• Title/Summary/Keyword: radiation safety

Search Result 1,454, Processing Time 0.03 seconds

Consumers' attitude to purchase irradiated foods and analysis of factors to distinguish acceptor groups (소비자의 방사선조사 식품 수용도 및 수용집단분류에 영향을 미치는 변수 분석)

  • Kim, Hyo-Chung;Kim, Mee-Ra
    • Journal of the Korean Society of Food Culture
    • /
    • v.14 no.4
    • /
    • pp.289-304
    • /
    • 1999
  • The purpose of this study was to examine the consumers' acceptance of irradiated foods according to sociodemographic characteristics and the factors to distinguish subjects with differential levels of their willingness to buy them. Data were collected from the 365 women living in Youngnam area by the self-administered questionnaire. The results from this study were as follows. First, consumers were concerned regarding food safety issues in general and particularly preservatives. Second, many subjects had not heard of the irradiated foods and showed wait-and-see attitude in the willingness to accept them. Consumers' willingness to purchase them were higher than any other cases if radiation would not remain in foods. Third, the results from the discriminant analyses showed that the concern toward food safety, perceived innovativeness, willingness to pay more for organic foods, and knowledge of irradiation were the factors to distinguish groups with differential levels of willingness to purchase the irradiated foods. The results from the study imply that accurate and scientific information about food irradiation should be given to the consumers.

  • PDF

Diagnostic Efficacy of Anorectal Manometry for the Diagnosis of Hirschsprung's Disease (Hirschsprung병에서 항문직장 내압검사의 진단적 유용성)

  • Chang, Soo-Hee;Min, Uoo-Gyung;Choi, Ok-Ja;Kim, Dae-Yeon;Kim, Seong-Chul;Yu, Chang-Sik;Kim, Jin-Cheon;Kim, In-Koo;Yoon, Jong-Hyun;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.1
    • /
    • pp.24-31
    • /
    • 2003
  • Purpose: As diagnostic tools for Hirschsprung's disease (HD), barium enema and rectal biopsy have radiation exposure and invasiveness respectively; however anorectal manometry does not have these disadvantages. We therefore performed this study to evaluate the diagnostic efficacy of anorectal manometry. Methods: We reviewed medical records of infants with one or two symptoms of vomiting, abdominal distension, chronic diarrhea or constipation who had a anorectal manometry followed by barium enema and/or biopsy from July 1995 to May 2002. We evaluated the sensitivity, specificity and predictive value of anorectal manometry and barium enema for diagnosis of HD. We also measured sphincter length, median value of balloon volume at which rectoanal inhibitory reflex (RAIR) occurred. Results: All 61 patients received anorectal manometry, 33 of 61 received barium enema. 18 of 61 were diagnosed as HD according to histology and 43 of 61 were evaluated as a control. The sensitivity, specificity, positive predictive value, negative predictive value of anorectal manometry and barium enema for diagnosis of HD were 1.00, 0.91, 0.82, 1.00 and 0.93, 0.67, 0.70, 0.92 respectively. The mean value of sphincter length in control was $1.68{\pm}0.67$ cm and correlated with age, weight and significantly longitudinal length. The median value of balloon volume at which RAIR occurred was 10 mL and did not correlated with age, weight and longitudinal length. Conclusion: This study suggests that anorectal manometry is an excellent initial screening test for Hirschsprung's disease because of its safety and accuracy.

  • PDF

The Clinical Usefulness of Transbronchial Lung Biopsy in Critically III Patients with Pulmonary Infiltrates of Uncertain Etiology (폐 침윤과 호흡부전을 동반한 중환자에서 경기관지폐생검의 임상적 유용성에 관한 연구)

  • Jang, Eun-Ha;Koh, Youn-Suck;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Go, Yun-Seok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.236-245
    • /
    • 2000
  • Background: Transbronchial lung biopsy(TBLB) has known to yield useful information for pulmonary infiltrates of uncertain etiology, However, its safety and usefulness have not been conclusive in the critically ill patients with respiratory failure. Moreover, TBLB has not been recommended for patients with mechanical ventilation. This study was conducted to investigate the diagnostic values and risks of Will performed on critically ill patients at bedside to obtain information on the pulmonary infiltrate of unknown etiology. Methods: Twenty patients(21 admissions with 23 cases) with diffuse pulmonary infiltrates who were treated in a medical intensive care unit of a tertiary referral hospital from January 1994 to May 1998, were enrolled for the study. Their medical records were retrospectively reviewed. TBLB was opted when a noninvasive diagnostic work-up failed to reveal the cause for the pulmonary infiltrate. The procedure was performed at patients' bedside without assistance of fluoroscopy. Bronchial washing or bronchoalveolar lavage was performed on the same pulmonary segment before performing TBLB. Results: Adequate specimens were obtained in 18 cases(78%). TBLB provided a specific diagnosis in two cases. The results of TBLB suggested the underlying etiology in 9 cases; bacterial pneumonitis(4), hypersensitivity pneumonitis(1), polymyositis(1), radiation fibrosis(1), idiopathic pulmonary fibrosis(1), and BOOP(1). Therapeutic decisions were altered in 11 cases(47.8%) based on the TBLB results. Pneumocystis carinii was found in the BAL fluid of another case. Ten patients with a therapeutic change and ten patients without a management change had mortality rates of 40% and 80%, respectively. The APACHE III scores were significantly higher in patients with complications($72.8{\pm}21.8$) compared with those without complications ($48.3{\pm}18.9$)(p<0.05). The complication rates were higher in those with mechanical ventilation(50%) than in those without Mechanical ventilation(33%), but the difference was not statistically significant(p=0.3). Conclusions: TBLB may be a useful diagnostic option for critically ill patients with unknown cause of pulmonary infiltrates. However, it should be cautious be used with care for patients with mechanical ventilation or for severely ill patients.

  • PDF

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

An Activation Analysis of Target("used H218O") for 18FDG Synthesis (18FDG 생산용 타겟("사용 후 H218O")의 방사화 분석)

  • Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.213-219
    • /
    • 2013
  • Currently, about 35 cyclotrons have been operating in South Korea. Most of them are mainly used for the synthesis of radiopharmaceuticals such as $^{18}FDG$, which is a cancer tracer for nuclear medicine. Highly enriched $H_2{^{18}}O$ containing up to 98% of $^{18}O/O$ isotope ratio is used as the target for $^{18}F$ production. The price of the highly enriched $H_2{^{18}}O$ ranges 60~70 USD/g, and all of them have been imported from foreign country in spite of the very expensive price. The target (enriched $H_2{^{18}}O$) is non-radioactive before the proton beam irradiation. But, the post-irradiation target (used $H_2{^{18}}O$) must be managed following the National Radiation Safety Regulations, because it turns into radioactive by the radioactivation of the impurities within the target. Recently, nevertheless of the fast increasing amount of used $H_2{^{18}}O$ in accordance with the increasing number of nuclear medicine cases, any activation analysis on the used $H_2{^{18}}O$ have been conducted yet in Korea. In this research, activation analysis have been conducted to confirm the specific radioactivity(Bq/g) of each radioisotopes within the used $H_2{^{18}}O$. The analysis have been done on the 3 of 20g samples collected from the used $H_2{^{18}}O$ storages at different cyclotron centers. Based on the results, it was confirmed that the "used $H_2{^{18}}O$" contains gamma emitters such as $^{56}Co$, $^{57}Co$, $^{58}Co$, and $^{54}Mn$ as well as the considerable amount of beta emitter $^3H$. It was also confirmed that the only one sample contained over exemption level of gamma emitters while the specific activity of tritium was lower than the exemption level in all samples. The specific activity of radioisotopes were measured different levels in the samples depending on the elapsed time after irradiation. Further study on the activation of the "used $H_2{^{18}}O$" is definitely necessary, nevertheless the as-is results of this research must be useful in establishing a rational "used $H_2{^{18}}O$" management protocol.

Cell Protective Effects of Enzymatic Hydrolysates of Citrus Peel Pectin (귤피 펙틴 유래 효소적 가수분해물의 세포 보호 효과)

  • Kwon, Soon Woo;Ko, Hyun Ju;Bae, Jun Tae;Kim, Jin Hwa;Lee, Geun Soo;Pyo, Hyeong Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.1
    • /
    • pp.75-85
    • /
    • 2016
  • Pectin, a naturally occurring polysaccharide, has in recent years attracted considerable attention. Its benefits are increasingly appreciated by scientists and consumers due to its safety and usefulness. The chemistry and gel-forming characteristics of pectin have enabled to be used in pharmaceutical industry, health promotion and treatment. Yet, it has been rarely used in cosmetics because of its incompatibility with many cosmetic ingredients, including alcohols, and unstable viscosity of pectin gels under various pH and salt conditions. However, low-molecular-weight pectin oligomers have excellent biological activities, and depolymerization of pectin to produce cosmetic ingredients would be very useful. In this study, we attempted the development of cosmetic ingredients using pectin with an excellent effect on human skin. We developed a bio-conversion process that uses enzymatic hydrolysis to produce pectin hydrolysates containing mainly low-molecular-weight pectin oligomers. Gel permeation chromatography was used to determined the ratio of hydrolysis. The molecular weight of the pectin hydrolysates obtained varied between 200 and 2,700 Da. The two newly developed low-molecular-weight pectin hydrolysates, LMPH A and B, had higher anti-oxidative activities than pectin or D-galacturonic. Exposure to UVB radiation induces apoptotic cell death in epidermal cells. Annexin V binding and propidium iodide uptake were measured by flow cytometry to evaluate UVB-induced cell death in HaCaT cells. Both LMPH A and B reduced UVB-induced cell death and increased cell proliferation by 22% and 30% at 0.5% concentration respectively, while pectin had no significant activity. In conclusion, this study suggests that the newly developed low-molecular-weight pectin hydrolysates can be used as safe and biologically active cosmetic ingredients.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

Identification of Pre-pasteurization or Pre-irradiation Treatment in Frozen Crushed Garlic Commercially Available in Korean Market (시판 유통 중인 냉동 다진 마늘의 사전 살균 및 조사처리 여부 판별 모니터링)

  • Kim, Hyo-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Jeong, Jin-Hwa;Park, Ki-Hwan;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1673-1681
    • /
    • 2013
  • Five different chopped frozen garlic products samples, three from Chinese and two from Korean origins being commercially available products in Korean market, were used to confirm their pre-pasteurization or pre-irradiation status by screening (direct epifluorescent filter technique/aerobic plate counts, DEFT/APC; electronic nose, E-nose; photostimulated luminescence, PSL) and identification (thermoluminescence, TL; electron spin resonance, ESR) techniques. Some parts of samples were gamma-irradiated at 1 kGy to be used as control samples in irradiation history identification. DEFT/APC and e-nose successfully showed distinct results between the domestic and imported samples. The PSL photon counts of all the unknown samples were less than 700 (negative), while most of 1 kGy-irradiated samples gave PSL photon counts more than 5,000 (positive). The domestic unknown samples produced the TL glow peaks after $300^{\circ}C$ or more, whereas the imported samples showed TL peaks at the range of $240{\sim}250^{\circ}C$. A clear TL glow peak was obtained from all irradiated samples at $150{\sim}250^{\circ}C$. The unknown samples of Chinese origin gave radiation-specific cellulose ESR signal that was not shown by domestic samples. A multiple step of applying the physical analytical methods is recommended for the effective identification of irradiation status on chopped frozen garlic products.

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Comparison of Perception Differences About Nuclear Energy in 4 East Asian Country Students: Aiming at $10^{th}$ Grade Students who Participated in Scientific Camps, from Four East Asian Countries: Korea, Japan, Taiwan, and Singapore (동아시아 4개국 학생들의 핵에너지에 대한 인식 비교: 과학캠프에 참가한 한국, 일본, 대만, 싱가포르 10학년 학생들을 대상으로)

  • Lee, Hyeong-Jae;Park, Sang-Tae
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.4
    • /
    • pp.775-788
    • /
    • 2012
  • This study was done at a scientific camp sponsored by Nara Women's University Secondary School, Japan. In this school, $10^{th}$ grade students from 4 East Asian countries: Korea, Japan, Taiwan, and Singapore, participated. We made a research on students' perceptions about nuclear energy. Sample populations include 77 students in total, with 12 Korean, 46 Japanese, 9 Taiwanese and 10 Singaporean students. Overall perceptions comparison about nuclear energy shows average values from the order of highest Korea, Taiwan, Singapore, and to lowest, Japan. We implemented a T-test to identify perception differences about nuclear energy, with one group that include 3 countries (Korea, Taiwan and Singapore) and another group that includes all the Japanese students. T-test results of perceptions about nuclear energy shows students from the 3 countries of Korea, Taiwan and Singapore having higher average than Japanese students. (p<.05). Korean average scores regarding overall perceptions about nuclear energy show as the highest in all 4 East Asian countries and also highest in all subcategories. On the contrary in Japan, they have lower and negative perceptions of nuclear energy. In spite of these facts, perceptions of Japanese students about nuclear energy seem lowest and negative mainly because of the recent Fukushima nuclear power plant disaster, caused by the tsunami and its subsequent damages and fears of radiation leaks, etc. This shows that negative information about future disasters and its resulting damages like the Chernobyl nuclear accident could influence more on people's risk perception than general information like nuclear energy-related technologies or the news that the plant is operating normally, etc. Even if the possibility of this kind of accident is very low, just one accident could bring abnormal risks to technology itself. This strong signal makes negative image and strengthens its perceptions to the people. This could bring a stigma about nuclear energy. This study shows that Government's policy about the highest priority for nuclear energy safety is most important. As long as such perception and decision are fixed, we found that it might not be easy to get changed again because they were already fortified and maintained.