• Title/Summary/Keyword: radiation detection circuit

Search Result 36, Processing Time 0.03 seconds

Design of radiation detection circuit for gamma column scanning (자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계)

  • Kim, Jong-Beom;Jeong, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

Development of A Multipurpose Passive Type Radon Monitor (다목적 수동형 라돈농도 측정기 개발)

  • Lee, Bong-Jae;Park, Yeong-Ung
    • Radioisotope journal
    • /
    • v.21 no.4
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF

The Study of the Photo Diode Output Signal for Pusle Radiation Detection (펄스방사선 탐지를 위한 Photo Diode 출력특성 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.869-871
    • /
    • 2012
  • In this paper, we make silicon photodiodes for the detection of pulsed radiation that affects electronics devices and study the output characteristics of photodiodes using circuit design. We conducted the simulation for pulse sensing circuit and experimented the photodiode output characteristics using a high luminance light emitting diode. The results can be used for the design of the input sensor that is trigger of additional module for protecting a electoronics circuit from high energy pulse radiation.

  • PDF

Development of Prototype Electronic Dosimeter using the Silicon PIN Diode Detector (실리콘 PIN 다이오드 검출기를 이용한 전자선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.197-205
    • /
    • 2000
  • A prototype electronic dosimeter(PED) adopting a silicon PIN diode detector as a radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this PED has been performance-tested by using a reference photon radiation field. As a result in a electronic performance test, radiation signals from a detector were well observed in the signal processing circuit. The radiation detection sensitivity of this PED after several test-irradiations to $^{137}Cs$ gamma radiation source appeared to be 1.85 cps/$Gy{\cdot}h^{-1}$ with 19.3% of the coefficient of variation, which satisfied the performance criteria for the active personnel radiation monitor. Further improvement of the electronic circuit and operating program will enable the PED to be used in personal monitoring purpose.

  • PDF

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.

A Study on Fault Detection Scheme on TMRed Circuits (삼중화된 회로에서의 결함 감지를 위한 방법에 관한 연구)

  • Kang, Dong-Soo;Lee, Jong-Kil;Jhang, Kyoung-Son
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06b
    • /
    • pp.313-316
    • /
    • 2011
  • SRAM-based FPGAs are very sensitive to single event upset(SEU) induced by space irradiation. To mitigate SEU effects, space applications employ some mitigation schemes. The triple modular redundancy(TMR) is a well-known mitigation scheme. It uses one or three voters as well as three identical blocks performing the same work. The voters can mask out one error in the outputs from the three replicated blocks. One SEU error in TMRed circuits can be masked but it needs to be detected for some reasons such as to analyze the SEU effects in the satellite or to recover the circuits from the error before additional error occur. In this paper, we developed a fault detection circuit and reporting system to detect a fault on the TMRed circuits. To verify our error detection circuit and reporting circuit, we performed an irradiation test at MC-50 Cyclotron. Experimental results showed that error detection circuit can detect a fault on the TMRed test circuit in radiation environment.

Coordinate Measurement in Wired Tablet Using a Electromagnetic Induction System (전자기유도기술을 이용한 유선 태블릿 좌표 측정)

  • Hong, Dong-Goo;Ryu, Young-Kee
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1100
    • /
    • 2008
  • In this paper, we would like to introduce a simple and low cost wired pointing device by using a electromagnetic induction. A number of patents of Wacom describe electronic drawing devices or styluses. The movement of the stylus over a tablet is traced electronically and used applied to a resonant circuit in the stylus. Electromagnetic radiation emitted by the resonant circuit is detected by a sensing mechanism and location processing is used to locate the stylus. In this research, difference coil principle is used to detect the emitted radiation of the resonant circuit in the pen. This detection device shows good performance to detect the location of the pen on the tablet.

  • PDF

A Recording System For Nuclear Radation Detection by Means Of Circular Radial Deflection (원형방사상편향에 의한 방사능계측용 기록장치)

  • 이희용
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 1966
  • In this article, a recording system for nuclear radiation detection by means of circular radial deflection as an instrument and its applications are described. In the electronic circuit of the instrument, the linearity of a deflected pulse on a circular sweep is especially contribed by employing a multiplying circuit, not to mention the one of a circular time base itself. A sequence of random pulses was recorded on a circular sweep of the CRT screen by means of one cycle unblanking due to a logic circuit. It seems that the intrument is suitable for measuring a decay curve of a short-lived nuclide and its pulse spectrum

  • PDF

Compact Microwave Heartbeat Proximity Sensor Under Human Body Movement (인체 움직임을 고려한 소형 근접 마이크로파 심박 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.63-69
    • /
    • 2020
  • In this paper, a small microwave sensor that can be applied to a wearable device is proposed because it can detect the heartbeat signal of a human body moving irregularly at low speed. It consist of balanced microstrip radiation patches in the 2.4 GHz ISM band, self-oscillation detection circuit, and feedback circuit. Based on the theoretical development and simulation, the validity of the proposed structure was confirmed and the manufactured prototype was tested. The board size of the circuit is as small as 65mm × 85㎟, and has a low power consumption of 60mW thanks to the simple RF circuit structure. Finally heartbeat signal has been obtained from a human body moving at low speed (0.5Hz) within a linear distance of 2 to 30mm close to the sensor and a lateral distance of ±20mm.

Long term activity measurement of the primary circuit water on the LVR-15 research reactor

  • Ladislav Viererbl;Vit Klupak;Hana Assmann Vratislavska
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1250-1253
    • /
    • 2024
  • Activity measurement of the primary circuit water of fission reactors is one method that can provide early detection of a damaged fuel assembly in the reactor core. This is an important aspect in the safe operation of the reactor and for radiation protection of staff. Radionuclides in the primary circuit water are produced by the activation of stable nuclides and the fission of fissile nuclides, mainly the isotope 235U. In the LVR-15 research reactor, measurement of the activity of the primary circuit water has been regularly undertaken since 1996. A water sample is taken from the primary circuit every week and the activities are measured four days later using gamma spectrometry. The results of these long-term measurements from 1996 to 2022 are presented. The activity time dependences of the individual radionuclides are discussed in relation to fuel assembly damage and for events connected to contamination of the water by objects inserted into the primary circuit during experiments carried out near the reactor core.