• Title/Summary/Keyword: rapid detection test

Search Result 333, Processing Time 0.027 seconds

Development of cellulose nano beads based a rapid detection kit to detect staphylococcal enterotoxin B

  • Kim, Giyoung;Yoo, Jinyoung;Park, Saetbyeol
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.3
    • /
    • pp.549-557
    • /
    • 2019
  • Staphylococcal enterotoxin is a very common cause of food poisoning. Conventional detection methods for the toxin including enzyme-linked immunosorbent assays (ELISAs), chemiluminescence (ECL), and polymerase chain reaction (PCR) assays require a lot of time, efforts, and expert technicians. Lateral flow strip kits have shown great potential for the rapid detection of foodborne pathogens. The lateral flow strip kit is widely used in clinical settings because it is easy to use, fast, and cost effective. A typical lateral flow strip kit uses colloidal gold to generate a visual signal. However, the lateral flow strip kit based on colloidal gold has limited sensitivity to fulfill food safety regulation requirements. This study was performed to develop a rapid test kit for pathogenic staphylococcal enterotoxin B (SEB) in food samples. The rapid detection kit was fabricated based on a nitrocellulose lateral-flow strip. Cellulose nano beads and SEB antibodies were used as the tag and receptor, respectively, to improve the detection performance. Manually spotted SEB antibody and anti-rabbit antibody on the surface of the nitrocellulose membrane were used as test and control spots, respectively. The feasibility of the rapid test kit to detect SEB in samples was evaluated. The sensitivity of the kit was 10 ng/mL SEB spiked in PBS. Additionally, the rapid test kit could detect 1 ng/mL of SEB in chicken meat extract.

Detection of Methicillin-resistant Staphylococcs aureus from the Anterior Nares of Healthcare Workers in a Intensive Care Unit by Using PBP2a Rapid Kit and Direct Coagulase Test (중환자실에 근무하는 의료인의 전비강에서 PBP2a Rapid Kit와 직접 Coagulase 검사를 이용한 Methicillin-resistant Staphylococcus aureus의 검출)

  • Hong, Seung-Bok;Shin, Kyung-A;Son, Jae-Cheol;Shin, Seob-Kyeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.2
    • /
    • pp.86-91
    • /
    • 2010
  • We evaluated the performance of a novel screening test, PBP2a MRSA rapid kit (Dinona Inc., Iksan, Korea), for methicillin-resistant Staphylococcus aureus (MRSA) based on a immunochromatographic assay. The test is able to detect penicillin-binding protein 2a (PBP2a) using the nasal specimens from health care workers. The nasal specimens were obtained from 69 healthcare workers and were incubated in enrichment broth followed eight hours incubatin in BHI with cefoxitin $4{\mu}g/mL$. These broth were tested by PBP2a Rapid Kit. The enrichment broths were also directly tested for tube coagulase using the conventional identification method. 19 of 22 MRSA showed positive results by PBP2a rapid test and direct coagulase test (the sensitivity for detection of MRSA, 86.36%). While, 8 of 47 non-MRSA showed false positive results for the two tests. All of the 8 non-MRSA which showed false positive were co-colonizing isolates with MRCNS and MSSA. In addition, 46 of 49 methicillin-resistant staphylococci (MRS) showed positive results for PBP2a MRSA rapid kit (the sensitivity for detection of MRS, 93.8%), and all of 20 non-MRS showed negative results (specificity, 100%). The combination of PBP2a MRSA rapid kit and direct coagulase test showed the good sensitivity for detection of MRSA from anterior nares but frequently showed false positive results from the co-colonizing carrier with MRCNS and MSSA.

  • PDF

Optimized Expression, Purification, and Rapid Detection of Recombinant Influenza Nucleoproteins Expressed in Sf9 Insect Cells

  • Yoon, Sung-Jin;Park, Young-Jun;Kim, Hyun Ju;Jang, Jinwoo;Lee, Sang Jun;Koo, Sunwoo;Lee, Moo-Seung
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.10
    • /
    • pp.1683-1690
    • /
    • 2018
  • Accurate and rapid diagnosis of influenza infection is essential to enable early antiviral treatment and reduce the mortality associated with seasonal and epidemic infections. Immunochromatography is one of the most common methods used for the diagnosis of seasonal human influenza; however, it is less effective in diagnosing pandemic influenza virus. Currently, rapid diagnostic kits for pandemic influenza virus rely on the detection of nucleoprotein (NP) or hemagglutinin (HA). NP detection shows higher specificity and is more sensitive than HA detection. In this study, we time-dependently screened expression conditions, and herein report optimal conditions for the expression of recombinant nucleoprotein (rNP), which was 48 h after infection. In addition, we report the use of the expressed rNP in a rapid influenza diagnostic test (SGT i-flex Influenza A&B Test). We constructed expression vectors that synthesized rNP (antigen) of influenza A and B in insect cells (Sf9 cells), employed the purified rNP to the immunoassay test kit, and clearly distinguished NPs of influenza A and influenza B using this rapid influenza diagnostic kit. This approach may improve the development of rapid test kits for influenza using NP.

Rapid Detection Kit for Salmonella typhimurium (살모넬라 식중독균 신속 검출용 간이 진단키트)

  • Kim, Gi-Young;Yang, Gil-Mo;Park, Saet-Byeol;Kim, Yung-Hwun;Lee, Kang-Jin;Son, Jae-Yong;Kim, Hyuck-Joo;Lee, Sae-Rom
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.140-146
    • /
    • 2011
  • This study was performed to develop a rapid test kit for pathogenic Salmonella in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and biotin conjugated Salmonella antibodies were used as a tag and a receptor, respectively. Manually spotted Salmonella antibody and Neutravidin on nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Salmonella typhimurium in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Salmonella spiked in PBS. Also, the rapid test kit could detect $10^6$ cfu/mL of Salmonella in chicken meat extract.

Rapid Detection Kit for Staphylococcus aureus (황색포도상구균 신속 검출용 간이 진단키트)

  • Kim, Gi-Young;Park, Saet-Byeol;Moon, Ji-Hea;Lee, Sang-Dae;Lee, Sea-Rom;Jang, Youn-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.139-146
    • /
    • 2013
  • This study was performed to develop a rapid test kit for pathogenic Staphylococcus in various samples. The rapid detection kit has been fabricated based on nitrocellulose lateral-flow strip. Colloidal gold and Staphylococcus antibodies were used as a tag and a receptor, respectively. Manually spotted Staphylococcus antibody and anti-mouse antibody on the surface of nitrocellulose membrane were used as test and control lines, respectively. Feasibility of the rapid kit to detect Staphylococcus aureus in samples were evaluated. The intensity of the color of the test line started to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6$ cfu/mL Staphylococcus spiked in PBS. Also, the rapid test kit could detect $10^5$ cfu/mL of Staphylococcus in chicken meat extract.

Rapid Detection of Vancomycin-resistance Enterococci by SYBR Green Real-time PCR

  • Yang, Byoung-Seon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.2
    • /
    • pp.64-67
    • /
    • 2014
  • Vancomycin-resistant Enterococci (VRE) are a leading cause of a nosocomial infection. While seven glycopeptide resistance genotypes have been found in Enterococci, vanA and vanB are the most common resistance genotypes. Aims of this study were to detect antibiotic susceptibilities of 23 Enterococcus spp, which broke out in a university hospital by the disk diffusion test, to investigate specific genes of vanA and vanB by conventional and real-time PCR. PCR for vanA and vanB was performed on 23 Enterococci, all 23 were positive for vanA type. This study reports the validation of a simple and rapid VRE detection method that can be easily incorporated into the daily routine of a clinical laboratory. Early detection of VRE strains, including those with susceptibility to Vancomycin, is of paramount clinical importance, as it allows a rapid initiation of strict infection control practices as well as a therapeutic guidance for a confirmed infection. The real-time PCR method is a rapid technique to detect vanA in Enterococci. It is simple and reliable for the rapid characterization of VRE.

Development of the rapid detection kit for Salmonella spp. using immunochromatographic assay (면역크로마토그라피 기법을 이용한 Salmonella 속균 신속 검출킷트 개발)

  • Jung, Byeong-yeal;Jung, Suk-chan
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • An immunochromatographic (IC) strip for the rapid detection of Salmonella spp. in the enriched sample was developed. Affinity purified Salmonella polyclonal antibody was conjugated with 40 nm colloidal gold particles which were prepared by citrate method in our laboratory. The antigen-antibody-gold complex was captured by Salmonella antibody attached to test line of nitrocellulose membrane during the capillary migration of sample. Specificity of the IC strip was calculated to be 100% (12/12) and sensitivity was 97.6% (41/42) in the test with pure cultured bacteria. Salmonella was artificially inoculated into raw pork macerated with enrichment broth. And then it was 10-fold diluted from $5.2{\times}10^{8}CFU/ml$ to 5.2 CFU/ml. The IC strip could detect $5.2{\times}10^{6}CFU/ml$ before enrichment. However, the lowest limit of detection was 5.2 CFU/ml after overnight incubation. The results indicated that the IC assay was a rapid, economical and simple method with high specificity and sensitivity for the detection of Salmonella spp. without using any equipment.

A rapid and quantitative fluorescent microsphere immunochromatographic strip test for detection of antibodies to porcine reproductive and respiratory syndrome virus

  • Wei, Yanqiu;Yang, Baozhi;Li, Yunlong;Duan, Yongcheng;Tian, Deyu;He, Baoxiang;Chen, Chuangfu;Liu, Wenjun;Yang, Limin
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.68.1-68.8
    • /
    • 2020
  • A fluorescent microsphere-based immunochromatographic strip test (FICT) was developed for the rapid, sensitive, and quantitative detection of porcine reproductive and respiratory syndrome virus (PRRSV) antibodies at the pen-side. The assay was based on the formation of a sandwich immune-complex (anti-pig IgG-PRRSV antibodies-NSP7/N), which was validated by a comparison with IDEXX-ELISA using 3325 clinical specimens. The diagnostic specificity, sensitivity, and accuracy of FICT were 97.28, 93.41, and 94.95%, respectively. FICT showed a good correlation with the virus neutralization assay. Overall, a promising pen-side diagnostic tool was developed for the rapid and quantitative detection of PRRSV antibodies within 15 min.

Detection of VTe-producing E coli using PCR method (PCR 기법 이용 VTe 분비 대장균 검출)

  • Yoon, Soon-seek;Park, Nam-yong;Lim, Jeong-taek
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.3
    • /
    • pp.607-614
    • /
    • 1996
  • Several methods for rapid and accurate detection of VTe-producing E coli were established. These methods contain beta-glucuronidase-secretion test, beta-haemolysis-production test in blood agar, verocytotoxicity test, and PCR. All of the VTe-producing strains made beta-haemolysis on 5% sheep blood agar. VTe-producing strains secreted beta-glucuronidase whereas 0157:H7 strains producing VTI or VTII did not secrete that enzyme. Verocytotoxicity test was established for rapid diagnosis. VTe detection was rapider in Vero cell suspension than Vero cell monolayer. In PCR, there was a positive result only in VTe-producing E coli, not in VTI or VTII-producing E coli. In this experiment, 165 strains of E coli were islated from feces or intestinal contents of post-weaning piglets showing nervous sign or diarrhea. And 20 strains of E coli that produced VTe were selected by verocytotoxicity test and PCR. According to these experiments, there was a direct correlation between verocytotoxicity test and PCR. And verocytotoxicity test is recommended as a routine diagnostic method and PCR does as a accurate diagnostic method to detect VTe-producing E coli.

  • PDF

Development of Immunochromatography Strip-Test Using Nanocolloidal Gold-Antibody Probe for the Rapid Detection of Aflatoxin B1 in Grain and Feed Samples

  • Shim, Won-Bo;Yang, Zheng-You;Kim, Jung-Sook;Kim, Ji-Young;Kang, Sung-Jo;Woo, Gun-Jo;Chung, Young-Chul;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.10
    • /
    • pp.1629-1637
    • /
    • 2007
  • An immunochromatography (ICG) strip test using a nanocolloidal gold-antibody probe was developed and optimized for the rapid detection of aflatoxin B1 (AFB1). A monoclonal antibody specific to AFB1 was produced from the cloned hybridoma cell (AF78), coupled with nanocolloidal gold, and distributed on the conjugate pad of the ICG strip test. The visual detection limit of the ICG strip test was 0.5 ng/ml, and this method showed a cross-reaction to aflatoxin B2, G1, and G2. In total, 172 grain and feed samples were collected and analyzed by both the ICG strip test and HPLC. The results of the ICG strip test showed a good agreement with those obtained by HPLC. These results indicated that the ICG strip test has a potential use as a rapid and cost-effective screening tool for the determination of AFB1 in real samples and could be applied to the preliminary screening of mycotoxin in food and agricultural products, generating results within 15 min without complicated steps.