References
- H. Wieczorek, "Physical aspects of detector design," Rad. Meas. 33, 541-545 (2001). https://doi.org/10.1016/S1350-4487(01)00055-5
- C. W. Bates, "Scintillation processes in thin films of CsI (Na) and CsI(Tl) due to low energy X-rays, electrons and protons," Adv. Eletron. E1. Phys. A 28, 451-459 (1969).
- V. Ryzhikov, D. Kozin, B. Grinyov, E. Lysetskaya, J. Katrunov, V. Kvyatnitskaya, and V. Chernikov, "Scintillationphotodiode detector for scanning introscopy with high spatial resolution," Nucl. Instrum. Meth A 505, 58-62 (2003). https://doi.org/10.1016/S0168-9002(03)01020-9
- V. V. Nagarkar, J. S. Gordon, S. Vasile, P. Gothoskar, and F. Hopkins, "High resolution X-ray sensor for non destructive evaluation," IEEE. Trans. Nucl. Sci. 43, 1559-1563 (1996). https://doi.org/10.1109/23.507103
- W. Knupfer, E. Hell, and D. Mattern, "Novel X-ray detectors for medical imaging," Nucl. Phys. B 78, 610-615 (1999). https://doi.org/10.1016/S0920-5632(99)00613-1
- R. H. Bartram and A. J. Lempicki, "Efficiency of electronhole pair production in scintillator," J. Lumin. 68, 225-240 (1996). https://doi.org/10.1016/0022-2313(96)00026-9
- R. Gwin and R. B. Murray, "Scintillaton process in CsI(Tl). II. Emission spectra and the possible role of self-trapped hole," Phys. Rev. Lett. 131, 508-512 (1963).
- A. Fedorov, A. Lebedinsky, and O. Zelenskaya, "Scintillation efficiency, structure and spatial resolution of CsI(Tl) layers," Nucl. Instrum. Meth A 564, 328-331 (2006). https://doi.org/10.1016/j.nima.2006.04.037
- J. Yorkston, "Recent developments in digital radiography detectors," Nucl. Instrum. Meth A 580, 974-985 (2007). https://doi.org/10.1016/j.nima.2007.06.041
-
B. K. Cha, J. Y Kim, T. J. Kim, C. Sim, and G. Cho, "Fabrication and imaging characterization of high sensitive CsI(Tl) and
$Gd_2O_2S(Tb)$ scintillator screens for X-ray imaging detector," Rad. Meas. 45, 742-745 (2010). https://doi.org/10.1016/j.radmeas.2009.12.025 - B. K. Cha, J. H. Bae, C. Lee, H. Jeon, H. Kim, S. Chang, B. S. Kang, and G. Cho, "Improvement of the sensitivity and spatial resolution of pixelated CsI:Tl scintillator with reflective coating," Nucl. Instrum., Meth A 607, 145-149 (2009). https://doi.org/10.1016/j.nima.2009.03.145
- B. Schmitt, M. Fuchs, E. Hell, W. Knupfer, P. Hackenschmied, and A. Winnake, "Structured alkali halides for medical applications," Nucl. Instrum. Meth B 191, 800-804 (2002). https://doi.org/10.1016/S0168-583X(02)00656-0
- B. K. Cha, J. H. Shin, J. H. Bae, C. Lee, S. Chang, H. K. Kim, C. K. Kim, and G. Cho, "Scintillation characteristics and imaging performance of CsI:Tl thin films for X-ray imaging applications," Nucl. Instrum. Meth A 604, 224-228 (2009). https://doi.org/10.1016/j.nima.2009.01.177
- B. Wang, K. Barner, D. Lee, B. Rodricks, and C. Liu, "A simple edge device method for determining the presampling modulation transfer function (MTF) of flat field digital detectors," Proc. SPIE 5745, 1191-1198 (2005).
- E. Samei, M. J. Flynn, and D. A. Reimann, "A method for Measuring the pre-sampled MTF of digital radiographic system using an edge test device," Med. Phys. 25, 102-113 (1998). https://doi.org/10.1118/1.598165
- E. Samei and M. J. Flynn, "An experimental comparison of detector performance for direct and indirect digital radiography systems," Med. Phys. 30, 608-622 (2003). https://doi.org/10.1118/1.1561285
Cited by
- Effects of film thickness on scintillation characteristics of columnar CsI:Tl films exposed to high gamma radiation doses vol.810, 2016, https://doi.org/10.1016/j.nima.2015.11.122
- A comparative study of scintillator combining methods for flat-panel X-ray image sensors vol.882, 2018, https://doi.org/10.1016/j.nima.2017.11.023