• 제목/요약/키워드: rapid detection test

검색결과 333건 처리시간 0.027초

Rapid, Sensitive, and Specific Detection of Clostridium tetani by Loop-Mediated Isothermal Amplification Assay

  • Jiang, Dongneng;Pu, Xiaoyun;Wu, Jiehong;Li, Meng;Liu, Ping
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권1호
    • /
    • pp.1-6
    • /
    • 2013
  • Tetanus is a specific infectious disease, which is often associated with catastrophic events such as earthquakes, traumas, and war wounds. The obligate anaerobe Clostridium tetani is the pathogen that causes tetanus. Once the infection of tetanus progresses to an advanced stage within the wounds of limbs, the rates of amputation and mortality increase manifold. Therefore, it is necessary to devise a rapid and sensitive point-of-care detection method for C. tetani so as to ensure an early diagnosis and clinical treatment of tetanus. In this study, we developed a detection method for C. tetani using loop-mediated isothermal amplification (LAMP) assay, wherein the C. tetani tetanus toxin gene was used as the target gene. The method was highly specific and sensitive, with a detection limit of 10 colony forming units (CFU)/ml, and allowed quantitative analysis. While detecting C. tetani in clinical samples, it was found that the LAMP results completely agreed with those of the traditional API 20A anaerobic bacteria identification test. As compared with the traditional API test and PCR assay, LAMP detection of C. tetani is simple and rapid, and the results can be identified through naked-eye observation. Therefore, it is an ideal and rapid point-of-care testing method for tetanus.

인플루엔자 바이러스에 대한 신속 항원 검출 검사 검출한계의 융합적 분석 (Fusion Analytical Sensitivity of Rapid Influenza Antigen Limit of Detection Tests for Human Influenza virus)

  • 송창섭;성현호;김정현;김대은;박창은;윤중수
    • 한국융합학회논문지
    • /
    • 제9권3호
    • /
    • pp.165-171
    • /
    • 2018
  • 본 논문은 국내 인플루엔자 신속항원검사키트의 민감도의 검출한계를 분석하기위하여 국내 시판중인 인플루엔자 신속항원검사키트 5종을 대상으로 인플루엔자 바이러스 A형과 B형 배양액을 연속 희석하여 양성 검출 한계를 분석하였다. 분석 결과 A형의 육안측정결과는 웰스바이오 제품은 1:8192까지, II제품은 1:4096까지, I과 III제품은 1:512까지, IV제품은 1:128에서만 양성이 확인되었고, B형 육안측정결과는 웰스바이오 제품이 1:8192까지, II제품은 1:4096까지, I, III, IV제품의 경우 1:1024까지 양성이 확인되었다. 같은 검체의 기기 판독의 경우 A형, B형 모두 웰스바이오 제품이 1:8192까지, II제품이 1:4096까지, I제품은 1:2048까지 양성으로 확인되었다. 인플루엔자 신속항원검사의 민감도는 환자의 검체 채취부위 및 감염기간, 검체의 양 등에 따라 많은 차이가 있으므로, 검체의 채취시기 및 방법 등을 정확하게 준수해야할 것이며, 신속항원검사 키트의 민감도를 높이기 위한 다각적인 연구가 필요할 것으로 사료된다.

HPLC 및 신속검출방법을 이용한 우유내 Sulfamethazine의 분석에 관한 연구 (Determination of Sulfamethazine Using High Performance Liquid Chromatography and Several Screening Methods)

  • 김철현;백승천;문지웅
    • 한국식품위생안전성학회지
    • /
    • 제12권1호
    • /
    • pp.71-77
    • /
    • 1997
  • Sulfonamides, a therapeutically important group of antimicrobial drugs, are widely used to treat and prevent the acute systemic and skin infections in dairy cattle. They also pose an economic hazard through inhibition of growth of dairy starter cultures. This study was carried out to compare four screening methods for detection of sulfamethazine in milk and determine the positive milk sample by HPLC method. Sulfamethazine was used to spike at five levels of sulfamethazine. The Lac-Tek test and CharmII test were also consistent better than TTCII test and Delvo SP test in sulfamethazine detection. Analysis probabilities of obtaining a positive response with TTCII test and Delvo SP test assay at 50 ppb sulfamethazine level in milk samples were only 14%, 42% each. Whereas using the Lac-Tek test and CharmII test would have resulted in 100% identification of the five levels. Determination of sufamethazine using the HPLC method in the spiked milk were 10.64, 19.30, 30.76,38.83 and 50.23 ppb, respectively.

  • PDF

Development and Optimization of a Rapid Colorimetric Membrane Immunoassay for Porphyromonas gingivalis

  • Lee, Jiyon;Choi, Myoung-Kwon;Kim, Jinju;Chun, SeChul;Kim, Hong-Gyum;Lee, HoSung;Kim, JinSoo;Lee, Dongwook;Han, Seung-Hyun;Yoon, Do-Young
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권5호
    • /
    • pp.705-709
    • /
    • 2021
  • Porphyromonas gingivalis (P. gingivalis) is a major bacterial pathogen that causes periodontitis, a chronic inflammatory disease of tissues around the teeth. Periodontitis is known to be related to other diseases, such as oral cancer, Alzheimer's disease, and rheumatism. Thus, a precise and sensitive test to detect P. gingivalis is necessary for the early diagnosis of periodontitis. The objective of this study was to optimize a rapid visual detection system for P. gingivalis. First, we performed a visual membrane immunoassay using 3,3',5,5'-tetramethylbenzidine (TMB; blue) and coating and detection antibodies that could bind to the host laboratory strain, ATCC 33277. Antibodies against the P. gingivalis surface adhesion molecules RgpB (arginine proteinase) and Kgp (lysine proteinase) were determined to be the most specific coating and detection antibodies, respectively. Using these two selected antibodies, the streptavidin-horseradish peroxidase (HRP) reaction was performed using a nitrocellulose membrane and visualized with a detection range of 103-105 bacterial cells/ml following incubation for 15 min. These selected conditions were applied to test other oral bacteria, and the results showed that P. gingivalis could be detected without cross-reactivity to other bacteria, including Streptococcus mutans and Escherichia fergusonii. Furthermore, three clinical strains of P. gingivalis, KCOM 2880, KCOM 2803, and KCOM 3190, were also recognized using this optimized enzyme immunoassay (EIA) system. To conclude, we established optimized conditions for P. gingivalis detection with specificity, accuracy, and sensitivity. These results could be utilized to manufacture economical and rapid detection kits for P. gingivalis.

Respiratory syncytial virus 감염진단을 위한 신속항원검사의 유용성 (Clinical usefulness of rapid antigen test to detect respiratory syncytial virus infection)

  • 김형수;김희라;박기형;조경순
    • Clinical and Experimental Pediatrics
    • /
    • 제51권10호
    • /
    • pp.1071-1076
    • /
    • 2008
  • 목적: RSV 호흡기 바이러스 감염은 해마다 영유아에서 심한 호흡기 질환의 중요한 원인이 되고 있다. 이에 따라 최근 검사 방법이 간편하고 결과를 빨리 알 수 있는 면역 크로마토그래피법이 신속 항원 검사법으로서 소개되어 그 정확성과 임상에서의 유용성이 많이 연구되고 있으나 국내에서는 연구례가 드문 실정이다. 이에 저자들은 이 검사법의 정확성과 유용성을 평가하여 실질적인 검사법으로 정착시키고자 하였다. 방법: 2007년 4월부터 2008년 3월까지 발열, 기침, 천명, 호흡곤란, 빈호흡 등의 증상으로 외래 내원 및 입원치료를 받은 112명의 환아를 대상으로 비인두 가검물을 채취하여 RSV Respi-Strip과 효소 면역 측정법, RT-PCR(ASTEC)을 동시에 시행하였다. RT-PCR을 표준으로 하여 RespiStrip 과 EIA의 결과를 비교 분석하여 정확성과 유용성을 평가하였다. 결 과: RSV RespiStrip, RT-PCR, EIA에 양성을 보인 환아는 각각 42명, 45명, 39명 이었다. RespiStrip는 RT-PCR 검사법에 대하여 민감도 88%, 특이도 94%, 양성 예측도 90%, 음성 예측도는 92% 였으며 위양성률과 위음성률 그리고 일치도가 각각 5.9%, 11%, 83% 로 나왔다. EIA는 RT-PCR 검사법에 대하여 민감도 84%, 특이도 94%, 양성 예측도 90%, 음성 예측도 90%, 일치도 79% 로 나왔다. 결론: 신속 항원 검사가 비교적 민감도가 높으므로 RSV 감염의 선별 검사로서 적합하다고 생각한다. 외래 진료실에서 빠르고 경제적이며 간편하게 검사하여 조기에 적절한 치료를 함으로써 합병증을 예방할 수 있고 아울러 불필요한 항생제의 사용을 줄일 수 있다. 앞으로 이러한 신속검사가 실제 임상에서 많이 적용되리라 기대된다.

Optimization of disposable paper-based test strips for hypochlorous acid detection

  • Rita E. Ampiaw;Muhammad Yaqub;Changyeon Woo;Wontae Lee
    • Membrane and Water Treatment
    • /
    • 제14권4호
    • /
    • pp.181-189
    • /
    • 2023
  • The Covid-19 pandemic has increased demand for chlorine-based sanitizing solutions, most of which contain hypochlorous acid (HOCl) as an active agent. Free chlorine (HOCl) in these sanitizers is crucial for their efficacy. Disposable test strips are affordable and convenient tools for determining various qualitative and quantitative parameters. In this study, disposable opto-chemical test strips were developed by physically immobilizing 3,3',5,5'-tetramethylbenzidine (TMB) and o-dianisidine (o-D) reagents on chromatography and filter paper-based test strips for the visualization and detection of free chlorine in the form of HOCl. The reagents undergo a rapid color change upon reaction with chlorine through a redox reaction. The paper-based test strips showed rapid color change within a minute and a low sample volume requirement (1 ml). This portable, disposable paper-based test strip is a simple and cost-effective way to rapidly detect the presence of HOCl sanitizers for home and field applications. Both TMB and o-D successfully detected chlorine. Chromatography paper proved to be the more efficient option among the two papers used as substrates for the reagents (TMB and o-D). It exhibited high retention capacity and high performance in terms of color transformation when reacting with HOCl, even after two months of storage.

효소면역법을 이용한 Brucella abortus 항체 검출에 관한 연구 (Studies on enzyme-linked immunosorbent assay(ELISA) for detection of antibody to Brucella abortus)

  • 심항섭;국정희;정봉수;고태오;조중현;박유순
    • 한국동물위생학회지
    • /
    • 제21권2호
    • /
    • pp.107-115
    • /
    • 1998
  • In order to establish a rapid, sensitive and specific diagnostic method for detection of antibody to Brucella abortus, a enzyme-linked immunosorbent assay(ELISA) was adapted. The diagnostic efficacy of the established ELISA was compared with that of the standard tube agglutination test for B abortus. 1. It was found that the optimal concentration of antigen for this ELISA was 5$\mu\textrm{g}$/ml, the optimal dilution of conjugate was 1 : 2000, and the optimal dilution of serum was 1 : 200, respectively. 2. Cut off value in this ELISA was 1,102 that was determined by mean absorbance(at 492nm) of tube agglutination test negative serum added with the triple value of the standared devation. 3. The relationship between the tube agglutination test and ELISA was showen high corresponding rate with sensitivity(96.3%) and specificity(98.1%). 4. The efficacy of the ELISA for detection of B abortus antibody was compared with tube agglutination test In brucellosis outbreak farm. The sensivity of ELSIA was higher than tube agglutination test.

  • PDF

Bordetella 감염증(感染症)의 혈청학적진단(血淸學的診斷): 특히 보균돈검색(保菌豚檢索)을 위한 급속평판응집반응(急速平板凝集反應)의 실용화(實用化) (Serological Diagnosis of Bordetellosis: Application of Rapid Plate Agglutination Technique for the Detection of Carrier in Swine)

  • 강병규
    • 대한수의학회지
    • /
    • 제18권2호
    • /
    • pp.61-67
    • /
    • 1978
  • The detection of Bordetella bronchiseptica which is supposed to be an agent of the infectious atrophic rhinitis of swine, is likely to receive more attention in the future as the pork industry comes to realize that eradication of this infection from breeding herds is a practical possibility. Experiments described here were carried out to establish the rapid plate agglutination test for the detection of the infectious atrophic rhinitis of swine in the field using the criteria of antigen preparation, effects on the antigenecity after storing of the antigen and reaction appearing time. Also, the agglutinabilities between the plate and tube method were compared and the degree of pathological lesions were recorded in relation to tube agglutination titers. Obtained results were as follows: 1. No differences were noted in the agglutinabilities on the plate agglutination test between the treatments in antigen preparation-formolized, merthiolate-killed and living organism. 2. The agglutinability of the antigens did not show any significant changes until 10 weeks of storage at 4 C; however, after 10 weeks of storage, non-specific reaction was observed with the HPCD control sera. 3. The results of the plate and tube agglutination tests were not comparable but the effective use of the plate method in Bordetella bronchiseptica eradication programs in pigs especially in the sow is stressed as a screening test.

  • PDF

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • 한국축산식품학회지
    • /
    • 제35권4호
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.

Comparative Assessment of Diagnostic Performances of Two Commercial Rapid Diagnostic Test Kits for Detection of Plasmodium spp. in Ugandan Patients with Malaria

  • Bahk, Young Yil;Park, Seo Hye;Lee, Woojoo;Jin, Kyoung;Ahn, Seong Kyu;Na, Byoung-Kuk;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • 제56권5호
    • /
    • pp.447-452
    • /
    • 2018
  • Prompt diagnosis of malaria cases with rapid diagnostic tests (RDTs) has been widely adopted as an effective malaria diagnostic tool in many malaria endemic countries, primarily due to their easy operation, fast result output, and straightforward interpretation. However, there has been controversy about the diagnostic accuracy of RDTs. This study was conducted to evaluate the diagnostic performances of the 2 commercially available malaria RDT kits, RapiGEN Malaria Ag Pf/Pv (pLDH/pLDH) and Asan $EasyTest^{TM}$ Malaria Ag Pf/Pv (HRP-2/pLDH) for their abilities to detect Plasmodium species in blood samples collected from Ugandan patients with malaria. To evaluate the diagnostic performances of these 2 RDT kits, 229 blood samples were tested for malaria infection by microscopic examination and a species-specific nested polymerase chain reaction. The detection sensitivities for P. falciparum of Malaria Ag Pf/Pv (pLDH/pLDH) and Asan $EasyTest^{TM}$ Malaria Ag Pf/Pv (HRP-2/pLDH) were 87.83% and 89.57%, respectively. The specificities of the 2 RDTs were 100% for P. falciparum and mixed P. falciparum/P. vivax infections. These results suggest that the 2 RDT kits showed reasonable levels of diagnostic performances for detection of the malaria parasites from Ugandan patients. However, neither kit could effectively detect P. falciparum infections with low parasitaemia (<$500parasites/{\mu}l$).