• 제목/요약/키워드: radiation sphere

검색결과 85건 처리시간 0.021초

파수 영역의 방사 구면에서 음향 에너지 집중을 통한 평면파 생성 방법 (Generation of a plane-wave field by point focusing of acoustic potential energy on the radiation sphere in the wavenumber domain)

  • 장지호;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.820-823
    • /
    • 2007
  • In the wavenumber domain, each point on a radiation sphere indicates a plane wave of the frequency corresponding to radius of the sphere and the position on the sphere shows propagating direction of the plane wave. This concept is extended from the research by Choi[1] where he focus acoustic potential energy at a point on a radiation sphere. Here we propose the method to focus the energy at a point on the radiation sphere, as a result, we can easily generate a plane wave which propagates to any direction that we want.

  • PDF

간섭성 반스톡스 라만 산란 현미경 후방 신호지 방사패턴에 관한 이론계산 연구 (Theoretical Calculation on Radiation Patterns of Epi-signal in CARS Microscopy)

  • 유용심;조혁
    • 한국광학회지
    • /
    • 제18권4호
    • /
    • pp.286-291
    • /
    • 2007
  • 높은 수치구경의 대물렌즈를 사용하는 간섭성 반스톡스 라만 산란 현미경(coherent anti-Stokes Raman scattering microscopy)에서 폴리스틸렌구에서 발생한 신호의 먼거리장 방사패턴에 대한 이론적 계산 연구를 수행하였다. 극초점 조건에서 입사 레이저 광의 전기장 분포를 계산하였고, CARS 신호 생성원인인 비선형 분극(헤르치안 쌍극자) 방사의 간섭성 합을 통하여 먼거리장 방사 패턴을 계산하였다. 폴리스틸렌구의 크기에 따른 후방 방사패턴을 계산하였고, 1100 nm 직경을 가진 폴리스틸렌구와 폴리스틸렌 구껍질의 방사패턴을 비교하였다. 또한, 극초점으로부터 폴리스틸렌구의 중심이 이동함에 따른 방사패턴의 변화를 보였다.

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

MOT에서 좌표의존 비대칭 광압에 의한 루비듐 원자의 운동과 원자 구름 분포 (Atomic motion and spatial distribution of 87Rb by Coordinate-dependent asymmetry radiation force in MOT)

  • 박성종
    • 한국광학회지
    • /
    • 제11권4호
    • /
    • pp.221-226
    • /
    • 2000
  • MOT에 포획된 원자 구름의 분포가 포획광의 편광, 어긋난 정렬에 따라 구형, 막대형, 고리형, 가운데 구를 포함한 고리형, 구-구형, 구-고리형 등으로 다양하게 변하는 것을 관측하였다. 이는 포획광의 어긋난 정렬 등에 의한 좌표의존 비대칭 광압(Coordinate-dependent asymmetry radiation force ; CDARF)으로 설명할 수 있었다. 루비듐-87 원자의 S1/2(F=2), P3/2(F=3)준위에 축퇴된 제만 부준위에 대하여 제만 주파수 이동, 자기장과 포획광 방향에 따른 전이 확률, 편광에 따른 전이 확률, 레이저광의 편광, 레이저 광의 공간 분포 등을 고려하여 가능한 정확한 운동방정식을 세우고, 이를 풀어 다양한 형태의 원자구름 분포를 설명하였다.

  • PDF

LIMITATIONS OF SPHERE ANEMOMETRY FOR LOW GAS VELOCITY MEASUREMENTS

  • Han, J.Y.;O.F. Turan
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.297-304
    • /
    • 1997
  • Sphere anemometry technique is re-visited for low gas velocity measurements during full-scale fire tests. This technique has the advantage of requiring only one channel per sphere for data acquisition, in addition to being cheap and rugged, The results indicate that the technique is useful for small fuel load burns with low radiation levels. For large fuel loads, the usefulness is up to sprinkler activation temperatures.

  • PDF

규칙파(規則波)에 놓인 구(球)의 수평운동(水平運動)에 대(對)한 해석(解析) (On the Surge Motion of a Freely-Floating Sphere in a Plane Progressive Wave)

  • 박찬욱;최항순
    • 대한조선학회지
    • /
    • 제18권1호
    • /
    • pp.19-27
    • /
    • 1981
  • The surge motion of a freely-floating sphere in a regular wave is studied within the framework of a linear potential theory. The fluid is assumed to be perfect and only the steady-state harmonic motion in a water of infinite depth is considered. A velocity potential describing the fluid motion is decomposed into three parts; the incident wave potential, the diffraction potential and the radiation potential. In this paper the diffraction potential and the radiation potential are analysed by using multipole expansion method. Upon calculating pressures over the immersed surface of the sphere, the hydrodynamic forces are evaluated in terms of Froude-Krylov, diffraction, added mass and damping forces as functions of the frequency of the incident wave. Finally the frequency dependence of two pertinent parameters, the amplitude ratio and the phase lag between the motion of the sphere and that of the incident wave is derived from the equation of motion. As for numerical results the general tendency of the present calculation shows good agreement with Kim's work who also treated this problem utilizing the Green's function method.

  • PDF

서로 마주보며 비춰진 원형편극된 두 레이저 광속내에 놓인 균질구에 작용하는 광압 분포 및 특성 (Radiation Force Exerted on a Homogeneous Sphere by Two Circularly-Polarized Counterpropagating TEM00 Laser Beams)

  • 류지욱
    • 한국광학회지
    • /
    • 제2권2호
    • /
    • pp.74-82
    • /
    • 1991
  • 서로 마주보며 비춰진 원형편극된 두 $TEM_{00}$ 레이저 광속내에 부양된 균질구에 작용하는 광압분포를 조사하였다. 두 레이저 광속의 간섭효과를 고려하여 광압성분의 해석적 표현이 유도되었으며 정상 평면전자기파의 경우와 비교되었다. 광압분포에 대한 수치해석 결과가 제공되었으며 그 물리적 의미가 논의되었다.

  • PDF

구형 유전체 위에 있는 구형 패치의 공진 특성과 방사 특성 (Resonance Characteristics and Radiation Characteristics of a Spherical Patch on a Dielectric Sphere)

  • 정이루;홍익표;이명건;전흥재;육종관
    • 한국전자파학회논문지
    • /
    • 제23권4호
    • /
    • pp.515-523
    • /
    • 2012
  • 본 논문에서는 구형 유전체 위에 있는 구형 패치의 전파 특성으로서 공진 특성과 방사 특성을 분석하였다. 공진 주파수와 Q를 계산하여 특정 모드의 공진 특성을 해석하였으며, 원거리에서의 전기장을 계산하여 방사 특성을 해석하였다. 구형 유전체의 해석을 위해 스펙트럴 영역 해석법(spectral domain analysis method)를 적용하였으며, Vector Legendre transform pair와 Galerkin's method를 이용하여 스펙트럴 영역으로 변환한 후 대수식으로 정리하여 효율적인 계산을 할 수 있었으며, 이를 통해 구형 패치의 반지름이나 곡률, 유전체의 특성이 구형 패치의 특성에 미치는 영향을 해석하였다.

Calibration of the Pyranometer Sensitivity Using the Integrating Sphere

  • Kim, Bu-Yo;Lee, Kyu-Tae;Zo, Il-Sung;Lee, Sang-Ho;Jung, Hyun-Seok;Rim, Se-Hun;Jang, Jeong-Pil
    • Asia-Pacific Journal of Atmospheric Sciences
    • /
    • 제54권4호
    • /
    • pp.639-648
    • /
    • 2018
  • The pyranometer for observing the solar radiation reaching the surface of the earth is manufactured by various companies around the world. The sensitivity of the pyranometer at the observatory is required to be properly controlled based on the reference value of the World Radiometric Center (WRC) and the observatory environment; otherwise, the observational data may be subject to a large error. Since the sensitivity of the pyranometer can be calibrated in an indoor or outdoor calibration, this study used a CSTMUSS-4000C Integrating Sphere by Labsphere Inc. (USA) to calibrate the sensitivity of CMP22 pyranometer by Kipp&Zonen Inc. (Netherlands). Consequently, the factory sensitivity of CMP22 was corrected from $8.68{\mu}V{\cdot}(Wm^{-2})^{-1}$ to $8.98{\mu}V{\cdot}(Wm^{-2})^{-1}$, and the result from the outdoor calibration according to the observatory environment was $8.90{\mu}V{\cdot}(Wm^{-2})^{-1}$. After the indoor calibration of the pyranometer sensitivity, the root mean square error (RMSE) of the observational data at the observatory on a clear day without clouds (July 13, 2017) was $7.11Wm^{-2}$ in comparison to the reference pyranometer. After the outdoor calibration of the pyranometer sensitivity based on these results, the RMSE of the observational data was $1.74Wm^{-2}$ on the same day. Periodic inspections are required because the decrease of sensitivity over time is inevitable in the pyranometer data produced at the observatory. The initial sensitivity after indoor calibration ($8.98{\mu}V{\cdot}(Wm^{-2})^{-1}$) is important, and the sensitivity after outdoor calibration ($8.90{\mu}V{\cdot}(Wm^{-2})^{-1})$ can be compared to the data at the Baseline Surface Radiation Network (BSRN) or can be used for various studies and daily applications.

LiI 섬광검출기 기반의 보너구 스펙트로메터를 이용한 MC50 사이클로트론의 중성자스펙트럼 측정 (Measurement of neutron spectra in MC50 cyclotron using Bonner sphere spectrometer with LiI scintillation detector)

  • 하위호;박세영;유재룡;윤석원;이승숙;김정호;김종경
    • Journal of Radiation Protection and Research
    • /
    • 제38권3호
    • /
    • pp.143-148
    • /
    • 2013
  • 원자력발전소 및 입자 가속기 등 상용화된 원자력관계시설에서는 해당 시설 내부의 구조 및 위치 등에 따라 다양한 에너지를 가진 중성자스펙트럼을 나타내며 이에 대한 중성자선량 평가 및 작업자의 방사선방호 조치에 대한 수요는 점차 증가하고 있다. 중성자스펙트럼을 측정하기 위해서 일반적으로 보너구 스펙트로메터가 많이 이용된다. 보너구 스펙트로메터를 이용한 중성자 스펙트럼 측정의 경우 중성자검출기의 반응함수, 초기추정 스펙트럼, 계수율 측정값을 사용하여 중성자스펙트럼 언폴딩을 수행하게 된다. 본 연구에서는 MC50 사이클로트론에서 발생하는 중성자스펙트럼을 LiI 섬광검출기 기반의 보너구 스펙트로메터를 이용하여 측정하였으며 표적에 입사되는 양성자 에너지와 위치에 따른 중성자선속, 중성자 평균에너지 및 선량률 자료를 정량적으로 평가하였다.