• Title/Summary/Keyword: ramp

Search Result 860, Processing Time 0.028 seconds

High Performance Current-Mode DC-DC Boost Converter in BiCMOS Integrated Circuits

  • Lee, Chan-Soo;Kim, Eui-Jin;Gendensuren, Munkhsuld;Kim, Nam-Soo;Na, Kee-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.6
    • /
    • pp.262-266
    • /
    • 2011
  • A simulation study of a current-mode direct current (DC)-DC boost converter is presented in this paper. This converter, with a fully-integrated power module, is implemented by using bipolar complementary metal-oxide semiconductor (BiCMOS) technology. The current-sensing circuit has an op-amp to achieve high accuracy. With the sense metal-oxide semiconductor field-effect transistor (MOSFET) in the current sensor, the sensed inductor current with the internal ramp signal can be used for feedback control. In addition, BiCMOS technology is applied to the converter, for accurate current sensing and low power consumption. The DC-DC converter is designed with a standard 0.35 ${\mu}m$ BiCMOS process. The off-chip inductor-capacitor (LC) filter is operated with an inductance of 1 mH and a capacitance of 12.5 nF. Simulation results show the high performance of the current-sensing circuit and the validity of the BiCMOS converter. The output voltage is found to be 4.1 V with a ripple ratio of 1.5% at the duty ratio of 0.3. The sensing current is measured to be within 1 mA and follows to fit the order of the aspect ratio, between sensing and power FET.

Legibility Change of Commercial Vehicles Equipped with the Rear Lighting System (화물자동차 보조 후미등화장치 설치에 따른 운전자 시인성 변화)

  • Cho, Seung Jin;Lee, Chang Hee;Kum, Ki Jung
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.111-122
    • /
    • 2013
  • PURPOSES : The purpose of this system (Rear Lighting System) is to provide illumination for the driver to operate the commercial vehicle safely after dark in highway, to increase the conspicuity of the vehicle, and especially be suggesting the finest observable improvement method, depending on color and pattern of rear lighting system of truck for midnight highway traffic. METHODS : Rear lightning system as an improving way for forward commercial vehicles lighting the securing sight from human factors and the surrounding environment in midnight driving. For this one, basic materials were collected from the data analysis about many types of problems, and filed investigation for establishing Driving Simulator. also taking statistic test to human volunteers after finding recognizable distance of them. RESULTS : As a result, color with the highest visuality is amber followed by green-red-blue as in order for all road types. Especially almost no difference is found between red and green, also when the light is turn off, recognizable distances is wide difference compared to turn on the light. One more thing about study per pattern, upper and entire lighting have similar recognizable distances, but under lighting shows short distance with difficulty securing sight from medians. And straight section shows similar recognizable distances. By finding visuality improvement method depending on color and pattern of supplement taillight, it is expected to suggest quantitative judgement standard for introducing regulation and improvement of supplement taillight. CONCLUSIONS : Night time vehicle conspicuity to the rear is provided by rear position lamps. this study is showed that the color of light ramp is not important to be safe driving, most important is to turn on the light, recognizable distances is big different compared to turn off the rear light, so when the drivng dark in highway, have to turn on the light for reducing risk.

FUEL PERFORMANCE CODE COSMOS FOR ANALYSIS OF LWR UO2 AND MOX FUEL

  • Lee, Byung-Ho;Koo, Yang-Hyun;Oh, Jae-Yong;Cheon, Jin-Sik;Tahk, Young-Wook;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.499-508
    • /
    • 2011
  • The paper briefs a fuel performance code, COSMOS, which can be utilized for an analysis of the thermal behavior and fission gas release of fuel, up to a high burnup. Of particular concern are the models for the fuel thermal conductivity, the fission gas release, and the cladding corrosion and creep in $UO_2$ fuel. In addition, the code was developed so as to consider the inhomogeneity of MOX fuel, which requires restructuring the thermal conductivity and fission gas release models. These improvements enhanced COSMOS's precision for predicting the in-pile behavior of MOX fuel. The COSMOS code also extends its applicability to the instrumented fuel test in a research reactor. The various in-pile test results were analyzed and compared with the code's prediction. The database consists of the $UO_2$ irradiation test up to an ultra-high burnup, power ramp test of MOX fuel, and instrumented MOX fuel test in a research reactor after base irradiation in a commercial reactor. The comparisons demonstrated that the COSMOS code predicted the in-pile behaviors well, such as the fuel temperature, rod internal pressure, fission gas release, and cladding properties of MOX and $UO_2$ fuel. This sufficient accuracy reveals that the COSMOS can be utilized by both fuel vendors for fuel design, and license organizations for an understanding of fuel in-pile behaviors.

Operation Analysis of Downstream Intersections at Urban Freeway Off-ramps (도시고속도로 진출램프 하류부교차로 운영 분석 (중동 IC 사례 분석을 중심으로))

  • Jeon, Jae-Hyeon;Kim, Young-Chan;Jeoung, Young-Je
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.4
    • /
    • pp.7-16
    • /
    • 2008
  • Severe congestion is happening at urban freeway off-ramps in Seoul. Major causes of congestion at off-ramps are a shortage of capacity and inefficient signal operations at the downstream intersection at off-ramps. It is necessary to control congestion by improving design or operations in the downstream intersection. In this study, the authors analyzed the case of the Jungdong interchange that was improved for design in the downstream intersection. When a freeway and an arterial road cross, diamond interchanges are usually selected with a single-point urban interchange (SPUI) as an alternative. To compare the effectiveness of a diamond interchange with a SPUI, the authors applied these two configurations to the Jungdong interchange using a simulation. The result of the analysis shows that congestion at off-ramps in diamond interchanges can be reduced by improving signal operations such as the application of "4 phase with overlaps" and that diamond interchanges are more efficient than a SPUI with a frontage road. Efficient operation of the downstream intersection by these findings can minimize congestion of not only the downstream intersection but also the freeway mainline.

Preliminary Study for Risk Assessment Estimation of Urban Underground Connect Section Using VISSIM : Comparison of Characteristics Based on Diverge/Merge (VISSIM을 활용한 도심 지하도로 연결로 위험도 산정을 위한 기초연구 : 분·합류부 기준 특성 비교)

  • Park, Sang Hyun;Lee, Jin Kak;Yang, Choong Heon;Kim, Jin Guk
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.5
    • /
    • pp.59-74
    • /
    • 2021
  • The domestic road space is reaching the limit of planar space distribution, and Increasingly, the importance of three-dimensional space distribution through the development of underground space. therefore, In this study, a study was conducted on a traffic control method that can safely induce two different traffic flows in the connection between the ground road and the underground road. Through VISSIM, we calculated the appropriate amount of outflow and inflow traffic compared to the capacity of the main line when there is a Merge/Diverge section in the underground road. and Through the analysis of the number of conflicts, the appropriate traffic control level for safety in the underground, A basic study was conducted on the level of risk in the underpass according to the level of delay in the ground part through the analysis of the delay scenario of the ground road.

An Analysis on the Characteristics of Barrier Free Certifications in Elementary School (초등학교시설 장애물 없는 생활환경 인증 실태분석 연구)

  • Lee, Jeong-Soo;Oh, Young-Sook;Eun, Dong-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.26-35
    • /
    • 2019
  • The purpose s of this study is to verify the status of barrier-free certification in an elementary school. To achieve this, the architectural characteristics of an elementary school and proposed opinions about the process of barrier-free certification were analyzed. The results of this study are as follows: (1) barrier-free certification in an elementary school is valid for inclusive education and accessibility for students with disabilities. (2) Regarding the school district and safe accessibility for the school, it is necessary to minimize the differences in land levels around the school. (3) Considering the opinions on intermediate facilities from the road to the main entrance, it is necessary to set the finish level of the first floor and to minimize the establishment of ramp or steps to prevent the backflow of rainfall.

A Study on the Characteristics of Temperature Distribution Related to Geometry of Tube in Hydrogen Storage Vessel (수소 저장용 탱크의 튜브 형상에 따른 온도분포 특성에 대한 수치해석 연구)

  • OH, SEUNG JUN;YOON, JEONG HWAN;JEON, KYUNG SOOK;KIM, JAE KYU;PARK, JOON HONG;CHOI, JEONGJU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.205-211
    • /
    • 2021
  • Recently, it is necessary for study on renewable energy due to environmental pollution and fossil fuel depletion. Therefore, in this study, the filling temperature according to the nozzle geometry was evaluated based on the limit temperature specified in SAEJ2601 for charging hydrogen, a new energy. There are three types of nozzles, normal, angle and round, fixed the average pressure ramp rate at 52.5 MPa/min, and the injection temperature was set at 293.4 K. As a result, the lowest temperature distribution was found in the round type, although the final temperature did not differ significantly in the three types of nozzles. In addition, Pearson's coefficient was calculated to correlate the mass flow rate with the heat transfer rate at the inner liner wall, which resulted in a strong linear relationship of 0.98 or higher.

Flow Characteristics in a Supersonic Combustor with a Configuration of a Cavity (초음속 연소기 내 공동 형상에 따른 유동 특성)

  • Yim, Geon Wook;Roh, Tae-Seong;Lee, Hyoung Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.2
    • /
    • pp.1-11
    • /
    • 2021
  • The cavity inside the combustor increases the mixing efficiency of fuel and air by inducing a oscillation of the flow and the recirculation area with a low speed, and enables continuous combustion by maintaining the flame. In this study, the characteristics of the internal flow by change in the shape parameters of the cavity were analyzed through experiments and two-dimensional computational analysis. It was observed that the flow in the supersonic combustor was greatly influenced by various shape parameters of cavity besides L/D. Even with the same L/D, it was confirmed that the flow type varies depending on the depth of the cavity, either open or closed type, and the aft ramp angle of the cavity and the height of the combustor also affect the flow characteristics. As a result, the change in the shape parameters of the cavity had a great influence on the total pressure loss.

A Study on the Evacuation Performance Analysis Model Considering Clustering Types at the Fire Event in Geriatric Hospital (노인 요양병원에서 화재 시 군집유형에 따른 피난 성능 분석 모델에 관한 연구)

  • Kim, Mijung;Kweon, Jihoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.1
    • /
    • pp.63-74
    • /
    • 2022
  • Purpose: The purpose of this study is to present an evacuation performance analysis model that can derive vulnerable evacuation spaces with considering the movement behavior as per the elderly groups in the event of a fire in a geriatric hospital. Methods: The evacuation characteristics of geriatric hospital users were investigated through the review of precedent studies. First, the occupant conditions and the evacuation scenario were set to analyze a study target hospital. Then, the evacuation simulation was carried out considering the group types and the density of each group. Finally, an evacuation performance analysis model according to the group type was presented based on the simulation results. Results: The results of this study are as follows: (1) The evacuation performance according to the group type is to be clarified through the suggested study model. (2) It is necessary to secure a ramp or an emergency elevator to distribute the evacuation personnel at the design stage because congestion occurs due to collisions between evacuees on the stairs and delays the evacuation time. (3) It is necessary to consider the evacuation stairs and openings of sufficient size by analyzing the frequency of congestion occurrence and the escape routes of occupants in advance to identify the space where the evacuation flow overlaps. Implications: It is expected that the study result is to be used as primary data for studies that consider the elderly and clustering evacuation behavior in the event of a fire in a geriatric hospital.

Identification of Evacuation Route Planning Elements for the Disabled by Considering Universal Design - A Study on the Welfare Center for the Disabled - (유니버설 디자인을 고려한 지체장애인 대피경로 계획요소 규명 - 장애인 종합복지관 시설을 대상으로 -)

  • Jung, Tae-Ho;Yang, Won-Jik
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.672-686
    • /
    • 2022
  • Purpose: This study derived the planning factors affecting the evacuation route of facilities for the disabled and to identify the planning factors that affect each facility. Method: The PLS(Partial Least Square)Regression analysis was used to solve the problem of multicollinearity and number of samples. Result: As a result of analysis, The most important planning elements for each facility were derived as door: closing time (1.131), corridor: ramp for wheelchairs (1.227), stairs: emergency lighting for stairs (1.117), and evacuation space: evacuation space convenience facilities (1.106). Conclusion: In order to plan an effective evacuation route for the disabled, a universal design should be applied to consider the perception, needs, and satisfaction of the disabled, rather than a comprehensive reflection.