A Design of Solar Proton Telescope for Next Generation Small Satellite

  • Sohn, Jongdae;Oh, Suyeon;Yi, Yu;Min, Kyoung-Wook;Lee, Dae-Young;Seon, Jongho
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권4호
    • /
    • pp.343-349
    • /
    • 2012
  • The solar proton telescope (SPT) is considered as one of the scientific instruments to be installed in instruments for the study of space storm (ISSS) which is determined for next generation small satellite-1 (NEXTSat-1). The SPT is the instrument that acquires the information on energetic particles, especially the energy and flux of proton, according to the solar activity in the space radiation environment. We performed the simulation to determine the specification of the SPT using geometry and tracking 4 (GEANT4). The simulation was performed in the range of 0.6-1,000 MeV considering that the proton, which is to be detected, corresponds to the high energy region according to the solar activity in the space radiation environment. By using aluminum as a blocking material and adjusting the energy detection range, we determined total 7 channels (0.6~5, 5~10, 10~20, 20~35, 35~52, 52~72, and >72 MeV) for the energy range of SPT. In the SPT, the proton energy was distinguished using linear energy transfer to compare with or discriminate from relativistic electron for the channels P1-P3 which are the range of less than 20 MeV, and above those channels, the energy was determined on the basis of whether silicon semiconductor detector (SSD) signal can pass or not. To determine the optimal channel, we performed the conceptual design of payload which uses the SSD. The designed SPT will improve the understanding on the capture and decline of solar energetic particles at the radiation belt by measuring the energetic proton.

고온 계측 열화상 시스템 구현을 위한 복사에너지 필터링 연구 (Radiant Energy Filtering to Enhance High Temperature Measurement by a Thermography System)

  • 윤석태;조용진;정호석
    • 비파괴검사학회지
    • /
    • 제36권6호
    • /
    • pp.466-473
    • /
    • 2016
  • 선박 건조과정에서 이면부의 도장손상은 용접과정에서 과도한 입열량(heat input)에 따른 전도의 영향으로 손상 방지를 위해서는 용접온도 계측에 의한 적절한 입열량 제어가 필요하다. 온도 계측에는 접촉식, 비접촉식 방법이 있으며 열화상 시스템은 대표적인 비접촉식 방법이다. 하지만 일반적인 열화상 시스템의 탐지센서(detector)는 고온물체에서 방출되는 복사량(radiant quantity)이 과도하면 백화현상(saturation)으로 인해 온도계측이 불가능해진다. 따라서 본 논문에서는 열화상 시스템에 집속되는 과도한 복사량을 차단하기 위해 중성밀도필터(neutral density filter)를 결합하여 고온 물체의 온도를 $3000^{\circ}C$까지 정량적으로 계측하기 위한 복사 에너지 필터링을 연구하였다.

선형가속기의 동적쐐기(EDW) 작동에 대한 품질보증 (Quality Assurance of Operation of Enhanced Dynamic Wedges in Linac)

  • 정동혁;김진기;강정구;손광재;이정옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.133-141
    • /
    • 2010
  • 선형가속기의 동적쐐기(enhanced dynamic wedge: EDW)의 품질보증을 위하여 다양한 방법으로 동적쐐기의 특성을 평가하였다. 본 연구에서는 6 MV와 15 MV 엑스선에 대하여 각각 7종(10, 15, 20, 25, 30, 45, 60도)의 EDW를 평가하였다. EDW 작동에 필요한 STT(segmented treatment table)를 계산으로 구하고 로그파일을 통하여 기계적 작동을 평가하였으며, 이차원배열형검출기와 전리함을 사용하여 팬텀속 선량분포를 측정하고 치료계획시스템(RTP)과 비교하였다. EDW의 기계적 작동은 예상과 잘 일치하였으며, 빔측면도를 포함한 이차원선량분포는 근사적으로 RTP 계산과 일치하였다. 선형가속기 조사량 100 MU에 대한 출력선량은 RTP 계산과 2.9% 이내로 일치하였으며, 측정된 쐐기인자는 RTP 계산과 최대 2.6%를 보였다. 이 결과들은 본 선형가속기에 장착된 EDW의 임상적 적용에 문제가 없음을 의미한다.

6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

다종 감마선 공간분포 측정을 위한 고감도 검출센서 및 탐지모듈 개발 (Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.705-707
    • /
    • 2017
  • 스테레오기반의 공간방사선 탐지장치는 방사선원에 대한 공간분포정보 뿐만 아니라 탐지장치로부터 선원까지의 거리정보를 얻을 수 있어 기존 방사선 영상화 장치보다 선원에 대한 효율적인 정보를 제공한다. 또한 감마선원의 스펙트럼 및 종류에 대한 정보를 고속으로 제공하기 위해서는 감도가 높은 고감도 검출센서가 필요하며 고선량에서의 포화되는 현상을 해소할 수 있는 기법이 필요하다. 본 논문에서는 다종 감마선 공간분포 측정을 위해 고감도 센서를 구성하고, 검출모듈의 기능을 개선하여 고선량에서의 포화상태를 해소함으로써 단일센서로 탐지범위 증대를 위한 연구를 수행하였다. 본 논문의 결과는 향후 스테레오기반의 감마선 탐지장치의 성능개선을 위해 활용될 것이다.

  • PDF

Investigation of gamma radiation shielding capability of two clay materials

  • Olukotun, S.F.;Gbenu, S.T.;Ibitoye, F.I.;Oladejo, O.F.;Shittu, H.O.;Fasasi, M.K.;Balogun, F.A.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.957-962
    • /
    • 2018
  • The gamma radiation shielding capability (GRSC) of two clay-materials (Ball clay and Kaolin)of Southwestern Nigeria ($7.49^{\circ}N$, $4.55^{\circ}E$) have been investigated by determine theoretically and experimentally the mass attenuation coefficient, ${\mu}/{\rho}(cm^2g^{-1})$ of the clay materials at photon energies of 609.31, 1120.29, 1173.20, 1238.11, 1332.50 and 1764.49 keV emitted from $^{214}Bi$ ore and $^{60}Co$ point source. The mass attenuation coefficients were theoretically evaluated using the elemental compositions of the clay-materials obtained by Particle-Induced X-ray Emission (PIXE) elemental analysis technique as input data for WinXCom software. While gamma ray transmission experiment using Hyper Pure Germanium (HPGe) spectrometer detector to experimentally determine the mass attenuation coefficients, ${\mu}/{\rho}(cm^2g^{-1})$ of the samples. The experimental results are in good agreement with the theoretical calculations of WinXCom software. Linear attenuation coefficient (${\mu}$), half value layer (HVL) and mean free path (MFP) were also evaluated using the obtained ${\mu}/{\rho}$ values for the investigated samples. The GRSC of the selected clay-materials have been compared with other studied shielding materials. The cognizance of various factors such as availability, thermo-chemical stability and water retaining ability by the clay-samples can be analyzed for efficacy of the material for their GRSC.

스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구 (The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector)

  • 황영관;이남호;이승민
    • 전자공학회논문지
    • /
    • 제52권4호
    • /
    • pp.197-203
    • /
    • 2015
  • 전 세계적으로 전력생산을 위해 원전 증설이 지속적으로 증가하고 있으며 이에 따라 노후 원전에 대한 해체 및 원전사고에 대한 관심이 증가하고 있다. 원전 사고 시 발생되는 감마선원의 누출은 신속하고 정확한 탐지해야 그 피해를 최소화 시킬 수 있다. 기 개발된 장비는 선원에 대한 방향정보만을 나타내고 있어 정확한 공간상의 분포를 알 수 없다. 본 논문에서 개발한 스테레오 감마선탐지장치는 누출된 감마선원에 대한 분포를 측정할 수 있도록 구현하고 거리탐지를 위한 알고리즘을 적용하였다. 거리탐지를 위하여 스테레오 보정을 LED광과 보정패턴을 사용하여 진행하였고, LED 광원과 감마선원을 대상으로 성능시험을 진행하였다. 성능시험 결과 두 실험에서 5%이하의 오차를 갖게 됨을 확인하였다. 본 논문의 결과는 향후 고속 경량화 된 감마선 영상화 장치 개발을 위한 자료로 활용될 것이다.

A TiO2-Coated Reflective Layer Enhances the Sensitivity of a CsI:Tl Scintillator for X-ray Imaging Sensors

  • Kim, Youngju;Kim, Byoungwook;Kwon, Youngman;Kim, Jongyul;Kim, MyungSoo;Cho, Gyuseong;Jun, Hong Young;Thap, Tharoeun;Lee, Jinseok;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.256-260
    • /
    • 2014
  • Columnar-structured cesium iodide (CsI) scintillators doped with thallium (Tl) are frequently used as x-ray converters in medical and industrial imaging. In this study we investigated the imaging characteristics of CsI:Tl films with various reflective layers-aluminum (Al), chromium (Cr), and titanium dioxide ($TiO_2$) powder-coated on glass substrates. We used two effusion-cell sources in a thermal evaporator system to fabricate CsI:Tl films on substrates. The scintillators were observed via scanning electron microscopy (SEM), and scintillation characteristics were evaluated on the basis of the emission spectrum, light output, light response to x-ray dose, modulation transfer function (MTF), and x-ray images. Compared to control films without a reflective layer, CsI:Tl films with reflective layers showed better sensitivity and light collection efficiency, and the film with a $TiO_2$ reflective layer showed the best properties.

인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구 (A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구 (The study of collimator and radiation shield for the detection of the gamma-ray distribution)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.944-945
    • /
    • 2016
  • 감마선 영상화 장치에서 감마선을 탐지하는 검출부는 선원을 바라보는 Collimator와 Collimator 이외의 방향에서 입사되는 감마선을 차폐하기 위한 차폐체로 구성되며 검출센서는 해당 차폐체 내부에 위치하게 된다. 감마선에 대한 분포는 Collimator의 입사구를 통해 들어오는 신호와 검출부가 바라보는 방향에 대한 정보를 통해 분포를 나타낼 수 있다. 때문에 입사구에서 들어오는 신호 외에는 잡음으로 처리해야 하므로 차폐체의 역할이 중요하다. 본 논문에서는 상용 감마선 탐지장치의 보다 축소된 납 기반의 콜리메이터 및 차폐체에 대하여 구조와 물성을 변경하여 소형, 경량화 된 Collimator 및 차폐체를 제작하였다. 또한 감마선 조사시험시설을 이용하여 감마선 입사구의 측정된 신호값을 기준으로 차폐 효율을 분석하였다. 분석결과 제작된 Collimator 및 차폐체가 영상화 장치구현를 구현하는데 보다 효율적임을 확인하였다.

  • PDF