• 제목/요약/키워드: rate measurement bias

검색결과 62건 처리시간 0.022초

표적추적센서의 측정 바이어스 오차 보상에 의한 사격통제장치 성능 향상 기법 (A performance improvement method in the gun fire control system compensating for measurement bias error of the target tracking sensor)

  • 김재훈;유준
    • 한국군사과학기술학회지
    • /
    • 제3권2호
    • /
    • pp.121-130
    • /
    • 2000
  • A practical method is proposed to improve hit probability of the digital gun fire control system, when the measured rate of the tracking sensor becomes biased under some operational situation. For ground moving target it is shown that the well-known Kalman filter which uses position measurement only can be optimally used to eliminate the rate bias error. On the other hand, for 3D moving aircraft we present a new algorithm which incorporate FIR-type filter, which uses position and rate measurement at the same time, and the fixed-lag smoother using position measurement only, and show that it has the optimal performance in terms of both estimation accuracy and response time.

  • PDF

모사된 화재의 열적환경에서 열전대를 이용한 온도 측정오차에 관한 실험적 연구 (An Experimental Study on Temperature Measurement Bias using Thermocouple in Simulated Thermal Environments of Fire)

  • 한호식;윤홍석;황철홍;김성찬
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.7-13
    • /
    • 2017
  • An experimental study was conducted to identify the quantitative measurement bias for the bare-bead thermocouple (TC), which was widely used for measuring temperature in fire experiments. To this end, an apparatus could be controlled individually gas flow rate, preheating temperature and incident radiative heat flux was developed to simulate the thermal environments of fire. A relative measurement bias of bare-bead TC was evaluated with the comparison of double-shield aspirated TC. As a result, the relative measurement bias of bare-bead TC was gradually increased with the increase in radiative heat flux with constant gas temperature. The relative bias was also significantly increased with the decrease in gas temperature. Quantitatively, at the gas temperature of $20^{\circ}C$, the bare-bead TC had the relative bias of approximately 400% with the radiative heat flux of $20kW/m^2$ corresponding to thermal radiation level of the flashover. The present study was intend to provide fire researchers with methodologies for the reanalyses of temperature measured using bare-bead TC, radiation corrections, and validation of fire modeling.

Target State Estimator Design Using FIR filter and Smoother

  • Kim, Jae-Hun;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.305-310
    • /
    • 2002
  • The measured rate of the tracking sensor becomes biased under some operational situation. For a highly maneuverable aircraft in 3D space, the target dynamics changes from time to time, and the Kalman filter using position measurement only can not be used effectively to reject the rate measurement bias error. To cope with this problem, we present a new algorithm which incorporate FIR-type filter and FIR-type fixed-lag smoother, and demonstrate that it has the optimal performance in terms of both estimation accuracy and response time through an application example to the anti-aircraft gun fire control system(AAGFCS).

UKF를 사용한 AHRS의 자기장 측정 편차 추정 (Bias Estimation of Magnetic Field Measurement by AHRS Using UKF)

  • 고낙용;송경섭;정석기;이종무;최현택;문용선
    • 한국해양공학회지
    • /
    • 제31권2호
    • /
    • pp.177-182
    • /
    • 2017
  • This paper describes an unscented Kalman filter approach to estimate the bias in magnetic field measurements. A microelectromechanical systems attitude heading reference system (MEMS AHRS) was used to measure the magnetic field, together with the acceleration and angular rate. A magnetic field is usually used for yaw detection, while the acceleration serves to detect the roll and pitch. Magnetic field measurements are vulnerable to distortion due to hard-iron effect and soft-iron effect. The bias in the measurement accounts for the hard-iron effect, and this paper focuses on an approach to estimate this bias. The proposed method is compared with other methods through experiments that implement the navigation of an underwater robot using an AHRS and Doppler velocity log. The results verify that the compensation of the bias by the proposed method improves the navigation performance more than or comparable to the compensation by other methods.

자동 Error counter를 이용한 RSFQ switch 소자의 Bit Error Rate 측정 (Bit Error Rate measurement of an RSFQ switch by using an automatic error counter)

  • 김세훈;김진영;백승헌;정구락;한택상;강준희
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.21-24
    • /
    • 2005
  • The problem of fluctuation-induced digital errors in a rapid single flux quantum (RSFQ) circuit has been very important issue. So in this experiment, we calculated error rate of RSFQ switch in superconductiyity ALU, The RSFQ switch should have a very low error rate in the optimal bias. We prepared two circuits Placed in parallel. One was a 10 Josephson transmission lines (JTLs) connected in series, and the other was the same circuit but with an RSFQ switch placed in the middle of the 10 JTLs. We used a splitter to feed the same input signal to the both circuits. The outputs of the two circuits were compared with an RSFQ XOR to measure the error rate of the RSFQ switch. By using a computerized bit error rate test setup, we measured the bit error rate of 2.18$\times$$10^{12}$ when the bias to the RSFQ switch was 0.398mh that was quite off from the optimum bias of 0.6mA.

유압서보밸브의 인-프로세스 성능 진단에 관한 연구 I - 유압실린더 위치제어계의 경우 - (A Study on In-Process Performance Diagnosis of Hydraulic Servovalves - First Report : Position Control System -)

  • 김성동;김경호;송재수;함영복;이재천
    • 유공압시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.7-14
    • /
    • 2006
  • In this paper, an in-process diagnosis method for performance of position control servo system was studied, which was based upon null bias, slew-rate ratio and delay time measurement. Slew-rate ratio and delay time were analyzed by theoretical analysis, computer simulation and experiment. As a result of these analysis, when spool of servovalve was weared, slew-rate ratio was decreased and delay time was increased.

  • PDF

한약 복용이 산후 유즙분비에 미치는 효과에 대한 체계적 문헌고찰 (A Systematic Review and Meta Analysis of Randomized Controlled Trials of the Clinical Effect on Taking a Herbal Medicine on Postpartum Lactation)

  • 이혜정;이수정;황덕상;이창훈;장준복;이진무
    • 대한한방부인과학회지
    • /
    • 제34권3호
    • /
    • pp.137-156
    • /
    • 2021
  • Objectives: The purpose of this study is to assess the effect of taking herbal medicine for the postpartum lactation. Methods: We searched 9 databases for recent three years, that contained four english, two chinese, one japanese and two korean database from September 17, 2016 to December 31, 2020. Randomized controlled trials (RCTs) were eligible. Measurement of outcome included total curative effective rate, volume of lactation, volume of milk supplement, and serum prolactin concentration. The risk of bias was assessed by two independent authors using the Cochrane risk of bias tool. Results: Total 725 of studies was screened, 11 RCTs were finally selected. Number of participants per study ranged from 60 to 257. The treatment group of taking a herbal medicine is effective for improving total curative effective rate, volume of lactation, volume of milk supplement, and serum prolactin concentration compared with control group. Because most of the studies had considerable heterogeneity in terms of type of intervention and comparison for outcome measurement, meta analysis for quantitative analysis was impossible. Conclusions: This studies showed that taking a herbal medicine is effective on increasing volume of lactation and speeding up the start of the first breastfeeding. However, included studies suffered from incomplete reporting, high or unclear risk of bias and substantial heterogeneity between studies. In the Future, further high-quality RCTs are needed to prove effectiveness of herbal medicine for breastfeeding and reduce the risk of bias.

한국 물리치료 학술지에 무작위대조연구의 비뚤림 위험 평가: 2018~2022년 검토 (TheAssessment of risk of bias in randomized controlled trials published in the Korean Journal of Physical Therapy: A 2018~2022 review)

  • 임재현;박치복;김병근
    • 대한물리치료과학회지
    • /
    • 제30권4호
    • /
    • pp.82-91
    • /
    • 2023
  • Background: Randomized controlled trials (RCTs) provide evidence on the effectiveness and safety of interventions and inform systematic reviews and guideline preparation for clinical application. However, methodological flaws can occur in many RCTs, and Cochrane's risk of bias version 2 (RoB2) can be used to evaluate RCTs' risk of bias (RoB). However, physical therapy RCTs in Korea did not confirm RoB. Therefore, the purpose of this study was to evaluate RoB using RoB2 in RCTs published in the Korean Physical Therapy Journal. Design: Review. Methods: The RCTs subject to evaluation were RCTs published in 11 physical therapy journals in Korea from 2018 to 2022. RoB2 evaluated a total of five domains: bias arising from the randomization process, bias due to deviations from intended interventions, bias due to missing outcome data, bias in measurement of the outcome, and bias in selection of the reported result. Results: A total of 616 RCTs were evaluated. As for bias arising from the randomization process, high risk was the highest at 555 (90.1%), followed by low risk at 41 (6.7%) and some concerns at 20 (3.2%). For bias due to deviations from intended interventions, the proportion of some concerns was the highest at 390 (63.3%), followed by high risk at 218 (35.4%) and low risk at 8 (1.3%). As for the bias due to missing outcome data, the rate of low risk was the highest at 399 (64.8%), followed by high risk at 159 (25.8%) and some concerns at 58 (9.4%). As for bias in measurement of the outcome, high risk was the highest at 294 (47.7%), followed by low risk at 224 (36.4%) and some concerns at 98 (15.9%). In the bias due to missing outcome data, the ratio of high risk was the highest at 610 (99%), followed by low risk at 4 (0.7%) and some concerns at 2 (0.3%). Conclusion: Most of the RoB evaluation results of RCTs published in the Korean Physical Therapy Journal were rated as high risk. Methodological quality of RCTs needs to be improved.

Hot-carrier 효과로 인한 MOSFET의 성능저하 및 동작수명 측정 (Hot-carrier Induced MOSFET Degradation and its Lifetime Measurement)

  • 김천수;김광수;김여환;김보우;이진효
    • 대한전자공학회논문지
    • /
    • 제25권2호
    • /
    • pp.182-187
    • /
    • 1988
  • Hot carrier induced device degradation characteristics under DC bias stress have been investigated in n-MOSFETs with channel length of 1.2,1.8 um, and compared with those of LDD structure device with same channel length. Based on these results, the device lifetime in normal operating bias(Vgs=Vds=5V) is evaluated. The lifetimes of conventional and LDD n-MOSFET with channel length of 1.2 um are estimated about for 17 days and for 12 years, respectively. The degradation rate of LDD n-MOSFET under the same stress is the lowest at n-region implnatation dose of 2.5E15 cm-\ulcorner while the substrate current is the lowest at the dose of 1E13cm-\ulcorner Thses results show that the device degradation characteristics are basic measurement parameter to find optimum process conditions in LDD devices and evaluate a reliability of sub-micron device.

  • PDF

전기화학적 노이즈 저항 측정에서의 불확도 평가 (Uncertainty evaluation in electrochemical noise resistance measurement)

  • 김종집;강수연
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.