A New Random PWM Technique for Conducted-EMI Mitigation on Cuk Converter

  • Krishnakumar, C.;Muhilan, P.;Sathiskumar, M.;Sakthivel, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.916-924
    • /
    • 2015
  • Electromagnetic Interference (EMI) is a system to system or environment to system phenomenon. The literature survey proved that the Randomized Pulse Width Modulation (RPWM) technique is a promising technique to reduce EMI. A new Constant Trailing Edge, Randomized Pulse Width Modulation (CTERPWM) technique is proposed in this paper. The effect of the proposed RPWM technique for mitigation of conducted-EMI on Cuk converter operating in Continuous Conduction Mode (CCM) is simulated and tested. In this paper, the analytical expressions for the Power Spectral Density (PSD) are derived for the proposed RPWM technique and are validated by experimental measurements. The effectiveness of the proposed RPWM technique on the mitigation of conducted-EMI is verified comparing simulation and experimental results and it is identified that both the results are almost similar with allowable experimental deviations. The comparative investigation proves that the proposed RPWM technique can mitigate and spread the dominant peaks of conducted-EMI over the complete spectrum for the Cuk converter. Based on the investigation the CTERPWM technique is recommended for adoption.

LF2407 DSP제어기를 사용한 혼합형 랜덤 펄스폭 변조(HRPWM)기법 (A Hybrid Random Pulse Width Modulation(HRPWM) Technique Using LF2407 DSP Controller)

  • 김기선;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.101-105
    • /
    • 2004
  • 본 연구에서는 LF2407 DSP제어기를 사용한 혼합형 랜덤 펄스폭 변조기법(HRPWM : Hybrid Random PWM)을 제안하였다. 제안된 HRPWM은 PRBS (Pseudo-Random Binary Sequence)로 동작하는 시프트 레지스터의 lead-lag 랜덤 비트를 사용한다는 점에서 종전의 방법과 동일하다. 그러나 Lead-Lag 랜덤 비트와 논리적인 비교를 하기 위해 고정 주파수의 캐리어를 사용 하지 않고 랜덤 주파수의 삼각파 캐리어를 이용한다는 점이 종전의 방법과 다르다. LF2407 DSP에 의하여 랜덤 수 및 PRBS 그리고 3상 기준 정현파를 실시간으로 발생하며, DSP외부의 주파수 변조기 MAX038에 의하여 랜덤 주파수의 캐리어를 발생한다. 제안된 기법을 LF2407기반의 3상 유도모터 구동장치에 적용한 결과, 모터 전류파형은 종전의 방법과 유사한 파형을 유지하면서도 모터 전압 및 전류의 고조파 스펙트럼은 광대역 주파수로 분포시킬 수 있었다.

  • PDF

로봇구동용 직류전동기의 동기화 구현 (Synchronization of Robot driving DC motor)

  • 엄한성;안병원;김현수;박영산;배철오
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.325-328
    • /
    • 2003
  • 본 연구는 인터넷을 통해서 실시간으로 전달되는 속도지령에 대해서 원거리에 위치한 로봇구동용 DC 전동기 동기화 제어에 관한 연구이다. 두 대의 DC 전동기 구동시스템에서 80C196KC $\mu$-Processor에 의해서 DC 전동기에 인가되는 PWM전압과 회전수의 관계로 PID제어기를 설계하고 임의의 속도(위치) 지령에 대해서 두 대의 전동기가 빠른 시간에 동기화가 될 수 있게 하였다. 또, 호환성이 뛰어난 Java 플랫폼을 기반의 Java Applet과 Servlet을 연동시켜 보안을 유지하면 인터넷 상에서 전동기를 실시간으로 제어하고, 속도를 모니터링 할 수 있게 하였다.

  • PDF

3배수차 고주파 주입에 의한 PWM인버터의 출력특성개선 (Improvement of Output Characteristics by Triplen-Harmonics Injection in PWM Inverters)

  • 이선호;조지원;김호진;신우석;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.295-300
    • /
    • 1990
  • This paper describes a new method to increase the fundamental output of PWM inverter by adding all triplen-harmonics to sinusoidal reference wave. As a result, the amplitude of the fundamental component is increased upto 21 percent compared with the conventional SPWM method, and hence the conversion efficiency of dc link is higher. Also as the commutation number of the inverter is decreased to two-thirds, the heating of the switch devices is reduced. In addition random carrier modulation is adopted to lower the acoustic noise at given frequency modulation index.

  • PDF

DSP기반의 케리어 변조 Random PWM 기법 (A DSP based Randomly Modulated Carrier PWM Scheme)

  • 김회근;임영철;나석환;김영철;정영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.150-156
    • /
    • 2001
  • This paper describes an implementation of the DSP(Digital Signal Processor) based triangular carrier frequency modulated RPWM inverter drive system. The power spectrum of the noise emitted from the induction motor was measured in the anechoic chamber. The analysis of the sources for the acoustic noise and the effects of the noise reduction are confirmed by the measured spectra of the noise. Real-time RPWM along with the speed control was achieved by high speed DSP. By changing the center frequency and the bandwidth of the carrier, the proposed real-time RPWM scheme can be used as an efficient switching frequency band acoustic noise reduction method for the inverter drive system with variant load conditions.

  • PDF

가우스 잡음을 고려한 비선형 펄스 변조 시스템의 안정도 분석 (Stability Analysis of Nonlinear Pulse-Modulated System Subject to Gaussian Noise)

  • 강영채
    • 대한전자공학회논문지
    • /
    • 제19권6호
    • /
    • pp.67-79
    • /
    • 1982
  • 가우스 잡음의 출현시 PWM 시스템의 안정도가 연구되었다. 일반 시스템은 종래의 서술 함수 방법을 이용할 때 비선형 소자와 선형 소자로 나누어진다. 등가 어드미턴스 개념이 이 시스템의 비선형 소자의 전달 특성을 구하는데 사용되었다. 이 논문에서는 가우스 잡음만이 존재하는 경우 자기 발진 조건이 유도되었고 그 결과를 컴퓨터 시뮬레이션으로 분석하였다. The stability of general pulse-width modulation system with Gaussian random disturbance was discussed . General system is divided into nonlinear and linear elements using the conventional describing function method. The concept of the equivalent admittance was used to find the transfer characteristic of the nonlinear element of the system. In this paper the self-sustained oscillation condition in the autonomous system was derived and the results was analyzed with computer simulation.

  • PDF

캐리어 주파수 변조에 의한 실시간 RPWM 구동장치 (Real Time RPWM Drive System by Carrier Frequency Modulation Technique)

  • 나석환;최창률;양승학;임영철;김광헌;박종건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2058-2061
    • /
    • 1997
  • A main research topic in PWM inverter drive system is to reduce the generated acoustic noise. One method to reduce the acoustic noise is to cause the switching pattern to be random. This RPWM(Random Pulse Width Modulation) technique for voltage controlled inverters is a kind of good solutions for reduction of acoustic noise and suppression of vibration. This paper describes a carrier frequency modulated real-time RPWM inverter. Changing the carrier frequency randomly, the power spectrum of tile acoustic noise was spread over the wide-band area. And experimental results showed that emitted noise is much more comportable and less annoying

  • PDF

RPWM 기법을 이용한 능동클램프 ZVS 플라이백 컨버터 전도노이즈저감 (Conducted Noise Reduction in Active clamp ZVS flyback converter using Random Pulse Width Modulation)

  • 김영규;최태영;원충연;김재문;김규식;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.498-501
    • /
    • 2002
  • In the conventional PWM converter, high-frequency switching techniques was used for high-density of energy, but occurred a lot of problems such as switching losses, switching voltage/current stresses, EMI(Electromgnetic Interference) and so on. To overcome these problems, various soft switching techniques have been presented. However these techniques are focused on reducing switching losses and voltage/current stresses . The simulation and experimental results are shown that the active clamp ZVS flyback converter with the proposed RPWM(Random Pulse Width Modulation) technique reduces the conducted noise.

  • PDF

멀티 영벡터를 갖는 2상 랜덤 중앙 분포 변조기법의 파워 스펙트럼 (Power Spectrum of 2 Phase Random Centered Distribution Modulation Scheme with Multi Zero Vector)

  • 오승열;김정근;임영철;양형렬;정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.21-30
    • /
    • 2003
  • 본 연구에서는 변조지수 M이 큰 영역에서는 고조파 스펙트럼의 광대역화 효과가 저하되는 2상 랜덤 중앙 정렬 변조기법 (Random Centered Distribution PWM : RCD)기법의 문제점을 해결하고자 멀티 영벡터 2상 RCD (Multi Zero Vector RCD : MZRCD) 변조기법을 제안하였다. 제안된 2상 MZRCD기법은 변조지수 M=0.7을 기준으로 하여 M이 0.7보다 큰 영역에서는 영벡터를 V(111)로 선택하고, 0.7보다 작은 영역에서는 V(000)을 선택한다. 제안된 방법을 유도모터 구동시스템에 적용해 본 결과, M이 0.7이상인 영역에서도 모터의 전압/전류 및 소음 스펙트럼의 광대역화 특성이 종전의 방법에 비하여 우수함을 확인할 수 있었다.

  • PDF

Random PWM 기법에 의한 전도노이즈 (Conducted Noise Reduction in Random Pulse Width Modulation)

  • 정동효;김상남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.98-101
    • /
    • 2002
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300V/1kW with 5%${\sim}$30% white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with USN. which are connected to the spectrum analyzer respectively.

  • PDF