• 제목/요약/키워드: radionuclide detection

검색결과 48건 처리시간 0.018초

Separation and Determination of Citric Acid by Ion Chromatography in Radioactive Concrete Waste

  • Hyejin Cho;Jai Il Park;Tae-Hong Park;Hye-Ryun Cho
    • 방사성폐기물학회지
    • /
    • 제22권1호
    • /
    • pp.27-35
    • /
    • 2024
  • During the dismantling of nuclear facilities, a large quantity of radioactive concrete is generated and chelating agents are required for the decontamination process. However, disposing of environmentally persistent chelated wastes without eliminating the chelating agents might increase the rate of radionuclide migration. This paper reports a rapid and straightforward ion chromatography method for the quantification of citric acid (CA), a commonly used chelating agent. The findings demonstrate acceptable recovery yields, linearities, and reproducibilities of the simulated samples, confirming the validity of the proposed method. The selectivity of the proposed method was confirmed by effectively separating CA from gluconic acid, a common constituent in concretes. The limits of detection and quantification of the method were 0.679 and 2.059 mg·L-1, respectively, while the recovery yield, indicative of the consistency between theoretical and experimental concentrations, was 85%. The method was also employed for the quantification of CA in a real concrete sample. These results highlight the potential of this approach for CA detection in radioactive concrete waste, as well as in other types of nuclear wastes.

자발성 두개강내 저뇌압증 환자의 뇌척수액 누출부위 진단에 방사성동위원소 뇌조조영술의 유효성: 예비결과 보고 (Effectiveness of Radionuclide Cisternography to Detect the Leakage Site of CSF in Spontaneous Intracranial Hypotension; Preliminary Report)

  • 김성민;김재문
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권3호
    • /
    • pp.148-154
    • /
    • 2006
  • 목적 : 방사성동위원소 뇌조조영술은 자발성 두개강내 저뇌압증이 의심되는 환자에서 뇌척수액의 누출을 진단하는데 유용한 검사이지만, 뇌척수액의 누출 부위를 증명하지 못하는 경우가 있다. 본 연구의 목적은 방사성동위원소 뇌조조영술의 검사 방법을 변화함으로써 뇌척수액 누출 부위의 진단율을 향상시키고, 검사 소요시간을 단축할 수 있는지 알아 보고자 한다. 대상 및 방법 : 자발성 두개강내 저뇌압증으로 진단되어 방사성동위원소 뇌조조영술을 시행한 7명의 환자(평균 나이=$38{\pm}8$세, 남자 2명, 여자 5명), 8회 검사를 대상으로 하였다. 모든 환자들은 자주막하강에 $^{99m}Tc$-DTPA 185-222 MBq을 투여한 후 10분, 30분, 1시간, 2시간, 4시간 그리고 6시간에 방광을 포함하는 요추부부터 두부까지의 영상을 얻었다. 그리고 영상시간에 따라 뇌척수액의 누출과 방광의 방사능 조기 출현을 평가하였다. 결과: 방사성동위원소 뇌조조영술을 통해 8예 모두에서 뇌척수액의 누출 부위를 확인할 수 있었다. 뇌척수액의 누출 부위는 경흉추 경계부(cervico-thoracic junction)에서 3예, 경흉추 경계부와 C1-2에서 2예, 경흉추 경계부와 흉추부, 흉요추부 여러 곳 그리고 요추부가 각각 1예씩 이었다. 모든 예에서 1시간까지의 영상을 통해 모든 예에서 뇌척수액의 누출 부위를 발견할 수 있었으며, 모두 두 곳 이상에서 누출이 있었다. 이 중 경흉추 경계부를 포함하는 경우가 5예였다. 지연 영상에서 뇌척수액의 누출 부위가 추가로 발견된 경우는 단 1예 뿐 이었다. 조기 방광방사능 출현은 6예에서 관찰되었으며, 모두 뇌척수액 유출부위가 더 먼저 관찰되었다. 결론: 방사성동위원소 뇌조조영술은 자발성 두개강내 저뇌압증 환자에서 뇌척수액의 누출 부위를 확인하는데 매우 예민한 검사이며, 검사법을 변형함으로써 뇌척수액의 누출 부위를 발견하는 빈도를 향상시키고, 검사시간을 단축할 수 있을 것으로 기대된다.

Multigrid Wavelet-Based Natural Pixel Method for Image Reconstruction in Emission Computed Tomography

  • Chang je park;Park, Jeong hwan;Cho, Nam-Zin
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.705-710
    • /
    • 1998
  • We describe a multigrid wavelet-based natural pixel (WNP) method for image reconstruction in emission computed tomography (ECT). The ECT is used to identify the tagged radioactive material's position in the body for detection of abnormal tissue such as tumor or cancer, as in SPECT and PET. With ECT methodology in parallel beam mode, we formulate a matrix-based reconstruction method for radionuclide sources in the human body. The resulting matrix for a practical problem is very large and nearly singular. To overcome this ill-conditioning, wavelet transform is considered in this study. Wavelets have inherent de-noising and multiscale resolution properties. Therefore, the multigrid wavelet-based natural pixel (WNP) method is very efficient to reconstruct image from projection data that is noisy and incomplete. We test this multigrid wavelet natural pixel (WNP) reconstruction method with the MCNP generated projection data for diagnosis of the simulated cancerous tumor.

  • PDF

암캐에서 유전 종양의 핵의학적 진단 (Scintigraphic Detection of Mammary Tumor in a Bitch)

  • 강성수;김명환;배춘식;최석화
    • 한국임상수의학회지
    • /
    • 제18권4호
    • /
    • pp.469-473
    • /
    • 2001
  • A 12-year-old bitch, Yorkshire terrier, was admitted to the Chungbuk National University animal hospital with draining from mammary masses in the left and right mammary glands. She was involved in the mammary masses, suffering bilateral inguinal hernia. Physical examination during the hospitalization demonstrated the masses in right (3 cm) and left (1.5 cm) mammary glands. Blood pool images didn\`t show the subtle increase in blood flow to the inguinal hernia, and the increase of radionuclide distribution to the mammary gland on the soft tissue phase. However, delayed bone images showed a very focal lesion in the right mammary gland. These findings were confirmed on a subsequent biopsy, which also revealed adenocarcinoma with areas of malignant new bone formation. We present a case of primary mammary adenocarcinoma with $^{99m}Tc-MDP$ activity relative to normal bone. Tumor in the bitch demonstrates malignant new bone formation as the likely mechanism for the marked radiotracer avidity.

  • PDF

Investigation of a blind-deconvolution framework after noise reduction using a gamma camera in nuclear medicine imaging

  • Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2594-2600
    • /
    • 2020
  • A gamma camera system using radionuclide has a functional imaging technique and is frequently used in the field of nuclear medicine. In the gamma camera, it is extremely important to improve the image quality to ensure accurate detection of diseases. In this study, we designed a blind-deconvolution framework after a noise-reduction algorithm based on a non-local mean, which has been shown to outperform conventional methodologies with regard to the gamma camera system. For this purpose, we performed a simulation using the Monte Carlo method and conducted an experiment. The image performance was evaluated by visual assessment and according to the intensity profile, and a quantitative evaluation using a normalized noise-power spectrum was performed on the acquired image and the blind-deconvolution image after noise reduction. The result indicates an improvement in image performance for gamma camera images when our proposed algorithm is used.

Radiolabeled Benzamide Derivatives for Development of Malignant Melanoma Imaging Agents

  • Ayoung Pyo;Boreum Song;Heejung Kim;Dong-Yeon Kim
    • 대한방사성의약품학회지
    • /
    • 제8권1호
    • /
    • pp.25-32
    • /
    • 2022
  • Malignant melanoma has an aggressive nature and high metastatic potential that result in one of the highest cancer mortality rates. Over the past three decades, primary and metastatic melanoma incidence has rapidly increased. The recent advances in diagnostic technology have shown promise, but there is still an enormous need for specific detection methods to diagnose malignant melanoma. Positron emission tomography can visualize a particular biomarker of malignant melanoma and promise a noninvasive image of micrometastases. However, the development of PET radiopharmaceuticals remains necessary for diagnosing malignant melanoma by using positron emission tomography. In this review, the history and a general overview of PET radionuclide labeled benzamide derivatives, including their radiosynthesis, in vivo characterization, and evaluation, are provided as imaging agents for malignant melanoma.

Long term activity measurement of the primary circuit water on the LVR-15 research reactor

  • Ladislav Viererbl;Vit Klupak;Hana Assmann Vratislavska
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1250-1253
    • /
    • 2024
  • Activity measurement of the primary circuit water of fission reactors is one method that can provide early detection of a damaged fuel assembly in the reactor core. This is an important aspect in the safe operation of the reactor and for radiation protection of staff. Radionuclides in the primary circuit water are produced by the activation of stable nuclides and the fission of fissile nuclides, mainly the isotope 235U. In the LVR-15 research reactor, measurement of the activity of the primary circuit water has been regularly undertaken since 1996. A water sample is taken from the primary circuit every week and the activities are measured four days later using gamma spectrometry. The results of these long-term measurements from 1996 to 2022 are presented. The activity time dependences of the individual radionuclides are discussed in relation to fuel assembly damage and for events connected to contamination of the water by objects inserted into the primary circuit during experiments carried out near the reactor core.

핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정 (Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring)

  • 김종수;윤석철;신장수;곽은호;최종서
    • Journal of Radiation Protection and Research
    • /
    • 제22권2호
    • /
    • pp.111-117
    • /
    • 1997
  • 최근 포괄적 핵실험금지조약 (Comprehensive Test Ban Traety : CTBT)의 체결은 전세계적으로 핵활동 감시 네트워크를 구축하는 것이다. 핵실험금지 위원회의 전문가들은 대기 방사성핵종의 측정을 핵실험 감시에 필수적인 요소로 제안하였으며, 이에 따른 기술적 요구사항을 제시하였다. 본 연구는 이를 근거로 핵활동으로부터 생성된 핵분열생성물을 검출하기 위하여 고성능 공기채집장치(High Volume Air Sampler: HVAS)와 여과지 압축기 그리고 고순도 게르마늄 반도체검출기(HPGe)로 대기 입자 방사성핵종 측정시스템을 구성하였다. 조속한 시일 내에 탐지와 최적의 측정 조건으로 본 시스템을 운영하기 위하여 CTBT 감시 전략에서 주요 핵종들에 대한 최소검출 방사능 농도(Minimum Detectable Concentration : MDC)를 decay time, counting time 그리고 sampler volumetric flow rate 등을 고려하여 결정하였다. 그 결과 각각 $10{\pm}$2h, $20{\pm}$2h, $850{\pm}50m^3$//h 정도로 선정하였다. 감마선 스펙트럼 분석에서 $^{212}Pb$ 방사능 농도의 변화는 Compton continuum의 baseline에 영향을 미치게 되므로 이에 기인한 MDC 관계식을 도출하였다. 이들 결과는 CTBT 감시 전략에 실제적인 도구로 사용될 수 있을 것으로 사료된다.

  • PDF

원자력시설 해체 시 특성평가를 위한 표면오염 탐지 이중구조 고분자 복합체의 제조 (Preparation of polymeric composites for surface contamination measurement in order to characterize nuclear facilities decommissioning)

  • 한명진;서범경;우주희;이근우
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.97-104
    • /
    • 2004
  • 원자력시설의 해체를 위한 표면오염도를 측정함에 있어 기존의 일반적인 단일층 함침 복합체의 단점을 개선한 치밀한 구조의 지지층 위에 활성층의 2차막을 도포 하여 제조된 이중 구조의 고분자 복합체를 제조하고 이들의 특성을 분석하였다. 세륨활성화된 이트리움실리케이트(Cerium-activated ytttrium silicate, CAYS)를 함침시킨 폴리설폰 이중구조 필름은 1차 지지층으로서 폴리설폰 (polysulfone, PSF)과 메틸렌클로라이드 (methylene chloride, MC)로 이루어진 2액용액을 유리판 위에 제막하고 증발을 통해 MC를 제거하여 고분자의 유리화(vitrification)를 통해 치밀한 구조로 고형화하도록 하였다. 고형화한 1차층 위에 CAYS 와 용매로 이루어진 2차 제막용액을 덧붙여 도포하고 물에 침지시키거나 대기방치를 통해 고형화시켰다. 이렇게 이루어진 2중 구조의 무기섬광체 함침 복합체 필름은 2차 제막층에 손가락 형태의 큰 기공이 생성되었으며, 1차층과 2차층이 완전히 결합되어 있어 우수한 기계적 물성을 나타냈다. 한편, 섬광체인 CAYS를 첨가하였을 때 필름에 생성되는 은 기공의 형성이 증대되는 특성을 보였으며, 용매의 증발에 의해 고형화 된 필름은 치밀한 구조의 형상을 보였다. 제조된 필름들은 방사성핵종의 탐지에 있어 신뢰할만한 탐지 결과를 보였다.

  • PDF

물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (I) 미국환경보호청(Envirionmental Protection Agency)의 먹는 물 방사성물질 관리와 분석법에 관한 고찰 (Study on Radioactive Material Management Plan and Environmental Analysis of Water (I) Study of Radioactive Substances in Water Management and Analysis to Eat of the US Environmental Protection Agency (Envirionmental Protection Agency))

  • 허재;김정민;민혜림;한성규;임현종;조한별;노영훈;이호선;박민석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.163-170
    • /
    • 2015
  • 후쿠시마 원전 사고 이후 수질 내 방사성 오염에 대한 국민들의 관심이 크게 높아졌다. 이에 따라 해외에서는 인체에 영향을 줄 수 있는 먹는 물 속 방사성물질 분석과 관리에 관한 연구가 활발히 진행되었다. 그리고 국내에서도 환경부령 제553호로 "먹는 물 수질기준 및 검사 등에 관한 규칙" 제 2조 수질기준을 규정하여 먹는 물 속 방사성농도의 감시를 하고 있으며 최근에는 염지하수 뿐 아니라 공공수역까지 범위를 확대하여 효율적인 관리를 하고 있다. 본 연구에서는 현재 국내에서 시행되고 있는 먹는 물 관리 시스템이 좀 더 나은 관리 및 운영이 될 수 있도록 미국 EPA(환경보호청) 사례를 분석해 보고자 하였다. 그 결과 미국 EPA(환경보호청)에서는 조사핵종을 선정할 시에 자국의 지질화학적인 조사와 원자력 발전소 보유현황 그리고 인공방사성 핵종의 사용유무 등을 조사하고 추가적으로 인간이 연간 먹는 물로 인하여 피폭 받을 수 있는 최대오염농도(0.1 mSv/y)를 고려함으로써 ${\alpha}$ 방출체, ${\beta}/{\gamma}$ 방출체, 라돈 및 우라늄으로 구분지어 핵종을 선정한 후 관리하고 있다. 조사주기 면에서는 미국 EPA(환경보호청)의 MCL(Maximum Contaminant Level - 최대오염농도)과 RDL(Required Detection Level - 검출하한치) 이라는 개념을 정립함으로써 그 이상의 농도가 검출되지 않도록 유지 및 관리를 하고 있다. 여기서 최대오염농도는 권고된 수치 이상의 농도가 측정 될 시에 특별한 관리조치와 해결방안이 제시되어야 하는 반면 검출하한치는 이 수치 이하로 측정된 방사성 농도는 인체에 영향이 없거나 거의 미미하므로 검출되었다 할지라도 특별한 조치가 필요 없다는 것이다. 예를 들어 최대오염농도 이상의 농도가 검출 될 시에는 기존에 조사해오던 주기보다 더 자주 측정하고 검출하한치 이하의 농도로 측정될 시에는 전에 해오던 주기대로 측정 및 관리를 하는 것이다. 이러한 각 핵종에 대하여 각각의 기준치를 정하고 미국 EPA(환경보호청)에서는 각 주(state)에 권한을 일임하여 자국의 주요 하천을 나누어 로드맵을 만들어 관리를 하고 있다. 그리고 그렇게 분류된 지역은 인력 및 예산에 맞게 HPGe, 형광검출기(NaI) 및 TLD 등의 검출기 등을 사용하여 효율적으로 측정값을 얻어 관리하고 있다.