• Title/Summary/Keyword: radiation noise

Search Result 765, Processing Time 0.026 seconds

Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-ray Tube for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2015
  • We studied the compact anode design to develop 100 kW rotating anode X-ray tube with large focal spot 1.2 mm, small focal spot 0.6 mm and tube voltage 150 kV for large hospital digital radiography using computer thermal simulation. The larger thermal radiation effect in a high vacuum can reduce the temperature of anode so the method to increase the surface area of anode is investigated. The anode has the multi-tier shape at the back side of TZM body of anode and also bigger diameter of anode. The number of multi-tiers was varied from 6 to 15 and the diameter of anode was also varied from ${\Phi}74$ to ${\Phi}82$. From ANSYS transient thermal simulation result, we could obtain $1056.4^{\circ}C$ anode maximum temperature when applying 100 kW input power at 0.1 second on target focal track which is less than $1091^{\circ}C$ of the conventional 75 kW X-ray tube with reduced anode weight by 15.5% than the conventional anode. The compact anode of reduced anode weight is able to improve the unwanted noise when the rotor is rotating at high-speed and also reduce the rotational torque which the cost effective stator-coil is possible. It is believed that the anode with 15 ea multi-tiers using ${\Phi}82$ can satisfy with the specification of the anode heat capacity. From the results of this paper, it has been confirmed that the proposed compact anode can be used as the anode of 100 kW rotating anode X-ray tube for digital radiography.

The Evaluation of the Characteristics of Electromagnetic Waves on CFRTP for Multimedia Instrument Applications (Multimedia 기기에의 적용을 위한 CFRTP에 대한 전자파 특성의 평가)

  • ;Ri-ichi Murakami
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.3
    • /
    • pp.254-263
    • /
    • 1997
  • As the communication and electronic industry develops, it is important to study the electromagnetic shielding effectiveness (SE) of carbon fiber (CF) reinforced thermal plastics (CFRTP) against the electromagnetic (EM) radiation. In this paper the shielding effectiveness of CFRTP was measured experimentally in an electromagnetic shielding room. The resin ma- terials used were PC, PP, PEI, PMMA and PA. Experiments were carried out by using a copper box and a monopole antenna with a spectrum analyzer. From the experimental results it was found that CF was a good candidate as an electromagnetic shielding material. The sheilding effectiveness was found to be increased in the composite as the number of laminated layers of CF was increased. As the minor damage increased, the SE increased due to increasing of the plane density, transmitting thickness and reflected angle of the CF. Other characteristics of the SE depended on the material used for the resin matrix, distance of the antennas and the noise frequency band.

  • PDF

System Performance Analysis for Multi-Band SweepSAR Operating Mode (다중대역 SweepSAR 운용 모드의 시스템 성능 분석)

  • Yoon, Seong-Sik;Lee, Jae-Wook;Lee, Taek-kyung;Ryu, Sang-Burm;Lee, Hyeon-Cheol;Kang, Eun-Su;Lee, Sang-Gyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.186-194
    • /
    • 2017
  • In this paper, we analyze the main performance of satellite's Synthetic Aperture Radar system for high resolution and wide swath. We have used the radiation pattern of reflector antenna with array feed and comparison between the conventional ScanSAR mode and SweepSAR mode has been carried out. The SweepSAR mode is a high-resolution wide-swath mode that transmits beams over a wide range and receives echo signals through sequential beamforming based on SCORE(SCan On REceive). In this paper, we analyzed the operating principle and characteristics of satellite's SweepSAR mode and simulate system performances. In addition, in order to increase the utilization of image, performances analysis for multiple frequency bands(C-band, X-band) has been considered.

Optical Characteristics of Bolometric Terahertz Sensor (볼로미터형 테라헤르츠 센서의 광학적 특성 연구)

  • Han, Myung Soo;Song, Woosub;Hong, Jung Taek;Lee, Donghee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.335-339
    • /
    • 2018
  • The optical characteristics of a terahertz (THz) antenna-coupled bolometer (ACB) detector were evaluated using a pulsed quantum cascade laser (QCL) and radiation blackbody sources. We investigated a method for measuring the responsivity and noise-equivalent power (NEP) of the THz detector using two different types of light sources. When using a QCL source with a frequency of 3 THz, the average responsivity of 24 devices was $1.44{\times}10^3V/W$ and the average NEP of those devices was $3.33{\times}10^{-9}W/{\surd}Hz$. The average responsivity and NEP as measured by blackbody source were $1.79{\times}10^5V/W$ and $6.51{\times}10^{-11}W/{\surd}Hz$, respectively, with the measured values varying depending on the light source. This was because the output power of each light source was different, with the laser source being driven by a pulse type wave and the blackbody source being driven by a continuous wave. The power input to the THz sensor was also different. Futhermore, the responsivity and NEP values measured using band pass filter (BPF) were similar to those measured when using only THz windows. It was found that ACB sensor responds normally in the THz region to both the laser and the blackbody source, and the method was confirmed to effectively evaluate the characteristics of the THz sensor.

A Case of Non-cardiogenic Pulmonary Edema caused by Nitrogen Dioxide Poisoning after Cutting Copper Pipe with an Oxyethylene Torch (산소 에틸렌 토치로 동파이프 절단작업 후 발생한 이산화질소 중독에 의한 비심인성 폐부종 1례)

  • JeGal, Yang-Jin;Ahn, Jong-Joon;Seo, Kwang-Won;Cha, Hee-Jeong;Kwon, Woon-Jung;Kim, Yang-Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.4 no.2
    • /
    • pp.175-179
    • /
    • 2006
  • Welders are exposed to a number of hazards including metal fumes, toxic gases, electricity, heat, noise, and radiation such as ultraviolet and infrared light. We encountered a patient who developed non-cardiogenic pulmonary edema within a day after cutting copper pipe with an oxyethylene torch. The patient was a 26-year-old welder. He complained of dyspnea, generalized myalgia, and febrile sensation the following morning. The patient's chest X-ray and chest CT scan showed extensively distributed and ill-defined centrilobular nodules. Both his symptoms and chest X-ray abnormalities improved spontaneously. We attributed the patient's symptoms to non-cardiogenic pulmonary edema due to nitrogen dioxide, reasoning that: 1) the pipe consisted only of copper, according to material safety data sheet (MSDS); 2) a previous report in the literature demonstrated increased nitrogen dioxide levels under similar conditions; 3) the patient's clinical course and radiologic findings were very reminiscent of non-cardiogenic pulmonary edema following accidental exposure to nitrogen dioxide.

  • PDF

Transmitter Design for Earth Station Terminal Operating with Military Geostationary Satellites on Ka-band (Ka 대역 군위성통신 지상단말 송신기 설계)

  • Kim, Chun-Won;Park, Byung-Jun;Yoon, Won-Sang;Lee, Seong-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.393-400
    • /
    • 2014
  • In this paper, we have designed the transmitter for earth station terminal operating with military geostationary satellite on Ka-band that is complied with MIL-STD-188-164A. The designed antenna of this terminal is dual-offset gregorian reflector which is consist of corrugated horn and iris polarizer, othermode transducer. This antenna meets radiation pattern and transmit EIRP spectral density requirements in this standard. The designed RF systems of this terminal are consist of Block Up Converter(BUC) converting frequency band from IF to Ka band and SSPA having low-power consumption and compact light-weight using the pHEMT MMIC compound devices. This RF systems applied with VSWR, spurious/harmonic suppression, output flatness and phase noise requirement in this standard.

Feasibility as radiation detectors of Flexible ITO film fabricated by roll-to-roll sputtering (롤-투-롤 스퍼터링으로 제작된 Flexible ITO Film의 방사선검출기 적용가능성 연구)

  • Kim, Sung-Hun;Lee, S.H.;Jeon, S.P.;Park, G.U.;Heo, E.S.;Sung, Han-Kyu;Park, J.G.;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.374-374
    • /
    • 2010
  • 본 연구는 Roll-to-Roll Sputtering 장비를 사용하여 제작된 Flexible ITO electrode 필름의 방사선 검출기로의 적용가능성을 알아보기 위해 기존의 Glass ITO electrode의 전기적 특성을 비교 평가하였다. 본 연구는 Flexible ITO electrode와 Glass ITO electrode을 하부전극으로 형성하고, 최근에 X-ray 변환체로 활발히 연구되고 있는 Powder 형태의 반도체물질인 HgI2 와 PbI2를 Binder와 일정한 비율로 혼합하여 3-Rolls-Miller를 사용하여 Powder를 일정한 미세크기로 만들고, 대면적 제작이 용이한 Screen-Printing method을 이용하여 시편을 제작하였다. 제작된 필름은 하부전극의 종류에 따른 X-ray 입사 후의 전기적신호의 차이를 측정하고, HgI2와 PbI2 중 Flexible ITO electrode와 더욱 효율적으로 반응하여 기존의 Glass ITO electrode를 대체할 수 있는 전극을 발견하여 진단용 의료영상의 왜곡 현상을 제거할 수 있는 Flexible 방사선 검출기의 제작의 초석을 제공하는 연구를 목적으로 한다. SEM(Scanning Electron Microscope) 통하여 반도체 물질의 결정구조와 크기를 알아보았고, 하부 전극의 종류에 따른 전기적 신호검출을 위해 제작된 필름의 암전류(Dark current) 와 민감도(Sensitivity)를 측정한 후, SNR (Signal -to- Noise)을 계산하여 평가하였다.

  • PDF

The Fabrication and Property Evaluation of Poly-crystalline CdTe based Photon Counting X-ray Sensor (다결정 CdTe 기반의 광계수형 X선 센서 제작 및 특성평가)

  • Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.439-443
    • /
    • 2015
  • An electrical signals of a conventional radiation medical imaging sensor are obtained by charge integration method. In this study, the polycrystalline cadmium telluride(p-CdTe) film was fabricated by a thermal evaporation method for the photon counting sensor development with excellent resolution in low exposure dose. From the fabricated p-CdTe sensor, the physical properties(SEM, XRD) and the electrical properties(leakage current, x-ray sensitivity, SNR) were evaluated. As a result, the leakage current of below $5nA/cm^2$ and $7{\mu}C/cm^2-R$ of the X-ray sensitivity were showed in below $1V/{\mu}m$. In addition, the signal to noise ratio showed the values of above 5000 at operating voltage.

THE DEVELOPMENT OF CIRCULARLY POLARIZED SYNTHETIC APERTURE RADAR SENSOR MOUNTED ON UNMANNED AERIAL VEHICLE

  • Baharuddin, Merna;Akbar, Prilando Rizki;Sumantyo, Josaphat Tetuko Sri;Kuze, Hiroaki
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.441-444
    • /
    • 2008
  • This paper describes the development of a circularly polarized microstrip antenna, as a part of the Circularly Polarized Synthetic Aperture Radar (CP-SAR) sensor which is currently under developed at the Microwave Remote Sensing Laboratory (MRSL) in Chiba University. CP-SAR is a new type of sensor developed for the purpose of remote sensing. With this sensor, lower-noise data/image will be obtained due to the absence of depolarization problems from propagation encounter in linearly polarized synthetic aperture radar. As well the data/images obtained will be investigated as the Axial Ratio Image (ARI), which is a new data that hopefully will reveal unique various backscattering characteristics. The sensor will be mounted on an Unmanned Aerial Vehicle (UAV) which will be aimed for fundamental research and applications. The microstrip antenna works in the frequency of 1.27 GHz (L-Band). The microstrip antenna utilized the proximity-coupled method of feeding. Initially, the optimization process of the single patch antenna design involving modifying the microstrip line feed to yield a high gain (above 5 dBi) and low return loss (below -10 dB). A minimum of 10 MHz bandwidth is targeted at below 3 dB of Axial Ratio for the circularly polarized antenna. A planar array from the single patch is formed next. Consideration for the array design is the beam radiation pattern in the azimuth and elevation plane which is specified based on the electrical and mechanical constraints of the UAV CP-SAR system. This research will contribute in the field of radar for remote sensing technology. The potential application is for landcover, disaster monitoring, snow cover, and oceanography mapping.

  • PDF

Characteristics of Embedded R, L, C Fabricated by Using LTCC-M Technology and Development of a PAM for LMR thereby (LTCC-M 기술을 이용한 내부실장 R, L, C 수동소자의 특징 및 LMR용 PAM개발)

  • 김인태;박성대;강현규;공선식;박윤휘;문제도
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.1
    • /
    • pp.13-18
    • /
    • 2000
  • Low temperature co-fired ceramics on metal (LTCC-M) is efficient for embedding passive components with good tolerance in a module due to the dimensional stability in x and y directions by the constraint of metal core during the firing. In addition, the radiation noise can be reduced by metal core. In this paper, embedded passive components were introduced and a power amplifier module (PAM) fabricated by using the passive components was explained. The embedded passive components in test patters showed the tolerance of 10~20% and the good repeatability in tolerance of embedded passives was maintained in module fabrication. The shortened traces in multi chip modules (MCMs) make the signal delay time decreased and the embedded passives simplify the packaging processes owing to the less solder points, which enhance the electrical performance and increase the reliability of the modules. The LTCC-M technology is one of the promising candidates for RF application and is expected to expand its applications to power and high performance devices.

  • PDF