• 제목/요약/키워드: radiation detector

검색결과 859건 처리시간 0.024초

A TiO2-Coated Reflective Layer Enhances the Sensitivity of a CsI:Tl Scintillator for X-ray Imaging Sensors

  • Kim, Youngju;Kim, Byoungwook;Kwon, Youngman;Kim, Jongyul;Kim, MyungSoo;Cho, Gyuseong;Jun, Hong Young;Thap, Tharoeun;Lee, Jinseok;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.256-260
    • /
    • 2014
  • Columnar-structured cesium iodide (CsI) scintillators doped with thallium (Tl) are frequently used as x-ray converters in medical and industrial imaging. In this study we investigated the imaging characteristics of CsI:Tl films with various reflective layers-aluminum (Al), chromium (Cr), and titanium dioxide ($TiO_2$) powder-coated on glass substrates. We used two effusion-cell sources in a thermal evaporator system to fabricate CsI:Tl films on substrates. The scintillators were observed via scanning electron microscopy (SEM), and scintillation characteristics were evaluated on the basis of the emission spectrum, light output, light response to x-ray dose, modulation transfer function (MTF), and x-ray images. Compared to control films without a reflective layer, CsI:Tl films with reflective layers showed better sensitivity and light collection efficiency, and the film with a $TiO_2$ reflective layer showed the best properties.

인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구 (A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구 (The study of collimator and radiation shield for the detection of the gamma-ray distribution)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.944-945
    • /
    • 2016
  • 감마선 영상화 장치에서 감마선을 탐지하는 검출부는 선원을 바라보는 Collimator와 Collimator 이외의 방향에서 입사되는 감마선을 차폐하기 위한 차폐체로 구성되며 검출센서는 해당 차폐체 내부에 위치하게 된다. 감마선에 대한 분포는 Collimator의 입사구를 통해 들어오는 신호와 검출부가 바라보는 방향에 대한 정보를 통해 분포를 나타낼 수 있다. 때문에 입사구에서 들어오는 신호 외에는 잡음으로 처리해야 하므로 차폐체의 역할이 중요하다. 본 논문에서는 상용 감마선 탐지장치의 보다 축소된 납 기반의 콜리메이터 및 차폐체에 대하여 구조와 물성을 변경하여 소형, 경량화 된 Collimator 및 차폐체를 제작하였다. 또한 감마선 조사시험시설을 이용하여 감마선 입사구의 측정된 신호값을 기준으로 차폐 효율을 분석하였다. 분석결과 제작된 Collimator 및 차폐체가 영상화 장치구현를 구현하는데 보다 효율적임을 확인하였다.

  • PDF

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.

현장검출기에 저장된 백업데이터를 무선통신방식으로 자동 복원하는 실시간 환경선량 감시 시스템 (Real-time Environmental Radiation Monitoring System with Automatic Restoration of Backup Data in Site Detector via Communication using Radio Frequency)

  • 이완로;김은한;정근호;조영현;최근식;이창우;박기현;김윤구
    • Journal of Radiation Protection and Research
    • /
    • 제28권3호
    • /
    • pp.255-261
    • /
    • 2003
  • 환경선량변동을 실시간으로 모니터링하기 위해서 원자력연구소 부지 주변에 온라인 감시시스템이 운영중인데, 현장에 설치된 전리함 검출기에 의해서 측정된 자료는 모뎀을 통해 무선전송방식으로 중앙제어실에 실시간으로 저장된다. 무선 송수신 방식은 전송, 처리 및 저장에 경제적이고 효과적이지만 통신 장애시 현장감시장치에 저장된 백업데이터를 가져오지 못해서 결국 데이터가 손실될 우려가 있다 물론 버퍼에 저장된 선량값을 디스켓 및 다른 off-line으로 복원이 가능하지만 이럴 경우 온라인으로 운영되는 시스템에 과거데이터를 처리해야 하므로 복잡하고 실시간으로 처리 할 수가 없다. 본 연구에서는 기존 감시시스템 중 신호처리 부분과 운영 소프트웨어를 새롭게 개발해서, 현장에 설치된 감시기와 중앙처리 장치의 시각을 매일 자동으로 동기화시키고 이를 이용해서 현장감시장치에 저장된 백업데이터를 자동으로 복원시켰다. 새로 개발된 방식을 이용할 경우 34시간이내에서 통신장애로 수신하지 못한 백업데이터를 자동으로 복원할 수 있고, 복원된 데이터를 현재시각의 데이터와 함께 실시간으로 디스플레이 할 수 있게 하였다.

PTW-LinaCheck 측정기의 선량 특성과 일일 출력측정 응용에 관한 연구 (Study on the Dose Characteristics of the PTW-LinaCheck Dosimeter and Its Application to Daily Output Measurement)

  • 정동혁;이강규;문언철;김현진;김영석;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.56-62
    • /
    • 2008
  • 본 연구에서는 선형가속기 출력 검출용으로 상용화된 PTW-LinaCheck의 선량 특성을 조사하고 임상적 응용에 관하여 논의하고자 한다. 본 연구에서는 6, 15MV광자선 및 4, 6, 9, 12, 16 MeV전자선에 대하여 측정값의 재현성, 선형성, 선량률 의존성을 조사하였다. 또한 측정값의 오차범위를 조사하기 위하여 일일 점검 시 검출기의 셋업의 기하학적 오차에 의한 측정값의 변화를 조사하였다. 본 측정의 결과로서 일일 측정 시 셋업 오차에 의한 측정값의 변화는 재현성을 포함하여 ${\pm}0.6%$ 이내로 평가되었다. 이 때 선형성과 선량률 의존성에 의한 오차는 무시할 정도였다. 이를 통하여 LinaCheck는 선량 특성과 편리한 셋업의 관점에서 양호한 것으로 결론을 내렸다. 아울러 본 논문에서는 본 검출기를 사용한 60여 일간의 임상적 적용 사례도 제시하였다.

  • PDF

의료 방사선 검출기로써 스마트폰 카메라의 특성에 관한 연구 (A Study on the Characteristics of Smartphone Camera as a Medical Radiation Detector)

  • 강한규;김호철
    • 전자공학회논문지
    • /
    • 제53권5호
    • /
    • pp.143-151
    • /
    • 2016
  • 본 연구의 목적은 별도의 방사선 외부 검출장치 없이 스마트폰 자체의 CMOS 반도체 소자만을 활용하여 의료용 방사선 발생장치에서 발생하는 방사선을 효율적으로 검출하기 위한 최적의 조건과 알고리즘을 개발하는 것이다. 본 연구를 통하여 스마트폰에 내장된 CMOS 반도체 소자에 X-선의 선량을 증가시켜가면서 CMOS 영상 센서에서 반응하는 픽셀의 개수 및 밝기 등을 측정하였다. 스마트폰의 전면 카메라가 후면 카메라보다 노이즈가 적고 X-선과 같은 방사선에 대한 반응 특성이 우수하였다. 섬광결정을 사용한 간접 검출방식에 보다 CMOS 자체에 X-선을 반응시키는 직접 검출방식이 더 적은 선량까지 정확하게 검출이 가능하였다. 또한 X-선에 대한 선량의존성은 역치값을 넘어가는 픽셀의 개수를 계산한 Pixel number에 비해 개별 반응한 픽셀의 밝기까지 이용한 Pixel intensity가 더욱 선형적으로 나타났다. 컬러모델에 의한 실험에서는 스마트폰의 컬러모델인 YUV 컬러모델의 값 중 픽셀의 밝기값의 정보를 가지고 있는 Y값을 활용하면 방사선 검출에 있어 효율적일 것으로 사료된다. 향후 이와 같은 방사선 검출을 위한 최적의 조건들과 효율적 검출 알고리즘들에 대한 추가적인 연구가 진행된다면 방사선 선량의 관리가 효율적이며 체계적으로 이루어 질 수 있기 때문에 국민보건건강에 일조 할 수 있을 것으로 사료된다.

진폐요양환자의 흉부 CT촬영에 사용된 선량 - 국내외 진단 참고 준위와 비교 - (Radiation Dose using Chest CT for Patients with Pneumoconiosis Complication - Comparison with International Guidelines -)

  • 이원정
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.206-212
    • /
    • 2014
  • 진폐요양기관에 대한 실태조사를 실시하여 진폐요양환자에게 사용되는 흉부 CT촬영 선량이 국내외 진단 참고 준위 내에서 사용되는지 알아보았다. 진폐요양기관은 27개 중에서 운용자 콘솔 컴퓨터에서 환자 피폭선량(dose length product, $mGy^*cm$, 이하 DLP) 확인이 가능한 2-Detector 이상 설치된 17개 기관을 대상으로 하였다. 연구대상기관을 직접 연구자가 방문하여 위치잡이촬영, 조영제 사용전,후촬영 및 총 DLP 값을 각각 확인하였다. 또한, 장치의 기본 항목, 위치잡이촬영 조건, 본촬영(scanning) 조건 및 영상 획득 조건을 확인하였다. 흉부 CT촬영에서 확인된 총 DLP 값, 조영제주입전촬영 DLP 값의 상향서열 3/4 순위에 해당하는 DLP 값을 구하였다. SPSS ver. 19.0을 사용하여 전체 영상과 폐야영상 간에 조영제주입전촬영 DLP 값의 비교는 비모수 검정(Wilcoxon signed rank test)을 실시하였다. 전체영상보다 폐야영상을 얻을 때 20.2%의 유의한 DLP 값 감소를 보였다(707.2 vs. 555.9, p<0.001). 흉부 CT촬영에서 확인된 총 DLP 값의 상향서열 3/4 순위(third quartile)의 DLP 값은 $1036.1mGy{\cdot}cm$였다. 흉부 CT촬영의 조영제 주입전촬영에서 확인된 DLP 값의 상향서열 3/4 순위의 DLP 값은 $504.1mGy{\cdot}cm$였다. 진폐요양환자의 흉부 CT촬영에 사용하는 선량은 국내외 진단 참고 준위와 큰 차이를 보이지 않았다.

InAs/GaSb 응력초격자를 이용한 적외선검출소자의 제작 및 특성 연구 (Fabrication and Device Characteristics of Infrared Photodetector Based on InAs/GaSb Strained-Layer Superlattice)

  • 김준오;신현욱;최정우;이상준;김창수;노삼규
    • 한국진공학회지
    • /
    • 제18권2호
    • /
    • pp.108-115
    • /
    • 2009
  • 150 주기의 InAs/GaSb (8/8-ML) 제2형 응력초격자 (SLS)를 활성층에 탑재한 초격자 적외선검출소자 (SLIP) 구조를 MBE 방법으로 성장하고, 직경 $200{\mu}m$의 개구면을 가지는 SLIP 개별소자를 시험 제작하였다 고분해능 투과전자현미경 (TEM) 이미지의 휘도분포와 X선회절 (XRD) 곡선의 위성피크의 분석 결과는 SLS 활성층은 균일한 층두께와 주기적 응력변형을 유지하는 급격한 계면의 초격자임을 입증하였다. 흑체복사 적외선 광원을 이용하여 측정한 입사파장 및 인가전압에 따른 반응도 (R)와 검출률 ($D^*$)로부터, 차단파장은 ${\sim}5{\mu}m$이고 최대 R과 $D^*$ ($\lambda=3.25{\mu}m$)는 각각 ${\sim}10^3mA/W$ (-0.6 V/13 K)와 ${\sim}10^9cm.Hz^{1/2}/W$ (0 V/13 K)임을 보였다. 반응도의 온도의존성으로부터 분석한 활성화에너지 275 meV는 광반응 과정에 개입되어 있는 가전대 및 전도대 부준위 사이의 에너지 간격 (HH1-C)과 잘 일치하였다.