, Yong-Gu
    • 전자공학회논문지 IE
    • /
    • v.46 no.3
    • /
    • pp.62-67
    • /
    • 2009
  • In this paper, ROC curves were designed by using Fuzzy Logic Systems. ROC curve is used for diagnostic evaluation and the person evaluating ROC curve is chosen as a first-level diagnostician. For rating diagnostic capability on ROC curve through learning, the chest X-ray image is used. The images used for making a diagnosis are X-ray film being both noise and signal. The result over diagnostic capability difference between the male and the female represented a man had better than a woman but that difference can be ignored.

A Study on Evaluation of Bending Fatigue Strength in SCM415 Carburized Spur Gear (SCM415 침탄치차의 굽힘피로강도평가에 관한 연구)

  • 류성기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.763-770
    • /
    • 1998
  • This paper deals with evaluation of bending fatigue strength in SCM415 carburized spur gears. The constant stress amplitude fatigue test is performed by using an electrohydraulic servo-controlled pulsating tester. The S-N curves are obtained and the enhanvement of fatigue strength due to carburized treatment is clarified. In this study the improvement of fatigue strength is assumed to be caused by an increase of both hardness and residual stress and experimental formula has been proposed for the estimation of bending fatigue strength of carburized gears. The effect of surface conditions on the fatigue strength is evaluated quantitatively and it is close to the relative surface condition factor used in the ISO strength rating formula.

  • PDF