• Title/Summary/Keyword: rate of release

Search Result 2,219, Processing Time 0.034 seconds

Coronaviruses: SARS, MERS and COVID-19 (코로나바이러스: 사스, 메르스 그리고 코비드-19)

  • Kim, Eun-Joong;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.4
    • /
    • pp.297-309
    • /
    • 2020
  • Coronaviruses were originally discovered as enzootic infections that limited to their natural animal hosts, but some strains have since crossed the animal-human species barrier and progressed to establish zoonotic diseases. Accordingly, cross-species barrier jumps resulted in the appearance of SARS-CoV, MERS-CoV, and SARS-CoV-2 that manifest as virulent human viruses. Coronaviruses contain four main structural proteins: spike, membrane, envelope, and nucleocapsid protein. The replication cycle is as follows: cell entry, genome translation, replication, assembly, and release. They were not considered highly pathogenic to humans until the outbreaks of SARS-CoV in 2002 in Guangdong province, China. The consequent outbreak of SARS in 2002 led to an epidemic with 8,422 cases, and a reported worldwide mortality rate of 11%. MERS-CoVs is highly related to camel CoVs. In 2019, a cluster of patients infected with 2019-nCoV was identified in an outbreak in Wuhan, China, and soon spread worldwide. 2019-nCoV is transmitted through the respiratory tract and then induced pneumonia. Molecular diagnosis based on upper respiratory region swabs is used for confirmation of this virus. This review examines the structure and genomic makeup of the viruses as well as the life cycle, diagnosis, and potential therapy.

Effects of Several Medicinal Plants Extract on Survival Rate, Chlorophyll Contents and Photosynthetic Electron Transport Activity of Liverwort Photoautotrophic Cultured Cell (약용식물 추출액이 우산이끼 자가관양배양세포의 생존율, 엽록소함량 및 광합성전자전달 활성에 미치는 영향)

  • 정형진;권순태;김시무
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.2
    • /
    • pp.133-141
    • /
    • 1995
  • The effects of allelochemicals from medicinal plants have been studied as photo-synthetic inhibitor for photoautotrophic(PA) cultured cells. The extracts from 9 plant species were used for measuring the physiological effects on the liverwort cultured cell in following areas; germination inhibition, chlorophyll contents, hill activity, cell viability, photosynthetic oxygen evolution,and protein pattern changes on SDS PAGE. Germination inhibitions were detected in all plant after treating with 10% extract. Especially, treatment with 10% extract from Pulsatilla koreana and Aconitum carmichael inhibited germinations completely. Chlorophyll fornation was inhibited completely by treating PA cells with extract of Pulsatilla koreana, whose effect was similar to that of DCMU 10-3M, inhibitor for photosynthetic electron trans-fer. The treatment with extract from Pulsatilla koreana on PA cell showed the highest hill activity and the lowest cell viability among extracts studied. Oxygen releasing has been decreased down to 14-77% after treating with extracts from Pinellia ternata, Araliacont inentaila, Pulsatilla koreana and Vitex rotundifolia. Especially, 60$\mu$l of Pulsatilla koreana extract into 2ml mixture of PA cell inhibit-ed oxygen release up to 50%. Protein bands on SDS-PAGE, 14kD, 31kD, 41kD, 53kD, and 73kD, were not detected after treating Pulsatilla koreana extract on PA cells.

  • PDF

Influence of the Fire on Emergency Evacuation Support System (대공간용 비상피난지원 시스템에 화재가 미치는 영향 분석)

  • Kim, JiTae;Sung, Kun Hyuk;Park, Won Hee;Lee, Duck Hee;Woo, Jun You;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.626-631
    • /
    • 2018
  • An emergency evacuation support system is used to maintain evacuation routes by pressurizing a space inside screens. In cases of fire, it is important to understand the thermal distributions in the tunnel for preventing system failure. In this study, we numerically investigated the effect of fire on an emergency evacuation support system in a large fabric store with some fire scenarios with different combustibles. The critical temperature for system failures was assumed to be $200^{\circ}C$. As a result, the highest temperature was predicted in the ceiling part due to the effect of a ceiling jet, and the fire safety of the screen was secured at distances of 20 to 30 m according to the heat release rate. To prevent the inflow of smoke into the system, it is necessary to maintain more than 5 Pa if positive pressure inside the smoke screen. The results of this study could be useful for designing an emergency evacuation support system.

Relationship between Tropical Cyclone Intensity and Physical Parameters Derived from TRMM TMI Data Sets (TRMM TMI 관측과 태풍 강도와의 관련성)

  • Byon, Jae-Young
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.4
    • /
    • pp.359-367
    • /
    • 2008
  • TRMM TMI data were used to investigate a relationship between physical parameters from microwave sensor and typhoon intensities from June to September, 2004. Several data such as 85GHz brightness temperature (TB), polarization corrected temperature (PCT), precipitable water, ice content, rain rate, and latent heat release retrieved from the TMI observation were correlated to the maximum wind speeds in the best-track database by RSMC-Tokyo. Correlation coefficient between TB and typhoon intensity was -0.2 - -0.4 with a maximum value in the 2.5 degree radius circle from the center of tropical cyclone. The value of correlation between in precipitable water, rain, latent heat, and typhoon intensity is in the range of 0.2-0.4. Correlation analysis with respect to storm intensity showed that maximum correlation is observed at 1.0-1.5 degree radius circle from the center of tropical cyclone in the initial stage of tropical cyclone, while maximum correlation is shown in 0.5 degree radius in typhoon stage. Correlation coefficient was used to produce regressed intensities and adopted for typhoon Rusa (2002) and Maemi (2003). Multiple regression with 85GHz TB and precipitable water was found to provide an improved typhoon intensity when taking into account the storm size. The results indicate that it may be possible to use TB and precipitable water from satellite observation as a predictor to estimate the intensity of a tropical cyclone.

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

Nitrogen Removal in Column Wetlands Packed with Synthetic Fiber Treating Piggery Stormwater (축산단지 강우 유출수 처리를 위한 합성섬유충진 습지의 질소제거에 관한 연구)

  • Cheng, Jing;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.68-75
    • /
    • 2016
  • A set of lab-scale polymer synthetic fiber packed column wetlands composing three columns (CW1, CW2 and CW3) with different hydraulic regimes, recirculation frequencies and pollutant loading rates, were operated in 2012. Synthetic fiber tested as an alternative wetland medium for soil mixture or gravel which has been widely used, has very high pore size and volume, so that clogging opportunity can be greatly avoided. The inflow to the wetland was artificial stormwater. All the wetlands achieved effective removal of TSS (94%~96%), TCOD (68%~73%), TN (35%~58%), TKN (62%~73%) and NH4-N (85%~ 99%). Particularly, it was observed that COD was released from the fiber during one distinct period in all wetlands. This was probably due to the degradation of polymer fiber, and the released organic matters were found to serve as carbon source for denitrification. In addition, with longer retention time and frequent recirculation, lower effluent concentration was observed. With higher pollutant loading rate, higher nitrification and denitrification rates were achieved. However, although organic matters were released from the fiber, the lack of carbon source was still the limiting factor for the system since the release persisted only for 40 days.

Experimental Study on the Designed Ventilation System Performance at Rescue Station in Tunnel Fire (터널 내 화재발생시 구난역 내의 설계된 환기 시스템 성능에 대한 실험적 연구)

  • Kim, Dong-Woon;Lee, Seong-Hyeok;Ryou, Hong-Sun;Yoon, Sung-Wook
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • In this study, the l/35 reduced-scale model experiment were conducted to investigate designed ventilation system performance at rescue station in tunnel fire. A model tunnel with 2 mm thick of steel, 10 m long, 0.19 m high and 0.26m was made by using Froude number scaling law. The cross-passages installing escape door at the center. were connected between accident tunnel and rescue tunnel. The n-heptane pool fire, $4cm\times4cm$, with heat release rate 698.97W were used as fire source. The fire source was located in the center and portal of accident tunnel as Worst case.. An operating ventilation system extracted smoke amount of 0.015 cms. The smoke temperature and carbon monoxide. concentration in cross-passage were measured to verify designed ventilation system. The results showed that, in center fire case without ventilation in accident tunnel, smoke did not propagated to rescue station. In portal tire case, smoke spreaded to rescue station without ventilation. But smoke did not propagated to rescue station with designed ventilation.

The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: measurement of the BAO and growth rate of structure of the emission line galaxy sample from the anisotropic power spectrum between redshift 0.6 and 1.1

  • Arnaud de Mattia;Vanina Ruhlmann-Kleider;Anand Raichoor;Ashley J Ross;Amelie Tamone;Cheng Zhao;Shadab Alam;Santiago Avila;Etienne Burtin;Julian Bautista;Florian Beutler;Jonathan Brinkmann;Joel R Brownstein;Michael J Chapman;Chia-Hsun Chuang;Johan Comparat;Helion du Mas des Bourboux;Kyle S Dawson;Axel de la Macorra;Hector Gil-Marin;Violeta Gonzalez-Perez;Claudio Gorgoni;Jiamin Hou;Hui Kong;Sicheng Lin;Seshadri Nadathur;Jeffrey A Newman;Eva-Maria Mueller;Will J Percival;Mehdi Rezaie;Graziano Rossi;Donald P Schneider;Prabhakar Tiwari;M Vivek;Yuting Wang;Gong-Bo Zhao
    • Monthly Notices of the Royal Astronomical Society
    • /
    • v.501 no.4
    • /
    • pp.5616-5645
    • /
    • 2021
  • We analyse the large-scale clustering in Fourier space of emission line galaxies (ELG) from the Data Release 16 of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey. The ELG sample contains 173 736 galaxies covering 1170 deg2 in the redshift range 0.6 eff = 0.845 we measure DV(zeff)/rdrag = 18.33+0.57-0.62, with DV the volume-averaged distance and rdrag the comoving sound horizon at the drag epoch. In combination with the RSD measurement, at zeff = 0.85 we find fσ8(zeff) = 0.289+0.085-0.096, with f the growth rate of structure and σ8 the normalization of the linear power spectrum, DH(zeff)/rdrag = 20.0+2.4-2.2 and DM(zeff)/rdrag = 19.17 ± 0.99 with DH and DM the Hubble and comoving angular distances, respectively. These results are in agreement with those obtained in configuration space, thus allowing a consensus measurement of fσ8(zeff) = 0.315 ± 0.095, DH(zeff)/rdrag = 19.6+2.2-2.1 and DM(zeff)/rdrag = 19.5 ± 1.0. This measurement is consistent with a flat ΛCDM model with Planck parameters.

Biological Characteristics of Two Natural Enemies of Thrips, Orius strigicollis (Poppius) and O. laevigatus (Fieber) (Hemiptera: Anthocoridae) (총채벌레 천적 으뜸애꽃노린재(Orius strigicollis)와 미끌애꽃노린재(Orius laevigatus)의 생물학적 특성 비교)

  • Kim, Jeong-Hwan;Kim, Hwang-Yong;Byoun, Young-Woong;Kim, Yong-Heon
    • Korean journal of applied entomology
    • /
    • v.47 no.4
    • /
    • pp.421-428
    • /
    • 2008
  • With the comparison of native Orius strigicollis (Poppius) to European O. laevigatus (Fieber), we investigated biological characteristics such as developmental period, fecundity, life span, predation ability, and augmentation after release. Experiments were carried out at five temperature condition, $15^{\circ}C\;20^{\circ}C,\;25^{\circ}C\;30^{\circ}C$, and $35^{\circ}C$. In the case of O. strigicollis, egg period was $3.1{\sim}14.9$ days (hatchability: $46.7{\sim}88.2%$), and developmental period of nymphs was $9.4{\sim}42.8$ days (survival rate: $2.4{\sim}96.5%$). Fecundity at each temperature was 28.1, 107.9, 123.6, 127.3, and 18.1, respectively. Life span of adults was 63.4, 40.1, 22.1, 18.3, and 11.0 days, respectively. In the case of O. laevigatus, egg period was $3.1{\sim}13.5$ days (hatchability: $65.0{\sim}89.9%$), and developmental period of nymphs was $9.3{\sim}42.0$ (survival rate: $4.3{\sim}80.6%$) days. Fecundity at each temperature was 101.8, 218.6, 224.5, 219.5, and 15.7. Life span of adults was 70.6, 66.4, 32.6, 34.5, and 7.3 days, respectively. In long-day condition (16L:8D), fecundity of O. strigicollis and O. laevigatus was 105.8 $(18^{\circ}C){\sim}142.4(25^{\circ}C)$ and 109.5 $(18^{\circ}C){\sim}191.5(25^{\circ}C)$, respectively. In short-day condition (10L:14D), fecundity of them was 1.0 $(18^{\circ}C){\sim}31.8(25^{\circ}C)$ and 63.0 $(18^{\circ}C){\sim}198.8(25^{\circ}C)$, respectively. Daily prey consumption of second instar Frankliniella occidentalis was 14.3 and 10.9, respectively. In greenhouse, density of O. strigicollis begins to increase from mid May and peaked about early July (1.8 individual/flower), while that of O. laevigatus begins to increase from mid March and peaked about early June (6.6 individual/flower).

A Study on the Movement Distribution of Common Grey Mullet, Mugil cephalus in Funnel Net Fishing Ground of the Yeosu Coastal Sea (여수 연안 승망 어장에서 숭어의 이동 분포에 관한 연구)

  • Kim, Dong-Soo;Joo, Chan-Soon;Park, Ju-Sam
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • In order to find out the environmental factors influencing movement of common grey mullet, Mugil cephalus in funnel net fishing ground of the Dolsan-do, Yeosu southern sea area, the oceanographic factor such as the water temperature, isobath and tidal current were observed respectively, the water temperature was compared with the amount of common grey mullet caught by funnel net. Also, to investigate the movement direction of common grey mullet in same sea area, 160 common grey mullets of body length 22 to 51cm caught at funnel nets of the Dolsan-do southern sea area were marked and then released at 5 positions in 5 times. The results obtained are summarized as follows : 1. The water temperature at the funnel net fishing ground of Dolsan-do in 2002 was ranged from 6.9 to 27.4$^{\circ}C$. The water temperature was displayed a maximum value in August to increase from March and a minimum value in February of the ensuing year to decrease from September. The catches of gray mullet caught by funnel net were generally abundant from March to September, but decreased sharply from October. The optimum range of water temperature for the funnel nets fishing was situated between 15.0 to 25.0$^{\circ}C$. 2. The isobath from 6m to 13m in coast sea set up funnel nets were densely distributed and the depth more than 14m of isobath were widely spreaded to the open sea at Dolsan-do southern sea area. 3. The tidal current of the coast sea set up funnel nets flowed southward and northward along the coast ato ebb and flood tide respectively. The direction of tidal current to the open sea was southeast at ebb tide with the mean speed 43cm/sec, but northwest at flood with the mean speed 25cm/sec. 4. The recapture rate through the experiment duration showed 9.4%. The recapture rate in Gyedong area was very high value with 33.3% as compared with others. The movement of common grey mullet in Dolsan-do southern sea area trended toward a inner bay and north bound mainly.